Search NASA⌕ Search

SEARCH · Search NASA

Results for “baseline performance reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Launch Complex 34, SWMU CC054 2023 DNAPL Source Zone Operations, Maintenance, and Monitoring, Site-Wide Long-Term Monitoring, and Hot Spot 6 Air Sparge System Annual Performance Monitoring and Phase Two Expansion Construction Completion Report Cape Canaveral Space Force Station, Florida

This Annual Performance Monitoring Report (PMR) for the Dense Non-Aqueous Phase Liquid (DNAPL) Source Zone (DSZ), Site-Wide Long-Term Monitoring (LTM), and Hot Spot 6 (HS 6) Air Sparge (AS) System presents the results of Year 14 operations and performance monitoring of the hydraulic containment (HC) Interim Measure (IM), details associated with construction and implementation of the HS 6 AS system expansion (Phase Two), and the results of operations and performance sampling of the HS 6 AS IM at Launch Complex 34 (LC34), located at Cape Canaveral Space Force Station (CCSFS), Florida. The timeframe for activities documented in this PMR extends from April 1, 2023 to March 31, 2024. LC34 has been designated Solid Waste Management Unit CC054 under the Kennedy Space Center (KSC) Resource Conservation and Recovery Act Corrective Action Program. The objective of the HC IM at LC34 is to contain the shallow and deep DSZ and surrounding dissolved-phase trichloroethene (TCE) high concentration plume via operation of a hydraulic containment system (HCS). The pre-IM design 300 micrograms per liter (μg/L) TCE groundwater contour was used to establish the deep zone capture area for deep recovery wells, and the shallow zone capture area was defined by the DSZ. The system began operating in 2010, and in 2015, the system was expanded to provide HC for areas within the 300 μg/L TCE groundwater isocontours of HS 3 and 4. In 2018 and 2019, an investigation was conducted to recharacterize the DSZ, which included investigating TCE mass in Layer 7. This data was subsequently used to optimize the pumping rates of the HCS and install additional recovery wells in Layer 7 to more adequately capture residual contaminant mass. The operational period for Year 14 of the HCS was from April 1, 2023 to March 31, 2024. Operational runtime for the system was 94 percent during Year 14, with downtime events attributed to planned maintenance, system repairs, and power outages. As of March 31, 2024, a total of 344,849,634 cumulative gallons of groundwater containing 94,656 pounds of chlorinated volatile organic compounds (CVOCs) have been removed by the HCS. During the reporting period covered under this report, the HCS recovered 31,176,393 gallons and approximately 6,319 pounds of CVOC mass. Total combined influent concentrations of TCE have decreased since startup from approximately 280,000 µg/L (January 2010) to 25,000 µg/L (March 2024). During the reporting period, all effluent concentrations from the HCS (aqueous and vapor) were below regulatory reporting limits, indicating the system continues to operate as intended. Performance monitoring was conducted in January 2024 within the DSZ to evaluate TCE contamination. Groundwater samples were collected via DPT at nine locations, consistent with previous events between 2017 and 2022. Full vertical profile sampling was completed at each DPT from 8 to 98 feet below land surface (bls), at 5-foot intervals. The DPT performance monitoring results are summarized in this PMR. The results revealed TCE remains at concentrations greater than 11,000 µg/L in the DSZ (1-percent solubility, indicative of DNAPL) at eight of the nine DPT locations and at depths ranging from 28 to 98 feet bls. An overall decreasing trend of TCE concentrations was observed in DPT samples during this reporting period, which is a reduction from the previous event (December 2022) and the peak event in December 2021, where TCE percentages appeared to increase in all depth zones because several recovery wells were turned off during the AS pilot study in the DSZ. The maximum TCE concentration in January 2024 was 1,600,000 µg/L in the 53 feet bls depth interval at DPT594 (previous maximum result