Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wavefront Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Variable Sampling Mapping

The performance of an optical system (for example, a telescope) is limited by the misalignments and manufacturing imperfections of the optical elements in the system. The impact of these misalignments and imperfections can be quantified by the phase variations imparted on light traveling through the system. Phase retrieval is a methodology for determining these variations. Phase retrieval uses images taken with the optical system and using a light source of known shape and characteristics. Unlike interferometric methods, which require an optical reference for comparison, and unlike Shack-Hartmann wavefront sensors that require special optical hardware at the optical system's exit pupil, phase retrieval is an in situ, image-based method for determining the phase variations of light at the system s exit pupil. Phase retrieval can be used both as an optical metrology tool (during fabrication of optical surfaces and assembly of optical systems) and as a sensor used in active, closed-loop control of an optical system, to optimize performance. One class of phase-retrieval algorithms is the iterative transform algorithm (ITA). ITAs estimate the phase variations by iteratively enforcing known constraints in the exit pupil and at the detector, determined from modeled or measured data. The Variable Sampling Mapping (VSM) technique is a new method for enforcing these constraints in ITAs. VSM is an open framework for addressing a wide range of issues that have previously been considered detrimental to high-accuracy phase retrieval, including undersampled images, broadband illumination, images taken at or near best focus, chromatic aberrations, jitter or vibration of the optical system or detector, and dead or noisy detector pixels. The VSM is a model-to-data mapping procedure. In VSM, fully sampled electric fields at multiple wavelengths are modeled inside the phase-retrieval algorithm, and then these fields are mapped to intensities on the light detector, using the properties of the detector and optical system, for comparison with measured data. Ultimately, this model-to-data mapping procedure enables a more robust and accurate way of incorporating the exit-pupil and image detector constraints, which are fundamental to the general class of ITA phase retrieval algorithms.

Smith, Jeffrey, S.↗

Active figure maintenance control using an optical truss laser metrology system for a space-based far-IR segmented telescope

A two-stage active control approach was developed addressing the figure control problem for a spaceborne FIR telescope, the Precision Segmented Reflectors Focus Moderate Mission Telescope (FMMT). The first active control stage aligns the optical segments based on images; attention is here given to the second stage, active figure maintenance control system, which maintains the alignment of the optical elements between initializations to hold the mirror figure steady while obtaining data and fixes translational and rotational changes of the optical segments induced by long-term thermal drifts of the support structure. Errors are expected to be 10-100 microns at the nodes of the primary backup structure over the course of an orbit. An rms performance of 0.8 microns of wavefront error can be expected during the maintenance function based on specified nominal sensor noises, actuator accuracies, and system environments. A performance of less than 0.3 microns rms can be expected, based on advanced components.

Lau, Kenneth↗

RST Optical Telescope Integration and Test Preparation

The OTA for the Nancy Grace Roman Space Telescope includes the primary mirror, secondary mirror, and aft optics for guiding light into the Wide Field Instrument and the Coronagraph Instrument. The telescope is taking shape as the tested optical mirror assemblies are integrated. The assemblies have been thermal cycled to the cold temperatures for infrared operation, load tested to launch loads, vibration tested, and optically tested. Testing included launch-level vibration testing of the 2.4-meter light-weighted primary mirror assembly. In addition, the telescope control electronics (TCE) box has been fully assembled and the environmental testing of the TCE is progressing. Pictures and descriptions of the integration and test progress are provided, along with performance results measured at these levels of assemblies. Planning and test equipment preparation for the telescope thermal vacuum testing continues including plans to take advantage of the large dynamic range available with focus diversity phase retrieval and a Shack-Hartmann wavefront sensor for the gravity-sagged primary mirror.

