Search NASA⌕ Search

SEARCH · Search NASA

Results for “application example”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Conductive Carbon Nanotube Inks for Use with Desktop Inkjet Printing Technology

Inkjet printing is a common commercial process. In addition to the familiar use in printing documents from computers, it is also used in some industrial applications. For example, wire manufacturers are required by law to print the wire type, gauge, and safety information on the exterior of each foot of manufactured wire, and this is typically done with inkjet or laser printers. The goal of this work was the creation of conductive inks that can be applied to a wire or flexible substrates via inkjet printing methods. The use of inkjet printing technology to print conductive inks has been in testing for several years. While researchers have been able to get the printing system to mechanically work, the application of conductive inks on substrates has not consistently produced adequate low resistances in the kilohm range. Conductive materials can be applied using a printer in single or multiple passes onto a substrate including textiles, polymer films, and paper. The conductive materials are composed of electrical conductors such as carbon nanotubes (including functionalized carbon nanotubes and metal-coated carbon nanotubes); graphene, a polycyclic aromatic hydrocarbon (e.g., pentacene and bisperipentacene); metal nanoparticles; inherently conductive polymers (ICP); and combinations thereof. Once the conductive materials are applied, the materials are dried and sintered to form adherent conductive materials on the substrate. For certain formulations, increased conductivity can be achieved by printing on substrates supported by low levels of magnetic field alignment. The adherent conductive materials can be used in applications such as damage detection, dust particle removal, smart coating systems, and flexible electronic circuitry. By applying alternating layers of different electrical conductors to form a layered composite material, a single homogeneous layer can be produced with improved electrical properties. It is believed that patterning alternate layers of different conductors may improve electrical pathways through alignment of the conductors and band gap optimization. One feature of this innovation is that flexible conductive traces could be accomplished with a conductive ink having a surface resistivity of less than 10 ohms/square. Another result was that a composite material comprising a mixture of carbon nanotubes and metallic nanoparticles could be applied by inkjet printing to flexible substrates, and the resulting applied material was one to two orders of magnitude more conductive than a material made by printing inks containing carbon nanotubes alone.

Roberson, Luke↗

Similarity Metrics for Closed Loop Dynamic Systems

To what extent and in what ways can two closed-loop dynamic systems be said to be "similar?" This question arises in a wide range of dynamic systems modeling and control system design applications. For example, bounds on error models are fundamental to the controller optimization with modern control design methods. Metrics such as the structured singular value are direct measures of the degree to which properties such as stability or performance are maintained in the presence of specified uncertainties or variations in the plant model. Similarly, controls-related areas such as system identification, model reduction, and experimental model validation employ measures of similarity between multiple realizations of a dynamic system. Each area has its tools and approaches, with each tool more or less suited for one application or the other. Similarity in the context of closed-loop model validation via flight test is subtly different from error measures in the typical controls oriented application. Whereas similarity in a robust control context relates to plant variation and the attendant affect on stability and performance, in this context similarity metrics are sought that assess the relevance of a dynamic system test for the purpose of validating the stability and performance of a "similar" dynamic system. Similarity in the context of system identification is much more relevant than are robust control analogies in that errors between one dynamic system (the test article) and another (the nominal "design" model) are sought for the purpose of bounding the validity of a model for control design and analysis. Yet system identification typically involves open-loop plant models which are independent of the control system (with the exception of limited developments in closed-loop system identification which is nonetheless focused on obtaining open-loop plant models from closed-loop data). Moreover the objectives of system identification are not the same as a flight test and hence system identification error metrics are not directly relevant. In applications such as launch vehicles where the open loop plant is unstable it is similarity of the closed-loop system dynamics of a flight test that are relevant.

