Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Thermo-Mechanical Shock, X-Ray Transport and Radiation Response Analysis Experiments on NIF

The study of x-ray induced rapid heating and the resulting material responses - (thermomechanical shock (TMS) and thermo-structural response (TSR)) - is important to our understanding of material behavior in extreme environments. A series of high conversion efficiency (XRCE) x-ray sources have been developed for the NIF laser facility ranging in fluence and spectral content. In conjunction with source development, we have developed a new XTRRA (X-ray Transport and Radiation Response Analysis) test cassette to hold a set of samples, each at equal distance from target chamber center (TCC) where the x-ray source is placed. Design and performance details of the x-ray sources is discussed elsewhere. Here, we describe the development and use of this TMS XTRRA test cassette. The XTRRA test cassette is a snout mounted on a NIF Diagnostic Instrument Manipulator (DIM) designed to position six samples equidistant from the x-ray source to assure uniform irradiation of all samples. Photon Displacement interferometry (PDI) is used to measure the displacement of the rear surface of each sample resulting from x-ray exposure on the front of the sample. This will help determine the x-ray generated impulse on the sample. The samples are retrieved from the snout after the shot for inspection and post-shot analysis including the measurement of sample ablated mass and engineering tests examining changes in the material structure. The data from experiments are compared to predictions from LLNL’s ASC codes and used to inform models implemented in these codes. Thus, XRCE x-ray sources with the XTRRA snout at the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory provide the ability to expose a broad range of material samples directly to high x-ray fluence, measure shock transits, and recover the sample for further analysis post-shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of molecular resonant double-core excitation driven by intense X-ray pulses

The ultrashort and intense pulses of X-rays produced at X-ray free electron lasers (XFELs) have enabled unique experiments on the atomic level structure and dynamics of matter, with time-resolved studies permitted in the femto- and attosecond regimes. To fully exploit them, it is paramount to obtain a comprehensive understanding of the complex nonlinear interactions that can occur at such extreme X-ray intensities. Herein, we report on the experimental observation of a resonant double-core excitation scheme in N 2 , where two 1σ core-level electrons are resonantly promoted to unoccupied 1π$^*_g$ molecular orbitals by a single few-femtosecond broad-bandwidth XFEL pulse. The production of these neutral two-site double core hole states is evidenced through their characteristic decay channels, which are observed in good agreement with high-level theoretical calculations. Such multi-core excitation schemes, benefiting from the high interaction cross sections and state- and site-selective nature of resonant X-ray interactions, should be generally accessible in XFEL irradiated molecules, and provide interesting opportunities for chemical analysis and for monitoring ultrafast dynamic processes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Enhanced analysis of experimental x-ray spectra through deep learning

X-ray spectroscopic data from high-energy-density laser-produced plasmas has long required thorough, time-consuming analysis to extract meaningful source conditions. There are often confounding factors due to rapidly evolving states and finite spatial gradients (e.g., the existence of multi-temperature, multi-density, multi-ionization states, etc.) that make spectral measurements and analysis difficult. Here, in this paper, we demonstrate how deep learning can be applied to enhance x-ray spectral data analysis in both speed and intricacy. Neural networks (NNs) are trained on ensemble atomic physics simulations so that they can subsequently construct a model capable of extracting plasma parameters directly from experimental spectra. Through deep learning, the models can extract temperature distributions as opposed to single or dual temperature/density fits from standard trial-and-error atomic modeling at a significantly reduced computational cost compared to traditional trial-and-error methods. These NNs are envisioned to be deployed with high repetition rate x-ray spectrometers in order to provide detailed real-time analysis of experimental spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deformation of binary and boron-doped Ni 3 Al alloys at high pressures studied with synchrotron x-ray diffraction

In situ x-ray synchrotron diffraction experiments were carried out on nickel-based high-strength superalloys under pressure to understand their deformation mechanism using a diamond anvil cell (DAC). Radial x-ray diffraction determines the room-temperature equations of state and yield strengths of binary Ni 3 Al alloy and 500 ppm boron-doped Ni 3 Al to pressures of 20 and 46 GPa, respectively. Crystallographic preferred orientations observed in these superalloys due to anisotropic stress field in DAC indicate the onset of plastic deformation. Inverse pole figure analysis reveals that the underlying deformation mechanisms change from an octahedral slip to a simultaneous activation of octahedral and cube slips upon doping with boron. The yield-strength values were found to increase with pressure and are comparable to those determined from axial diffraction experiments. The results indicate that the yield strength of Ni 3 Al:B is about 0.5 GPa higher (at pressures below 20 GPa) due to grain boundary strengthening by boron. It is shown that due to high elastic anisotropy of Ni 3 Al alloy, the yield-strength estimations from diffraction experiments strongly depend on the micromechanical model used to convert the measured elastic strains into stresses.