Tony L Whitman↗

Actuated Hybrid Mirror Telescope

The figure depicts the planned Actuated Hybrid Mirror Telescope (AHMT), which is intended to demonstrate a new approach to the design and construction of wide-aperture spaceborne telescopes for astronomy and Earth science. This technology is also appropriate for Earth-based telescopes. The new approach can be broadly summarized as using advanced lightweight mirrors that can be manufactured rapidly at relatively low cost. More specifically, it is planned to use precise replicated metallic nanolaminate mirrors to obtain the required high-quality optical finishes. Lightweight, dimensionally stable silicon carbide (SiC) structures will support the nanolaminate mirrors in the required surface figures. To enable diffraction- limited telescope performance, errors in surface figures will be corrected by use of mirror-shape-control actuators that will be energized, as needed, by a wave-front-sensing and control system. The concepts of nanolaminate materials and mirrors made from nanolaminate materials were discussed in several previous NASA Tech Briefs articles. Nanolaminates constitute a relatively new class of materials that can approach theoretical limits of stiffness and strength. Nanolaminate mirrors are synthesized by magnetron sputter deposition of metallic alloys and/or compounds on optically precise master surfaces to obtain optical-quality reflector surfaces backed by thin shell structures. As an integral part of the deposition process, a layer of gold that will constitute the reflective surface layer is deposited first, eliminating the need for a subsequent and separate reflective-coating process. The crystallographic textures of the nanolaminate will be controlled to optimize the performance of the mirror. The entire deposition process for making a nanolaminate mirror takes less than 100 hours, regardless of the mirror diameter. Each nanolaminate mirror will be bonded to its lightweight SiC supporting structure. The lightweight nanolaminate mirrors and SiC supporting structures will be fabricated from reusable master molds. The mirror-shape-control actuators will be low-power, high-capacitance lead magnesium niobate electrostrictive actuators that will be embedded in the SiC structures. The mode of operation of these actuators will be such that once power was applied, they will change in length and once power was removed, they will maintain dimensional stability to nanometer precision. This mode of operation will enable the use of low-power, minimally complex electronic control circuitry. The wave-front-sensing and control system will be designed and built according to a two-stage architecture. The first stage will be implemented by a Shack- Hartmann (SH) sensor subsystem, which will provide a large capture range. The second, higher-performance stage will be implemented by an image-based wave-front-sensing subsystem that will include a phase-retrieval camera (PRC), and will utilize phase retrieval and other techniques to measure wavefront error directly. Phase retrieval is a process in which multiple images of an unresolved object are iterated to estimate the phase of the optical system that acquired the images. The combination of SH and phase-retrieval sensors will afford the virtues of both a dynamic range of 105 and an accuracy of <10 nm.

Hickey, Gregory↗

Coherent phasing of segmented mirrors

The technical issues associated with a coherently phased segmented mirror can be divided into two types. The first involves the issues of manufacturing the surface quality of the mirror segments themselves (coherent phasing of individual segments). The second involves assembly issues of initializing in 1 G and retaining in 0 G an aggregate segmented mirror (coherent phasing between individual segments). Using a rectangular coordinate system at the vertex of a mirror segment, the rigid body motions are the six translational and rotational degrees of freedom. A first cut primary mirror wavefront error budget is presented. For a minimum operational wavelength of 30 micrometers, the derived values from the budget are: segment surface quality (0.45 micrometers RMS), radius mismatch (50 PPM), segment piston error (1.3 micrometers, segment tip/tilt error (0.6 microrad). Either active or passive segmented mirrors can be addressed, but if the surface quality of the off-axis segment and the radius matching requirements can be passively met, then only segment alignment need be sensed and controlled during operation in orbit. For the active mirror case, dimensional stability of the mirror material during operation is a key factor in establishing the degree of active figure control required.

