Search NASA⌕ Search

SEARCH · Search NASA

Results for “anode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Anode phenomena in high-current accelerators

Quasi-steady MPD accelerators current conduction and power loss mechanism investigation through local anode fall voltage and current density measurements at different arc current levels

Jahn, R. G.↗

Electrochemical behavior of the boron anode in aqueous solutions

The electrochemical oxidation of p-type boron in 0.2 N NaNO3 solutions of pH 0.4 to 13.1 was studied by galvanostatic techniques. The capacitance of the electrode, Tafel slopes, and a limited analysis of reaction mechanisms are reported. The anodic dissolution in acid solution is a charge-transfer-limited one-electron reaction to form a monovalent species in the over-potential region of 0.25 to 0.70 V. The dissolution in basic solution is most probably a one-electron charge-transfer reaction from a monovalent to divalent species involving three hydroxyl ions. Open circuit potentials were mixed potentials, probably due to hydrogen formation at open circuit but not contributing to the electrochemical reaction at the applied overpotential. Exchange current, estimated by extrapolation of the Tafel line to the standard oxidation potential for the boron reaction, were of the order of 10 to the minus 6th power A/cm2 in acid solution and 10 to the minus 12th power A/cm2 in basic solution. The reaction order of the rate determining acidic and basic reactions was determined with regard to (H+) and (OH-). The level of illumination had no effect on the electrochemical behavior of the electrode.

Delduca, B. S.↗

Coaxial anode for background suppression in X-ray proportional counters

A scheme which permits the ends (near the anode seals) as well as the bottom and sides of an X-ray astronomy proportional counter to be protected by anticoincidence guard counters is described. A rocket-borne test showed that the non-X-ray background is reduced by an additional factor of about 30 when the end guard counter feature is added.

Bunner, A. N.↗

Coaxial anode for background suppression in X-ray proportional counters.

We have devised, constructed, and tested in flight a scheme which permits the ends (near the anode seals) as well as the bottom and sides of an X-ray astronomy proportional counter to be protected by anticoincidence guard counters. A rocket-borne test has shown that the non-X-ray background is reduced by an additional factor of about 30 when the end guard counter feature is added.

Bunner, A. N.↗

The Ranicon - A resistive anode image converter

A versatile photon and charged particle imaging system is described. The Ranicon employs a microchannel electron multiplier plate to convert each detected event into a charge signal. This charge pulse is proximity-focused onto a large-area resistive anode plate equipped with pickup electrodes on its edges. Each event is located electronically by the ratios of the charges collected at the edges or by the differences of the signals' risetimes. One- or two-dimensional pictures are built up by storing events digitally (e.g., a core memory) or in analog form (e.g., a storage oscilloscope). Compact laboratory models have been constructed and tested. Operating characteristics, applications, limitations, and advantages of the Ranicon are discussed.

Lampton, M.↗

Anodization improves GaAs solar cell performance

Anodization technique produces GaAs pn-junction solar cells exhibiting improved response to high energy photons and higher open circuit voltages through reduction of reflection loss.

Hovel, H. J.↗

Multiple anode arc lamp system

A high-intensity xenon arc lamp having a plurality of separate anodes axially disposed in a symmetrical pattern which spaced a discharge gap from a common cathode is presented.

Miller, C. G.↗

Multi-anode microchannel arrays

The Multi-Anode Microchannel Arrays (MAMA's) are a family of photoelectric, photon-counting array detectors being developed for use in instruments on both ground-based and space-borne telescopes. These detectors combine high sensitivity and photometric stability with a high-resolution imaging capability. MAMA detectors can be operated in a windowless configuration at extreme-ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. Prototype MAMA detectors with up to 512 x 512 pixels are now being tested in the laboratory and telescope operation of a simple (10 x 10)-pixel visible-light detector has been initiated. The construction and modes-of-operation of the MAMA detectors are briefly described and performance data are presented.

Timothy, J. G.↗

High-resolution imaging with a two-dimensional resistive anode photon counter

A method to achieve high spatial resolution readout of individual photoelectron events using microchannel plates and a resistive anode is presented. A clamped pair of microchannel plates is used, followed by a gap and a clamped triplet of microchannel plates in cascade to achieve a high stable electron gain of 3 x 10 to the 7th. The gain allows the position determination of each photoelectron event with a very high signal-to-noise ratio. A model consisting of a windowless vacuum-ultraviolet image sensor is presented to demonstrate 500 x 500 pixel images of 50 micron FWHM over a 25-mm circular field of view. The detector offers sufficient speed, sensitivity and resolution for a variety of applications, and the mount design is compatible with planar, remotely-processed, proximity-focused photocathodes.

