Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic scale imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Atomic dynamics of gas-dependent oxide reducibility

Understanding oxide reduction is critical for advancing metal production, catalysis and energy technologies. Although carbon monoxide (CO) and hydrogen (H 2 ) are widely used reductants, the mechanisms by which they work are often presumed to be similar, both involving lattice oxygen removal. However, because of growing interest in replacing CO with H 2 to lower CO 2 emissions, distinguishing gas-specific reduction pathways is critical. Yet, capturing these atomic-scale processes under reactive gas and high-temperature conditions remains challenging. Here we use environmental transmission electron microscopy, which is capable of real-time, atomic-resolution imaging of gas–solid redox reactions to directly visualize the gas-dependent oxide reduction dynamics in NiO. We show that CO drives surface nucleation and the growth of metallic Ni islands, leading to self-limiting surface metallization. Conversely, H 2 activates a coupled surface-to-bulk transformation, where protons from dissociated H 2 infiltrate the oxide lattice to promote the inward migration of surface-generated oxygen vacancies and enabling bulk metallization. By contrast, oxygen vacancies formed by CO remain confined near the surface, where they rapidly form a metallic Ni layer that inhibits further reduction. Furthermore, these results reveal distinct atomistic pathways for CO and H 2 and provide insights that may guide metallurgical processes and catalyst design.

36 MATERIALS SCIENCE↗

Photoionization microscopy of the lithium atom: Wave-function imaging of quasibound and continuum Stark states

Photoionization of an atom in the presence of a uniform static electric field provides the unique opportunity to expand and visualize the atomic wave function at a macroscopic scale. In a number of seminal publications dating back to the 1980s, Fabrikant, Demkov, Kondratovich, and Ostrovsky showed that this goal could be achieved by projecting slow (meV) photoionized electrons onto a position-sensitive detector and underlined the distinction between continuum and resonant contributions. Here, the uncovering of resonant signatures was achieved fairly recently in experiments on the nonhydrogenic lithium atoms [Cohen et al., Phys. Rev. Lett. 110, 183001 (2013)]. The purpose of the present article is the general description of these findings, with emphasis on the various manifestations of resonant character. From this point of view, lithium has been chosen as an illustrative example between the two limiting cases of hydrogen, where resonance effects are more easily identified, and heavy atoms like xenon, where resonant effects were not observed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Atomic-resolution defect contrast in low angle annular dark-field STEM

While traditional high-resolution STEM is performed by exclusively collecting electrons which have been scattered to high angles (i.e., HAADF), the present contribution will focus on small-angle scattered electrons, as in low angle annular dark-field (LAADF) STEM. This unique imaging mode allows one to image defect contrast while maintaining directly interpretable atomic resolution. By simply adjusting the microscope camera length, and thus the acceptance angle of the annular detector, it is possible to transition between Z-contrast and defect contrast. Both LAADF and HAADF experimental and computational results are discussed in regards to zone axis imaging of a y/y1Ni-superalloy; various length scales are explored. Electron de-channeling is observed while the probe is placed over defected regions of crystal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-Dimensional Geometry of Nanometer-Scale AlN Pits: A New Template for Quantum Dots?

The exact 3D geometry of nanometer-scale AlN pits is determined by Z-contrast imaging. The figure shows the 3D geometry of an AlN nano-pit and its corresponding GaN quantum dot. An atomic-resolution Z-contrast image is displayed in false color to clearly show the Z-contrast of the image, while the other panel displays a schematic 3D view.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Probing the Complexities of Structural Changes in Layered Oxide Cathode Materials for Li-Ion Batteries during Fast Charge–Discharge Cycling and Heating

The rechargeable lithium-ion battery (LIB) is the most promising energy storage system to power electric vehicles with high energy density and long cycling life. However, in order to meet customers’ demands for fast charging, the power performances of current LIBs need to be improved. From the cathode aspect, layer-structured cathode materials are widely used in today’s market and will continue to play important roles in the near future. The high rate capability of layered cathode materials during charging and discharging is critical to the power performance of the whole cell and the thermal stability is closely related to the safety issues. Therefore, the in-depth understanding of structural changes of layered cathode materials during high rate charging/discharging and the thermal stability during heating are essential in developing new materials and improving current materials. Since structural changes take place from the atomic level to the whole electrode level, combination of characterization techniques covering multilength scales is quite important. Finally, in many cases, this means using comprehensive tools involving diffraction, spectroscopy, and imaging to differentiate the surface from the bulk and to obtain structural/chemical information with different levels of spatial resolution.