Jones, Peter A.↗

The precision segmented reflectors: Moderate mission figure control subsystem

A system concept for a space based segmented reflector telescope figure control subsystem is described. The concept employs a two phase architecture in which figure initialization and figure maintenance are independent functions. Figure initialization is accomplished by image sharpening using natural reference targets. Figure maintenance is performed by monitoring the relative positions and alignments of the telescope components using an optical truss. Actuation is achieved using precision positioners. Computer simulation results of figure initialization by pairwise segment coalignment/cophasing and simulated annealing are presented along with figure maintenance results using a wavefront error regulation algorithm. Both functions are shown to perform at acceptable levels for the class of submillimeter telescopes that are serving as the focus of this technology development effort. Component breadboard work as well as plans for a system testbed are discussed.

Sevaston, G.↗

Space Adaptation of Active Mirror Segment Concepts

This report summarizes the results of a three year effort by Blue Line Engineering Co. to advance the state of segmented mirror systems in several separate but related areas. The initial set of tasks were designed to address the issues of system level architecture, digital processing system, cluster level support structures, and advanced mirror fabrication concepts. Later in the project new tasks were added to provide support to the existing segmented mirror testbed at Marshall Space Flight Center (MSFC) in the form of upgrades to the 36 subaperture wavefront sensor. Still later, tasks were added to build and install a new system processor based on the results of the new system architecture. The project was successful in achieving a number of important results. These include the following most notable accomplishments: 1) The creation of a new modular digital processing system that is extremely capable and may be applied to a wide range of segmented mirror systems as well as many classes of Multiple Input Multiple Output (MIMO) control systems such as active structures or industrial automation. 2) A new graphical user interface was created for operation of segmented mirror systems. 3) The development of a high bit rate serial data loop that permits bi-directional flow of data to and from as many as 39 segments daisy-chained to form a single cluster of segments. 4) Upgrade of the 36 subaperture Hartmann type Wave Front Sensor (WFS) of the Phased Array Mirror, Extendible Large Aperture (PAMELA) testbed at MSFC resulting in a 40 to 5OX improvement in SNR which in turn enabled NASA personnel to achieve many significant strides in improved closed-loop system operation in 1998. 5) A new system level processor was built and delivered to MSFC for use with the PAMELA testbed. This new system featured a new graphical user interface to replace the obsolete and non-supported menu system originally delivered with the PAMELA system. The hardware featured Blue Line's new stackable processing system which included fiber optic data links, a WFS digital interface, and a very compact and reliable electronics package. The project also resulted in substantial advances in the evolution of concepts for integrated structures to be used to support clusters of segments while also serving as the means to distribute power, timing, and data communications resources. A prototype cluster base was built and delivered that would support a small array of 7 cm mirror segments. Another conceptual design effort led to substantial progress in the area of laminated silicon mirror segments. While finished mirrors were never successfully produced in this exploratory effort, the basic feasibility of the concept was established through a significant amount of experimental development in microelectronics processing laboratories at the University of Colorado in Colorado Springs. Ultimately lightweighted aluminum mirrors with replicated front surfaces were produced and delivered as part of a separate contract to develop integrated segmented mirror assemblies. Overall the project was very successful in advancing segmented mirror system architectures on several fronts. In fact, the results of this work have already served as the basic foundation for the system architectures of several projects proposed by Blue Line for different missions and customers. These include the NMSD and AMSD procurements for NASA's Next Generation Space Telescope, the HET figure maintenance system, and the 1 meter FAST telescope project.

Ames, Gregory H.↗

Optical correlators for automated rendezvous and capture

The paper begins with a description of optical correlation. In this process, the propagation physics of coherent light is used to process images and extract information. The processed image is operated on as an area, rather than as a collection of points. An essentially instantaneous convolution is performed on that image to provide the sensory data. In this process, an image is sensed and encoded onto a coherent wavefront, and the propagation is arranged to create a bright spot of the image to match a model of the desired object. The brightness of the spot provides an indication of the degree of resemblance of the viewed image to the mode, and the location of the bright spot provides pointing information. The process can be utilized for AR&C to achieve the capability to identify objects among known reference types, estimate the object's location and orientation, and interact with the control system. System characteristics (speed, robustness, accuracy, small form factors) are adequate to meet most requirements. The correlator exploits the fact that Bosons and Fermions pass through each other. Since the image source is input as an electronic data set, conventional imagers can be used. In systems where the image is input directly, the correlating element must be at the sensing location.

