Search NASA⌕ Search

SEARCH · Search NASA

Results for “analytical method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Quantum-Inspired Power System Reliability Assessment

To enable an in-depth study of power system operation and planning, the assessment of standard reliability indices is inevitable. The Monte Carlo Simulation (MCS) approach is a broadly used method in replacing the analytical methods in reliability indices assessment. The accuracy of MCS, however, highly depends on the sampling size, and hence, a complicated system with large number of components requires a large sampling size and daunting computational effort. To address this shortcoming, we, in this paper attempt to take advantage of potentials of the quantum computing (QC) for power system reliability assessment by realizing the following contributions: 1) an innovative quantum model designed for reliability assessment; 2) a quantum circuit that achieves the quadratic speed up compared to the classical MCS method; 3) an efficient quantum amplitude estimation (QAE) algorithm to accurately evaluate the reliability indices. The accuracy and efficacy of the quantum reliability method are extensively verified and demonstrated on both radial and mesh distribution systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fourier Analysis and Loss Modeling for Inductive Wireless Electric Vehicle Charging with Reduced Stray Field

With the growth of electric vehicle (EV) popularity, different charging options to increase user convenience and reduce charging times are being considered and researched. Among these, inductive wireless power transfer (WPT) systems for EVs are being designed to meet specifications such as stray field, power level, efficiency, misalignment tolerance, and ground clearance, which are all heavily influenced by the coil geometry. The proposed Fourier Analysis Method (FAM) is an analytical method to directly design coil geometries to meet stray field and power level requirements through an optimization of Fourier basis function coefficients. The outputs of the optimization are complex, planar coil geometries that meet the power level and stray field constraints with minimized loss factors. Contours of these potentials determine the coil conductor paths and loss models predict the system efficiency and performance over misalignment. The Fourier representation of the geometry is used to conveniently calculate the coupling over misalignment, external proximity effect loss, and ferrite loss. A 6.6 kW prototype WPT system with low stray field and high efficiency is built from the optimization results to validate the models and showcase the usefulness of the FAM design approach.

33 ADVANCED PROPULSION SYSTEMS↗

Experimental Design for a Sponge-Wipe Study to Relate the Recovery Efficiency and False Negative Rate to the Concentration of a Bacillus anthracis Surrogate for Six Surface Materials

Two concerns were raised by the Government Accountability Office following the 2001 building contaminations via letters containing Bacillus anthracis (BA). These included the: 1) lack of validated sampling methods, and 2) need to use statistical sampling to quantify the confidence of no contamination when all samples have negative results. Critical to addressing these concerns is quantifying the probability of correct detection (PCD) (or equivalently the false negative rate FNR = 1 - PCD). The PCD/FNR may depend on the 1) method of contaminant deposition, 2) surface concentration of the contaminant, 3) surface material being sampled, 4) sample collection method, 5) sample storage/transportation conditions, 6) sample processing method, and 7) sample analytical method. A review of the literature found 17 laboratory studies that focused on swab, wipe, or vacuum samples collected from a variety of surface materials contaminated by BA or a surrogate, and used culture methods to determine the surface contaminant concentration. These studies quantified performance of the sampling and analysis methods in terms of recovery efficiency (RE) and not PCD/FNR (which left a major gap in available information). Quantifying the PCD/FNR under a variety of conditions is a key aspect of validating sample and analysis methods, and also for calculating the confidence in characterization or clearance decisions based on a statistical sampling plan. A laboratory study was planned to partially fill the gap in PCD/FNR results. This report documents the experimental design developed by Pacific Northwest National Laboratory and Sandia National Laboratories (SNL) for a sponge-wipe method. The study will investigate the effects on key response variables from six surface materials contaminated with eight surface concentrations of a BA surrogate (Bacillus atrophaeus). The key response variables include measures of the contamination on test coupons of surface materials tested, contamination recovered from coupons by sponge-wipe samples, RE, and PCD/FNR. The experimental design involves 16 test runs, to be performed in two blocks of eight runs. Three surface materials (stainless steel, vinyl tile, and ceramic tile) were tested in the first block, while three other surface materials (plastic, painted wood paneling, and faux leather) will be tested in the second block. The eight surface concentrations of the surrogate were randomly assigned to test runs within each block. Some of the concentrations will be very low and may present challenges for deposition, sampling, and analysis. However, such tests are needed to investigate RE and PCD/FNR over the full range of concentrations of interest. In each run, there will be 10 test coupons of each of the three surface materials. A positive control sample will be generated prior to each test sample. The positive control results will be used to 1) calculate RE values for the wipe sampling and analysis method, and 2) fit RE- and PCD-concentration equations, for each of the six surface materials. Data analyses will support 1) estimating the PCD for each combination of contaminant concentration and surface material, 2) estimating the surface concentrations and their uncertainties of the contaminant for each combination of concentration and surface material, 3) estimating RE (%) and their uncertainties for each combination of contaminant concentration and surface material, 4) fitting PCD-concentration and RE-concentration equations for each of the six surface materials, 5) assessing goodness-of-fit of the equations, and 6) quantifying the uncertainty in PCD and RE predictions made with the fitted equations.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental Design for a Sponge-Wipe Study to Relate the Recovery Efficiency and False Negative Rate to the Concentration of a Bacillus anthracis Surrogate for Six Surface Materials