in 2022 was 1,800,000 µg/L in the 48 feet bls depth interval at DPT599). This maximum concentration in the 53 feet bls depth interval is in the deep capture zone. During the January 2024 DPT event, the largest portion of TCE mass was observed in the 48 feet bls interval above/within Layer 4. This trend remains consistent with previous years and appears to indicate continued mass discharge from Layer 4 (fine-grained unit). In addition to DPT sampling, annual groundwater samples were collected from 11 deep monitoring wells in the DSZ area (Layers 7 and 8) in December 2023 to verify vertical and horizontal delineation. Three of the wells were also sampled biweekly to evaluate operations of recovery well RW21D (screened 86 to 106 feet bls), which was installed in January 2023. Of the Layer 7/8 monitoring sampled only annually, results were non-detect or less than groundwater cleanup target levels GCTLs in December 2023, with the exception of one well, IW45D2, which had a cis-1,2-dichloroethene (cDCE), detection greater than the GCTL. Of the three wells sampled biweekly during the operational period, the well located closest to Layer 7 recovery well RW21D (IW44D2, screened 105 to 115 feet bls) had concentrations of TCE, cDCE and vinyl chloride (VC) greater than GCTLs throughout the operational period, but displayed a decreasing trend since the peak concentrations in September 2023. The maximum TCE concentration during this operational period was 190,000 µg/L at IW44D2 in September 2023, but reduced to 700 µg/L in March 2024, indicating the HCS is still effectively removing mass from the source area. Expansion of the HCS and addition of new recovery wells is ongoing and will continue to be evaluated as the groundwater recovery scheme is optimized. Details of the expansion and optimization will be provided in a future PMR. The HS 6 AS IM was initiated in 2018 with 160 AS wells and expanded in 2019 with another 140 AS wells. An additional expansion of the HS 6 AS IM was completed during the reporting period covered under this report and details of the construction implementation and startup of the expansion are detailed in Section III of this report. The new expansion, referred to as Phase Two, was implemented between August 17, 2022 and August 28, 2023, and included the installation of 190 air sparge wells to treat an additional 11.2 acres. The original configuration (referred to as Phase One) operated until Phase Two came online, then all but 52 AS wells were turned off so the components could be moved and utilized in the Phase Two area. The 52 AS wells that remain on are in a barrier configuration preventing contaminated groundwater from impacting the treated area. The HS 6 AS system (both Phase One and Two) operated normally during the reporting period covered under this report. Semi-annual performance monitoring of the Phase One configuration was conducted in April and November 2023, consistent with previous years. For the Phase Two configuration, 21 new monitoring wells were installed and sampled quarterly, with a baseline event in July 2023, and quarterly events in November 2023 and February 2024 summarized in this report. Semi-annual monitoring results collected in April and October 2023 show concentrations of contaminants of concern (cDCE, trans-1,2-dichloroethene, and VC) have decreased to less than GCTLs in nearly all wells and not impacting the surface water drainage canal, indicating the HS 6 IM continues to meet objectives. The baseline and quarterly sampling for the Phase Two configuration indicate generally decreasing concentrations in wells within and around the perimeter of the treatment area. At least two more quarters of monitoring will be conducted and once those results are evaluated a reduced the sampling frequency may be considered. Overall, the tasks associated with Year 14 operation of the HC IM and operation of the HS 6 AS IM were performed in accordance with recommendations included in the previous 2022 LC34 (Year 13) PMR. Evaluation of results from the HC IM and HS 6 IM show that these systems are operating as designed and meeting performance objectives.