Whorton, Mark S.↗

Failure Accommodation Tested in Magnetic Suspension Systems for Rotating Machinery

The NASA Glenn Research Center at Lewis Field and Texas A&M University are developing techniques for accommodating certain types of failures in magnetic suspension systems used in rotating machinery. In recent years, magnetic bearings have become a viable alternative to rolling element bearings for many applications. For example, industrial machinery such as machine tool spindles and turbomolecular pumps can today be bought off the shelf with magnetically supported rotating components. Nova Gas Transmission Ltd. has large gas compressors in Canada that have been running flawlessly for years on magnetic bearings. To help mature this technology and quiet concerns over the reliability of magnetic bearings, NASA researchers have been investigating ways of making the bearing system tolerant to faults. Since the potential benefits from an oil-free, actively controlled bearing system are so attractive, research that is focused on assuring system reliability and safety is justifiable. With support from the Fast Quiet Engine program, Glenn's Structural Mechanics and Dynamics Branch is working to demonstrate fault-tolerant magnetic suspension systems targeted for aerospace engine applications. The Flywheel Energy Storage Program is also helping to fund this research.

Provenza, Andy J.↗

Efficient method for approximating nonlinear dynamics: applications to uncertainty propagation and estimation

High-order Taylor series expansions can be used to model nonlinear dynamics at the cost of integrating a large set of variational equations to obtain high-order state-transition tensors (STTs). This paper presents an innovative technique for approximating the high-order STTs that reduces significantly the computational cost by retaining only the dominant secular terms. We propagate the low-order partial derivatives of Kepler’s equation, which only requires the integration of six additional equations to extend an n-th order approximation to order (n + 1). The approximation stems from the Lindstedt-Poincare procedure and exploits the stability properties of orbital motion. Since the method makes no dynamical assumptions, it can accommodate any source of orbital perturbations. We show how the approximation of the second-order STT significantly increases the accuracy of the linear method for uncertainty propagation with only a small computational overhead. Finally, we derive a high-order approximate extended Kalman filter that implements the proposed approximation of the STT and improves the performance of linear filters. Examples of application with different perturbation sources include the heliocentric orbit of an asteroid, an orbiter around Europa, and an Earth-orbiting satellite.

Park, Ryan S↗

Self-Assembled TiN-Metal Nanocomposites Integrated on Flexible Mica Substrates towards Flexible Devices

The integration of nanocomposite thin films with combined multifunctionalities on flexible substrates is desired for flexible device design and applications. For example, combined plasmonic and magnetic properties could lead to unique optical switchable magnetic devices and sensors. In this work, a multiphase TiN-Au-Ni nanocomposite system with core–shell-like Au-Ni nanopillars embedded in a TiN matrix has been demonstrated on flexible mica substrates. The three-phase nanocomposite film has been compared with its single metal nanocomposite counterparts, i.e., TiN-Au and TiN-Ni. Magnetic measurement results suggest that both TiN-Au-Ni/mica and TiN-Ni/mica present room-temperature ferromagnetic property. Tunable plasmonic property has been achieved by varying the metallic component of the nanocomposite films. The cyclic bending test was performed to verify the property reliability of the flexible nanocomposite thin films upon bending. This work opens a new path for integrating complex nitride-based nanocomposite designs on mica towards multifunctional flexible nanodevice applications.

42 ENGINEERING↗

Using Temperature Sensitive Paint Technology

New facilities and test techniques afford research aerodynamicists many opportunities to investigate complex aerodynamic phenomena. For example, NASA Langley Research Center's National Transonic Facility (NTF) can hold Mach number, Reynolds number, dynamic pressure, stagnation temperature and stagnation pressure constant during testing. This is important because the wing twist associated with model construction may mask important Reynolds number effects associated with the flight vehicle. Beyond this, the NTF's ability to vary Reynolds number allows for important research into the study of boundary layer transition. The capabilities of facilities such as the NTF coupled with test techniques such as temperature sensitive paint yield data that can be applied not only to vehicle design but also to validation of computational methods. Development of Luminescent Paint Technology for acquiring pressure and temperature measurements began in the mid-1980s. While pressure sensitive luminescent paints (PSP) were being developed to acquire data for aerodynamic performance and loads, temperature sensitive luminescent paints (TSP) have been used for a much broader range of applications. For example, TSP has been used to acquire surface temperature data to determine the heating due to rotating parts in various types of mechanical systems. It has been used to determine the heating pattern(s) on circuit boards. And, it has been used in boundary layer analysis and applied to the validation of full-scale flight performance predictions. That is, data acquired on the same model can be used to develop trends from off design to full scale flight Reynolds number, e.g. to show the progression of boundary layer transition. A discussion of issues related to successfully setting-up TSP tests and using TSP systems for boundary layer studies is included in this paper, as well as results from a variety of TSP tests. TSP images included in this paper are all grey-scale so that similar to pictures from sublimating chemical tests areas of laminar flow appear "lighter," or white, and areas of turbulent flow appear "darker."