Two concerns were raised by the Government Accountability Office following the 2001 building contaminations via letters containing Bacillus anthracis (BA). These included the: 1) lack of validated sampling methods, and 2) need to use statistical sampling to quantify the confidence of no contamination when all samples have negative results. Critical to addressing these concerns is quantifying the false negative rate (FNR). The FNR may depend on the 1) method of contaminant deposition, 2) surface concentration of the contaminant, 3) surface material being sampled, 4) sample collection method, 5) sample storage/transportation conditions, 6) sample processing method, and 7) sample analytical method. A review of the literature found 17 laboratory studies that focused on swab, wipe, or vacuum samples collected from a variety of surface materials contaminated by BA or a surrogate, and used culture methods to determine the surface contaminant concentration. These studies quantified performance of the sampling and analysis methods in terms of recovery efficiency (RE) and not FNR (which left a major gap in available information). Quantifying the FNR under a variety of conditions is a key aspect of validating sample and analysis methods, and also for calculating the confidence in characterization or clearance decisions based on a statistical sampling plan. A laboratory study was planned to partially fill the gap in FNR results. This report documents the experimental design developed by Pacific Northwest National Laboratory and Sandia National Laboratories (SNL) for a sponge-wipe method. The testing was performed by SNL and is now completed. The study investigated the effects on key response variables from six surface materials contaminated with eight surface concentrations of a BA surrogate (Bacillus atrophaeus). The key response variables include measures of the contamination on test coupons of surface materials tested, contamination recovered from coupons by sponge-wipe samples, RE, and FNR. The experimental design involves 16 test runs, performed in two blocks of eight runs. Three surface materials (stainless steel, vinyl tile, and ceramic tile) were tested in the first block, while three other surface materials (plastic, painted wood paneling, and faux leather) were tested in the second block. The eight surface concentrations of the surrogate were randomly assigned to test runs within each block. Some of the concentrations were very low and presented challenges for deposition, sampling, and analysis. However, such tests are needed to investigate RE and FNR over the full range of concentrations of interest. In each run, there were 10 test coupons of each of the three surface materials. A positive control sample was generated at the same time as each test sample. The positive control results will be used to 1) calculate RE values for the wipe sampling and analysis method, and 2) fit RE- and FNR-concentration equations, for each of the six surface materials. Data analyses will support 1) estimating the FNR for each combination of contaminant concentration and surface material, 2) estimating the surface concentrations and their uncertainties of the contaminant for each combination of concentration and surface material, 3) estimating RE (%) and their uncertainties for each combination of contaminant concentration and surface material, 4) fitting FNR-concentration and RE-concentration equations for each of the six surface materials, 5) assessing goodness-of-fit of the equations, and 6) quantifying the uncertainty in FNR and RE predictions made with the fitted equations.

