Search NASA⌕ Search

SEARCH · Search NASA

Results for “antenna arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Multicube retroreflector and retroreflector-based communication system

A “multicube” retroreflector may include “nested” corner cubes. Such a design combines the ease of fabrication of conventional corner cubes (e.g., stamping from a sheet) and the ability to easily and densely package them with a greater range of angles over which light will be reflected back towards the source. Such multicube retroreflectors may reflect 50% more light than corner cube retroreflectors. A retroreflector, or an array of retroreflectors, may be used as part of a communication system. A modulated retroreflector or an array thereof can form the basis of a unique communication system. For instance, by using a modulated retroreflector, or an array of such retroreflectors, a host system (e.g., an aircraft) can receive data from a remote system (e.g., a drone, an air-dropped sensor package, etc.) in a way that is difficult to intercept, and minimizes the power, computation, and antenna pointing requirements for the remote system.

42 ENGINEERING↗

Commissioning of the ITER-like ICRF antenna for JET

The new JET ion cyclotron resonance frequency (ICRF) ITER-like antenna (ILA), which was assembled during 2006, was commissioned on the JET RF testbed prior to installation on the JET torus. The 4 resonant double loops (RDL) of the ILA were tested at high power at 42 MHz up to 42 kV for 5 s in 10 min intervals. Low power matching studies using a saltwater load placed in front of the ILA have allowed testing and optimizing proposed matching algorithms on single RDLs, paired RDLs and finally on the full array. The upper limit of the frequency range of the ILA appears to be limited to 47 49 MHz due to the effect on the electrical lengths of the connection between the capacitors and the conjugate T point. Capacitor position scans have allowed obtaining the necessary data to confirm the RF model of the RDL which is necessary for the scattering matrix arc detection. The latter is deemed necessary in order to detect arcs at the low impedance conjugate T of the circuit. The antenna was installed onto JET during August 2007 and commissioning on plasma started May 2008. At present the commissioning of the ILA on JET is ongoing in a series of dedicated experimental campaigns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A TECHNIQUE FOR PRIMARY BEAM CALIBRATION OF DRIFT-SCANNING, WIDE-FIELD ANTENNA ELEMENTS

We present a new technique for calibrating the primary beam of a wide-field, drift-scanning antenna element. Drift-scan observing is not compatible with standard beam calibration routines, and the situation is further complicated by difficult-to-parameterize beam shapes and, at low frequencies, the sparsity of accurate source spectra to use as calibrators. We overcome these challenges by building up an interrelated network of source 'crossing points'-locations where the primary beam is sampled by multiple sources. Using the single assumption that a beam has 180 Degree-Sign rotational symmetry, we can achieve significant beam coverage with only a few tens of sources. The resulting network of crossing points allows us to solve for both a beam model and source flux densities referenced to a single calibrator source, circumventing the need for a large sample of well-characterized calibrators. We illustrate the method with actual and simulated observations from the Precision Array for Probing the Epoch of Reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Yagi–Uda nano-antenna element shape on the directivity and radiation efficiency

In this paper, different optimal designs of Yagi–Uda nano-antennas (NAs) are introduced and analyzed based on different element shapes to maximize the directivity and radiation efficiency. The studied element shapes include triangular, hexagonal, cube, square, rotated square, rectangular, ellipsoid, and elliptical cylinder shapes. The NAs parameters for each design are optimized using particle swarm optimization algorithm to achieve high directivity at a wavelength of 500 nm for wireless point-to-point applications. The designs are numerically analysed using 3-D finite difference time domain method (3-D FDTD) via Lumerical software package. To illustrate the performance of the proposed antennas, different radiation parameters such as radiation pattern, directivity, and radiation efficiency have been studied. Moreover, a tolerance of ± 5% is calculated to consider the imperfections that may appear in the fabrication process at a nanoscale. The optimized rectangular prism NA achieves the highest directivity of 24.21 with an efficiency of 50.74%. However, the optimized triangular prism NA has the highest efficiency of 73% with a directivity of 20.89. This enhancement is mainly attributed to the efficient coupling between array elements along with low side lobe level. However, a trade-off between directivity and radiation efficiency is obtained by the hexagonal prism NA with directivity of 21.9 and radiation efficiency of 69.1%.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multiresponsive polymeric microstructures with encoded predetermined and self-regulated deformability