42 ENGINEERING↗

Characterizing the X-Ray Emission of Intermediate-mass Pre-main-sequence Stars

We use X-ray and infrared observations to study the properties of three classes of young stars in the Carina Nebula: intermediate-mass (2–5 M {sub ⊙}) pre-main-sequence stars (IMPS; i.e., intermediate-mass T Tauri stars), late-B and A stars on the zero-age main sequence (AB), and lower-mass T Tauri stars (TTS). We divide our sources among these three subclassifications and further identify disk-bearing young stellar objects versus diskless sources with no detectable infrared (IR) excess emission using IR (1–8 μm) spectral energy distribution modeling. We then perform X-ray spectral fitting to determine the hydrogen-absorbing column density (N {sub H}), absorption-corrected X-ray luminosity (L {sub X}), and coronal plasma temperature (kT) for each source. We find that the X-ray spectra of both IMPS and TTS are characterized by similar kT and N {sub H}, and on average L {sub X}/L {sub bol} ~ 4 × 10{sup -4}. IMPS are systematically more luminous in X-rays (by ~0.3 dex) than all other subclassifications, with median L {sub X} = 2.5 × 10{sup 31} erg s{sup -1}, while AB stars of similar masses have X-ray emission consistent with TTS companions. These lines of evidence converge on a magnetocoronal flaring source for IMPS X-ray emission, a scaled-up version of the TTS emission mechanism. IMPS therefore provide powerful probes of isochronal ages for the first ~10 Myr in the evolution of a massive stellar population, because their intrinsic, coronal X-ray emission decays rapidly after they commence evolving along radiative tracks. We suggest that the most luminous (in both X-rays and IR) IMPS could be used to place empirical constraints on the location of the intermediate-mass stellar birth line.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of diamond sensors for a high-flux, high-rate X-ray pass-through diagnostic

X-ray free-electron lasers (XFELs) deliver pulses of coherent X-rays on the femtosecond time scale, with potentially high repetition rates. While XFELs provide high peak intensities, both the intensity and the centroid of the beam fluctuate strongly on a pulse-to-pulse basis, motivating high-rate beam diagnostics that operate over a large dynamic range. The fast drift velocity, low X-ray absorption and high radiation tolerance properties of chemical vapour deposition diamonds make these crystals a promising candidate material for developing a fast (multi-GHz) pass-through diagnostic for the next generation of XFELs. A new approach to the design of a diamond sensor signal path is presented, along with associated characterization studies performed in the XPP endstation of the LINAC Coherent Light Source (LCLS) at SLAC. Qualitative charge collection profiles (collected charge versus time) are presented and compared with those from a commercially available detector. Quantitative results on the charge collection efficiency and signal collection times are presented over a range of approximately four orders of magnitude in the generated electron–hole plasma density.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parallel Broadband Femtosecond Reflection Spectroscopy at a Soft X-Ray Free-Electron Laser

X-ray absorption spectroscopy (XAS) and the directly linked X-ray reflectivity near absorption edges yield a wealth of specific information on the electronic structure around the resonantly addressed element. Observing the dynamic response of complex materials to optical excitations in pump–probe experiments requires high sensitivity to small changes in the spectra which in turn necessitates the brilliance of free electron laser (FEL) pulses. However, due to the fluctuating spectral content of pulses generated by self-amplified spontaneous emission (SASE), FEL experiments often struggle to reach the full sensitivity and time-resolution that FELs can in principle enable. Here, we implement a setup which solves two common challenges in this type of spectroscopy using FELs: First, we achieve a high spectral resolution by using a spectrometer downstream of the sample instead of a monochromator upstream of the sample. Thus, the full FEL bandwidth contributes to the measurement at the same time, and the FEL pulse duration is not elongated by a monochromator. Second, the FEL beam is divided into identical copies by a transmission grating beam splitter so that two spectra from separate spots on the sample (or from the sample and known reference) can be recorded in-parallel with the same spectrometer, enabling a spectrally resolved intensity normalization of pulse fluctuations in pump–probe scenarios. We analyze the capabilities of this setup around the oxygen K- and nickel L-edges recorded with third harmonic radiation of the free electron laser in Hamburg (FLASH), demonstrating the capability for pump–probe measurements with sensitivity to reflectivity changes on the per mill level.