25 ENERGY STORAGE↗

Recombination between 13 C and 2 H to Form Acetylide ( 13 C 2 2 H – ) Probes Nanoscale Interactions in Lipid Bilayers via Dynamic Secondary Ion Mass Spectrometry: Cholesterol and GM 1 Clustering

Although it is thought that there is lateral heterogeneity of lipid and protein components within biological membranes, probing this heterogeneity has proven challenging. The difficulty in such experiments is due to both the small length scale over which such heterogeneity can occur, and the significant perturbation resulting from fluorescent or spin labeling on the delicate interactions within bilayers. Atomic recombination during dynamic nanoscale secondary ion imaging mass spectrometry (NanoSIMS) is a non-perturbative method for examining nanoscale bilayer interactions. Atomic recombination is a variation on conventional NanoSIMS imaging, whereby an isotope on one molecule combines with a different isotope on another molecule during the ionization process, forming an isotopically enriched polyatomic ion in a distance-dependent manner. In this work, we show that the recombinant ion, 13 C 2 2 H – , is formed in high yield from 13 C- and 2 H-labeled lipids. The low natural abundance of triply labeled acetylide also makes it an ideal ion to probe GM 1 clusters in model membranes and the effects of cholesterol on lipid–lipid interactions. We find evidence supporting the cholesterol condensation effect as well as the presence of nanoscale GM 1 clusters in model membranes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BEACON—automated aberration correction for scanning transmission electron microscopy using Bayesian optimization

Aberration correction is an important aspect of modern high-resolution scanning transmission electron microscopy. Most methods of aligning aberration correctors require specialized sample regions and are unsuitable for fine-tuning aberrations without interrupting on-going experiments. Here, we present an automated method of correcting first- and second-order aberrations called BEACON, which uses Bayesian optimization of the normalized image variance to efficiently determine the optimal corrector settings. We demonstrate its use on gold nanoparticles and a hafnium dioxide thin film showing its versatility in nano- and atomic-scale experiments. BEACON can correct all first- and second-order aberrations simultaneously to achieve an initial alignment and first- and second-order aberrations independently for fine alignment. Ptychographic reconstructions are used to demonstrate an improvement in probe shape and a reduction in the target aberration.

techniques and instrumentation↗

A platform for quantum information and large-scale entanglement with Rydberg atoms in programmable optical potentials

Large-scale quantum systems with controllable interactions are important for understanding complex phenomena in nature, and are the basis for advanced quantum technologies. Realizing a controllable platform for controlling, understanding, and ultimately harnessing the entanglement is an outstanding challenge in quantum science. This project demonstrated reconfigurable arrays of individually-trapped ultracold atoms, thus realizing a platform that could demonstrate large-scale quantum entanglement with the addition of strong inter-atomic interactions. Arrays of more than 50 trap sites were formed via digital holography and a high-numerical aperture imaging system that featured in-situ trap diagnostics and single-atom imaging resolution. We further discovered a new implementation of a controlled-phase gate that utilized coherent excitation to Rydberg states. This method will enable robust entanglement protocols in many-atom systems such as the one developed here.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy (DOE SBIR Phase II/IIA Final Report)

Actoprobe LLC reports on the results of its DOE SBIR Phase II/IIA project on the development of Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy. While chemistry science and technology greatly benefit from Atomic Force Microscopy in surface characterization, time-resolved chemical imaging on the single-molecule level lags far behind. Current scanning probe microscopy only obtains information about mechanical but not optical/chemical properties. To address this problem, the Actoprobe LLC research team has proposed a novel class of Atomic Force Microscopy probes, Ultra-Fast Pulsed Active Atomic Force Microscopy Optical Probes (UFP AAOPs), that will allow ultrafast time-resolved optical and chemical imaging at the nanoscale. As envisioned, these unique optical probes will perform the functions of conventional Atomic Force Microscopy probes and, in addition, will simultaneously provide chemical information about molecular scale interactions. This innovation is accomplished by integrating an ultrafast pulsed Quantum Dot laser source into an Atomic Force Microscopy probe. This report describes our progress with the fabrication of an ultrafast micrometer-size semiconductor laser, based on “artificial atoms” - Quantum Dots, integrated with an Atomic Force Microscopy probe. In this Phase II/IIA project, we have demonstrated the feasibility of the UFP AAOP concept by fabricating a first prototype of the UFP AAOP. The excellent performance of the probe has been proven in terms of AFM and optical spatial resolution through rigorous tests. The UFP AAOP provides pulses with less than 4 ps duration and higher than 11 GHz repetition rate, and spatial resolution better than 300 nm at 1240 nm wavelength. Technically, it is possible to reduce the pulse width to less than 1 ps and to improve lateral resolution to ~ 0.5 nm, which implies the potential capability for the probe to characterize chemical compounds with single-molecule resolution. The UFP AAOP fabrication procedure has been developed for wafer-scale production of multiple devices, with the yield of the process estimated to be lower than 1% with the limited fabrication capabilities and equipment available for use in the research project. However, using high-volume production tools and special GaAs processing equipment, the yield can be significantly improved, theoretically to ~ 50%. Finally, economic feasibility and scale-up manufacturing potential were analyzed for UFP AAOP and found to be very promising. In summary, the Actoprobe team has successfully demonstrated the feasibility of the UFP AAOP concept.

