Search NASA⌕ Search

SEARCH · Search NASA

Results for “Waste Heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The Tiny Heater: Creating Heat with Hybrid Nano-Antennas [LDRD HQ Highlights Article]

SRNL scientists demonstrate that an electromagnetic field, either as a light or magnetic field, is selectively coupled to shape-selective hybrid nano-antennas for efficient thermal processes. Localized heating occurs extremely fast, reducing the ‘wasted' thermal load on the environment. Being non-contact, efficient, and highly selective, the required input energy is greatly diminished. By strategically placing nano-antennas at desired locations, heat can be controlled at the nano-level. The location for nano-antennas, and the subsequent energy deposition, may be fine-tuned through specific chemical, steric, or magnetic interactions. The nano-antennas, composed of combinations of plasmonic, magnetic, and hydride components, are used for controlled release of hydrogen isotopes, chemotherapy drugs, environmental contaminants, enhanced catalytic processes, (bio)imaging and therapeutics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Investigation of Thermolytic Hydrogen Generation Rate in Tank 44 Dissolved Saltcake Samples

Saltcake core samples collected from Tank 44 in 2006 were dissolved to provide material for HGR measurements applicable to F-Area dissolved saltcake material. Additionally, characterization was performed on the Tank 44 saltcake material. The following are key results from the Tank 44 saltcake characterization. The Tank 44 Upper Saltcake Composite, corresponding to the 171 to 285 inch tank level, contained by mass approximately 69% sodium nitrate, 11% sodium carbonate, 8% sodium nitrite, smaller amounts of other salts and components, and 9% unquantified (which includes water, water of hydration, oxygen/hydrogen content of oxides and hydroxides, and uncertainty). The Tank 44 Lower Saltcake Composite, corresponding to the 76 to 114 inch tank level, contained by mass approximately 49% sodium carbonate, 18% sodium nitrate, smaller amounts of other salts, at least 8% sludge, and 9% unquantified (see above). The dissolved saltcake contained free hydroxide less than quantifiable (<0.01 M) due to the limited quantity of material that could be removed from the Shielded Cells based on the sample radioactivity. Measurement by pH paper provided an approximate pH of 12. The following are key results from the Tank 44 HGR testing. During boiling at 106.7 °C, HGR for Tank 44 dissolved saltcake without added glycolate was 7.2×10 -8 ft 3 h -1 gal -1 . During boiling at 106.9 °C, HGR for Tank 44 dissolved saltcake with 1000 mg/L of added glycolate was 8.2×10 -8 ft 3 h -1 gal -1 . For the test without added glycolate, the first several HGR measurements at 70, 85, and 100 °C gave indication of the release of dissolved hydrogen and should not be used to represent the sustained thermolytic HGR for those temperatures. The measurements at boiling are the best representation of thermolysis in this testing. Carbon dioxide was observed at concentrations up to 6 vol% in the flow-system offgas for the test at boiling. Methane generation was observed at 100 °C and boiling. Methane concentration in the total gas generated during testing remained well below the lower flammability limit for methane in air. The addition of 1000 mg/L of glycolate did not have a significant impact on the hydrogen generation rates measured during this testing. The low hydroxide concentration in the Tank 44 dissolved saltcake likely influenced the relatively low thermolytic HGR and high carbon dioxide release observations in this testing. Based on the observation that methane was generated or released upon heating SRS radioactive Tank 44 waste samples to 100 °C and above, we recommend gaining a greater understanding of the cause and mechanism of its generation. First, the applicable literature should be reviewed to reveal the thermolytic methane generation mechanisms of possible methane generating species in the SRS CSTF. If warranted, a plan should be developed for simulant tests with methylated siloxanes and other applicable compounds in order to gain a better mechanistic understanding of methane generation in the SRS CSTF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spent Nuclear Fuel and Reprocessing Waste Inventory: Spent Fuel and Waste Disposition