09 BIOMASS FUELS↗

Advanced Small Modular Reactor (SMR) Probabilistic Risk Assessment (PRA) Demonstration

A key area of the Advanced Small Modular Reactor (SMR) Probabilistic Risk Assessment (PRA) strategy is the development of methodologies and tools that will be used to predict the safety, security, safeguards, performance, and deployment viability of SMRs. The goal of the SMR PRA activity will be to develop quantitative methods and tools and the associated analysis framework for assessing a variety of risks. Development and implementation of SMR-focused safety assessment methods may require new analytic methods or adaptation of traditional methods to the advanced design and operational features of SMRs. We will need to move beyond the current limitations such as static, logic-based models in order to provide more integrated, scenario-based models based upon predictive modeling which are tied to causal factors. The development of SMR-specific safety models for margin determination will provide a safety case that describes potential accidents, design options (including postulated controls), and supports licensing activities by providing a technical basis for the safety envelope. This report documents the progress that was made to implement the PRA framework, specifically by way of demonstration of an advanced 3D approach to representing, quantifying and understanding flooding risks to a nuclear power plant.

97 MATHEMATICS AND COMPUTING↗

Assessment of the Loss of Vacuum on the Local Metal Temperature in the TEX Experiment Assembly

A four-part assessment using analytical methods and semi-analytical simulation tools finds that the maximum temperature variation in the highly enriched uranium (HEU) Jemima plate assembly is less than ten Kelvin (< 10 K) in an abrupt loss of vacuum scenario. The temperature variation in the metals is likely to be one to four Kelvin (1 K – 4 K) based on the most realistic conditions in the assessment. The four assessment parts include: (1) the peak gas temperature bound for the initial influx of the ambient air; (2) the high-heat transfer limit during the high-speed forced convection period in an insulated HEU plate; (3) the high-heat transfer limit during the high-speed forced convection period with aluminum spacers; and (4) the longer-time thermal equilibration period between the air and metal stack. The four-part assessment serves as conservative upper bound on the temperature variation in the metal stack and remains well below the 40 Kelvin limit where the temperature-induced stresses could lead to permanent, plastic deformation.

42 ENGINEERING↗

A correlation method to predict the surface pressure distribution of an infinite plate or a body of revolution from which a jet is issuing

A correlation method to predict pressures induced on an infinite plate by a jet exhausting normal to the plate into a subsonic free stream was extended to jets exhausting at angles to the plate and to jets exhausting normal to the surface of a body revolution. The complete method consisted of an analytical method which models the blockage and entrainment properties of the jet and an empirical correlation which accounts for viscous effects. For the flat plate case, the method was applicable to jet velocity ratios up to ten, jet inclination angles up to 45 deg from the normal, and radial distances up to five diameters from the jet. For the body of revolution case, the method was applicable to a body at zero degrees angle of attack, jet velocity ratios 1.96 and 3.43, circumferential angles around the body up to 25 deg from the jet, axial distances up to seven diameters from the jet, and jet-to-body diameter ratios less than 0.1.

Perkins, S. C., Jr.↗

A correlation method to predict the surface pressure distribution on an infinite plate from which a jet is issuing

A correlation method to predict pressures induced on an infinite plate by a jet issuing from the plate into a subsonic free stream was developed. The complete method consists of an analytical method which models the blockage and entrainment properties of the jet and a correlation which accounts for the effects of separation. The method was developed for jet velocity ratios up to ten and for radial distances up to five diameters from the jet. Correlation curves and data comparisons are presented for jets issuing normally from a flat plate with velocity ratios one to twelve. Also, a list of references which deal with jets in a crossflow is presented.

