Search NASA⌕ Search

SEARCH · Search NASA

Results for “Variational”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Climate variables explain neutral and adaptive variation within salmonid metapopulations: the importance of replication in landscape genetics

Abstract Understanding how environmental variation influences population genetic structure is important for conservation management because it can reveal how human stressors influence population connectivity, genetic diversity and persistence. We used riverscape genetics modelling to assess whether climatic and habitat variables were related to neutral and adaptive patterns of genetic differentiation (population‐specific and pairwise F ST ) within five metapopulations (79 populations, 4583 individuals) of steelhead trout ( Oncorhynchus mykiss ) in the Columbia River Basin, USA . Using 151 putatively neutral and 29 candidate adaptive SNP loci, we found that climate‐related variables (winter precipitation, summer maximum temperature, winter highest 5% flow events and summer mean flow) best explained neutral and adaptive patterns of genetic differentiation within metapopulations, suggesting that climatic variation likely influences both demography (neutral variation) and local adaptation (adaptive variation). However, we did not observe consistent relationships between climate variables and F ST across all metapopulations, underscoring the need for replication when extrapolating results from one scale to another (e.g. basin‐wide to the metapopulation scale). Sensitivity analysis (leave‐one‐population‐out) revealed consistent relationships between climate variables and F ST within three metapopulations; however, these patterns were not consistent in two metapopulations likely due to small sample sizes ( N = 10). These results provide correlative evidence that climatic variation has shaped the genetic structure of steelhead populations and highlight the need for replication and sensitivity analyses in land and riverscape genetics.

Hand, Brian K.↗

Adaptive variation and plasticity in non‐structural carbohydrate storage in a temperate tree species

Abstract Trees' total amount of non‐structural carbohydrate (NSC) stores and the proportion of these stores residing as insoluble starch are vital traits for individuals living in variable environments. However, our understanding of how stores vary in response to environmental stress is poorly understood as the genetic component of storage is rarely accounted for in studies. Here, we quantified variation in NSC traits in branch samples taken from over 600 clonally transplanted black cottonwood ( Populus trichocarpa) trees grown in two common gardens. We found heritable variation in both total NSC stores and the proportion of stores in starch (H 2 TNC = 0.19, H 2 PropStarch = 0.31), indicating a substantial genetic component of variation. In addition, we found high amounts of plasticity in both traits in response to cold temperatures and significant genotype‐by‐environment (GxE) interactions in the total amount of NSC stored (54% of P is GxE). This finding of high GxE indicates extensive variation across trees in their response to environment, which may explain why previous studies of carbohydrate stores' responses to stress have failed to converge on a consistent pattern. Overall, we found high amounts of environmental and genetic variation in NSC storage concentrations, which may bolster species against future climate change.

Blumstein, Meghan↗

Effects of Part-to-Part Flow Variations on Overall Effectiveness and Life of Rotating Turbine Blades

Abstract As firing temperatures in gas turbine engines continue to increase to achieve high efficiencies, components in the main gas path must be protected with cooling flows to ensure lifing targets are met. Manufacturing variations, however, influence the performance and life characteristics of components with the same nominal design. This study presents blade flow and overall cooling effectiveness measurements for nine true-scale, aero engine turbine blades with realistic manufacturing variations. Flow measurements were made through each blade at a fixed pressure ratio to determine flow variability between holes and between blades. Infrared thermography was used to capture spatially-resolved temperature measurements reported as overall effectiveness on the same nine blades under high-speed rotating conditions at the Steady Thermal Aero Research Turbine Laboratory. Thermal performance was correlated with blade flow performance indicating substantial blade-to-blade variations resulting from manufacturing differences. Measurements also indicated wide variations in cooling jet trajectories as well as overall cooling effectiveness. Finally, the observed blade-to-blade variations in effectiveness were scaled to engine conditions with lifing estimates showing some blades would be expected to last only half as long as others due to manufacturing variability.