This report provides information on the inventory of spent nuclear fuel (SNF) in the United States located at Nuclear Power Reactor (NPR) and Independent Spent Fuel Storage Installation (ISFSI) sites, as well as SNF and reprocessing waste located at U.S. Department of Energy (DOE) sites and other research and development (R&D) centers as of the end of calendar year 2021. Actual or estimated quantitative values for current inventories are provided along with inventory forecasts derived from examining different future nuclear power generation scenarios, based on information available and assumptions made at the time the scenarios were developed in the spring of 2022. The report also includes select information on the characteristics associated with the wastes examined (e.g., type, packaging, heat generation rate, decay curves).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Energy and Environmental Analyses of a Solar–Gas Turbine Combined Cycle with Inlet Air Cooling

Sensitivity to ambient air temperatures, consuming a large amount of fuel, and wasting a significant amount of heat dumped into the ambient atmosphere are three major challenges facing gas turbine power plants. This study was conducted to simultaneously solve all three aforementioned GT problems using solar energy and introducing a new configuration that consists of solar preheating and inlet-air-cooling systems. In this study, air was preheated at a combustion chamber inlet using parabolic trough collectors. Then, inlet air to the compressor was cooled by these collectors by operating an absorption cooling cycle. At the design point conditions, this novel proposed integration resulted in a 6.87% relative increase in generated power and a 10.53% relative decrement in fuel consumption, achieving a 19.45% relative increment in the plant’s thermal efficiency. This was accompanied by a reduction of 0.026 kg/s, 4.2 kg/s, and 0.278 kg/s in CO 2 , CO, and NOx emissions, respectively. Finally, spider diagrams were employed to assess the impact of the operating parameters on the overall system’s performance and its associated environmental implications.

14 SOLAR ENERGY↗

MHTLS Cross-flow Heat Exchanger Temperature Performance Data

The presentation and supporting information provide data on the performance of an engineering-scale cross-flow heat exchanger used in hydrothermal liquefaction (HTL). Temperature profiles are provide for the process of waste water treatment sludges and a food waste. The data can be used to model larger-scale heat exchangers used in HTL.

Bioenergy Technologies Tags Heat Exchanger HTL MHT↗

Sequential Ammonia and Carbon Dioxide Adsorption on Pyrolyzed Biomass to Recover Waste Stream Nutrients

Untreated fecal waste in unsewered communities and reactive nitrogen (N) loading from wastewater and urine disposal are important environmental challenges. Through pyrolysis, untreated fecal waste can be converted into amine-rich carbon dioxide (CO 2 ) sorbents, the chemisorption of which tunes the surface chemistry toward ammonia (NH 3 ) uptake. We compared the N-loading potential within amine-rich pyrolyzed human solid waste through exposure to CO 2 followed by NH 3 with the N-loading potential on carboxyl-rich, pyrolyzed oxidized wood using sequential adsorption of isotopically labeled CO 2 and NH 3 . The total N content of pyrolyzed oxidized wood exposed once to NH3 was similar to native, pyrolyzed human solid waste (3.7% compared to 4.6%). However, sorption kinetics and spectroscopic evidence revealed distinct N forms between the two materials affecting subsequent CO 2 and NH 3 uptake. Tertiary amines comprised 70% of N in pyrolyzed waste, compared to only 53% in pyrolyzed oxidized wood. The high heat of adsorption of CO 2 on pyrolyzed human solid waste (50 kJ mol-1) at low concentrations (0.05 mmol CO 2 g -1 ) was indicative of CO 2 reactivity with tertiary amines, consistent with the formation of carbamic acid (Figure S1). Conversely, after exposure to NH 3 , pyrolyzed oxidized wood chemisorbed CO 2 at much higher concentrations (0.7 mmol CO 2 g-1), pointing to primary amines as the active functional moieties. Adsorption kinetics of pyrolyzed oxidized wood revealed continued, albeit diminishing NH 3 uptake with each consecutive CO 2 treatment, averaging 5.9 mmol NH 3 g -1 for the first NH 3 exposure event, and still 3.5 and 2.9 mmol NH 3 g -1 for the second and third. Penetration of 15 NH 3 and 13 CO 2 measured by NanoSIMS reached over 7 µm deep into both materials, explaining the large NH 3 capture. The significantly lower NH 3 adsorption compared to pyrolyzed oxidized wood may be a result of potassium (K) carbonate precipitation precluding a Lewis base interaction between NH 3 and chemisorbed CO 2 , suggested by a 2-fold increase in surface K concentrations after exposure of pyrolyzed human solid waste to CO 2 +NH 3 detected by XPS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of Radiological Contamination at Parks in the Gateway National Recreation Area - 20350