Hamner, M. P.↗

Challenges and Opportunities in Reactive Processing and Applications of Advanced Ceramic Materials

Recently, there has been a great deal of interest in the research, development, and commercialization of innovative synthesis and processing technologies for advanced ceramics and composite materials. Reactive processing approaches have been actively considered due to their robustness, flexibility, and affordability. A wide variety of silicon carbide-based advanced ceramics and composites are currently being fabricated using the processing approaches involving reactive infiltration of liquid and gaseous species into engineered fibrous or microporous carbon performs. The microporous carbon performs have been fabricated using the temperature induced phase separation and pyrolysis of two phase organic (resin-pore former) mixtures and fiber reinforcement of carbon and ceramic particulate bodies. In addition, pyrolyzed native plant cellulose tissues also provide unique carbon templates for manufacturing of non-oxide and oxide ceramics. In spite of great interest in this technology due to their affordability and robustness, there is a lack of scientific basis for process understanding and many technical challenges still remain. The influence of perform properties and other parameters on the resulting microstructure and properties of final material is not well understood. In this presentation, mechanism of silicon-carbon reaction in various systems and the effect of perform microstructure on the mechanical properties of advanced silicon carbide based materials will be discussed. Various examples of applications of reactively processed advanced silicon carbide ceramics and composite materials will be presented.

Singh, Mrityunjay↗

Combined Creep and Fatigue Modeling

Simultaneous consideration of creep and fatigue is of paramount importance to accurately predict component life in many industrial applications. For example, growing penetration of renewable energy onto the grid is forcing many power plants to transition from base-load power generation to more complex operation modes, characterized by a combination of base-load generation and frequent start-up and shut-down cycles. The frequent start-stop of power plants is causing a significant toll in the component life due to fatigue. As such, creep alone is not adequate anymore to predict the component life. Most existing life prediction models consider creep or fatigue independently while neglect their interactions. In this presentation, we talk about some recent efforts at NETL to develop a unified modeling framework where both creep and fatigue can be considered. The creep-fatigue interaction mechanism is studied. High-throughput simulations are performed under various hold stress and hold time, and analytical expressions are fitted for the crack growth rates under creep and/or fatigue conditions demonstrating some applications of this newly developed modeling capability.

advanced alloy development↗

Performance Testing of Yardney Li-Ion Cells and Batteries in Support of Future NASA Missions

NASA requires lightweight rechargeable batteries for future missions to Mars and the outer planets that are capable of operating over a wide range of temperatures, with high specific energy and energy densities. Due to the attractive performance characteristics, Li-ion batteries have been identified as the battery chemistry of choice for a number of future applications. For example, JPL is planning to launch another unmanned rover mission to the planet Mars. This mission, referred to as the Mars Science Laboratory (MSL), will involve the use of a rover that is much larger than the previously developed Spirit and Opportunity Rovers for the 2003 Mars Exploration Rover (MER) mission, that are currently still in operation on the surface of the planet after more than five years. Part of the reason that the MER rovers have operated so successfully, far exceeding the required mission duration of 90 sols, is that they possess robust Li-ion batteries, manufactured by Yardney Technical Products, which have demonstrated excellent life characteristics. Given the excellent performance characteristics displayed, similar Li-ion batteries have been projected to successfully meet the mission requirements of the up-coming MSL mission. In addition to future missions to Mars, Li-ion technology is attractive for a number of other future NASA applications which require high specific energy, rechargeable batteries. To ascertain the viability of using Li-ion batteries for these applications, a number of performance validation tests have been performed on both Yardney cells and batteries of various sizes. These tests include mission simulation tests, charge and discharge rate characterization testing, cycle life testing under various conditions, and storage testing.