Perkins, S. C., Jr.↗

What FM can offer DFCS design

The results of aircrafts and spacecrafts flight tests are reported. It is shown that the problems of Digital Flight Control Systems (DFCS) are the problems of systems whose complexity has exceeded the reach of the intellectual tools employed. It is also shown that intuition, experience, and techniques derived from mechanical and analog systems are insufficient for complex, integrated, digital systems. Formal Methods (FM) of computer science can offer DFCS systematic techniques for the construction of trustworthy software, including: techniques for the precise specification of requirements and the development of designs; systematic approaches to the design and structuring of distributed and concurrent systems; fault tolerance algorithms; and systematic methods of testing and analytic methods of verification.

Rushby, John↗

Analytic Nonlinear Methods for Beam Optics

In recent years there have been major advances in the computation and use of high-order maps for the design, optimization and operation of beamlines. We will describe five practical examples for both linear and circular colliders. From least to most complex these examples will be: use of similarity transformations (FFTB design, SLC diagnosis); statistical maps (SSC smear and tune-shift); aberrations (SLC upgrade); resonance basis and nPB tracking (PEP-II design); and kick factorization (possibly LHC).

43 PARTICLE ACCELERATORS↗

Evaluation of Wilks’ One-sided Non-parametric Formula Against Analytical Parametric Methods

This paper will be presented to the "Sensitivity and Uncertainty Methods" subgroup of the "Mathematics and Computation Division" of the ANS Winter Symposium. Direct comparisons are made via simulation between the Wilks' non-parametric and Gaussian (parametric) methods which are applied in the SASQUATCH and SINDA-SAMPLE thermal-hydraulic codes, respectively, for the Advanced Test Reactor safety basis. The level of relative conservatism is quantified for the Wilks method and shown to be greater than the parametric method for an equivalent probability and confidence level.

95/95↗

Metal artifact correction for x-ray computed tomography using kV and selective MV imaging

Purpose: The overall goal of this work is to improve the computed tomography (CT) image quality for patients with metal implants or fillings by completing the missing kilovoltage (kV) projection data with selectively acquired megavoltage (MV) data that do not suffer from photon starvation. When both of these imaging systems, which are available on current radiotherapy devices, are used, metal streak artifacts are avoided, and the soft-tissue contrast is restored, even for regions in which the kV data cannot contribute any information. Methods: Three image-reconstruction methods, including two filtered back-projection (FBP)-based analytic methods and one iterative method, for combining kV and MV projection data from the two on-board imaging systems of a radiotherapy device are presented in this work. The analytic reconstruction methods modify the MV data based on the information in the projection or image domains and then patch the data onto the kV projections for a FBP reconstruction. In the iterative reconstruction, the authors used dual-energy (DE) penalized weighted least-squares (PWLS) methods to simultaneously combine the kV/MV data and perform the reconstruction. Results: The authors compared kV/MV reconstructions to kV-only reconstructions using a dental phantom with fillings and a hip-implant numerical phantom. Simulation results indicated that dual-energy sinogram patch FBP and the modified dual-energy PWLS method can successfully suppress metal streak artifacts and restore information lost due to photon starvation in the kV projections. The root-mean-square errors of soft-tissue patterns obtained using combined kV/MV data are 10–15 Hounsfield units smaller than those of the kV-only images, and the structural similarity index measure also indicates a 5%–10% improvement in the image quality. The added dose from the MV scan is much less than the dose from the kV scan if a high efficiency MV detector is assumed. Conclusions: The authors have shown that it is possible to improve the image quality of kV CTs for patients with metal implants or fillings by completing the missing kV projection data with selectively acquired MV data that do not suffer from photon starvation. Numerical simulations demonstrated that dual-energy sinogram patch FBP and a modified kV/MV PWLS method can successfully suppress metal streak artifacts and restore information lost due to photon starvation in kV projections. Combined kV/MV images may permit the improved delineation of structures of interest in CT images for patients with metal implants or fillings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