Search NASA⌕ Search

SEARCH · Search NASA

Results for “absolute”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Concentration independent absolute intensity determinations A new method

Attention is given to the means for obtaining, independently of any data on molecular concentration, the absolute intensity determinations on the basis of relative line intensity measurements conducted across the vibration-rotation band of a diatomic molecule. This approach is important for the vibrational fundamental bands of diatomic molecules, which cannot be studied by the lifetime method; its application will be especially significant in the case of diatomic radical species whose concentrations can only be indirectly inferred.

Chackerian, C., Jr.↗

Variations in in-flight absolute radiometric calibration

Variations in the in-flight absolute radiometric calibration of the Coastal Zone Color Scanner and the Thematic Mapper (TM) are reviewed. At short wavelengths, the sensors show a gradual reduction in response, while in the mid-IR the TM shows oscillatory variations. One set of measurements made at White Sands, New Mexico shows anomalous results in TM bands 2 and 4. The results of a reflectance-based and a radiance-based calibration method at White Sands are described. An analysis of the radiance-based method shows the value of such measurements from helicopter altitudes for calibration.

Slater, Philip N.↗

Estimation of absolute water surface temperature based on atmospherically corrected thermal infrared multispectral scanner digital data

Airborne remote sensing systems, as well as those on board Earth orbiting satellites, sample electromagnetic energy in discrete wavelength regions and convert the total energy sampled into data suitable for processing by digital computers. In general, however, the total amount of energy reaching a sensor system located at some distance from the target is composed not only of target related energy, but, in addition, contains a contribution originating from the atmosphere itself. Thus, some method must be devised for removing or at least minimizing the effects of the atmosphere. The LOWTRAN-6 Program was designed to estimate atmospheric transmittance and radiance for a given atmospheric path at moderate spectral resolution over an operational wavelength region from 0.25 to 28.5 microns. In order to compute the Thermal Infrared Multispectral Scanner (TIMS) digital values which were recorded in the absence of the atmosphere, the parameters derived from LOWTRAN-6 are used in a correction equation. The TIMS data were collected at 1:00 a.m. local time on November 21, 1983, over a recirculating cooling pond for a power plant in southeastern Mississippi. The TIMS data were analyzed before and after atmospheric corrections were applied using a band ratioing model to compute the absolute surface temperature of various points on the power plant cooling pond. The summarized results clearly demonstrate the desirability of applying atmospheric corrections.

Anderson, James E.↗

Transport of absolute angular momentum in quasi-axisymmetric equatorial jet streams

It is well known that prograde equatorial jet stresses cannot occur in an axisymmetric inviscid fluid, owing to the constraints of local angular momentum conservation. For a viscous fluid, the constraints of mass conservation prevent the formation of any local maximum of absolute angular momentum (m) without a means of transferring m against its gradient (delta m) in the meridional plane. The circumstances under which m can be diffused up-gradient by normal molecular viscosity are derived, and illustrated with reference to numerical simulations of axisymmetric flows in a cylindrical annulus. Viscosity is shown to act so as to tend to expel m from the interior outwards from the rotation axis. Such an effect can produce local super-rotation even in a mechanically isolated fluid. The tendency of viscosity to result in the expulsion of m is shown to be analogous in certain respects to a vorticity-mixing hypothesis for the effects of non-axisymmetric eddies of the zonally-averaged flow. It is shown how the advective and diffusive transport of m by non-axisymmetric eddies can be represented by the Transformed Eulerian Mean meridional circulation and the Eliassen-Palm (EP) flux of Andrews and McIntyre respectively, in the zonal mean. Constraints on the form and direction of the EP flux in an advective/diffusive flow for such eddies are derived, by analogy with similar constraints on the diffusive flux of m due to viscosity.

Read, P. L.↗

Absolute flux measurements for swift atoms

While a torsion balance in vacuum can easily measure the momentum transfer from a gas beam impinging on a surface attached to the balance, this measurement depends on the accommodation coefficients of the atoms with the surface and the distribution of the recoil. A torsion balance is described for making absolute flux measurements independent of recoil effects. The torsion balance is a conventional taut suspension wire design and the Young modulus of the wire determines the relationship between the displacement and the applied torque. A compensating magnetic field is applied to maintain zero displacement and provide critical damping. The unique feature is to couple the impinging gas beam to the torsion balance via a Wood's horn, i.e., a thin wall tube with a gradual 90 deg bend. Just as light is trapped in a Wood's horn by specular reflection from the curved surfaces, the gas beam diffuses through the tube. Instead of trapping the beam, the end of the tube is open so that the atoms exit the tube at 90 deg to their original direction. Therefore, all of the forward momentum of the gas beam is transferred to the torsion balance independent of the angle of reflection from the surfaces inside the tube.