Engineering↗

A novel method to evaluate gamma camera rotational uniformity and sensitivity variation

An alternative to the conventional method of performing the AAPM Report 52 rotational uniformity and sensitivity test has been developed. In contrast to the conventional method in which a Co-57 sheet source is fastened to the collimator, this new point-source method acquires the images intrinsically using a Tc-99m point source placed near the isocenter of gantry rotation. As with the conventional method, the point-source method acquires 5x10{sup 6} count flood images at four distinct gantry positions to calculate the maximum sensitivity variation (MSV)--a quantitative metric of rotational uniformity and sensitivity variation. The point-source method incorporates corrections for the decay of Tc-99m between acquisitions, the curvature in the image intensity due to variation in photon flux across the detector from a near-field source, and the source-to-detector distance variations between views. The raw point-source images were fitted with an analytic function in order to compute curvature- and distance-corrected images prior to analysis. Five independent MSV measurements were performed using both conventional and point-source methods on a single detector of a dual-headed SPECT system to estimate the precision of each method. The precision of the point-source method was further investigated by performing ten independent measurements of MSV on six different detectors. Correlation between the MSV calculated by the two methods was investigated by performing the test on nine different detectors using both methods. Different levels of sensitivity variations were also simulated on four detectors to generate 40 additional paired points for correlation analysis. The effect of the total image counts on the MSV estimated with the new method was evaluated by acquiring image sequences with 5x10{sup 6}, 10x10{sup 6}, and 20x10{sup 6} count images. The MSV calculated using the conventional and point-source methods exhibited a high degree of correlation and consistency with equivalence. The precision of the point-source method (0.145%) is lower than the conventional method (0.04%) but sufficient to test MSV. No statistically significant dependence of MSV with the point-source method on the total image counts over a range of (5-20)x10{sup 6} counts was observed. Curvature correction of the images prior to the generation of difference images renders images more conducive to qualitative inspection for structured, nonrandom patterns. The advantages of the new methodology are that multiple detectors of a gamma camera can be evaluated simultaneously which substantially reduces the time required for MSV testing and the reduced risk of accidental damage to the collimators and patient proximity detection system from having to mount a sheet source on each of the detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon beam quality variations of a flattening filter free linear accelerator

Purpose: Recently, there has been an increasing interest in operating conventional linear accelerators without a flattening filter. The aim of this study was to determine beam quality variations as a function of off-axis ray angle for unflattened beams. In addition, a comparison was made with the off-axis energy variation in flattened beams. Methods: Two Elekta Precise linear accelerators were modified in order to enable radiation delivery with and without the flattening filter in the beam line. At the Medical University Vienna (Vienna, Austria), half value layer (HVL) measurements were performed for 6 and 10 MV with an in-house developed device that can be easily mounted on the gantry. At St. Luke's Hospital (Dublin, Ireland), measurements were performed at 6 MV in narrow beam geometry with the gantry tilted around 270 deg. with pinhole collimators, an attenuator, and the chamber positioned on the table. All attenuation measurements were performed with ionization chambers and a buildup cap (2 mm brass) or a PMMA mini phantom (diameter 3 cm, measurement depth 2.5 cm). Results: For flattened 6 and 10 MV photon beams from the Elekta linac the relative HVL({theta}) varies by about 11% for an off-axis ray angle {theta}=10 deg. These results agree within {+-}2% with a previously proposed generic off-axis energy correction. For unflattened beams, the variation was less than 5% in the whole range of off-axis ray angles up to 10 deg. The difference in relative HVL data was less than 1% for unflattened beams at 6 and 10 MV. Conclusions: Off-axis energy variation is rather small in unflattened beams and less than half the one for flattened beams. Thus, ignoring the effect of off-axis energy variation for dose calculations in unflattened beams can be clinically justified.

43 PARTICLE ACCELERATORS↗

SU-D-18A-06: Variation of Controlled Breath Hold From CT Simulation to Treatment and Its Dosimetric Impact for Left-Sided Breast Radiotherapy with a Real-Time Optical Tracking System