groundwater remediation↗

Stochastic Simulation Tool for Aerospace Structural Analysis

Stochastic simulation refers to incorporating the effects of design tolerances and uncertainties into the design analysis model and then determining their influence on the design. A high-level evaluation of one such stochastic simulation tool, the MSC.Robust Design tool by MSC.Software Corporation, has been conducted. This stochastic simulation tool provides structural analysts with a tool to interrogate their structural design based on their mathematical description of the design problem using finite element analysis methods. This tool leverages the analyst's prior investment in finite element model development of a particular design. The original finite element model is treated as the baseline structural analysis model for the stochastic simulations that are to be performed. A Monte Carlo approach is used by MSC.Robust Design to determine the effects of scatter in design input variables on response output parameters. The tool was not designed to provide a probabilistic assessment, but to assist engineers in understanding cause and effect. It is driven by a graphical-user interface and retains the engineer-in-the-loop strategy for design evaluation and improvement. The application problem for the evaluation is chosen to be a two-dimensional shell finite element model of a Space Shuttle wing leading-edge panel under re-entry aerodynamic loading. MSC.Robust Design adds value to the analysis effort by rapidly being able to identify design input variables whose variability causes the most influence in response output parameters.

Knight, Norman F.↗

Annual Technology Baseline: The 2022 Electricity Update

Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' renewable energy analysts. The ATB has been reviewed by experts and it includes the following electricity generation and storage technologies: land-based wind, offshore wind, distributed wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, utility-scale battery storage, commercial battery storage, residential battery storage, pumped storage hydropower, coal, and natural gas. EIA data for nuclear and conventional biopower are included for reference. This webinar presentation introduces the 2022 update to the ATB Electricity data and documentation.

capacity factor↗

Annual Technology Baseline: The 2023 Electricity Update

Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' renewable energy analysts. The ATB has been reviewed by experts and it includes the following electricity generation and storage technologies: land-based wind, offshore wind, distributed wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, utility-scale battery storage, commercial battery storage, residential battery storage, pumped storage hydropower, coal, and natural gas. EIA data for nuclear and conventional biopower are included for reference. This webinar presentation introduces the 2023 update to the ATB Electricity data and documentation.

capacity factor↗

Substellar objects in nearby young clusters (SONYC). VIII. Substellar population in Lupus 3

SONYC—Substellar Objects in Nearby Young Clusters—is a survey program to investigate the frequency and properties of substellar objects in nearby star-forming regions. We present a new imaging and spectroscopic survey conducted in the young (∼1 Myr), nearby (∼200 pc) star-forming region Lupus 3. Deep optical and near-infrared images were obtained with MOSAIC-II and NEWFIRM at the CTIO 4 m telescope, covering ∼1.4 deg{sup 2} on the sky. The i-band completeness limit of 20.3 mag is equivalent to 0.009-0.02 M {sub ☉}, for A{sub V} ≤ 5. Photometry and 11-12 yr baseline proper motions were used to select candidate low-mass members of Lupus 3. We performed a spectroscopic follow-up of 123 candidates, using VIMOS at the Very Large Telescope, and we identify 7 probable members, among which 4 have spectral type later than M6.0 and T {sub eff} ≤ 3000 K, i.e., are probably substellar in nature. Two of the new probable members of Lupus 3 appear underluminous for their spectral class and exhibit emission line spectrum with strong H{sub α} or forbidden lines associated with active accretion. We derive a relation between the spectral type and effective temperature: T {sub eff} = (4120 ± 175) – (172 ± 26) × SpT, where SpT refers to the M spectral subtype between 1 and 9. Combining our results with the previous works on Lupus 3, we show that the spectral type distribution is consistent with that in other star-forming regions, as well as the derived star-to-brown dwarf ratio of 2.0-3.3. We compile a census of all spectroscopically confirmed low-mass members with spectral type M0 or later.

79 ASTRONOMY AND ASTROPHYSICS↗

Next-Generation Marine Energy Software Needs Assessment

The U.S. Department of Energy (DOE) Water Power Technologies Office’s (WPTO) initial investment in marine energy software was driven by needs identified over a decade ago. WPTO-funded research was first launched because of a U.S. congressional mandate that called for the DOE to officially research marine energy technologies, which also established the DOE WPTO in 2008. A congressional mandate requested the WPTO to evaluate a variety of marine energy devices, establish baseline levelized cost of energy estimates, and provide an overall report to Congress. This congressional mandate led to the Reference Model Project (RMP), for which WPTO funded a national multi-laboratory team to develop these reference models, based on state-of-the-art designs of six marine energy converter archetypes that consisted of three current energy converters and three wave energy converters (WEC). Each device was designed to operate for a specific marine resource, thus allowing the devices to serve as reference models for future studies. The RMP congressional report cited the need for improved marine energy software to handle a variety of device designs, as well as a need to standardize performance outputs. Without validated software packages and established metrics, information presented to the WPTO by technology developers could be incorrect or inaccurate and result in misleading conclusions. The recommendation to coordinate WPTO investment in software for numerical modeling and analysis was given a high priority because it would directly fill needs at the time, and focused funding would amplify impact. By sponsoring software development, WPTO would provide industry developers, university researchers, and national laboratories software that could be used, customized, and advanced, thus supporting the overall advancement of marine energy.

16 TIDAL AND WAVE POWER↗

Low-Speed Aerodynamic Data for an 0.18-Scale Model of an F-16XL with Various Leading-Edge Modifications

Using the F-16XL as a test-bed, two strategies for improving the low-speed flying characteristics that had minimal impact on high-speed performance were evaluated. In addition to the basic F-16XL configuration several modifications to the baseline configuration were tested in the Langley 30- X 60-Foot Tunnel: 1) the notched area at the wing leading edge and fuselage juncture was removed resulting in a continuous 70 deg leading-edge sweep on the inboard portion of the wing; 2) an integral attached-flow leading-edge flap concept was added to the continuous leading edge; and 3) a deployable vortex flap concept was added to the continuous leading edge. The purpose of this report is simply to document the test configurations, test conditions, and data obtained in this investigation for future reference and analysis. No analysis is presented herein and the data only appear in tabulated format.