Juday, Richard D.↗

SIM Configuration Evolution

The Space Interferometry Mission (SIM) is a space-based 10 m baseline Michelson interferometer. Planned for launch in 2005 aboard a Delta III launch vehicle, or equivalent, its primary objective is to measure the positions of stars and other celestial objects with an unprecedented accuracy of 4 micro arc seconds. With such an instrument, tremendous advancement can be expected in our understanding of stellar and galactic dynamics. Using triangulation from opposite sides of the orbit around the sun (i.e. by using parallax) one can measure the distance to any observable object in our galaxy. By directly measuring the orbital wobble of nearby stars, the mass and orbit of planets can be determined over a wide range of parameters. The distribution of velocity within nearby galaxies will be measurable. Observations of these and other objects will improve the calibration of distance estimators by more than an order of magnitude. This will permit a much better determination of the Hubble Constant as well as improving our overall understanding of the evolution of the universe. SIM has undergone several transformations, especially over the past year and a half since the start of Phase A. During this phase of a project, it is desirable to perform system-level trade studies, so the substantial evolution of the design that has occurred is quite appropriate. Part of the trade-off process has addressed two major underlying architectures: SIM Classic; and Son of SIM. The difference between these two architectures is related to the overall arrangement of the optical elements and the associated metrology system. Several different configurations have been developed for each architecture. Each configuration is the result of design choices that are influenced by many competing considerations. Some of the more important aspects will be discussed. The Space Interferometry Mission has some extremely challenging goals: millikelvin thermal stability, nanometer stabilization of optics, picometer measurement of wavefront, and others. In order to meet these goals, a significant amount of technological development is required. Although there has been a program operating for about a decade developing technologies specifically to address the challenges of space-based interferometry, there still remains a tremendous effort to achieve the incredible accuracy required of SIM. The projected viability of some of these areas has influenced design choices during the evolution of the many configurations that have been developed. For instance, the perceived complexity of the IR laser metrology system used to measure and control the positions of key optical elements was the strongest discriminator between the two architectures, and led to a decision to select SOS rather than Classic in early 1998. More recently, an appreciation of the sensitivity to beam-walk within the SOS architecture is forcing a reconsideration of that decision. At the time of submission of this abstract, there is some hope that a full-aperture metrology system may alleviate this issue. In addition to describing the current configuration of SIM, the influence of a few selected areas on the evolution of the configuration will be discussed.

Aaron, Kim M.↗

Instrument for Achieving High Angular Resolution on the Infrared Telescope

Aberrations in stellar images caused by the atmosphere sets a significant limit on angular resolution in ground based astronomy. The largest of these aberrations is the image motion or wavefront tilt. Since the image motion is random it causes a blurring of the image, and this causes a blurring of the image from 0.3 arcseconds to about 0.7 arcseconds. The purpose of the tip-tilt project was to devise a system for the NASA Infrared Telescope Facility that would measure the image movement and correct it by rapidly tilting a mirror in two axes (tip and tilt). The system would involve building a CCD sensor package to measure the image motion, a new top end for the telescope to hold the tip-tilt mirror, a control system, and software. The system was designed to correct images for the facility camera, NSFCAM, and for the facility spectrometer, SPEX. Both of these instruments are equipped with a cold beamsplitter to feed the sensor package.

