Search NASA⌕ Search

SEARCH · Search NASA

Results for “building services”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

2023 Status Report - Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC

Thermal, mechanical, and physical properties have been measured on fiberboard samples aging for up to 18 years at accelerated conditions. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2024 Status Report - Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC

Fiberboard assemblies in the 9975 package were identified as susceptible to aging and degradation under long-term storage conditions. Thermal, mechanical, and physical properties have been measured on fiberboard samples aging for up to 19 years at accelerated conditions. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions.

36 MATERIALS SCIENCE↗

2025 Status Report - Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC

Fiberboard assemblies in the 9975 package were identified as susceptible to aging and degradation under long-term storage conditions. Thermal, mechanical, and physical properties have been measured on fiberboard samples aging for up to 20 years at accelerated conditions. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 containers in storage from 20 years to 40 years. These calculations addressed the potential for degraded fiberboard properties following 40 years in storage using degradation models. The 40 year storage evaluations assumed the degradation rates from initial values for density, dimensional, and thermal properties were 0.5% per year (i.e., after 40 years, the density, dimensional, and thermal properties of fiberboard were 80% of its initial values). The updated degradation models developed in this report were compared to the assumptions in those calculations, and the current results for fiberboard dimensions, density, axial and radial thermal conductivities, and energy absorption remain consistent with those calculations. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are purposely high to accelerate aging. These rates relate to environments that do not exist within KAC or are postulated to only occur as upset conditions that are unlikely to persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 ºF, the fiberboard assemblies experience storage conditions less severe than any of the aging environments (i.e., under 125 °F) used in this study. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 40 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 40 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of nonconforming conditions such as the presence of excess moisture and mold or beetle infestations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Growing Insulation in Alaska

Buildings produce 40% of all carbon emissions in the U.S. This includes the energy needed to heat, cool, and power the nation's buildings and the energy used to manufacture, ship, and assemble the construction materials. In extreme climates and remote regions, buildings use even more energy, as building materials must be produced and shipped farther to the site, increasing the greenhouse gas emissions embodied in the buildings. The U.S. National Renewable Energy Laboratory (NREL) is developing technologies that reduce how much energy our buildings use and how much carbon goes into them in the first place. NREL researchers teamed up with the Biomaterials Laboratory at the University of Alaska, U.S. Forest Service Forest Products Lab, and the VTT Centre of Finland on a three-year project to "grow" insulation using trees in Alaska - improving the efficiency of buildings by providing envelope retrofit options using local resources.

carbon negative building↗

Data Integration Support for Data Served in the OPeNDAP and OGC Environments

NASA is coordinating a technology development project to construct a gateway between system components built upon the Open-source Project for a Network Data AcceSs Protocol (OPeNDAP) and those made available made available via interfaces specified by the Open Geospatial Consortium (OGC). This project is funded though the Advanced Collaborative Connections for Earth-Sun System Science (ACCESS) Program and is a NASA contribution to the Committee on Earth Satellites (CEOS) Working Group on Information Systems and Services (WGISS). The motivation for the project is the set of data integration needs that have been expressed by the Coordinated Enhanced Observing Period (CEOP), an international program that is addressing the study of the global water cycle. CEOP is assembling a large collection in situ and satellite data and mode1 results from a wide variety of sources covering 35 sites around the globe. The data are provided by systems based on either the OPeNDAP or OGC protocols but the research community desires access to the full range of data and associated services from a single client. This presentation will discuss the current status of the OPeNDAP/OGC Gateway Project. The project is building upon an early prototype that illustrated the feasibility of such a gateway and which was demonstrated to the CEOP science community. In its first year as an ACCESS project, the effort has been has focused on the design of the catalog and data services that will be provided by the gateway and the mappings between the metadata and services provided in the two environments.

McDonald, Kenneth R.↗

Flexibility Estimation and Control of Thermostatically Controlled Loads with Lock Time for Regulation Service

A virtual battery model is a simple and general method to quantify aggregate flexibility from thermostatically controlled loads (TCLs), enabling grid operators to effectively coordinate a large number of flexible building loads with supplyside resources in power systems. Lockout controls are designed to avoid wear and tear resulting from short-cycling of hardware. The lock on/off time could significantly affect aggregate flexibility from TCLs to provide ancillary services and may even fail control algorithms designed without considering the lock time constraints. This paper focuses on flexibility estimation and control design for TCLs with lock time constraints to provide frequency regulation service. We first investigate the potential impacts of lock time on TCLs’ aggregate flexibility and control performance. Both control-dependent and control-independent power bounds are derived, based on either previous TCL switching operations or regulation signals. While the control-dependent method provides aggregate flexibility for a given control method, the control-independent method calculates the theoretical maximum of power bounds. Two control algorithms are proposed to better distribute flexibility over time and thereby improve signal tracking performance. The proposed methods are illustrated and validated through simulations.