Smart, M. C.↗

Global Clear-Sky Surface Skin Temperature from Multiple Satellites Using a Single-Channel Algorithm with Angular Anisotropy Corrections

Surface skin temperature (T(sub s)) is an important parameter for characterizing the energy exchange at the ground/water-atmosphere interface. The Satellite ClOud and Radiation Property retrieval System (SatCORPS) employs a single-channel thermal-infrared (TIR) method to retrieve T(sub s) over clear-sky land and ocean surfaces from data taken by geostationary Earth orbit (GEO) and low Earth orbit (LEO) satellite imagers. GEO satellites can provide somewhat continuous estimates of T(sub s) over the diurnal cycle in non-polar regions, while polar T(sub s) retrievals from LEO imagers, such as the Advanced Very High Resolution Radiometer (AVHRR), can complement the GEO measurements. The combined global coverage of remotely sensed T(sub s), along with accompanying cloud and surface radiation parameters, produced in near-realtime and from historical satellite data, should be beneficial for both weather and climate applications. For example, near-realtime hourly T(sub s) observations can be assimilated in high-temporal-resolution numerical weather prediction models and historical observations can be used for validation or assimilation of climate models. Key drawbacks to the utility of TIR-derived T(sub s) data include the limitation to clear-sky conditions, the reliance on a particular set of analyses/reanalyses necessary for atmospheric corrections, and the dependence on viewing and illumination angles. Therefore, T(sub s) validation with established references is essential, as is proper evaluation of T(sub s) sensitivity to atmospheric correction source. This article presents improvements on the NASA Langley GEO satellite and AVHRR TIR-based T(sub s) product that is derived using a single-channel technique. The resulting clear-sky skin temperature values are validated with surface references and independent satellite products. Furthermore, an empirically adjusted theoretical model of satellite land surface temperature (LST) angular anisotropy is tested to improve satellite LST retrievals. Application of the anisotropic correction yields reduced mean bias and improved precision of GOES-13 LST relative to independent Moderate-resolution Imaging Spectroradiometer (MYD11_L2) LST and Atmospheric Radiation Measurement Program ground station measurements. It also significantly reduces inter-satellite differences between LSTs retrieved simultaneously from two different imagers. The implementation of these universal corrections into the SatCORPS product can yield significant improvement in near-global-scale, near-realtime, satellite-based LST measurements. The immediate availability and broad coverage of these skin temperature observations should prove valuable to modelers and climate researchers looking for improved forecasts and better understanding of the global climate model.

Scarino, Benjamin R.↗

Uncertainty Models for the Hybrid Parametric Variation Method of Uncertainty Quantification; Analysis