Purpose: Different breath-hold (BH) maneuvers (abdominal breathing vs. chest breathing) during CT simulation and treatment can lead to chest wall positional variation. The purpose of this study is to quantify the variation of active breathing control (ABC)-assisted BH and estimate its dosimetric impact for left-sided whole-breast radiotherapy with a real-time optical tracking system (OTS). Methods: Seven breast cancer patients were included. An in-house OTS tracked an infrared (IR) marker affixed over the xiphoid process of the patient at CT simulation and throughout the treatment course to measure BH variations. Correlation between the IR marker and the breast was studied for dosimetric purposes. The positional variations of 860 BHs were retrospectively incorporated into treatment plans to assess their dosimetric impact on breast and cardiac organs (heart and left anterior descending artery [LAD]). Results: The mean intrafraction variations were 2.8 mm, 2.7 mm, and 1.6 mm in the anteroposterior (AP), craniocaudal (CC), and mediolateral (ML) directions, respectively. Mean stability in any direction was within 1.5 mm. A general trend of BH undershoot at treatment relative to CT simulation was observed with an average of 4.4 mm, 3.6 mm, and 0.1 mm in the AP, CC, and ML directions, respectively. Undershoot up to 12.6 mm was observed for individual patients. The difference between the planned and delivered dose to breast targets was negligible. The average planned/delivered mean heart doses, mean LAD doses, and max LAD doses were 1.4/2.1, 7.4/15.7, and 18.6/31.0 Gy, respectively. Conclusion: Systematic undershoot was observed in ABC-assisted BHs from CT simulation to treatment. Its dosimetric impact on breast coverage was minimized with image guidance, but the benefits of cardiac organ sparing were degraded. A real-time tracking system can be used in junction with the ABC device to improve BH reproducibility.

60 APPLIED LIFE SCIENCES↗

SU-E-T-326: The Oxygen Saturation (SO2) and Breath-Holding Time Variation Applied Active Breathing Control (ABC)

Purpose: To study the oxygen saturation (SO2) and breath-holding time variation applied active breathing control (ABC) in radiotherapy of tumor. Methods: 24 volunteers were involved in our trials, and they all did breath-holding motion assisted by ELEKTA Active Breathing Coordinator 2.0 for 10 times respectively. And the patient monitor was used to observe the oxygen saturation (SO2) variation. The variation of SO2, and length of breath-holding time and the time for recovering to the initial value of SO2 were recorded and analyzed. Results: (1) The volunteers were divided into two groups according to the SO2 variation in breath-holding: A group, 14 cases whose SO2 reduction were more than 2% (initial value was 97% to 99%, while termination value was 91% to 96%); B group, 10 cases were less than 2% in breath-holding without inhaling oxygen. (2) The interfraction breath holding time varied from 8 to 20s for A group compared to the first breath-holding time, and for B group varied from 4 to 14s. (3) The breathing holding time of B group prolonged mean 8s, compared to A group. (4) The time for restoring to the initial value of SO2 was from 10s to 30s. And the breath-holding time shortened obviously for patients whose SO2 did not recover to normal. Conclusion: It is very obvious that the SO2 reduction in breath-holding associated with ABC for partial people. It is necessary to check the SO2 variation in breath training, and enough time should be given to recover SO2.

60 APPLIED LIFE SCIENCES↗

SU-E-T-429: Uncertainties of Cell Surviving Fractions Derived From Tumor-Volume Variation Curves

Purpose: To evaluate uncertainties of cell surviving fraction reconstructed from tumor-volume variation curves during radiation therapy using sensitivity analysis based on linear perturbation theory. Methods: The time dependent tumor-volume functions V(t) have been calculated using a twolevel cell population model which is based on the separation of entire tumor cell population in two subpopulations: oxygenated viable and lethally damaged cells. The sensitivity function is defined as S(t)=[δV(t)/V(t)]/[δx/x] where δV(t)/V(t) is the time dependent relative variation of the volume V(t) and δx/x is the relative variation of the radiobiological parameter x. The sensitivity analysis was performed using direct perturbation method where the radiobiological parameter x was changed by a certain error and the tumor-volume was recalculated to evaluate the corresponding tumor-volume variation. Tumor volume variation curves and sensitivity functions have been computed for different values of cell surviving fractions from the practically important interval S{sub 2}=0.1-0.7 using the two-level cell population model. Results: The sensitivity functions of tumor-volume to cell surviving fractions achieved a relatively large value of 2.7 for S{sub 2}=0.7 and then approached zero as S{sub 2} is approaching zero Assuming a systematic error of 3-4% we obtain that the relative error in S{sub 2} is less that 20% in the range S2=0.4-0.7. This Resultis important because the large values of S{sub 2} are associated with poor treatment outcome should be measured with relatively small uncertainties. For the very small values of S2<0.3, the relative error can be larger than 20%; however, the absolute error does not increase significantly. Conclusion: Tumor-volume curves measured during radiotherapy can be used for evaluation of cell surviving fractions usually observed in radiation therapy with conventional fractionation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-520: Four-Dimensional Dose Calculation Algorithm Considering Variations in Dose Distribution Induced by Sinusoidal One-Dimensional Motion Patterns