Hahne, Daniel E.↗

A GPS measurement system for precise satellite tracking and geodesy

NASA is pursuing two key applications of differential positioning with the Global Positioning System (GPS): sub-decimeter tracking of earth satellites and few-centimeter determination of ground-fixed baselines. Key requirements of the two applications include the use of dual-frequency carrier phase data, multiple ground receivers to serve as reference points, simultaneous solution for use position and GPS orbits, and calibration of atmospheric delays using water vapor radiometers. Sub-decimeter tracking will be first demonstrated on the TOPEX oceanographic satellite to be launched in 1991. A GPS flight receiver together with at least six ground receivers will acquire delta range data from the GPS carriers for non-real-time analysis. Altitude accuracies of 5 to 10 cm are expected. For baseline measurements, efforts will be made to obtain precise differential pseudorange by resolving the cycle ambiguity in differential carrier phase. This could lead to accuracies of 2 or 3 cm over a few thousand kilometers. To achieve this, a high-performance receiver is being developed, along with improved calibration and data processing techniques. Demonstrations may begin in 1986.

Yunck, T. P.↗

Frequency-Tuneable Pre-Stabilized Lasers for LISA via Sideband Locking

Laser frequency noise mitigation is one of the most challenging aspects of the LISA interferometric measurement system. The unstabilized frequency fluctuations must be suppressed by roughly twelve orders of magnitude in order to achieve a stability sufficient for gravitational wave detection. This enormous suppression will be achieved through a combination of stabilization and common-mode rejection. The stabilization component will itself be achieved in two stages: pre-stabilization to a local optical cavity followed by arm-locking to some combination of the inter-spacecraft distances. In order for these two stabilization stages to work simultaneously, the lock-point of the pre-stabilization loop must be frequency tunable. The current baseline stabilization technique, locking to an optical cavity, does not provide tunability between cavity resonance, which are typically spaced by 100s of MHz. Here we present a modification to the traditional Pound-Drever-Hall cavity locking technique that allows the laser to be locked to a cavity resonance with an adjustable frequency offset. This technique requires no modifications to the optical cavity itself, thus preserving the stability of the frequency reference. We present measurements of the system stability, demonstrating that the pre-stabilization level satisfies LISA requirements. We also present a demonstration of a phase-lock loop which utilizes the tunable sideband locking technique as a pre-stabilizations tage. The performance of the pre-stabilized phase-lock-loop indicates that the tunable sideband technique will meet the requirements as an actuator for arm-locking in LISA.

Thorpe, James Ira↗

Absence of diurnal variation of C-reactive protein concentrations in healthy human subjects

BACKGROUND: The concentration of C-reactive protein (CRP) in otherwise healthy subjects has been shown to predict future risk of myocardial infarction and stroke. CRP is synthesized by the liver in response to interleukin-6, the serum concentration of which is subject to diurnal variation. METHODS: To examine the existence of a time-of-day effect for baseline CRP values, we determined CRP concentrations in hourly blood samples drawn from healthy subjects (10 males, 3 females; age range, 21-35 years) during a baseline day in a controlled environment (8 h of nighttime sleep). RESULTS: Overall CRP concentrations were low, with only three subjects having CRP concentrations >2 mg/L. Comparison of raw data showed stability of CRP concentrations throughout the 24 h studied. When compared with cutoff values of CRP quintile derived from population-based studies, misclassification of greater than one quintile did not occur as a result of diurnal variation in any of the subjects studied. Nonparametric ANOVA comparing different time points showed no significant differences for both raw and z-transformed data. Analysis for rhythmic diurnal variation using a method fitting a cosine curve to the group data was negative. CONCLUSIONS: Our data show that baseline CRP concentrations are not subject to time-of-day variation and thus help to explain why CRP concentrations are a better predictor of vascular risk than interleukin-6. Determination of CRP for cardiovascular risk prediction may be performed without concern for diurnal variation.