There is some level of uncertainty in every finite element model (FEM), which flows to a level of uncertainty in predicted results. The purpose of uncertainty quantification (UQ) is to provide statistical bounds on prediction accuracy based on model uncertainty. This is distinct from model updating, which attempts to modify models to improve their accuracy. UQ does not improve the accuracy of models, but accepts that the models are inherently inaccurate and attempts to quantify the impact of that inaccuracy on predicted results. Previously, an alternate method for UQ, called the Hybrid Parametric Variation (HPV) method, was applied to Space Launch System (SLS) Hurty/Craig-Bampton (HCB) components to predict system-level statistics for launch vehicle attitude control transfer functions and core stage section loads due to buffet. The HPV method combines a parametric variation of the HCB fixed-interface (FI) modal frequencies with a nonparametric variation (NPV) method that randomly varies the HCB mass and stiffness matrices as Wishart random matrix distributions using random matrix theory (RMT). Alternatively, the most common method for modeling uncertainty in the structural dynamics community is a parametric approach, which varies physical parameters in the model. However, there are several disadvantages associated with the parametric method. Determining a reduced set of parameters that have a significant impact on the system response can be time consuming, and the selected parameter probability distributions are rarely reliably known. Therefore, in practice, the parameters are surrogates for the actual errors, and the link to parameter uncertainty is unknown. Another major drawback is that the uncertainty that can be represented is limited to the form of the nominal FEM. It is the experience of the authors that based on numerous aerospace programs, almost all FEM errors are in form rather than parameter values. This hypothesis is supported by the observation of the authors that it is almost never possible to ‘tune’ a FEM to match modal test results by only modifying model parameters. Model-form uncertainty cannot be directly represented by FEM input parameters nor included in a parametric approach. However, model-form uncertainty can be modeled using RMT, where a probability distribution is developed for the matrix ensemble of interest. The major advantage of the NPV method is that it covers errors in model form. The HPV method anchors uncertainty at the HCB component level to component modal test results by matching the HCB and test modes based on mode descriptions or other methods, and then applying differing levels of frequency variation. The specific variations depend on the confidence to which a component FEM has been validated through modal testing. The NPV method is layered on the frequency variation to match modal test self-orthogonality and cross-orthogonality (XO) results. Once the component uncertainty models are identified, they are assembled, and the uncertainty is propagated to the system level using a Monte Carlo (MC) analysis approach that generates statistics for system-level predictions This provides a UQ method that can be traced to test data, which can be updated as additional data and improved correlated models become available. The purpose of this paper is to collect and present all of the theory for HPV that has been previously published in reports and papers and to present examples of its application. Specifically, component uncertainty models based on the dispersion of corresponding mass and stiffness matrices using proposed test/analysis correlation metrics are investigated. The first example is purely academic so that the true answers are known, and the validity of the HPV method and the corresponding uncertainty models can be determined. The purpose of this paper is to collect and present all of the theory for HPV that has been previously published in reports and papers and to present examples of its application. Specifically, component uncertainty models based on the dispersion of corresponding mass and stiffness matrices using proposed test/analysis correlation metrics are investigated. The first example is purely academic so that the true answers are known, and the validity of the HPV method and the corresponding uncertainty models can be determined. The second example is an application to a component that is design specific to the SLS. Based on this work and other assessments, the HPV method provides another tool to the toolset used for complex system UQ analysis. From experience gathered to date using the HPV method, additional design specific applications must be investigated to provide further confidence in the validity of the HPV method of UQ analysis.

Uncertainty quantification↗

Verification of Space Station Secondary Power System Stability Using Design of Experiment

This paper describes analytical methods used in verification of large DC power systems with applications to the International Space Station (ISS). Large DC power systems contain many switching power converters with negative resistor characteristics. The ISS power system presents numerous challenges with respect to system stability such as complex sources and undefined loads. The Space Station program has developed impedance specifications for sources and loads. The overall approach to system stability consists of specific hardware requirements coupled with extensive system analysis and testing. Testing of large complex distributed power systems is not practical due to size and complexity of the system. Computer modeling has been extensively used to develop hardware specifications as well as to identify system configurations for lab testing. The statistical method of Design of Experiments (DoE) is used as an analysis tool for verification of these large systems. DOE reduces the number of computer runs which are necessary to analyze the performance of a complex power system consisting of hundreds of DC/DC converters. DoE also provides valuable information about the effect of changes in system parameters on the performance of the system. DoE provides information about various operating scenarios and identification of the ones with potential for instability. In this paper we will describe how we have used computer modeling to analyze a large DC power system. A brief description of DoE is given. Examples using applications of DoE to analysis and verification of the ISS power system are provided.