Dynamic functions of biological organisms often rely on arrays of actively deformable microstructures undergoing a nearly unlimited repertoire of predetermined and self-regulated reconfigurations and motions, most of which are difficult or not yet possible to achieve in synthetic systems. Here, we introduce stimuli-responsive microstructures based on liquid-crystalline elastomers (LCEs) that display a broad range of hierarchical, even mechanically unfavored deformation behaviors. By polymerizing molded prepolymer in patterned magnetic fields, we encode any desired uniform mesogen orientation into the resulting LCE microstructures, which is then read out upon heating above the nematic–isotropic transition temperature (T N–I ) as a specific prescribed deformation, such as twisting, in- and out-of-plane tilting, stretching, or contraction. By further introducing light-responsive moieties, we demonstrate unique multifunctionality of the LCEs capable of three actuation modes: self-regulated bending toward the light source at T < T N–I , magnetic-field–encoded predetermined deformation at T > T N–I , and direction-dependent self-regulated motion toward the light at T > T N–I . We develop approaches to create patterned arrays of microstructures with encoded multiple area-specific deformation modes and show their functions in responsive release of cargo, image concealment, and light-controlled reflectivity. We foresee that this platform can be widely applied in switchable adhesion, information encryption, autonomous antennae, energy harvesting, soft robotics, and smart buildings.

59 BASIC BIOLOGICAL SCIENCES↗

Apparatuses and method for converting electromagnetic radiation to direct current

An energy conversion device may include a first antenna and a second antenna configured to generate an AC current responsive to incident radiation, at least one stripline, and a rectifier coupled with the at least one stripline along a length of the at least one stripline. An energy conversion device may also include an array of nanoantennas configured to generate an AC current in response to receiving incident radiation. Each nanoantenna of the array includes a pair of resonant elements, and a shared rectifier operably coupled to the pair of resonant elements, the shared rectifier configured to convert the AC current to a DC current. The energy conversion device may further include a bus structure operably coupled with the array of nanoantennas and configured to receive the DC current from the array of nanoantennas and transmit the DC current away from the array of nanoantennas.

30 DIRECT ENERGY CONVERSION↗

Local constraints on cosmic string loops from photometry and pulsar timing

We constrain the cosmological density of cosmic string loops using two observational signatures--gravitational microlensing and the Kaiser-Stebbins effect. Photometry from RXTE and CoRoT space missions and pulsar timing from Parkes Pulsar Timing Array, Arecibo and Green Bank radio telescopes allow us to probe cosmic strings in a wide range of tensions G{mu}/c{sup 2}=10{sup -16} divide 10{sup -10}. We find that pulsar timing data provide the most stringent constraints on the abundance of light strings at the level {Omega}{sub s{approx}}10{sup -3}. Future observational facilities such as the Square Kilometer Array will allow one to improve these constraints by orders of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New plasma measurements with a multichannel millimeter-wave fluctuation diagnostic system in the DIII-D tokamak (invited)

A novel multichannel, tunable Doppler backscattering (DBS)/reflectometry system has recently been developed and applied to a variety of DIII-D plasmas. Either DBS or reflectometry can be easily configured for use in a wide range of plasma conditions using a flexible quasi-optical antenna system. The multiple closely spaced channels, when combined with other fluctuation diagnostic systems, have opened up new measurements of plasma properties. For example, the toroidal and fine-scale radial structure of coherent plasma oscillations, such as geodesic acoustic modes, have been probed simultaneously in the core of high temperature plasmas by applying correlation analysis between two toroidally separated DBS systems, as well as within the multichannel array. When configured as a reflectometer, cross-correlation with electron cyclotron emission radiometry has uncovered detailed information regarding the crossphase relationship between density and temperature fluctuations. The density-temperature crossphase measurement yields insight into the physics of tokamak turbulence at a fundamental level that can be directly compared with predictions from nonlinear gyrokinetic simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Topological nanophotonics for photoluminescence control

Rare-earth-doped nanocrystals are emerging light sources that can produce tunable emissions in colours and lifetimes, which has been typically achieved in chemistry and material science. However, one important optical challenge – polarization of photoluminescence – remains largely out of control by chemistry methods. Control over photoluminescence polarization can be gained via coupling of emitters to resonant nanostructures such as optical antennas and metasurfaces. However, the resulting polarization is typically sensitive to position disorder of emitters, which is difficult to mitigate. Recently, new classes of disorder-immune optical systems have been explored within the framework of topological photonics. Here we explore disorder-robust topological arrays of Mie-resonant nanoparticles for polarization control of photoluminescence of nanocrystals. We demonstrate polarized emission from rare-earth-doped nanocrystals governed by photonic topological edge states supported by zigzag arrays of dielectric resonators. We verify the topological origin of polarized photoluminescence by comparing emission from nanoparticles coupled to topologically trivial and nontrivial arrays of nanoresonators. We expect that our results may open a new direction in the study of topology-enable emission properties of topological edge states in many photonic systems.