In 2005, the National Park Service was notified that elevated radiation levels were detected at Great Kills Park during a baseline radiological mapping effort conducted by the Counter Terrorism Bureau of the New York City Police Department and the United States Department of Energy. Great Kills Park is in the Staten Island Unit of the Gateway National Recreation Area. A records search determined that approximately 280 acres of the park was established over an area in which the New York City Department of Sanitation placed approximately 15.1 million cubic yards of waste fill from 1944 to 1948. Since 2005, a series of response actions and investigations were conducted on behalf of the National Park Service to mitigate risk to human health and the environment and to determine the nature of radiological contamination at Great Kills Park. The findings support that radiological contamination is related to certain components of waste fill, including incinerator residue from both on and offsite incinerators, coal ash from the historical use of coal-fired boilers for heating, and incidental radiological artifacts in the waste fill due to their historical use and subsequent disposal. A majority of the radiological artifacts were determined to contain radium-226 and included radioluminescent markers, radium impregnated switch board buttons, radium paint containers, and brachytherapy devices. The National Park Service has several other Parks in the Gateway National Recreation Area that were established in areas with a similar history to Great Kills Park, and overlie waste fill historically placed during landfilling operations, including Spring Creek Park and Dead Horse Bay. Over the last year, the National Park Service has performed additional radiological investigations at Great Kills Park as part of the ongoing Remedial Investigation under the Comprehensive Environmental Response, Compensation, and Liability Act. In addition, preliminary radiological investigations were performed at Spring Creek Park and Dead Horse Bay Park in the Jamaica Bay Unit of Gateway National Recreation Area. These investigation activities identified gamma radiation levels above the ambient level, several of which were attributable to radiological artifacts similar in nature to those recovered at Great Kills Park. Ongoing investigations at Parks in the Gateway National Recreation Area support an association between radiological contamination and historical landfilling practices that were common prior to the regulation and control of radioactive materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of non‐framework cation mixing on the structure and crystallization behavior of model high‐level waste glasses

Abstract Spinel crystallization is known to be detrimental to the operation of Joule heated ceramic melters during the vitrification of iron‐rich high‐level nuclear wastes (HLW) into borosilicate glasses. The literature on this subject focuses on tackling the problem by developing empirical constraints to design compositions, which limit the fraction of spinels formed in the melter or by developing empirical models to predict the settling behavior of spinels in the melter as a function of the glass composition. While these empirical models can predict the behavior of most of the compositions, they are not failsafe as there are always some compositions, whose behavior is beyond the predictive ability of these models. This can lead to undesirable situations during the vitrification of the nuclear waste, and therefore an in‐depth investigation of the chemo‐structural descriptors controlling the crystallization behavior in these glasses is warranted. Accordingly, the present study aims to understand the impact of non‐framework cation mixing (i.e., Li + /Na + and Ca 2+ /Na + ) on the structure (through Raman spectroscopy and Mössbauer spectroscopy) and crystallization behavior (through XRD, SEM‐EDS, and vibrating sample magnetometry) of iron‐rich model HLW glasses in the system: (mol.%) x M y O–(25− x ) Na 2 O–9.12 B 2 O 3 –6.4 Al 2 O 3 –51.25 SiO 2 –7.22 Fe 2 O 3 –0.38 MnO–0.08 Cr 2 O 3 –0.55NiO (M y O = Li 2 O or CaO).