36 MATERIALS SCIENCE↗

Toward ultrafast soft x-ray spectroscopy of organic photovoltaic devices

Novel ultrafast x-ray sources based on high harmonic generation and at x-ray free electron lasers are opening up new opportunities to resolve complex ultrafast processes in condensed phase systems with exceptional temporal resolution and atomic site specificity. In this perspective, we present techniques for resolving charge localization, transfer, and separation processes in organic semiconductors and organic photovoltaic devices with time-resolved soft x-ray spectroscopy. We review recent results in ultrafast soft x-ray spectroscopy of these systems and discuss routes to overcome the technical challenges in performing time-resolved x-ray experiments on photosensitive materials with poor thermal conductivity and low pump intensity thresholds for nonlinear effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of Bright Soft X-ray Laser Beams (Final Report)

The project goal was to demonstrate new compact soft x-ray lasers emitting high energy ultrashort pulses at shorter wavelengths and increased repetition rates by amplification in atomic transitions in high density laser-created plasmas. To demonstrate these lasers we developed new high power solid state lasers. The project succeeded in demonstrating the shortest wavelength compact soft x-ray laser to date, 6.85 nm wavelength, and the highest repetition rate table-top soft x-ray laser, 400 Hz. We also applied these compact soft x-ray laser sources to determine the composition of materials with nanoscale resolution using a new technique that combines soft x-ray laser ablation with mass spectrometry, and we demonstrated that these lasers are capable of acquiring nanoscale resolution holograms with picosecond time resolution. The combination of an increased pumping efficiency with increased repetition rates can yield soft x-ray laser beams with an unprecedented average power on a table-top for applications demanding a high photon flux. We have demonstrated that the efficiency of plasma-based laser-pumped soft x-ray lasers can be significantly increased by detailed pulse shaping of the pump laser using a new pulse synthesizer. Results include the demonstration of 18.9 nm wavelength laser operation at a record 400 Hz repetition rate, and the extension of repetitive gain-saturated plasma-based table-top x-ray lasers to the shortest wavelength to date, 6.85 nm. Laser amplification was also observed at wavelengths as short at 5.8 nm by isolectronic scaling in Ni-like lanthanide ions. We have also conducted simulations to explore the possibility of demonstrating gain saturated atomic x-ray lasers near the carbon K-edge, in the “carbon window” for the first time. The work conducted under this program also includes the use of compact soft x-ray lasers in applications to problems of chemical interest, such as isotopic composition mapping of micron-size uranium particles with nanoscale resolution, and nanoscale resolution depth profiling analysis of CoNCN-coated electrodes for water oxidation catalysis. We also demonstrated single-shot high resolution soft x-ray Fourier transform holography over a broad 7 µm diameter field of view with ~ 5 ps temporal resolution.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of Extinction on Quasar Luminosity Distances Determined from UV and X-Ray Flux Measurements

Abstract In Khadka et al., a sample of X-ray-detected reverberation-mapped quasars was presented and applied for the comparison of cosmological constraints inferred using two well-established relations in active galactic nuclei—the X-ray/UV luminosity ( L X – L UV ) relation and the broad-line region radius–luminosity ( R – L ) relation. L X – L UV and R – L luminosity distances to the same quasars exhibit a distribution of their differences that is generally asymmetric and positively shifted for the six cosmological models we consider. We demonstrate that this behavior can be interpreted qualitatively as arising as a result of the dust extinction of UV/X-ray quasar emission. We show that the extinction always contributes to the nonzero difference between L X – L UV -based and R – L -based luminosity distances and we derive a linear relationship between the X-ray/UV color index E X −UV and the luminosity-distance difference, which also depends on the value of the L X – L UV relation slope. Taking into account the median and the peak values of the luminosity-distance difference distributions, the average X-ray/UV color index falls in the range of E ¯ X − UV = 0.03 – 0.28 mag for the current sample of 58 sources. This amount of extinction is typical for the majority of quasars and can be attributed to the circumnuclear and interstellar media of host galaxies. After applying the standard hard X-ray and far-UV extinction cuts, heavily extincted sources are removed but overall the shift toward positive values persists. The effect of extinction on luminosity distances is more pronounced for the L X – L UV relation since the extinction of UV and X-ray emissions both contribute.