Non-NASA Center↗

Characterizing Detailed Grain Shape and Size Distribution Properties of Lunar Regolith

Introduction: As the nation prepares to return to the Moon, there is an increasing need for testing tools, instruments, and equipment in simulated environments on Earth to ensure successful operations during lunar missions. Regolith will affect all aspects of future lunar missions, from plume interactions during landing to space suit and tool design [1]. Because of this, it is important to understand the grain shape and size properties of lunar regolith and how those influence regolith behavior in order to prepare for these missions. This knowledge is also vital to create more accurate lunar regolith simulants for testing equipment in a lunar environment. While particle size analyses have been performed on most Apollo soils using simple sieving, shape has only been crudely addressed [2]. This work analyzes 4 lunar regolith samples to provide a better understanding of these size and shape parameters and will provide a more accurate baseline of data to create high-fidelity lunar regolith simulants. Methods: New technologies exist today that are capable of measuring size and shape simultaneously for hundreds of thousands of particles in a single measurement. We conducted a rigorous analysis of the particle size distribution (PSD) as well as the size-dependent 2D and 3D shape parameters of lunar regolith samples of different compositions and maturity levels. This analysis was done using a Microtrac SYNC which provides a unique combination of tri-laser diffraction and Dynamic Image Analysis (DIA). Sample Selection. Four regolith samples were selected for analysis based on maturity level and lunar terrain type: • 10084 – Mature high-Ti mare regolith • 15601 – Immature low-Ti mare regolith • 64501 – Mature highland regolith • 67461 – Immature highland regolith Sample Analysis. After receiving the samples, each sample was imaged with an optical microscope (Figure 1). To obtain 2D and 3D particle size and shape, 0.1 g of each sample was then added to the SYNC for analysis, which outputs more than 30 size and shape parameters for each individual grain as well as the complete size distribution from 0.01-2000 μm by blending laser diffraction and DIA together. For the 0.1 g sample masses requested, ~100,000 grains per sample were captured by DIA. Results: From the PSD analysis, it can be seen that the average particle size of 10084 is ~24.5 µm which is much smaller than the average particle size of the Apollo sample collection (~72 µm) [3], while the average particle size of samples 15601, 64501, and 67461 are larger than the Apollo sample average at ~106 µm, ~103 µm, and ~118.5 µm respectively. The size and shape measurements for the samples output ~30 parameters, four of which were focused on for this study: sphericity, aspect ratio, roundness, and concavity (Figure 3). However, after analyzing the plots it was found that only sphericity and aspect ratio showed differences between the samples. These two parameters are measured on a scale from 0 to 1, with 1 being a perfect sphere with equal dimensions. The results show that the sphericity values are slightly high-er for the mature samples 10084 and 64501 (~0.96) than they are for samples 15601 and 67461 (~0.95) (Figure 4). The aspect ratio values are slightly lower for samples 64501 (~0.7) and 67461 (~0.74) than they are for samples 10084 (~0.76) and 15601 (~0.8) (Figure 5). Discussion: Mature regoliths are those that have been exposed to micrometeorite and solar wind bombardment for long periods of time, breaking up particles and causing them to become more rounded [4]. Therefore, the smaller particle sizes and higher sphericity values for samples 10084 and 64501 are expected due to their higher maturity level compared to 15601 and 67461. However, the aspect ratio values are not dependent on maturity and are instead dependent on terrain type. The lower aspect ratio values for the high-land samples is potentially due to the higher plagioclase content, which occurs in elongated particles and does not break down as easily as the pyroxenes or olivines that are present in the mare. Conclusion and Future Work: The results of this work provide a baseline of high-quality data that will contribute to the creation of high-fidelity lunar simulants and will greatly benefit NASA’s efforts of establishing a human presence on the Moon. Future work includes performing unsupervised image classification on the ~105 particle images per sample in order to identify different classes of grains. These grain classes can then be linked to detailed shape properties, and the relative abundance of each class in the samples can be compared. Acknowledgments: We would like to thank the Extraterrestrial Materials Analysis Group (ExMAG) and the Astromaterials Allocation Review Board (AARB) for allocating lunar regolith samples 10084,9010, 15601,365, 64501,249, and 67461,171 for this work. References: [1] Taylor, L. A. et al. (2005) AIAA #2510. [2] Katagiri et al. (2015) ASCE. [3] Carrier III, W. D. (2005) Lunar Geotech Institute Tech Report. [4] McKay, D. S. et al. (1991) The Lunar Sourcebook, Chapter 7.