Hall, Donald N. B.↗

Chiral Kirigami for Bend‐Tolerant Reconfigurable Hologram with Continuously Variable Chirality Measures

Abstract Despite the commonality of static holograms, the holography with multiple information layers and reconfigurable grey‐scale images at communication frequencies remain a confluence of scientific challenges. One well‐known difficulty is the simultaneous modulation of phase and amplitude of electromagnetic wavefronts with a high modulation depth. A less appreciated challenge is scrambling of the information and images with hologram bending. Here, this work shows that chirality‐guided pixelation of plasmonic kirigami sheets enables tunable multiplexed holography at terahertz (THz) frequencies. The convex and concave structures with slanted Au strips exhibit gradual variations in geometries facilitating modulation of light ellipticity reaching 40 deg. Real‐time switching of 3D images of the letter “ M ” and the Mona Lisa demonstrates the possibility of complex grey‐scale information content and importance of continuously variable mirror asymmetry. Microscale chirality measures of each pixel experiences little change with bending while retaining controllable reconfigurability upon stretching, which translates to remarkable resilience of chiral holograms to bending. Simplicity of their design with local chirality measures opens the door to information technologies with fault‐tolerant THz encryption, wearable holographic devices, and new communication technologies.

36 MATERIALS SCIENCE↗

Phase Change Materials for Photonics in NASA Science and Space Missions

Phase change materials (PCMs) such as Ge2Sb2Te5, Ge2Sb2Se4Te1, and Sb2S3have recently emerged as a promising platform to control light on-chip due to their fast, dramatic, and reversible change in refractive index. Significant technical progress in the field has been achieved in terms of improving optical transparency, controlling PCMs both optically and electrically, and integrating with complex photonic circuits, leading to exciting applications. When PCMs are mated with metasurfaces, devices are capable of controlling the phase and amplitude of propagating light with arrays of subwavelength structures. These enhance tunability and reconfigurability and continue to redefine the boundaries of optical sciences. PCM-based metasurface optics also help to accelerate the adoption of new architectures with reduced size, weight, and power (SWaP) for science and space mission platforms at NASA. In this talk, I will introduce two NASA-lead PCM photonic projects: 1. P-ACTIVE (PCM-based actively tunable filter) for broad imaging and sensing applications – from probing molecular vibrations in chemical species to detecting radiant thermal signatures of the space launch system. 2. PROWESS (Phase change reconfigurable optical wavefront synthesis system) as a beam steerer for both Earth and space LiDAR and free space optical communication applications. From this seminar, the attendees will be exposed not only to PCM-based photonic technologies but also NASA missions including the MISSE (Materials on the International Space Station Experiment) test campaign that was conducted to expose PCMs and PCM-based metasurfaces in space for 6 months in 2022.

phase change material↗

Pupil Alignment Considerations for Large, Deployable Space Telescopes

For many optical systems the properties and alignment of the internal apertures and pupils are not critical or controlled with high precision during optical system design, fabrication or assembly. In wide angle imaging systems, for instance, the entrance pupil position and orientation is typically unconstrained and varies over the system s field of view in order to optimize image quality. Aperture tolerances usually do not receive the same amount of scrutiny as optical surface aberrations or throughput characteristics because performance degradation is typically graceful with misalignment, generally only causing a slight reduction in system sensitivity due to vignetting. But for a large deployable space-based observatory like the James Webb Space Telescope (JWST), we have found that pupil alignment is a key parameter. For in addition to vignetting, JWST pupil errors cause uncertainty in the wavefront sensing process that is used to construct the observatory on-orbit. Furthermore they also open stray light paths that degrade the science return from some of the telescope s instrument channels. In response to these consequences, we have developed several pupil measurement techniques for the cryogenic vacuum test where JWST science instrument pupil alignment is verified. These approaches use pupil alignment references within the JWST science instruments; pupil imaging lenses in three science instrument channels; and unique pupil characterization features in the optical test equipment. This will allow us to verify and crosscheck the lateral pupil alignment of the JWST science instruments to approximately 1-2% of their pupil diameters.

Bos, Brent J.↗

NASA Tech Briefs, July 2012

Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage.