Balasubramanya, Nikhila↗

DECOVALEX-2019 (Task E Final Report)

The DECOVALEX Project is an on-going international research collaboration, established in 1992, to advance the understanding and modeling of coupled Thermal (T), Hydrological (H), Mechanical (M) and Chemical (C) processes in geological in geological systems. DECOVALEX was initially motivated by the recognition that prediction of these coupled effects is an essential part of the performance and safety assessment of geologic disposal systems for radioactive waste and spent nuclear fuel. Later it was realized that these processes also play a critical role in other subsurface engineering activities, such as subsurface CO 2 storage, enhanced geothermal systems, and unconventional oil and gas production through hydraulic fracturing. Research teams from many countries (e.g., Canada, China, Czech Republic, Finland, France, Germany, Japan, Republic of Korea, Spain, Sweden, Switzerland, Taiwan, United Kingdom, and the United States) various institutions have participated in the DECOVALEX Project over the years, providing a wide range of perspectives and solutions to these complex problems. These institutions represent radioactive waste management organizations, national research institutes, regulatory agencies, universities, as well as industry and consulting groups. This document is the final report of Task E which was proposed and coordinated by Andra, the National Radioactive Waste Management Agency in France, presenting the technical definitions of the problems studied, approaches applied, achievements made and outstanding issues for future research. The purpose of Task E of the DECOVALEX-2019 project is to investigate upscaling THM modelling from small-scale experiments (some cubic meters) to full-scale experiments (some ten cubic meters) and finally to the scale of the waste repository (cubic kilometers). To achieve this aim, the data of two in-situ heating experiments performed by Andra (the French National Radioactive Waste Management Agency) in the Meuse/Haute-Marne Underground Research Laboratory (MHM URL) have formed the basis for the understanding of the THM behavior of the COx at different scales. The first experiment provided the reference values of the THM parameters by means of a calibration exercise and they were used for a blind prediction and an interpretative analysis of the second one.

58 GEOSCIENCES↗

Unconventional Thermoelectric Materials for Energy Harvesting and Sensing Applications

Heat is an abundant but often wasted source of energy. Thus, harvesting just a portion of this tremendous amount of energy holds significant promise for a more sustainable society. While traditional solid-state inorganic semiconductors have dominated the research stage on thermal-to-electrical energy conversion, carbon-based semiconductors have recently attracted a great deal of attention as potential thermoelectric materials for low-temperature energy harvesting, primarily driven by the high abundance of their atomic elements, ease of processing/manufacturing, and intrinsically low thermal conductivity. This quest for new materials has resulted in the discovery of several new kinds of thermoelectric materials and concepts capable of converting a heat flux into an electrical current by means of various types of particles transporting the electric charge: (i) electrons, (ii) ions, and (iii) redox molecules. This has contributed to expanding the applications envisaged for thermoelectric materials far beyond simple conversion of heat into electricity. This is the motivation behind this review. This work is divided in three sections. In the first section, we present the basic principle of the thermoelectric effects when the particles transporting the electric charge are electrons, ions, and redox molecules and describe the conceptual differences between the three thermodiffusion phenomena. In the second section, we review the efforts made on developing devices exploiting these three effects and give a thorough understanding of what limits their performance. In the third section, we review the state-of-the-art thermoelectric materials investigated so far and provide a comprehensive understanding of what limits charge and energy transport in each of these classes of materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Memo: Waste-to-Energy Potential in Guam

This memo summarizes analysis of the potential applications and associated costs of implementing waste-to-energy technologies in Guam. It examines how these systems could contribute to the island's energy portfolio by converting waste materials into usable power or heat.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Waste-to-Energy Potential in Guam [Slides]

This report presents an overview of the potential applications and associated costs of implementing waste-to-energy technologies in Guam. It examines how these systems could contribute to the island’s energy portfolio by converting waste materials into usable power or heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geomechanical in situ testing of fault reactivation in argillite repositories