36 MATERIALS SCIENCE↗

High-stability cryogenic scanning tunneling microscope based on a closed-cycle cryostat

We report on the design and operation of a cryogenic ultra-high vacuum (UHV) scanning tunneling microscope (STM) coupled to a closed-cycle cryostat (CCC). The STM is thermally linked to the CCC through helium exchange gas confined inside a volume enclosed by highly flexible rubber bellows. The STM is thus mechanically decoupled from the CCC, which results in a significant reduction of the mechanical noise transferred from the CCC to the STM. Noise analysis of the tunneling current shows current fluctuations up to 4% of the total current, which translates into tip-sample distance variations of up to 1.5 picometers. This noise level is sufficiently low for atomic-resolution imaging of a wide variety of surfaces. To demonstrate this, atomic-resolution images of Au(111) and NaCl(100)/Au(111) surfaces, as well as of carbon nanotubes deposited on Au(111), were obtained. Thermal drift analysis showed that under optimized conditions, the lateral stability of the STM scanner can be as low as 0.18 Å/h. Scanning Tunneling Spectroscopy measurements based on the lock-in technique were also carried out, and showed no detectable presence of noise from the closed-cycle cryostat. Using this cooling approach, temperatures as low as 16 K at the STM scanner have been achieved, with the complete cool-down of the system typically taking up to 12 h. These results demonstrate that the constructed CCC-coupled STM is a highly stable instrument capable of highly detailed spectroscopic investigations of materials and surfaces at the atomic scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bright high-repetition-rate source of narrowband extreme-ultraviolet harmonics beyond 22 eV

Novel table-top sources of extreme-ultraviolet light based on high-harmonic generation yield unique insight into the fundamental properties of molecules, nanomaterials or correlated solids, and enable advanced applications in imaging or metrology. Extending high-harmonic generation to high repetition rates portends great experimental benefits, yet efficient extreme-ultraviolet conversion of correspondingly weak driving pulses is challenging. In this article, we demonstrate a highly-efficient source of femtosecond extreme-ultraviolet pulses at 50-kHz repetition rate, utilizing the ultraviolet second-harmonic focused tightly into Kr gas. In this cascaded scheme, a photon flux beyond ≈3 × 10 13 s -1 is generated at 22.3 eV, with 5 × 10 -5 conversion efficiency that surpasses similar harmonics directly driven by the fundamental by two orders-of-magnitude. The enhancement arises from both wavelength scaling of the atomic dipole and improved spatio-temporal phase matching, confirmed by simulations. Finally, spectral isolation of a single 72-meV-wide harmonic renders this bright, 50-kHz extreme-ultraviolet source a powerful tool for ultrafast photoemission, nanoscale imaging and other applications.

36 MATERIALS SCIENCE↗

Structurally induced magnetization in a La 2/3 Sr 4/3 MnO 4 superlattice

A structural transition has been observed in a digital superlattice of La 2/3 Sr 4/3 MnO 4 , which is correlated to a magnetization enhancement upon cooling the sample. The artificial superlattices were grown layer-by-layer using ozone-assisted molecular beam epitaxy (MBE). Electron diffraction experiments show a phase transition below 150K in nanopatches of the superlattice, which coincides with an enhanced magnetization starting below 110K. Furthermore, atomic scale electron energy loss spectroscopy (EELS) shows changes in the Mn L 2,3 and O K edges, which are related to valence, strain, and the atomic coordination within nanopatches. Atomic resolution image and EELS showing variations of oxygen and lanthanum signature edges in a La 2/3 Sr 4/3 MnO 4 supperlattice.

36 MATERIALS SCIENCE↗

Scanning transmission election microscopy observations of twisted epitaxial gold nanodiscs in twisted molybdenum disulfide bilayers

Atomic scale, scanning transmission electron microscopy (STEM) analysis of the moiré structures in twisted epitaxial gold nanodiscs encapsulated in twisted bilayer molybdenum disulfide is presented. High angle annular dark field STEM imaging reveals that the period of the moiré patterns between gold and molybdenum disulfide varies with different twist angles of the bilayer molybdenum disulfide, ranging from 1.80 nm (epitaxial alignment of gold) to 1.53 nm (twisted epitaxial alignment of gold). Additionally, bright field STEM imaging reveals a faint, larger "moiré of moiré" structure in cases where the bilayer molybdenum disulfide twist angle is small (~6°), arising from the overlapping three-layers, which is not visible in conventional transmission electron microscopy images. In conclusion, our experiments indicate that scanning transmission electron microscopy as a suitable tool for moiré analysis of twisted multilayer planar heterostructures, complementary to information provided by conventional transmission electron microscopy and diffraction.