Fink, M.↗

Absolute 1* quantum yields for the ICN A state by diode laser gain versus absorption spectroscopy

Absolute I* quantum yields were measured as a function of wavelength for room temperature photodissociation of the ICN A state continuum. The temperature yields are obtained by the technique of time-resolved diode laser gain-versus-absorption spectroscopy. Quantum yields are evaluated at seven wavelengths from 248 to 284 nm. The yield at 266 nm is 66.0 +/- 2% and it falls off to 53.4 +/- 2% and 44.0 +/- 4% at 284 and 248 respectively. The latter values are significantly higher than those obtained by previous workers using infrared fluorescence. Estimates of I* quantum yields obtained from analysis of CN photofragment rotational distributions, as discussed by other workers, are in good agreement with the I* yields. The results are considered in conjunction with recent theoretical and experimental work on the CN rotational distributions and with previous I* yield results.

Hess, Wayne P.↗

The absolute radiometric calibration of the advanced very high resolution radiometer

The early results of an absolute radiometric calibration of the NOAA-9 AVHRR sensor indicate significant degradations in the response of bands 1 and 2 compared to prelaunch values. The results are currently in the process of being verified and it may be that refinements of the methodology will be in order as additional data sets are analyzed. The LANDSAT TM calibration used in this approach is known to be very precise and the Herman radiative transfer code, supplemented by the 5-S code for gaseous transmission, is reliable as well. The extent to which other steps in the analysis procedure give rise to uncertainties in the results is currently under investigation. Particular attention is being given to the geometric matching of the AVHRR and TM imagery, as well as to the spectral redistribution procedure. By taking advantage of a reasonably precise calibration of TM imagery acquired on the same day as the AVHRR data at White Sands, a promising approach to the in-orbit calibration of AVHRR sensors is being developed. Current efforts involve primarily the examination of additional test cases and the investigation of possible simplifications in the procedure through judicious use of atmospheric models.

Slater, P. N.↗

Absolute absorption cross sections of ozone in the 185- to 350-nm wavelength range

The absorption cross sections of ozone have been measured in the wavelength range 185-350 nm and in the temperature range 225-298 K. The absolute ozone concentrations were established by measuring the pressure of pure gaseous samples in the 0.08to 300-torr range, and the UV spectra were recorded under conditions where less than 1 percent of the sample decomposed. The temperature dependence is significant for wavelengths longer than about 280 nm. The absorption cross-section values around 210 nm were found to be about 10 percent larger than the previously accepted values.

Molina, L. T.↗

Absolute I(asterisk) quantum yields for the ICN A state by diode laser gain-vs-absorption spectroscopy

Absolute I(asterisk) quantum yields have been measured as a function of wavelength for room temperature photodissociation of the ICN A state continuum. The yields are obtained by the technique of time-resolved diode laser gain-vs-absorption spectroscopy. Quantum yields are evaluated at seven wavelengths from 248 to 284 nm. The yield at 266 nm is 66.0 + or - 2 percent and it falls off to 53.4 + or - 2 percent and 44.0 + or - 4 percent at 284 and 248 nm, respectively. The latter values are significantly higher than those obtained by previous workers using infrared fluorescence. Estimates of I(asterisk) quantum yields obtained from analysis of CN photofragment rotational distributions, as discussed by other workers, are in good agreement with the I(asterisk) yields reported here. The results are considered in conjunction with recent theoretical and experimental work on the CN rotational distributions and with previous I(asterisk) quantum yield results.

Hess, Wayne P.↗

Reflectance- and radiance-based methods for the in-flight absolute calibration of multispectral sensors

Variations reported in the in-flight absolute radiometric calibration of the Coastal Zone Color Scanner (CZCS) and the Thematic Mapper (TM) on Landsat 4 are reviewed. At short wavelengths these sensors exhibited a gradual reduction in response, while in the midinfrared the TM showed oscillatory variations, according to the results of TM internal calibration. The methodology and results are presented for five reflectance-based calibrations of the Landsat 5 TM at White Sands, NM, in the period July 1984 to November 1985. These show a + or - 2.8 percent standard deviation for the six solar-reflective bands. Analysis and preliminary results of a second, independent calibration method, based on radiance measurements from a helicopter at White Sands, indicate that this is potentially an accurate method for corroborating the results from the reflectance-based method.

Slater, P. N.↗

Absolute radiometric calibration of the Thematic Mapper

Calibration data for the solar reflective bands of the Landsat-5 TM obtained from five in-flight absolute radiometric calibrations from July 1984-November 1985 at White Sands, New Mexico are presented and analyzed. Ground reflectance and atmospheric data were utilized to predict the spectral radiance at the entrance pupil of the TM and the average number of digital counts in each TM band. The calibration of each of the TM solar reflective bands was calculated in terms of average digital counts/unit spectral radiance for each band. It is observed that for the 12 reflectance-based measurements the rms variation from the means as a percentage of the mean is + or - 1.9 percent; for the 11 measurements in the IR bands, it is + or - 3.4 percent; and the rms variation for all 23 measurements is + or - 2.8 percent.