Source record↗

Nanoscale strain wave generation by a piezoelectric grating from polar vortices

Nanostructures formed by spontaneously broken symmetry have provided new ways to manipulate quantum states. Specifically, topological structures with periodic spatial ordering, such as polar vortices and skyrmions, can be ideal hosts for creating engineered responses in both spatial and frequency domains. So far, however, only a few examples of such hierarchical engineering have been reported in the literature. Here we demonstrate that the spatially modulated piezoelectric response of a polar vortex structure can create strain waves with a characteristic nanoscale wavefront. Using time-resolved pump–probe resonant X-ray scattering and diffraction measurements, coupled with dynamical phase-field simulations, we show that the piezoelectric modulation of the spontaneously formed polar vortex crystal functions as an acoustic diffraction grating. This system converts incoming laterally uniform strain waves into outgoing waves with a characteristic sub-terahertz frequency, driven by an intrinsic excitation of the polar vortex crystal. Moreover, our phase-field simulations suggest that the dynamic mechanical displacements exhibiting vortex textures are generated from both space- and time-varying piezoelectric responses. Our findings illustrate a new method for generating nanoscale strain waves with unique spatial textures by tuning the hierarchical order of polar topologies to engineer new collective modes, allowing for a wide range of control through the topological lattice.

ferroelectrics↗

NASA Tech Briefs, September 2013

Topics include: ISS Ammonia Leak Detection Through X-Ray Fluorescence; A System for Measuring the Sway of the Vehicle Assembly Building; Fast, High-Precision Readout Circuit for Detector Arrays; Victim Simulator for Victim Detection Radar; Hydrometeor Size Distribution Measurements by Imaging the Attenuation of a Laser Spot; Quasi-Linear Circuit; High-Speed, High-Resolution Time-to-Digital Conversion; Li-Ion Battery and Supercapacitor Hybrid Design for Long Extravehicular Activities; Ultrasonic Low-Friction Containment Plate for Thermal and Ultrasonic Stir Weld Processes; High-Powered, Ultrasonically Assisted Thermal Stir Welding; Next-Generation MKIII Lightweight HUT/Hatch Assembly; Centrifugal Sieve for Gravity-Level-Independent Size; Segregation of Granular Materials; Ion Exchange Technology Development in Support of the Urine Processor Assembly; Nickel-Graphite Composite Compliant Interface and/or Hot Shoe Material; UltraSail CubeSat Solar Sail Flight Experiment; Mechanism for Deploying a Long, Thin-Film Antenna From a Rover; Counterflow Regolith Heat Exchanger; Acquisition and Retaining Granular Samples via a Rotating Coring Bit; Very-Low-Cost, Rugged Vacuum System; Medicine Delivery Device With Integrated Sterilization and Detection; FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D; Multimode Directional Coupler for Utilization of Harmonic Frequencies from TWTAs; Dual-Polarization, Multi-Frequency Antenna Array for use with Hurricane Imaging Radiometer; Complementary Barrier Infrared Detector (CBIRD) Contact Methods; Autonomous Control of Space Nuclear Reactors; High-Power, High-Speed Electro-Optic Pockels Cell Modulator; Covariance Analysis Tool (G-CAT) for Computing Ascent, Descent, and Landing Errors; Enigma Version 12; Micrometeoroid and Orbital Debris (MMOD) Shield Ballistic Limit Analysis Program; Spitzer Telemetry Processing System; Planetary Protection Bioburden Analysis Program; Wing Leading Edge RCC Rapid Response Damage Prediction Tool (IMPACT2); ISSM: Ice Sheet System Model; Automated Loads Analysis System (ATLAS); Integrated Main Propulsion System Performance Reconstruction Process/Models. Phoenix Telemetry Processor; Contact Graph Routing Enhancements Developed in ION for DTN; GFEChutes Lo-Fi; Advanced Strategic and Tactical Relay Request Management for the Mars Relay Operations Service; Software for Generating Troposphere Corrections for InSAR Using GPS and Weather Model Data; Ionospheric Specifications for SAR Interferometry (ISSI); Implementation of a Wavefront-Sensing Algorithm; Sally Ride EarthKAM - Automated Image Geo-Referencing Using Google Earth Web Plug-In; Trade Space Specification Tool (TSST) for Rapid Mission Architecture (Version 1.2); Acoustic Emission Analysis Applet (AEAA) Software; Memory-Efficient Onboard Rock Segmentation; Advanced Multimission Operations System (ATMO); Robot Sequencing and Visualization Program (RSVP); Automating Hyperspectral Data for Rapid Response in Volcanic Emergencies; Raster-Based Approach to Solar Pressure Modeling; Space Images for NASA JPL Android Version; Kinect Engineering with Learning (KEWL); Spacecraft 3D Augmented Reality Mobile App; MPST Software: grl_pef_check; Real-Time Multimission Event Notification System for Mars Relay; SIM_EXPLORE: Software for Directed Exploration of Complex Systems; Mobile Timekeeping Application Built on Reverse-Engineered JPL Infrastructure; Advanced Query and Data Mining Capabilities for MaROS; Jettison Engineering Trajectory Tool; MPST Software: grl_suppdoc; PredGuid+A: Orion Entry Guidance Modified for Aerocapture; Planning Coverage Campaigns for Mission Design and Analysis: CLASP for DESDynl; and Space Place Prime.