Au↗

Correlating Nanoscale Secondary Ion Mass Spectrometry and Atom Probe Tomography Analysis of Uranium Enrichment in Metallic Nuclear Fuel

Distribution and enrichment of 235U within nuclear fuels are essential to material performance and reactor safety. With the development of metallic U fuels, understanding 235U homogeneity has become increasingly important, however, it is difficult to map with high spatial, and mass resolution to analyze both matrix and secondary phase precipitates. Here, we analyze 235U enrichment in matrix and carbide phases in LEU-Mo via two chemical imaging modalities: nanoscale secondary ion mass spectrometry (nanoSIMS) and atom probe tomography (APT). NanoSIMS and APT provided consistent results, with no statistically significant difference between measured and nominal enrichment (19.75 % 235U).

U-10Mo, atom probe tomography, nanoscale secondary↗

Multiresolution persistent homology for excessively large biomolecular datasets

Although persistent homology has emerged as a promising tool for the topological simplification of complex data, it is computationally intractable for large datasets. We introduce multiresolution persistent homology to handle excessively large datasets. We match the resolution with the scale of interest so as to represent large scale datasets with appropriate resolution. We utilize flexibility-rigidity index to access the topological connectivity of the data set and define a rigidity density for the filtration analysis. By appropriately tuning the resolution of the rigidity density, we are able to focus the topological lens on the scale of interest. The proposed multiresolution topological analysis is validated by a hexagonal fractal image which has three distinct scales. We further demonstrate the proposed method for extracting topological fingerprints from DNA molecules. In particular, the topological persistence of a virus capsid with 273 780 atoms is successfully analyzed which would otherwise be inaccessible to the normal point cloud method and unreliable by using coarse-grained multiscale persistent homology. The proposed method has also been successfully applied to the protein domain classification, which is the first time that persistent homology is used for practical protein domain analysis, to our knowledge. The proposed multiresolution topological method has potential applications in arbitrary data sets, such as social networks, biological networks, and graphs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II

We report the commissioning of a multimodal computed tomography experimental setup at the 28-ID-2 (XPD) beamline of the National Synchrotron Light Source II. This high-energy (>60 keV) resource features a tunable X-ray beam size ranging from several millimetres to a few micrometres and enables comprehensive characterization of high-Z materials—an essential capability for nuclear and advanced materials research. It provides four complementary computed tomography modalities: X-ray absorption, X-ray fluorescence, X-ray diffraction, and pair distribution function tomography. A case study using a custom-made heterogeneous sample demonstrates these abilities to simultaneously capture atomic, elemental, and morphological information. This unique combination of imaging, structural, and chemical sensitive methods provides a holistic approach to study complex materials with amorphous and crystalline systems across multiple length scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct Visualization of Li Dendrite Effect on LiCoO 2 Cathode by In Situ TEM

Li dendrites are known to cause deterious, and in many cases catastrophic, effect on the performance of Li rechargeable batteries. However, the mechanistic failure mechanism of cathodes upon in contact with Li metal is far from clear. In this study, using in situ transmission electron microscopy, we directly visualize at an atomic scale the interaction of Li dendrites with well-defined, epitaxial thin films of LiCoO2, the most widely used cathode material. We show that a spontaneous and prompt chemical reaction is trigged once the Li contact is made, leading to expansion and amorphization of the LiCoO2 structure, with Li2O and Co metal being the final reaction products. A topotactic phase transition is identified close to the reaction front, resulting in the formation of CoO as a metastable intermediate. Dynamic structural and chemical imaging in combination with ab inito simulations reveal that a high density of antiphase grain boundaries are formed at the reaction front, which are critical for enabling the short-range topotactic reactions and long-range Li propagation. The fundamental insights are of general importance in mitigating Li dendrites related issues and guiding the design principle for more robust energy materials.

In situ transmission electron microscopy (TEM), Li↗

Non-spectroscopic composition measurements of SrTiO 3 -La 0.7 Sr 0.3 MnO 3 multilayers using scanning convergent beam electron diffraction

The local atomic structure of a crystalline sample aligned along a zone axis can be probed with a focused electron probe, which produces a convergent beam electron diffraction pattern. The introduction of high speed direct electron detectors has allowed for experiments that can record a full diffraction pattern image at thousands of probe positions on a sample. By incoherently summing these patterns over crystalline unit cells, we demonstrate in this paper that in addition to crystal structure and thickness, we can also estimate the local composition of a perovskite superlattice sample. This is achieved by matching the summed patterns to a library of simulated diffraction patterns. Finally, this technique allows for atomic-scale chemical measurements without requiring a spectrometer or hardware aberration correction.

74 ATOMIC AND MOLECULAR PHYSICS↗