Abstract. Pressurization of natural faults as a result of repository-induced effects can lead to their reactivation and permeability generation in case such features are present near disposal tunnels. Potential driving forces for such pressurization are the temperature increase caused by heat-producing high-level radioactive waste and the generation of hydrogen and other gases due to corrosion of engineered materials. We are primarily concerned about pressurization and fault activation in host rocks and faults that have very low natural permeability for pore pressure increases to dissipate, such as the argillite rocks currently investigated in Switzerland, France and other countries. This presentation discusses a series of in situ experiments of fault activation by fluid injection conducted in the argillite rock (Opalinus clay) at the Mont Terri underground research laboratory in Switzerland. A multi-model monitoring test bed was installed at Mont Terri that includes distributed fiber optics for strain, temperature, and acoustics; local fault pore pressure and three-dimensional displacement sensors; active seismic imaging; and passive seismic monitoring. The fault experiments (and their subsequent analysis via hydromechanical modeling) provide a new fundamental understanding of the coupling between pore pressure, fault deformation and permeability generation as a function of time and allow exploring how seismic and aseismic events may impact the integrity of faulted argillite host rock. Our experimental observations demonstrate that significant flow (and transport) can occur along the initially impermeable argillite fault when rupture is activated. However, the fault permeability decreases to almost its pre-activation value when fluid injection ceases and fluid pressure drops. Dilatant slip on the fault plane alone does not explain the observed increase in fault permeability; pressure-induced fault opening also plays a role, favored by the softness of the shale along with the fact that the structure of the fault zone prevents fluids from diffusing into the adjacent damage zone. Rupture initiation and permeability generation is initially aseismic, associated only with an increase in noise level and emerging tremors. Micro-earthquakes are initiated later in the experiments and typically occur away from the fluid-pressurized area. Hydromechanical models show that stress transferred from the initial aseismic deformation can build up to stress criticality and later induce seismic rupture. After presenting the experimental results, we will close the presentation with an outlook to future experimental campaigns using the fault test bed at Mont Terri. We are currently planning a controlled thermal stimulation of the fault, where instead of fluid injection as a trigger mechanism we will heat up the nearby rock volume and measure potential effects on fault stability. Lessons learned from our past and future experiments will help inform the safety assessment of geologic disposal in argillite host rock.

Birkholzer, Jens T.↗

Modeling of thermal pressurization in tight claystone using sequential THM coupling: Benchmarking and validation against in-situ heating experiments in COx claystone

We apply thermoporoelasticity and a sequentially coupling technique for modeling thermally-driven coupled Thermo-Hydro-Mechanical (THM) processes in tight claystone. A THM benchmark case with a corresponding analytic solution for thermoporoelasticity under a constant heat loading verifies the model. Thereafter, two in situ heating experiments are simulated for model validation: a smaller-scale heating experiment (TED experiment) and a larger-scale experiment (ALC experiment) in Callovo-Oxfordian (COx) claystone at the Meuse/Haute-Marne underground research laboratory in France. The model exhibits good performance to match the observed temperature and pore pressure evolution for the smaller-scale TED experiment. For the larger-scale ALC experiment, general trends of thermal-pressurization are captured in the modeling, but pressure is underestimated at some monitoring points during cool-down. This indicates that the THM response in the field may be affected by the variability of rock's properties or irreversible or time-dependent mechanical processes that are not included in the current thermoporoelastic model. The main contributions of this work are as follows: (1) we verify and validate the numerical simulator, TOUGH-FLAC, to be a valuable coupled THM modeling tool; (2) prove that the laboratory determined material parameters can be used as reference values for upscaling experiments. However, to better identify and quantify THM processes with modeling of in situ tests, more emphasize should be dedicated to obtaining high-quality mechanical deformation data.

58 GEOSCIENCES↗

Effect of Mo precursors in Microwave-assisted Methane Dehydroaromatization over Mo/HZSM5 catalysts