36 MATERIALS SCIENCE↗

Carbon nanotube biconvex microcavities

Developing highly efficient microcavities with predictive narrow-band resonance frequencies using the least amount of material will allow the applications in nonlinear photonic devices. We have developed a microcavity array that comprised multi-walled carbon nanotubes (MWCNT) organized in a biconvex pattern. The finite element model allowed designing microcavity arrays with predictive transmission properties and assessing the effects of the microarray geometry. The microcavity array demonstrated negative index and produced high Q factors. 2–3 μm tall MWCNTs were patterned as biconvex microcavities, which were separated by 10 μm in an array. The microcavity was iridescent and had optical control over the diffracted elliptical patterns with a far-field pattern, whose properties were predicted by the model. It is anticipated that the MWCNT biconvex microcavities will have implications for the development of highly efficient lenses, metamaterial antennas, and photonic circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Limits on Polarized Leakage for the PAPER Epoch of Reionization Measurements at 126 and 164 MHz

Polarized foreground emission is a potential contaminant of attempts to measure the fluctuation power spectrum of highly redshifted 21 cm H i emission from the epoch of reionization. Using the Donald C. Backer Precision Array for Probing the Epoch of Reionization, we present limits on the observed power spectra of all four Stokes parameters in two frequency bands, centered at 126 MHz (z = 10.3) and 164 MHz (z = 7.66), for a three-month observing campaign of a deployment involving 32 antennas, for which results on the unpolarized power spectrum have been reported at z = 7.7 (by Parsons et al.) and at 7.5<z<10.5 (by Jacobs et al.). The power spectra in this paper are processed in the same way as by those authors, and show no definitive detection of polarized power. This nondetection is consistent with what is known about polarized sources, combined with the suppression of polarized power by fluctuations in the ionospheric rotation measure, which can strongly affect Stokes Q and U. We are able to show that the net effect of polarized leakage is a negligible contribution at the levels of the limits reported by Parsons et al. and Jacobs et al.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of full-wave simulations for mode conversion of waves in the ion cyclotron range of frequencies with phase contrast imaging in Alcator C-Mod

Mode conversion of fast waves in the ion cyclotron range of frequencies (ICRF) is known to result in current drive and flow drive under optimised conditions, which may be utilized to control plasma profiles and improve fusion plasma performance. To describe these processes accurately in a realistic toroidal geometry, numerical simulations are essential. Quantitative comparison of these simulations and the actual experimental measurements is important to validate their predictions and to evaluate their limitations. The phase contrast imaging (PCI) diagnostic has been used to directly detect the ICRF waves in the Alcator C-Mod tokamak. The measurements have been compared with full-wave simulations through a synthetic diagnostic technique. Recently, the frequency response of the PCI detector array on Alcator C-Mod was recalibrated, which greatly improved the comparison between the measurements and the simulations. In this study, mode converted waves for D-{sup 3}He and D-H plasmas with various ion species compositions were re-analyzed with the new calibration. For the minority heating cases, self-consistent electric fields and a minority ion distribution function were simulated by iterating a full-wave code and a Fokker-Planck code. The simulated mode converted wave intensity was in quite reasonable agreement with the measurements close to the antenna, but discrepancies remain for comparison at larger distances.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Passive Heterodyne Detection Using Multiple Spatial Modes

We investigated the utility of passive heterodyne detection for the remote sensing of chemicals. We performed sensor simulations for a heterodyne receiver that operates with multiple spatial modes of radiation. We find that the heterodyne signals associated with distinct spatial modes of radiation can be detected in combination. We compare this to the well-known concept referred to as the “Siegman antenna theorem”, which is usually interpreted as limiting heterodyne receivers to a single spatial mode. We show that the heterodyne signal/noise ratio does not improve beyond the single-mode SNR. We discuss the possibility of performing imaging in the multi-mode configuration, using a multi-mirror array or an array heterodyne detector. We conclude that multiple-mode passive heterodyne sensing requires a bright source of radiation, since the combination of the modes does not boost the SNR. We discuss why passive heterodyne imaging is potentially feasible.

42 ENGINEERING↗

Design of a collective scattering system for small scale turbulence study in Korea Superconducting Tokamak Advanced Research

The design characteristics of a multi-channel collective (or coherent) scattering system for small scale turbulence study in Korea Superconducting Tokamak Advanced Research (KSTAR), which is planned to be installed in 2017, are given in this paper. A few critical issues are discussed in depth such as the Faraday and Cotton-Mouton effects on the beam polarization, radial spatial resolution, probe beam frequency, polarization, and power. A proper and feasible optics with the 300 GHz probe beam, which was designed based on these issues, provides a simultaneous measurement of electron density fluctuations at four discrete poloidal wavenumbers up to 24 cm{sup −1}. The upper limit corresponds to the normalized wavenumber k{sub θ}ρ{sub e} of ∼0.15 in nominal KSTAR plasmas. To detect the scattered beam power and extract phase information, a quadrature detection system consisting of four-channel antenna/detector array and electronics will be employed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DETECTION OF SIGNALS FROM COSMIC REIONIZATION USING RADIO INTERFEROMETRIC SIGNAL PROCESSING