Purpose: To investigate quantitatively the variations in dose-distributions induced by motion by measurements and modeling. A four-dimensional (4D) motion model of dose distributions that accounts for different motion parameters was developed. Methods: Variations in dose distributions induced by sinusoidal phantom motion were measured using a multiple-diode-array-detector (MapCheck2). MapCheck2 was mounted on a mobile platform that moves with adjustable calibrated motion patterns in the superior-inferior direction. Various plans including open and intensity-modulated fields were used to irradiate MapCheck2. A motion model was developed to predict spatial and temporal variations in the dose-distributions and dependence on the motion parameters using pencil-beam spread-out superposition function. This model used the superposition of pencil-beams weighted with a probability function extracted from the motion trajectory. The model was verified with measured dose-distributions obtained from MapCheck2. Results: Dose-distribution varied considerably with motion where in the regions between isocenter and 50% isodose-line, dose decreased with increase of the motion amplitude. Dose levels increased with increase in the motion amplitude in the region beyond 50% isodose-line. When the range of motion (ROM=twice amplitude) was smaller than the field length both central axis dose and the 50% isodose-line did not change with variation of motion amplitude and remained equal to the dose of stationary phantom. As ROM became larger than the field length, the dose level decreased at central axis dose and 50% isodose-line. Motion frequency and phase did not affect the dose distributions which were delivered over an extended time longer than few motion cycles, however, they played an important role for doses delivered with high-dose-rates within one motion cycle . Conclusion: A 4D-dose motion model was developed to predict and correct variations in dose distributions induced by one-dimensional sinusoidal motion. This model was verified with measured dose-distributions and can be expanded to consider complicated patient motion patterns.

07 ISOTOPE AND RADIATION SOURCES↗

TU-F-17A-09: Four-Dimensional Cone Beam CT Ventilation Imaging Can Detect Interfraction Lung Function Variations for Locally Advanced Lung Cancer Patients

Purpose: Four-dimensional cone beam CT ventilation imaging (4D-CBCT VI) is a novel functional lung imaging modality requiring validation. We hypothesize that 4D-CBCT VI satisfies a necessary condition for validity: that intrafraction variations (e.g. due to poor 4D-CBCT image quality) are substantially different to interfraction variations (e.g. due to changes in underlying function). We perform the first comparison of intrafraction (pre/post fraction) and interfraction (week-to-week) 4D-CBCT VIs for locally advanced non small cell lung cancer (LA NSCLC) patients undergoing radiation therapy. Methods: A total of 215 4D-CBCT scans were acquired for 19 LA NSCLC patients over 4-6 weeks of radiation therapy, including 75 pairs of pre-/post-fraction scans on the same day. 4D-CBCT VIs were obtained by applying state-of-the-art, B-spline deformable image registration to obtain the Jacobian determinant of deformation between the end-exhale and end-inhale phases. All VIs were deformably registered to the corresponding first day scan, normalized between the 10th and 90th percentile values and cropped to the ipsilateral lung only. Intrafraction variations were assessed by computing the mean and standard deviation of voxel-wise differences between all same-day pairs of pre-/post-fraction VIs. Interfraction differences were computed between first-day VIs and treatment weeks 2, 4 and 6 for all 19 patients. We tested the hypothesis by comparing cumulative distribution functions (CDFs) of intrafraction and interfraction ventilation differences using two-sided Kolmogorov-Smirnov goodness-of-fit tests. Results: The (mean ± std. dev.) of intrafraction differences was (−0.007 ± 0.079). Interfraction differences for weeks 2, 4 and 6 were (−0.035 ± 0.103), (−0.006 ± 0.094) and (−0.019 ± 0.127) respectively. For week 2, the changes in CDFs for intrafraction and interfraction differences approached statistical significance (p=0.099). Conclusion: We have shown that 4D-CBCT VI can satisfy a necessary condition for validity; intrafraction variations do not limit the ability to measure interfraction variations in LA NSCLC patients. This work is supported by a Cancer Institute NSW Early Career Fellowship, an NHMRC Australia Fellowship and NIH P01CA116602.