Firmani, C.↗

Recent progress with multi-anode microchannel array detector systems

The construction and modes of operation of Multi-Anode Microchannel Arrays (MAMA's) are briefly reviewed. The MAMA detectors, which are a family of photoelectric, photon-counting array detectors being developed specifically for use in instruments on ground-based and space-borne telescopes, combine the high sensitivity and photometric stability of a conventional channel electron multiplier with a high-resolution imaging capability. The MAMA detectors feature low applied potential (less than 3 kV), high gain (greater than 10 to the 6th electrons/pulse), an absolute event timing accuracy of 100 ns or better, a very long count lifetime (greater than 2.5 x 10 to the 11th counts/sq mm), and a power consumption of less than 30 W for a complete system

Timothy, J. G.↗

High-resolution spectroscopy with the multi-anode microchannel array detector systems

The results of a series of high-resolution spectroscopic observations undertaken with a linear (1 x 1024)-pixel visible-light Multi-Anode Microchannel Array (MAMA) detector on the Coudespectrograph of the 2.2-meter telescope at the Mauna Kea Observatory and on the vacuum spectrograph of the McMath Solar telescope at the Kitt Peak National Observatory are described. In addition, the two-dimensional MAMA detector systems with (16 x 1024)-pixel, (24 x 1024)-pixel, and (256 x 1024)-pixel formats which are now being readied for use in a series of ground-based, balloon, and sounding-rocket observing programs are briefly described.

Timothy, J. G.↗

Speckle spectroscopy; an application for the multi-anode microchannel array detector system

Plans to combine the High Angular Resolution Imager/Spectrometer on the 4-meter Mayall telescope at the Kitt Peak National Observatory and the (256 x 1024)-pixel Multi-Anode Microchannel Array detector system to produce a unique instrument for speckle spectroscopy are described. The pulse-counting detector system will provide distortion-free imaging and will time tag each spatially-resolved photon event with an accuracy of 100 ns. The Imager/Spectrometer will provide a spatial resolution of 0.07 arcsec orthogonal to the plane of dispersion and 0.18 arcsec in the plane of dispersion.

Butcher, H. R.↗

Variable anodic thermal control coating on aluminum

A variable thermal control coating (modified chromic acid anodizing) has been developed to meet the needs for the thermal control of spacecraft. This coating, with controlled variable ranges of 0.10 to 0.72 thermal emittance and 0.2 to 0.4 solar absorptance, allows the user to select any value of thermal emittance and solar absorptance within the range specified and obtain both values within + or - 0.02. Preliminary solar stability has shown less than 15 percent degradation over 2000 hours of vacuum solar exposure. The technique has been determined to be sensitive to the parameters of voltage, rate of voltage application, time, temperature, acid concentration, and material pretreatment.

Duckett, R. J.↗

Performance characteristics of multi-anode microchannel array detector systems

The multi-anode microchannel arrays (MAMAs) are state-of-the-art, pulse-counting, photoelectric array detectors designed specifically for use in space astrophysics instruments. The present paper provides a description of recent progress related to the development of ultraviolet and visible-light versions of the MAMA detectors, taking into account a comparison of the operating characteristics of these devices with those of photoconductive array detectors, such as the CCDs. Attention is given to MAMA detector system design parameters, the operating characteristics of MAMAs and CCDs, MAMA performance characteristics, and future developments.

Timothy, J. G.↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Multi-Anode Microchannel Array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 square mm are now under evaluation at visible, ultraviolet and soft x-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 square mm are under development for use in the NASA Goddard Space Flight Center's Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with CsI photocathodes can provide a high-resolution imaging capability at extreme ultraviolet (EUV) and soft x-ray wavelengths and can deliver a maximum count rate from each array in excess of 1 million counts s-1. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode-of-operation and performance characteristics of the MAMA detectors are described and the program for the development of the very-large-format detectors is outlined.

Timothy, J. G.↗

Modeling for CO poisoning of a fuel cell anode

Poisoning losses in a half-cell in the 110-190 C temperature range have been measured in 100 wt pct H3PO4 for various mixtures of H2, CO, and CO2 gases in order to investigate the polarization loss due to poisoning by CO of a porous fuel cell Pt anode. At a fixed current density, the poisoning loss was found to vary linearly with ln of the CO/H2 concentration ratio, although deviations from linearity were noted at lower temperatures and higher current densities for high CO/H2 concentration ratios. The surface coverages of CO were also found to vary linearly with ln of the CO/H2 concentration ratio. A general adsorption relationship is derived. Standard free energies for CO adsorption were found to vary from -14.5 to -12.1 kcal/mol in the 130-190 C temperature range. The standard entropy for CO adsorption was found to be -39 cal/mol per deg K.

Dhar, H. P.↗