Karimi, Kamiar J.↗

Force-Measuring Clamps

Force-measuring clamps have been invented to facilitate and simplify the task of measuring the forces or pressures applied to clamped parts. There is a critical need to measure clamping forces or pressures in some applications for example, while bonding sensors to substrates or while clamping any sensitive or delicate parts. Many manufacturers of adhesives and sensors recommend clamping at specific pressures while bonding sensors or during adhesive bonding between parts in general. In the absence of a force-measuring clamp, measurement of clamping force can be cumbersome at best because of the need for additional load sensors and load-indicating equipment. One prior method of measuring clamping force involved the use of load washers or miniature load cells in combination with external power sources and load-indicating equipment. Calibrated spring clamps have also been used. Load washers and miniature load cells constitute additional clamped parts in load paths and can add to the destabilizing effects of loading mechanisms. Spring clamps can lose calibration quickly through weakening of the springs and are limited to the maximum forces that the springs can apply. The basic principle of a force-measuring clamp can be implemented on a clamp of almost any size and can enable measurement of a force of almost any magnitude. No external equipment is needed because the component(s) for transducing the clamping force and the circuitry for supplying power, conditioning the output of the transducers, and displaying the measurement value are all housed on the clamp. In other words, a force-measuring clamp is a complete force-application and force-measurement system all in one package. The advantage of unitary packaging of such a system is that it becomes possible to apply the desired clamping force or pressure with precision and ease.

Nunnelee, Mark↗

Implementing an Applied Science Program

The work implied in the NASA Applied Science Program requires a delicate balancing act for the those doing it. At the implementation level there are multiple tensions intrinsic to the program. For example each application of an existing product to a decision support process requires deep knowledge about the data and deep knowledge about the decision making process. It is highly probable no one person has this range of knowledge. Otherwise the decision making process would already be using the data. Therefore, a team is required. But building a team usually requires time, especially across agencies. Yet the program mandates efforts of relatively short duration. Further, those who know the data are scientists, which makes them essential to the program. But scientists are evaluated on their publication record. Anything which diverts a scientist from the research for his next publication is an anathema to him and potential death to their career. Trying to get another agency to use NASA data does not strike most scientists as material inherently suitable for publication. Also, NASA wishes to rapidly implement often substantial changes to another agency's process. For many reasons, such as budget and program constraints, speed is important. But the owner of a decision making process is tightly constrained, usually by law, regulation, organization and custom. Changes when made are slow, cautious, even hesitant, and always done according a process specific to the situation. To manage this work MSFC must balance these and other tensions. Some things we have relatively little control over, such as budget. These we try to handle by structural techniques. For example by insisting all of our people work on multiple projects simultaneously we inherently have diversification of funding for all of our people. In many cases we explicitly use some elements of tension to be productive. For example the need for the scientists to constantly publish is motivation to keep tasks short and to the immediate point. As another example, the DSS agency and it personnel are treated as integral to the effort at every step. Thus, their ways of doing things, their problems and their assets become part of the solution. MSFC also manages the Applied Science work' within a strategic framework.' First, the scientists are necessarily at the core of all of this work as well as all of the work within the larger' organization. We therefore strive to keep a roughly 50-50 balance between the work done on tasks funded directly by the research side of NASA's Science Mission Directorate and funding from the applied side. Done at both the organization level and the level of the individual, this keeps the scientist both happy and productive over the long term. We also try diligently to remove as much burden from the scientist as practical by employing people such as the authors and others to do tasks not requiring; scientific knowledge. We also have designed our effort to take full use of external partners. We actively seek and support, including fund, people from multiple organizations to join us as committed collaborators. In this we use today's money and today's problem to help us diversify and strengthen for tomorrow. MSFC also considers the Applied Science work holistically. Each element is viewed as a step in a larger process. At a management level we can chose to emphasize or encourage certain areas which service long term goals. Thus, if we think work in a particular area should be developed, we can start with the smaller, less costly elements and grow.