60 APPLIED LIFE SCIENCES↗

WE-G-18C-05: Characterization of Cross-Vendor, Cross-Field Strength MR Image Intensity Variations

Purpose: Variations in MR image intensity and image intensity nonuniformity (IINU) can challenge the accuracy of intensity-based image segmentation and registration algorithms commonly applied in radiotherapy. The goal of this work was to characterize MR image intensity variations across scanner vendors and field strengths commonly used in radiotherapy. Methods: ACR-MRI phantom images were acquired at 1.5T and 3.0T on GE (450w and 750, 23.1), Siemens (Espree and Verio, VB17B), and Philips (Ingenia, 4.1.3) scanners using commercial spin-echo sequences with matched parameters (TE/TR: 20/500 ms, rBW: 62.5 kHz, TH/skip: 5/5mm). Two radiofrequency (RF) coil combinations were used for each scanner: body coil alone, and combined body and phased-array head coils. Vendorspecific B1- corrections (PURE/Pre-Scan Normalize/CLEAR) were applied in all head coil cases. Images were transferred offline, corrected for IINU using the MNI N3 algorithm, and normalized. Coefficients of variation (CV=σ/μ) and peak image uniformity (PIU = 1−(Smax−Smin)/(Smax+Smin)) estimates were calculated for one homogeneous phantom slice. Kruskal-Wallis and Wilcoxon matched-pairs tests compared mean MR signal intensities and differences between original and N3 image CV and PIU. Results: Wide variations in both MR image intensity and IINU were observed across scanner vendors, field strengths, and RF coil configurations. Applying the MNI N3 correction for IINU resulted in significant improvements in both CV and PIU (p=0.0115, p=0.0235). However, wide variations in overall image intensity persisted, requiring image normalization to improve consistency across vendors, field strengths, and RF coils. These results indicate that B1- correction routines alone may be insufficient in compensating for IINU and image scaling, warranting additional corrections prior to use of MR images in radiotherapy. Conclusions: MR image intensities and IINU vary as a function of scanner vendor, field strength, and RF coil configuration. A two-step strategy consisting of MNI N3 correction followed by normalization was required to improve MR image consistency. Funding provided by Advancing a Healthier Wisconsin.

60 APPLIED LIFE SCIENCES↗

SU-F-T-284: The Effect of Linear Accelerator Output Variation On the Quality of Patient Specific Rapid Arc Verification Plans

Purpose: The aim of the current study is to investigate the effect of machine output variation on the delivery of the RapidArc verification plans. Methods: Three verification plans were generated using Eclipse™ treatment planning system (V11.031) with plan normalization value 100.0%. These plans were delivered on the linear accelerators using ArcCHECK− device, with machine output 1.000 cGy/MU at calibration point. These planned and delivered dose distributions were used as reference plans. Additional plans were created in Eclipse− with normalization values ranging 92.80%–102% to mimic the machine output ranging 1.072cGy/MU-0.980cGy/MU, at the calibration point. These plans were compared against the reference plans using gamma indices (3%, 3mm) and (2%, 2mm). Calculated gammas were studied for its dependence on machine output. Plans were considered passed if 90% of the points satisfy the defined gamma criteria. Results: The gamma index (3%, 3mm) was insensitive to output fluctuation within the output tolerance level (2% of calibration), and showed failures, when the machine output exceeds ≥3%. Gamma (2%, 2mm) was found to be more sensitive to the output variation compared to the gamma (3%, 3mm), and showed failures, when output exceeds ≥1.7%. The variation of the gamma indices with output variability also showed dependence upon the plan parameters (e.g. MLC movement and gantry rotation). The variation of the percentage points passing gamma criteria with output variation followed a non-linear decrease beyond the output tolerance level. Conclusion: Data from the limited plans and output conditions showed that gamma (2%, 2mm) is more sensitive to the output fluctuations compared to Gamma (3%,3mm). Work under progress, including detail data from a large number of plans and a wide range of output conditions, may be able to conclude the quantitative dependence of gammas on machine output, and hence the effect on the quality of delivered rapid arc plans.