S R Deitrick↗

Full Life Wind Turbine Gearbox Lubricating Fluids

Industrial gear box lubricants typically are hydrocarbon based mineral oils with considerable amounts of additives to overcome the lack of base fluid properties like wear protection, oxidation stability, load carrying capacity, low temperature solidification and drop of viscosity at higher temperatures. For today's wind turbine gearboxes, the requirements are more severe and synthetic hydrocarbon oils are used to improve on this, but all such hydrocarbon based lubricants require significant amounts of Extreme Pressure (EP) additives to meet performance requirements. Perfluoropolyether (PFPE) fluids provide load carrying capacity as an inherent property. During the course of the project with the main tasks of 'Establish a Benchmark', 'Lubricant Evaluation', 'Full Scale Gearbox Trial' and 'Economic Evaluation', the PAO Reference oil exhibited significant changes after laboratory gear testing, in service operation in the field and full scale gearbox trial. Four hydrocarbon base oils were selected for comparison in the benchmarking exercise and showed variation with respect to meeting the requirements for the laboratory micro-pitting tests, while the PFPE fluid exceeded the requirements even with the material taken after the full scale gear box trial. This is remarkable for a lubricant without EP additives. Laboratory bearing tests performed on the PFPE fluids before and after the full scale gear box trial showed the results met requirements for the industry standard. The PFPE fluid successfully completed the full scale gear box test program which included baseline and progressive staged load testing. The evaluation of gears showed no micro-pitting or objectionable wear. By the final stage, lubricant film thickness had been reduced to just 21% of its original value, this was by design and resulted in a lambda ratio of well below 1.

17 WIND ENERGY↗

AO13. High energy, low methane syngas from low-rank coals for coal-to-liquids production

An experimental program was undertaken to develop and demonstrate novel steam reforming catalysts for converting tars, C2+ hydrocarbons, and methane under high temperature and sulfur environments at lab scale. Several catalysts were developed and synthesized along with some catalysts based on recipes found in the literature. Of these, two had good resistance at 90 ppm H 2 S with one almost not affected at all. Higher concentrations of H 2 S did affect methane conversion across the catalyst, but performance was fairly stable for up to 200 hours. Based on the results of the experimental program, a techno-economic analysis was developed for IGCC and CTL applications and compared to DOE reference cases to examine the effects of the new technology. In the IGCC cases, the reformer/POX system produces nearly the same amount of electricity for nearly the same cost, however, the reformers/POX case sequesters a higher percentage of the carbon when compared to IGCC alone. For the CTL case the economics of the new process were nearly identical to the CTL case, but due to improved yields, the greenhouse gas emissions for a given production of fuels was approximately 50% less than the baseline case.

36 MATERIALS SCIENCE↗

Towards improved and more routine Earth system model evaluation in CMIP

The Coupled Model Intercomparison Project (CMIP) has successfully provided the climate community with a rich collection of simulation output from Earth system models (ESMs) that can be used to understand past climate changes and make projections and uncertainty estimates of the future. Confidence in ESMs can be gained because the models are based on physical principles and reproduce many important aspects of observed climate. More research is required to identify the processes that are most responsible for systematic biases and the magnitude and uncertainty of future projections so that more relevant performance tests can be developed. At the same time, there are many aspects of ESM evaluation that are well established and considered an essential part of systematic evaluation but have been implemented ad hoc with little community coordination. Given the diversity and complexity of ESM analysis, we argue that the CMIP community has reached a critical juncture at which many baseline aspects of model evaluation need to be performed much more efficiently and consistently. We provide a perspective and viewpoint on how a more systematic, open, and rapid performance assessment of the large and diverse number of models that will participate in current and future phases of CMIP can be achieved, and announce our intention to implement such a system for CMIP6. Accomplishing this could also free up valuable resources as many scientists are frequently "re-inventing the wheel" by re-writing analysis routines for well-established analysis methods. A more systematic approach for the community would be to develop and apply evaluation tools that are based on the latest scientific knowledge and observational reference, are well suited for routine use, and provide a wide range of diagnostics and performance metrics that comprehensively characterize model behaviour as soon as the output is published to the Earth System Grid Federation (ESGF). The CMIP infrastructure enforces data standards and conventions for model output and documentation accessible via the ESGF, additionally publishing observations (obs4MIPs) and reanalyses (ana4MIPs) for model intercomparison projects using the same data structure and organization as the ESM output. This largely facilitates routine evaluation of the ESMs, but to be able to process the data automatically alongside the ESGF, the infrastructure needs to be extended with processing capabilities at the ESGF data nodes where the evaluation tools can be executed on a routine basis. Efforts are already underway to develop community-based evaluation tools, and we encourage experts to provide additional diagnostic codes that would enhance this capability for CMIP. And, at the same time, we encourage the community to contribute observations and reanalyses for model evaluation to the obs4MIPs and ana4MIPs archives. The intention is to produce through the ESGF a widely accepted quasi-operational evaluation framework for CMIP6 that would routinely execute a series of standardized evaluation tasks. Over time, as this capability matures, we expect to produce an increasingly systematic characterization of models which, compared with early phases of CMIP, will more quickly and openly identify the strengths and weaknesses of the simulations. This will also reveal whether long-standing model errors remain evident in newer models and will assist modelling groups in improving their models. Finally, this framework will be designed to readily incorporate updates, including new observations and additional diagnostics and metrics as they become available from the research community.