Rickman, Doug↗

Principles, Techniques, and Applications of Tissue Microfluidics

The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called tissue microfluidics because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets. The proposed principles represent a paradigm shift in microfluidic technology in three important ways: Microfluidic devices are to be directly integrated with, onto, or around tissue samples, in contrast to the conventional method of off-chip sample extraction followed by sample insertion in microfluidic devices. Architectural and operational principles of microfluidic devices are to be subordinated to suit specific tissue structure and needs, in contrast to the conventional method of building devices according to fluidic function alone and without regard to tissue structure. Sample acquisition from tissue is to be performed on-chip and is to be integrated with the diagnostic measurement within the same device, in contrast to the conventional method of off-chip sample prep and subsequent insertion into a diagnostic device. A more advanced form of tissue integration with microfluidics is tissue encapsulation, wherein the sample is completely encapsulated within a microfluidic device, to allow for full surface access. The immediate applications of these approaches lie with diagnostics of tissue slices and biopsy samples e.g. for cancer but the approaches would also be very useful in comparative genomics and other areas of fundamental research involving heterogeneous tissue samples.

Wade, Lawrence A.↗

Distributed strain sensing using Bi-metallic coated fiber optic sensors embedded in stainless steel

Silica fiber optic sensors are resistant to corrosive environments and high temperatures, making them attractive candidates for harsh conditions found in nuclear and aerospace industries. Moreover, fibers can be deployed remotely for continuous measuring of spatially distributed temperatures and strains. Here, this study investigated embedding a Ni/Cu bi-metallic coated fiber in a stainless-steel 316 (SS316) matrix using laser powder bed fusion towards functionalizing metal components for site-specific health monitoring. The embedded fiber was continuously interrogated during controlled heating to 1000°C. The measured fiber strains were similar to the expected differential thermal strains between the fiber and the SS316 matrix, until divergent behavior was observed at temperatures >500°C. No debonding at the matrix–coating–fiber interfaces was observed during microscopy, but significant interactions between the coatings and matrix resulted in diffusion-driven chemistry variations and Kirkendall void formation. Applying the strain-lag theory revealed plastic behavior in the Ni coating at temperatures >500°C, limiting the strain transfer to the fiber at higher temperatures. It was estimated that the elastic modulus in the Ni coating had decreased from ~200 GPa at room temperature to below 40 GPa, starting at 600°C. The low elastic modulus above 600°C is within the margin of what the tangent modulus would be in the case of bilinear isotropic hardening. Regardless of the divergent strain transfer at higher temperatures, the fiber was exposed to the equivalent of 1.9 % engineering strain at 1000°C, but measured only a 0.7 % engineering strain due to the poor strain transfer. Although compensating for the plastic behavior of Ni proved challenging, the bonding of a brittle silica fiber to a metal matrix surviving to 1000°C invites potential iterations on coating material for future application. For example, the embedded fiber is sufficient for acoustic energy transfer, realizing high temperature distributed acoustic sensing.

36 MATERIALS SCIENCE↗

Evolution of storage monitoring – update in response to commercial and regulatory drivers

Carbon Capture and Storage (CCS) is in transition from first-of-a kind projects and research-orientated pilots to commercially-motivated applications. Monitoring results from many newly developed and planned large scale commercial projects are limited; however, it is worthwhile to assess their evolution and consider new strategies as part of an effort to assess and document best practices. Commercial monitoring is targeted to activities that comply with regulatory drivers and de-risk investments. Commercial monitoring also supports accounting that storage has occurred and is tied to project financing. It deals with long time frames and large volumes injected into multiple wells and multiple projects in favorable areas. We see developing trends toward reproducible workflows that systematically reduce risks and clarify expectations for oversight and long-term surveillance. Monitoring techniques showing increasing trends include injection zone pressure as a history-matching and compliance tool. To reduce cost and environmental impact of time-lapse seismic data collection, deploying new approaches and tools, such as use of fibre and installed sources are increasingly applied. Concern over the risk of induced seismicity by regulatory bodies and the general public has increased, which has also resulted in increased monitoring. Some techniques used in the early research phases have been sidelined or used only in restricted applications. For example, geochemical analyses in the injection zone as well as the environment are now being deployed less than it was in research-oriented programs, except in the US where it is required by the permitting process. Expectations of frequent area-wide near surface monitoring have also decreased.

25 ENERGY STORAGE↗