60 APPLIED LIFE SCIENCES↗

Shewanella baltica Ecotypes Have Wide Transcriptional Variation under the Same Growth Conditions

In bacterial populations, subtle expressional differences may promote ecological specialization through the formation of distinct ecotypes. In a barrier-free habitat, this process most likely precedes population divergence and may predict speciation events. To examine this, we used four sequenced strains of the bacterium Shewanella baltica, OS155, OS185, OS195, and OS223, as models to assess transcriptional variation and ecotype formation within a prokaryotic population. All strains were isolated from different depths throughout a water column of the Baltic Sea, occupying different ecological niches characterized by various abiotic parameters. Although the genome sequences are nearly 100% conserved, when grown in the laboratory under standardized conditions, all strains exhibited different growth rates, suggesting significant expressional variation. Using the Ecotype Simulation algorithm, all strains were considered to be discrete ecotypes when compared to 32 other S. baltica strains isolated from the same water column, suggesting ecological divergence. Next, we employed custom microarray slides containing oligonucleotide probes representing the core genome of OS155, OS185, OS195, and OS223 to detect natural transcriptional variation among strains grown under identical conditions. Significant transcriptional variation was noticed among all four strains. Differentially expressed gene profiles seemed to coincide with the metabolic signatures of the environment at the original isolation depth. Transcriptional pattern variations such as the ones highlighted here may be used as indicators of short-term evolution emerging from the formation of bacterial ecotypes.

59 BASIC BIOLOGICAL SCIENCES↗

Acute stress reduces population-level metabolic and proteomic variation

Abstract Background Variation in omics data due to intrinsic biological stochasticity is often viewed as a challenging and undesirable feature of complex systems analyses. In fact, numerous statistical methods are utilized to minimize the variation among biological replicates. Results We demonstrate that the common statistics relative standard deviation (RSD) and coefficient of variation (CV), which are often used for quality control or part of a larger pipeline in omics analyses, can also be used as a metric of a physiological stress response. Using an approach we term Replicate Variation Analysis (RVA), we demonstrate that acute physiological stress leads to feature-wide canalization of CV profiles of metabolomes and proteomes across biological replicates. Canalization is the repression of variation between replicates, which increases phenotypic similarity. Multiple in-house mass spectrometry omics datasets in addition to publicly available data were analyzed to assess changes in CV profiles in plants, animals, and microorganisms. In addition, proteomics data sets were evaluated utilizing RVA to identify functionality of reduced CV proteins. Conclusions RVA provides a foundation for understanding omics level shifts that occur in response to cellular stress. This approach to data analysis helps characterize stress response and recovery, and could be deployed to detect populations under stress, monitor health status, and conduct environmental monitoring.

59 BASIC BIOLOGICAL SCIENCES↗

Gauge properties of the guiding center variational symplectic integrator

Recently, variational symplectic algorithms have been developed for the long-time simulation of charged particles in magnetic fields. As a direct consequence of their derivation from a discrete variational principle, these algorithms have very good long-time energy conservation, as well as exactly preserving discrete momenta. We present stability results for these algorithms, focusing on understanding how explicit variational integrators can be designed for this type of system. It is found that for explicit algorithms an instability arises because the discrete symplectic structure does not become the continuous structure in the t → 0 limit. We examine how a generalized gauge transformation can be used to put the Lagrangian in the "antisymmetric discretization gauge," in which the discrete symplectic structure has the correct form, thus eliminating the numerical instability. Finally, it is noted that the variational guiding center algorithms are not electromagnetically gauge invariant. By designing a model discrete Lagrangian, we show that the algorithms are approximately gauge invariant as long as A and Φ are relatively smooth. A gauge invariant discrete Lagrangian is very important in a variational particle-in-cell algorithm where it ensures current continuity and preservation of Gauss's law.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Long-period variations in the radial velocity of spectroscopic binary M giant μ Ursae Majoris