Astronomy & Astrophysics↗

The frequency of extreme X-ray variability for radio-quiet quasars

ABSTRACT We analyse 1598 serendipitous Chandra X-ray observations of 462 radio-quiet quasars to constrain the frequency of extreme amplitude X-ray variability that is intrinsic to the quasar corona and innermost accretion flow. The quasars in this investigation are all spectroscopically confirmed, optically bright (mi ≤ 20.2), and contain no identifiable broad absorption lines in their optical/ultraviolet spectra. This sample includes quasars spanning z ≈ 0.1–4 and probes X-ray variability on time-scales of up to ≈12 rest-frame years. Variability amplitudes are computed between every epoch of observation for each quasar and are analysed as a function of time-scale and luminosity. The tail-heavy distributions of variability amplitudes at all time-scales indicate that extreme X-ray variations are driven by an additional physical mechanism and not just typical random fluctuations of the coronal emission. Similarly, extreme X-ray variations of low-luminosity quasars seem to be driven by an additional physical mechanism, whereas high-luminosity quasars seem more consistent with random fluctuations. The amplitude at which an X-ray variability event can be considered extreme is quantified for different time-scales and luminosities. Extreme X-ray variations occur more frequently at long time-scales (Δt ≳ 300 d) than at shorter time-scales and in low-luminosity quasars compared to high-luminosity quasars over a similar time-scale. A binomial analysis indicates that extreme intrinsic X-ray variations are rare, with a maximum occurrence rate of $\lt 2.4{{\ \rm per\ cent}}$ of observations. Finally, we present X-ray variability and basic optical emission-line properties of three archival quasars that have been newly discovered to exhibit extreme X-ray variability.

Timlin, III, John D.↗

Optimization of scintillated imaging detectors for MeV X-ray radiography

Radiographic imaging at X-ray energies in the MeV range poses a complex problem. Detection of high energy X-rays depends heavily on the ability of the detection material, in this work the scintillator, to attenuate and ultimately stop the X-ray. Attenuation is more readily achieved by increasing material thickness, however thick scintillators are plagued with relatively high internal scattering, leading to an overall decrease in spatial resolution and image quality.

42 ENGINEERING↗

Speckle correlation as a monitor of X-ray free-electron laser induced crystal lattice deformation

X-ray free-electron lasers (X-FELs) present new opportunities to study ultrafast lattice dynamics in complex materials. While the unprecedented source brilliance enables high fidelity measurement of structural dynamics, it also raises experimental challenges related to the understanding and control of beam-induced irreversible structural changes in samples that can ultimately impact the interpretation of experimental results. This is also important for designing reliable high performance X-ray optical components. In this work, X-FEL beam-induced lattice alterations are investigated by measuring the shot-to-shot evolution of near-Bragg coherent scattering from a single crystalline germanium sample. It is shown that X-ray photon correlation analysis of sequential speckle patterns measurements can be used to monitor the nature and extent of lattice rearrangements. Additionally, abrupt, irreversible changes are observed following intermittent high-fluence monochromatic X-ray pulses, thus revealing the existence of a threshold response to X-FEL pulse intensity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlative analysis of structure and chemistry of Li x FePO 4 platelets using 4D-STEM and X-ray ptychography