54 ENVIRONMENTAL SCIENCES↗

Preliminary Medical Risk Estimates and Clinical Capability Needs for Artemis IV

BACKGROUND Human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in- mission medical care. Compared with the ISS, the greater distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and significant limitations on the evacuation of ill or injured crew. Spacecraft mass, volume, and power will be curtailed while higher demands will be placed on the crew’s knowledge, skills, and abilities. In this higher risk environment, it is important to: a) quantitatively estimate human system risk attributable to medical conditions, a process known as Probabilistic Risk Analysis, and b) use these estimates to inform medical system design. IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a PRA and medical trade space analysis tool developed by NASA to advance exploration mission medical system design. IMPACT v1.0 improves upon and will soon replace NASA’s existing tool, the Integrated Medical Model, with: a novel evidence base baselined to exploration environments; an expanded list of 119 medical conditions; a significant increase in the number of medical resources that can be utilized and in the flexibility of their use; and the modelling of time lost performing mission-specific tasks due to medical conditions. METHODOLOGY: This abstract will present IMPACT estimates of medical system risk and clinical capability needs for the Artemis IV mission. Artemis IV is currently scheduled for 2026 and will visit the Gateway space station in lunar orbit prior to the second lunar landing of the Artemis program. The baseline Artemis IV mission that was modeled was 28 days in duration with phases including Orion outbound, 4 days on the Gateway space station in lunar orbit, 2 crew on the surface of the Moon for approximately one week, an additional 5 days on Gateway, and then return to Earth. This baseline was compared to two alternative 34-day design reference missions (DRMs) that shifted the lunar sortie earlier or later in the mission profile. Assumptions included 2 female and 2 male crew and a notional medical system mass of 25 kg. Medical system risk estimates include loss of crew life (LOCL), consideration of medical evacuation (known as return to definitive care – RTDC), and an estimate of crew time lost due to medical conditions (Task Time Lost – TTL). The presentation will also describe the medical conditions that are the greatest drivers of risk as well as the clinical capabilities and resources that have the largest effect on risk. RESULTS: All three DRMs had very low probability of LOCL from medical conditions, primarily due to short duration. RTDC was also similar across the DRMs. In contrast, TTL was higher in the early lunar sortie DRM due to earlier occurrence of EVA-related medical conditions. Taken as a whole, there was no clinically significant difference in medical risk across the three missions. Results for clinical capabilities and an example medical equipment list will be discussed but were similar across DRMs.

D Hilmers↗

Preliminary Medical Risk Estimates and Clinical Capability Needs for Late Artemis Missions

BACKGROUND Human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in- mission medical care. Compared with the ISS, the greater distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and significant limitations on the evacuation of ill or injured crew. Spacecraft mass, volume, and power will be curtailed while higher demands will be placed on the crew’s knowledge, skills, and abilities. In this higher risk environment, it is important to: a) quantitatively estimate human system risk attributable to medical conditions, a process known as Probabilistic Risk Analysis, and b) use these estimates to inform medical system design. IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a PRA and medical trade space analysis tool developed by NASA to advance exploration mission medical system design. IMPACT v1.0 improves upon and will soon replace NASA’s existing tool, the Integrated Medical Model, with: a novel evidence base baselined to exploration environments; an expanded list of 119 medical conditions; a significant increase in the number of medical resources that can be utilized and in the flexibility of their use; and the modelling of time lost performing mission-specific tasks due to medical conditions. METHODOLOGY: This abstract will present IMPACT estimates of medical system risk and clinical capability needs for the Artemis IV mission. Artemis IV is currently scheduled for 2026 and will visit the Gateway space station in lunar orbit prior to the second lunar landing of the Artemis program. The baseline Artemis IV mission that was modeled was 28 days in duration with phases including Orion outbound, 4 days on the Gateway space station in lunar orbit, 2 crew on the surface of the Moon for approximately one week, an additional 5 days on Gateway, and then return to Earth. This baseline was compared to two alternative 34-day design reference missions (DRMs) that shifted the lunar sortie earlier or later in the mission profile. Assumptions included 2 female and 2 male crew and a notional medical system mass of 25 kg. Medical system risk estimates include loss of crew life (LOCL), consideration of medical evacuation (known as return to definitive care – RTDC), and an estimate of crew time lost due to medical conditions (Task Time Lost – TTL). The presentation will also describe the medical conditions that are the greatest drivers of risk as well as the clinical capabilities and resources that have the largest effect on risk. RESULTS: All three DRMs had very low probability of LOCL from medical conditions, primarily due to short duration. RTDC was also similar across the DRMs. In contrast, TTL was higher in the early lunar sortie DRM due to earlier occurrence of EVA-related medical conditions. Taken as a whole, there was no clinically significant difference in medical risk across the three missions. Results for clinical capabilities and an example medical equipment list will be discussed but were similar across DRMs.