Source record↗

Transverse Pupil Shifts for Adaptive Optics Non-Common Path Calibration

A simple new way of obtaining absolute wavefront measurements with a laboratory Fizeau interferometer was recently devised. In that case, the observed wavefront map is the difference of two cavity surfaces, those of the mirror under test and of an unknown reference surface on the Fizeau s transmission flat. The absolute surface of each can be determined by applying standard wavefront reconstruction techniques to two grids of absolute surface height differences of the mirror under test, obtained from pairs of measurements made with slight transverse shifts in X and Y. Adaptive optics systems typically provide an actuated periscope between wavefront sensor (WFS) and commonmode optics, used for lateral registration of deformable mirror (DM) to WFS. This periscope permits independent adjustment of either pupil or focal spot incident on the WFS. It would be used to give the required lateral pupil motion between common and non-common segments, analogous to the lateral shifts of the two phase contributions in the lab Fizeau. The technique is based on a completely new approach to calibration of phase. It offers unusual flexibility with regard to the transverse spatial frequency scales probed, and will give results quite quickly, making use of no auxiliary equipment other than that built into the adaptive optics system. The new technique may be applied to provide novel calibration information about other optical systems in which the beam may be shifted transversely in a controlled way.

Bloemhof, Eric E.↗

Measuring Segmented Primary Mirror WFE in the Presence of Vibration and Thermal Drift on the Light-Weighted JWST

The light-weighted design of the Optical Telescope Element (OTE) of the James Webb Telescope (JWST) leads to additional sensitivity to vibration from the ground - an important consideration to the measurement uncertainty of the wavefront error (WFE) in the primary mirror. Furthermore, segmentation of the primary mirror leads to rigid-body movements of segment areas in the WFE. The ground vibrations are minimized with modifications to the test facility, and by the architecture of the equipment supporting the load. Additional special test equipment (including strategically placed isolators, tunable mass dampers, and cryogenic magnetic dampers) mitigates the vibration and the response sensitivity before reaching the telescope. A multi-wavelength interferometer is designed and operated to accommodate the predicted residual vibration. Thermal drift also adds to the measurement variation. Test results of test equipment components, measurement theory, and finite element analysis combine to predict the test uncertainty in the future measurement of the primary mirror. The vibration input to the finite element model comes from accelerometer measurements of the facility with the environmental control pumps operating. One of the isolators have been built and tested to validate the dynamic performance. A preliminary model of the load support equipment and the OTE with the Integrated Science Instrument Module (ISIM) is complete. The performance of the add-on dampers have been established in previous applications. And operation of the multi-wavelength interferometer was demonstrated on a scaled hardware version of the JWST in an environment with vibration and thermal drift.

Whitman, Tony L.↗