Lithium iron phosphate (Li x FePO 4 ), a cathode material used in rechargeable Li-ion batteries, phase separates upon de/lithiation under equilibrium. The interfacial structure and chemistry within these cathode materials affects Li-ion transport, and therefore battery performance. Here, correlative imaging of Li x FePO 4 was performed using four-dimensional scanning transmission electron microscopy (4D-STEM), scanning transmission X-ray microscopy (STXM), and X-ray ptychography in order to analyze the local structure and chemistry of the same particle set. Over 50,000 diffraction patterns from 10 particles provided measurements of both structure and chemistry at a nanoscale spatial resolution (16.6–49.5 nm) over wide (several micron) fields-of-view with statistical robustness. Li x FePO 4 particles at varying stages of delithiation were measured to examine the evolution of structure and chemistry as a function of delithiation. In lithiated and delithiated particles, local variations were observed in the degree of lithiation even while local lattice structures remained comparatively constant, and calculation of linear coefficients of chemical expansion suggest pinning of the lattice structures in these populations. Partially delithiated particles displayed broadly core–shell-like structures, however, with highly variable behavior both locally and per individual particle that exhibited distinctive intermediate regions at the interface between phases, and pockets within the lithiated core that correspond to FePO 4 in structure and chemistry. The results provide insight into the Li x FePO 4 system, subtleties in the scope and applicability of Vegard’s law (linear lattice parameter-composition behavior) under local versus global measurements, and demonstrate a powerful new combination of experimental and analytical modalities for bridging the crucial gap between local and statistical characterization.

25 ENERGY STORAGE↗

Cascaded hard X-ray self-seeded free-electron laser at megahertz repetition rate

High-resolution X-ray spectroscopy in the sub-nanosecond to femtosecond time range requires ultrashort X-ray pulses and a spectral X-ray flux considerably larger than that presently available. X-ray free-electron laser (XFEL) radiation from hard X-ray self-seeding (HXRSS) setups has been demonstrated in the past and offers the necessary peak flux properties. So far, these systems could not provide high repetition rates enabling a high average flux. We report the results for a cascaded HXRSS system installed at the European XFEL, currently the only operating high-repetition-rate hard X-ray XFEL facility worldwide. A high repetition rate, combined with HXRSS, allows the generation of millijoule-level pulses in the photon energy range of 6–14 keV with a bandwidth of around 1 eV (corresponding to about 1 mJ eV –1 peak spectral density) at the rate of ten trains per second, each train including hundreds of pulses arriving at a megahertz repetition rate. At 2.25 MHz repetition rate and photon energies in the 6–7 keV range, we observed and characterized the heat-load effects on the HXRSS crystals, substantially altering the spectra of subsequent X-ray pulses. We demonstrated that our cascaded self-seeding scheme reduces this detrimental effect to below the detection level. This opens up exciting new possibilities in a wide range of scientific fields employing ultrafast X-ray spectroscopy, scattering and imaging techniques.

47 OTHER INSTRUMENTATION↗

Proton distribution visualization in perovskite nickelate devices utilizing nanofocused x rays

We use a 30-nm x-ray beam to study the spatially resolved properties of a SmNiO 3 -based nanodevice that is doped with protons. The x-ray absorption spectra supported by density-functional theory simulations show partial reduction of nickel valence in the region with high proton concentration, which leads to the insulating behavior. Concurrently, x-ray diffraction reveals only a small lattice distortion in the doped regions. Together, our results directly show that the knob which proton doping modifies is the electronic valency and not the crystal lattice. Overall, the studies are relevant to ongoing efforts to disentangle structural and electronic effects across metal-insulator phase transitions in correlated oxides.

36 MATERIALS SCIENCE↗

Computational approaches to model X-ray photon correlation spectroscopy from molecular dynamics

X-ray photon correlation spectroscopy (XPCS) allows for the resolution of dynamic processes within a material across a wide range of length and time scales. X-ray speckle visibility spectroscopy (XSVS) is a related method that uses a single diffraction pattern to probe ultrafast dynamics. Interpretation of the XPCS and XSVS data in terms of underlying physical processes is necessary to establish the connection between the macroscopic responses and the microstructural dynamics. To aid the interpretation of the XPCS and XSVS data, we present a computational framework to model these experiments by computing the X-ray scattering intensity directly from the atomic positions obtained from molecular dynamics simulations. We compare the efficiency and accuracy of two alternative computational methods: the direct method computing the intensity at each diffraction vector separately, and a method based on fast Fourier transform that computes the intensities at all diffraction vectors at once. Furthermore, the computed X-ray speckle patterns capture the density fluctuations over a range of length and time scales and are shown to reproduce the known properties and relations of experimental XPCS and XSVS for liquids.

36 MATERIALS SCIENCE↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