D. Hilmers↗

Fat Composition Changes in Bone Marrow During Chemotherapy and Radiation Therapy

Purpose: To quantify changes in bone marrow fat fraction and determine associations with peripheral blood cell counts. Methods and Materials: In this prospective study, 19 patients received either highly myelotoxic treatment (radiation therapy plus cisplatin, 5-fluorouracil mitomycin C [FU/MMC], or cisplatin/5-FU/cetuximab) or less myelotoxic treatment (capecitabine-radiation therapy or no concurrent chemotherapy). Patients underwent MR imaging and venipuncture at baseline, midtreatment, and posttreatment visits. We performed mixed effects modeling of the mean proton density fat fraction (PDFF[%]) by linear time, treatment, and vertebral column region (lumbar [L]4-sacral [S]2 vs thoracic [T]10-L3 vs cervical[C]3-T9), while controlling for cumulative mean dose and other confounders. Spearman rank correlations were performed by white blood cell (WBC) counts versus the differences in PDFF(%) before and after treatment. Results: Cumulative mean dose was associated with a 0.43% per Gy (P=.004) increase in PDFF(%). In the highly myelotoxic group, we observed significant changes in PDFF(%) per visit within L4-S2 (10.1%, P<.001) and within T10-L3 (3.93%, P=.01), relative to the reference C3-T9. In the less myelotoxic group, we did not observe significant changes in PDFF(%) per visit according to region. Within L4-S2, we observed a significant difference between treatment groups in the change in PDFF(%) per visit (5.36%, P=.04). Rank correlations of the inverse log differences in WBC versus the differences in PDFF(%) overall and within T10-S2 ranged from 0.69 to 0.78 (P<.05). Rank correlations of the inverse log differences in absolute neutrophil counts versus the differences in PDFF(%) overall and within L4-S2 ranged from 0.79 to 0.81 (P<.05). Conclusions: Magnetic resonance imaging fat quantification is sensitive to marrow composition changes that result from chemoradiation therapy. These changes are associated with peripheral blood cell counts. This study supports a rationale for bone marrow-sparing treatment planning to reduce the risk of hematologic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Semispan Test Results of a Conventional High-Lift Common Research Model in Landing Configuration

A 10%-scale high-lift version of the Common Research Model (CRM-HL) was tested in the 14- by 22-Foot Subsonic Tunnel at the NASA Langley Research Center. This research was aimed at providing a representative reference case for comparison with an Active Flow Control (AFC) enabled version of the CRM-HL and to increase the existing experimental database for CFD high-lift prediction. The test was conducted mostly at a freestream Mach number of 0.20. The effects of the engine nacelle, nacelle chine, tufts, small variations in Mach number, hysteresis-associated increasing/decreasing angle of attack, and incoming floor boundary-layer thickness (i.e., thinning by activation of the floor boundary layer removal system) were examined. A prestall lift performance degradation for the CRM-HL configuration was resolved with a properly placed nacelle chine. Surface pressure results are presented in detail for three key variants of CRM-HL — baseline (nacelle on), nacelle off, and nacelle with the most effective chine installation. The presented aerodynamic forces and surface pressures include both with and without the wall correction using the Transonic Wall Interference Correction System (TWICS) method. A limited set of photogrammetry results is also presented to document the model deformation under test conditions.

high-lift↗