Natural gas flaring occurs in remote shale regions due to limited pipeline takeaway capacity. The conversion of the associated natural gas into aromatics in modular microwave reactors is a viable alternative to monetize the wasted gas. Microwaves offer rapid, selective heating in compact reactor systems that can enable on-demand chemical production at the well-site. Mo-HZSM-5 catalysts are widely used for aromatic production, but the location and nature of the active sites are still under debate. This study focuses on the use of 6 different Mo precursors to elucidate insights into the Mo properties that are desirable for BTX production. The catalysts were characterized by different methods (XPS, TPR, Raman, etc) to determine differences in Mo catalytic properties that may affect performance and understand these differences through performance testing under microwave at 700C for methane dehydroaromatization. Metal precursors that enable a better distribution of Mo into the pores and over the surface lead to improved benzene yield, whereas those that limited Mo to primarily the surface suffer rapid deactivation and low benzene yields. Additionally, strong Lewis acidity that arises from the sodium containing precursor drastically shifts the product selectivity towards dehydrogenation, which produces more ethylene and carbon. This catalyst had the highest deactivation constant of all catalysts tested.

gas flaring reduction↗

Can we safely go to 200 °C? An integrated approach to assessing impacts to the engineered barrier system in a high-temperature repository

Abstract. This presentation gives on overview of the complex thermo-hydro-mechanical-chemical (THMC) processes occurring during the disposal of heat-producing high-level radioactive waste in geologic repositories. A specific focus is on the role of compacted bentonite, which is commonly used as an engineered backfill material for emplacement tunnels because of its low permeability, high swelling pressure, and radionuclide retention capacity. Laboratory and field tests integrated with THMC modeling have provided an effective way to deepen our understanding of temperature-related perturbations in the engineered barrier system; however, most of this work has been conducted for maximum temperatures around 100 ∘C. In contrast, some international disposal programs have recently started investigations to understand whether local temperatures in the bentonite of up to 200 ∘C could be tolerated with no significant changes to safety relevant properties. Raising the maximum temperature is attractive for economical and safety reasons but faces the challenge of exposing the bentonite to significant temperature increases. Strong thermal gradients may induce complex moisture transport processes while geochemical processes, such as cementation and perhaps also illitization effects may occur, all of which could strongly affect the bentonite and near-field rock properties. Here, we present initial investigations of repository behavior exposed to strongly elevated temperatures. We will start discussing our current knowledge base for temperature effects in repositories exposed to a maximum temperature of 100 ∘C, based on data and related modeling analysis from a large heater experiment conducted for over 18 years in the Grimsel Test Site in Switzerland. We then show results from coupled THMC simulations of a nuclear waste repository in a clay formation exposed to a maximum temperature of 200 ∘C. We also explore preliminary data from a bench-scale laboratory mock-up experiment, which was designed to represent the strong THMC gradients occurring in a “hot” repository, and we finally touch on a full-scale field heater test to be conducted soon in the Grimsel Test Site underground research laboratory in Switzerland (referred to as HotBENT).

Birkholzer, Jens T. (ORCID:0000000279891912)↗

Virtual Refrigerant Charge Sensing Method for Next-Generation Refrigerant in Residential Heat Pumps

The charge level of refrigerant in heat pump systems significantly affects their operational performance. Virtual refrigerant charge (VRC) sensing technology has been well-established for traditional refrigerants (HFCs and HCFCs) for its low cost compared to physical sensors. However, other than traditional refrigerants, HFOs are increasingly used in next-generation heat pumps; whether these conventional VRC sensing methods remain applicable for heat pump systems utilizing next-generation refrigerants requires further investigation. To address these issues, this study develops a low-cost VRC sensing method for next-generation refrigerant heat pumps used in residential buildings. The developed algorithm is evaluated by using simulation models to evaluate the accuracy, considering an R454B heat pump with a nominal heating capacity of 51K Btu/hr (14.95 kW) as an example, and compared with those of the two reference VRC sensing algorithms. Though the developed VRC sensing algorithm and the two reference methods can accurately predict the charge level for the R454B heat pump system (with mean absolute percentage error for various cooling and heating conditions less than 7%), the developed VRC sensing algorithm uses fewer sensors and improves the overall accuracy for heating conditions by 7.1%, and the accuracy for undercharge cooling conditions 14.2%, compared with a mainstream algorithm. This technology will complement physical leakage detectors, and promote the adoption of next-generation heat pump systems, along with reducing wasted energy and maintenance costs.

Liang, Chenjiyu↗