We report that the spectroscopic binary μ Ursae Majoris (μ UMa) has secondary RV variations of 471.2 days in addition to those of 230.0 days already known. Keplerian orbit analysis yields stellar mass companions of 1.6 M{sub ⊙} for the 230 day period and 0.14 M{sub ⊙} for the 471 day period. However, the HIPPARCOS photometries show a period similar to the stellar rotational period, which is one-quarter of the RV period. Variations in the bisector velocity curvature show a period of 463.6 days. We also find ∼473 day variations in the equivalent width (EW) measurements of the H{sub α} and H{sub β} lines, whose origin is probably stellar activity. We note that the nature of 471 day variations is similar to one observed in “Sequence D” of Asymptotic Giant Branch pulsating stars. We therefore conclude that the RV and the EW variations in the spectroscopic binary M giant μ UMa A originate from the complex pulsations and the chromospheric activity.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraint on a cosmological variation in the proton-to-electron mass ratio from electronic co absorption

Carbon monoxide (CO) absorption in the sub-damped Lyα absorber at redshift z{sub abs}≃2.69 toward the background quasar SDSS J123714.60+064759.5 (J1237+0647) was investigated for the first time in order to search for a possible variation of the proton-to-electron mass ratio, μ, over a cosmological timescale. The observations were performed with the Very Large Telescope/Ultraviolet and Visual Echelle Spectrograph with a signal-to-noise ratio of 40 per 2.5 km s{sup −1} per pixel at ∼5000 Å. Thirteen CO vibrational bands in this absorber are detected: the A{sup 1}Π − X{sup 1}Σ{sup +} (ν{sup ′}, 0) for ν{sup ′}=0--8, B{sup 1}Σ{sup +} − X{sup 1}Σ{sup +} (0, 0), C{sup 1}Σ{sup +} − X{sup 1}Σ{sup +} (0, 0), and E{sup 1}Π − X{sup 1}Σ{sup +} (0, 0) singlet–singlet bands and the d{sup 3}Δ − X{sup 1}Σ{sup +} (5, 0) singlet–triplet band. An updated database including the most precise molecular inputs needed for a μ-variation analysis is presented for rotational levels J = 0–5, consisting of transition wavelengths, oscillator strengths, natural lifetime damping parameters, and sensitivity coefficients to a variation of the proton-to-electron mass ratio. A comprehensive fitting method was used to fit all the CO bands at once and an independent constraint of Δμ/μ=(0.7±1.6{sub stat}±0.5{sub syst})×10{sup −5} was derived from CO only. A combined analysis using both molecular hydrogen and CO in the same J1237+0647 absorber returned a final constraint on the relative variation of Δμ/μ=(−5.6±5.6{sub stat}±3.1{sub syst})×10{sup −6}, which is consistent with no variation over a look-back time of ∼11.4 Gyr.

79 ASTRONOMY AND ASTROPHYSICS↗

Neptune's Latitudinal Variations as Viewed with ALMA

We present spatially resolved millimeter maps of Neptune between 95 and 242 GHz taken with the Atacama Large Millimeter/submillimeter Array (ALMA) in 2016–2017. The millimeter weighting functions peak between 1 and 10 bar on Neptune, lying in between the altitudes probed at visible/infrared and centimeter wavelengths. Thus, these observations provide important constraints on the atmospheric structure and dynamics of Neptune. We identify seven well-resolved latitudinal bands of discrete brightness temperature variations, on the order of 0.5–3 K in all three observed ALMA spectral bands. We model Neptune’s brightness temperature using the radiative-transfer code Radio-BEAR and compare how various H{sub 2}S, CH{sub 4}, and ortho-/para-H{sub 2} abundance profiles can fit the observed temperature variations across the disk. We find that observed variations in brightness temperature with latitude can be explained by variations in the H{sub 2}S profile that range from sub- to supersaturations at altitudes above the 10 bar pressure level, while variations in CH{sub 4} improve the quality of fit near the equator. At the south polar cap, our best-fit model has a depleted deep atmospheric abundance of H{sub 2}S from 30 to only 1.5 times the protosolar value, while simultaneously depleting the CH{sub 4} abundance. This pattern of enhancement and depletion of condensible species is consistent with a global circulation structure where enriched air rises at the midlatitudes (32°–12°S) and north of the equator (2°–20°N), and dry air descends at the poles (90°–66°S) and just south of the equator (12°S–2°N). Our analysis finds more complex structure near the equator than accounted for in previous circulation models.

79 ASTRONOMY AND ASTROPHYSICS↗