Observations of the H I 21 cm transition line promises to be an important probe into the cosmic dark ages and epoch of reionization. One of the challenges for the detection of this signal is the accuracy of the foreground source removal. This paper investigates the extragalactic point source contamination and how accurately the bright sources (approx>1 Jy) should be removed in order to reach the desired rms noise and be able to detect the 21 cm transition line. Here, we consider position and flux errors in the global sky model for these bright sources as well as the frequency independent residual calibration errors. The synthesized beam is the only frequency dependent term included here. This work determines the level of accuracy for the calibration and source removal schemes and puts forward constraints for the design of the cosmic reionization data reduction scheme for the upcoming low frequency arrays such as, Murchison Widefield Array, Precision Array to Probe Epoch of Reionization, etc. We show that in order to detect the reionization signal the bright sources need to be removed from the data sets with a positional accuracy of approx0.1 arcsec. Our results also demonstrate that the efficient foreground source removal strategies can only tolerate a frequency independent antenna based mean residual calibration error of approx<0.2% in amplitude or approx<0.{sup 0}2 in phase, if they are constant over each days of observations (6 hr). In future papers, we will extend this analysis to the power-spectral domain and also include the frequency-dependent calibration errors and direction-dependent errors (ionosphere, primary beam, etc.).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commercially Fabricated Low Loss Superconducting Resonators Integrated With Detectors for Frequency Domain Multiplexing Readout of Future Cosmic Microwave Background Experiments

Planned Stage-IV cosmic microwave background (CMB) experiments call for telescopes with the order of 500 000 transition edge sensor (TES) bolometers. Such large arrays would benefit from detector multiplexing, as well as miniaturization and integration of readout components. Additionally, fabrication of micro-fabricated devices at a commercial foundry could potentially boost production rate and reduce overall cost. To this end, HYPRES, Inc., LBNL, and U.C. Berkeley are developing low loss, superconducting LC resonators integrated with antenna coupled TES bolometers for frequency multiplexing readout. The resonators are fabricated on the same wafer and are in the same process flow as the TES detectors, reducing size, weight, and wiring complexity of a detector module compared to the conventional design, where each component is fabricated separately. We have fabricated and tested resonators from 0.6 to 70 MHz, both as standalone devices and integrated with TES bolometers, all fabricated on 150- mm wafers. Finally, we discuss the design and fabrication of these devices and present measurements of the standalone resonators.

47 OTHER INSTRUMENTATION↗

Plastic Laminate Antireflective Coatings for Millimeter-Wave Optics in BICEP Array

The BICEP/Keck series of experiments target the cosmic microwave background at degree-scale resolution from the South Pole. Over the next few years, the “Stage-3” BICEP Array (BA) telescope will improve the program’s frequency coverage and sensitivity to primordial B-mode polarization by an order of magnitude. The first receiver in the array, BA1, began observing at 30/40 GHz in early 2020. The next two receivers, BA2 and BA3, are currently being assembled and will map the southern sky at frequencies ranging from 95 to 150 GHz. Common to all BA receivers is a refractive, on-axis, cryogenic optical design that focuses microwave radiation onto a focal plane populated with antenna-coupled bolometers. High-performance antireflective coatings up to 760 mm in aperture are needed for each element in the optical chain, and must withstand repeated thermal cycles down to 4 K. Here, in this work, we present the design and fabrication of the 30/40 GHz anti-reflection coatings for the recently deployed BA1 receiver, with indices matched to its various polyethylene, nylon and alumina optical components. We describe an epoxy coating technique designed for alumina optics, which achieves better than 80% transmission at room temperature. For polyethylene optical elements, we present a new heat-compression approach that allows low-density polytetrafluoroethylene AR layers to reach sub-percent reflected power. We describe the planned use of these methods for the next BA cryostats, which may inform technological choices for future small-aperture telescopes of the CMB-S4 experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast Fourier transform telescope

We propose an all-digital telescope for 21 cm tomography, which combines key advantages of both single dishes and interferometers. The electric field is digitized by antennas on a rectangular grid, after which a series of fast Fourier transforms recovers simultaneous multifrequency images of up to half the sky. Thanks to Moore's law, the bandwidth up to which this is feasible has now reached about 1 GHz, and will likely continue doubling every couple of years. The main advantages over a single dish telescope are cost and orders of magnitude larger field-of-view, translating into dramatically better sensitivity for large-area surveys. The key advantages over traditional interferometers are cost (the correlator computational cost for an N-element array scales as Nlog{sub 2}N rather than N{sup 2}) and a compact synthesized beam. We argue that 21 cm tomography could be an ideal first application of a very large fast Fourier transform telescope, which would provide both massive sensitivity improvements per dollar and mitigate the off-beam point source foreground problem with its clean beam. Another potentially interesting application is cosmic microwave background polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