Slater, P. N.↗

Lyman alpha SMM/UVSP absolute calibration and geocoronal correction

Lyman alpha observations from the Ultraviolet Spectrometer Polarimeter (UVSP) instrument of the Solar Maximum Mission (SMM) spacecraft were analyzed and provide instrumental calibration details. Specific values of the instrument quantum efficiency, Lyman alpha absolute intensity, and correction for geocoronal absorption are presented.

Fontenla, Juan M.↗

Crystalline sulfur dioxide: Crystal field splittings, absolute band intensities and complex refractive indices derived from infrared spectra

The infrared absorption spectra of thin crystalline films of sulfur dioxide at 90 K are reported in the 2700 to 450/cm region. The observed multiplicity of the spectral features in the regions of fundamentals is attributed to factor group splittings of the modes in a biaxial crystal lattice and the naturally present minor S-34, S-36, and O-18 isotopic species. Complex refractive indices determined by an iterative Kramers-Kronig analysis of the extinction data, and absolute band strengths derived from them, are also reported in this region.

Khanna, R. K.↗

Absolute oscillator strengths for 108 lines of Si I between 163 and 410 nanometers

Measurements of neutral silicon oscillator strengths (f-values) obtained by absorption and emission techniques have been combined using the numerical procedure of Cardon et al. (1979) to produce 108 f-values for the Si I lines between 163 and 410 nm. Beam-foil-lifetime measurements were employed to determine the absolute scale. The present measurements have uncertainties of about 0.07 dex (+ or - 16 percent) at the 1-sigma level of confidence. Good agreement is obtained between the results and previous data. The data also provide upper limits for the f-values of 22 other lines and information on the lifetimes for 36 levels in Si I.

Smith, Peter L.↗

Tunable diode laser measurements of absolute linestrengths in the HNO3 band near 5.8 microns

Absolute line strengths of selected lines in the nu 2 band of HNO3 have been measured using a tunable diode laser spectrometer operating in a sweep integration mode. The direct measurement technique has been employed to obtain line intensities at 296 K for 22 isolated lines in the 1720-1725/cm region. The reported line strengths have estimated uncertainties of 4 percent, a significant portion of this uncertainty arising from spectral interference from hot band transitions. From these line-strength measurements, an integrated band intensity of 1375/sq cm per atm at 296 K is inferred.

May, Randy D.↗

Absolute intensities of CO2 lines in the 3140-3410/cm spectral region

Absolute intensities for 430 transitions belonging to eleven rotation-vibration bands of (C-12)(O-16)2, (C-13)(O-16)2, and (O-16)(C-18)(O-18) in the 3140-3410/cm spectral region have been determined by analyzing spectra recorded at 0.01/cm resolution with the Fourier transform spectrometer in the McMath solar telescope complex at the National Solar Observatory on Kitt Peak. The data were recorded at room temperature and low pressures (less than 10 torr) using a natural sample of carbon dioxide. Intensities were derived using a nonlinear least-squares spectral fitting procedure, and the values obtained for each band have been analyzed to determine the vibrational band intensity and nonrigid rotor coefficients. An alternative mathematical formulation is shown in the case of bands for which the Coriolis effect is large and the Q-branch line intensities were not determinable either because they were severely blended or absent from the spectra. Comparison are made between the results obtained in this study and other published values.

Benner, D. Chris↗

The absolute radiometric calibration of the advanced very high resolution radiometer

An increasing number of remote sensing investigations require radiometrically calibrated imagery from NOAA Advanced Very High Resolution Radiation (AVHRR) sensors. Although a prelaunch calibration is done for these sensors, there is no capability for monitoring any changes in the in-flight absolute calibration for the visible and near infrared spectral channels. Hence, the possibility of using the reflectance-based method developed at White Sands for in-orbit calibration of LANDSAT Thematic Mapper (TM) and SPOT Haute Resolution Visible (HVR) data to calibrate the AVHRR sensor was investigated. Three diffrent approaches were considered: Method 1 - ground and atmospheric measurements and reference to another calibrated satellite sensor; Method 2 - ground and atmospheric measurements with no reference to another sensor; and Method 3 - no ground and atmospheric measurements but reference to another satellite sensor. The purpose is to describe an investigation on the use of Method 2 to calibrate NOAA-9 AVHRR channels 1 and 2 with the help of ground and atmospheric measurements at Rogers (dry) Lake, Edwards Air Force Base (EAFB) in the Mojave desert of California.

Slater, P. N.↗

Absolute radiometric calibration of the NOAA AVHRR sensors

Three different approaches to the absolute radiometric calibration of the two reflective channels of the NOAA AVHRR sensors are presented. The first method involves ground and atmospheric measurements and reference to another calibrated satellite sensor. The second involves ground and atmospheric measurements with no reference to another sensor, while the third method involves no ground and atmospheric measurements but reference to another sensor. NOAA-9 and NOAA-10 AVHRR data sets are presented.

Teillet, P. M.↗