Wang, Peng↗

Event-Based Energy Impact Tracking and Forecasting with Limited Measurements for Rooftop Units

Packaged air conditioning units and heat pumps, also known as rooftop units (RTUs), are responsible for almost 133 billion kWh of electricity usage annually on site for space cooling U.S. commercial buildings. In addition, the use of heat pumps is a trend we expect to accelerate as buildings transition from fossil fuel-based heating to electricity as a key step for decarbonizing the U.S. commercial buildings sector. However, the operation conditions and energy use of RTUs and heat pumps are usually not well monitored as they are not commonly integrated with building automation systems and lack exposed sensing and control points. To fill this gap, this paper proposes a framework for tracking and forecasting energy impacts resulting from degradation of performance and improved performance for unit servicing using limited data. The proposed framework makes use of a constrained dataset, specifically measurements of the outdoor air temperature and the power demand of individual RTUs, to track and forecast changes in energy use associated with changes in performance over various temporal horizons ranging from days to weeks. Following the detection of an RTU fault, performance degradation, or performance improvement, the framework employs a prediction model to assess the cumulative energy impact. We demonstrate the effectiveness of the method with field-collected data for servicing and degradation examples and compare the predicting accuracy of Gradient Boosting Decision Tree (GBDT) Regression models to Support Vector Regression and Linear Regression models. The results show that GBDT achieved the best accuracy for time-series validation datasets for the servicing and degradation cases, and the prediction model was able to track the cumulative energy impacts of events. The proposed framework can inform building owners of the cumulative change in energy usage of RTUs associated with performance degradation, performance improvement, or a fault.

packaged air conditioners, packaged heat pumps, ro↗

Energy Master Planning for Resilient Public Communities—Best Practices from U.S. Military Installations

Until recently, most planners at military installations addressed energy systems for new facilities on an individual facility basis without consideration of community-wide goals relevant to energy sources, renewables, storage, or future energy generation needs. Building retrofits of public buildings typically do not address energy needs beyond the minimum code requirements making it difficult, if not impossible, to achieve community-level targets on a building-by-building basis. Planning on the basis of cost and general reliability may also fail to deliver community-level resilience. For example, many building code requirements focus on hardening to specific threats, but in a multi-building community, only a few of these buildings may be mission-critical. Over the past two decades, the frequency and duration of regional power outages and water utility disruptions from weather, man-made events, and aging infrastructure have increased. Major disruptions of electric and thermal energy have degraded critical mission capabilities and caused significant economic impacts. In 2016, the U.S. Department of Defense issued guidance that each Service (Army, Navy, Air Force, Marines) complete comprehensive energy plans for the installations that consumed 75% of total building energy. Guidance was updated in 2017 to include metrics for energy resilience, and in some cases, water. This paper describes how community level quantitative and qualitative resilience analysis and metrics have been incorporated into community energy and water planning best practices for military installations in three geographically diverse locations. It is based on research performed under the International Energy Agency’s “Energy in Buildings and Communities Program Annex 73,” focusing on development of guidelines and tools that support the planning of Net Zero Energy Resilient Public Communities as well as research performed under the Department of Defense Environmental Security Technology Certification Program project EW18-D1- 5281, “Technologies Integration to Achieve Resilient, Low- Energy Military Installations.” The first case study reviews progress made on an energy and water planning study conducted at Fort Bliss, Texas. The second and third describes planning conducted at Fort Bragg, North Carolina and the Joint Region Marianas, Guam, respectively, under the updated guidance from 2017 regarding energy and water resilience. Analysis methods, key metrics, and key infrastructure and operational constraints are described, as well as technical, economic and business concepts used during the planning process.

Urban, Angela B.↗

Demonstration of Intelligent HVAC Load Management With Deep Reinforcement Learning: Real-World Experience of Machine Learning in Demand Control

We report that buildings account for 40% of total primary energy consumption and 30% of all CO 2 emissions worldwide. A large portion of building energy consumption is due to heating, ventilation, and air-conditioning (HVAC) systems. In the summer, for example, more than 50% of a building’s electricity consumption is used for cooling. With proper energy management, buildings can provide load shifting, peak shaving, frequency regulation, and many other demand response services.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Behind-the-Meter Battery Storage: Frequently Asked Questions

This quick read provides concise answers to frequently asked questions about behind-the-meter (BTM) storage systems. It includes a basic introduction to BTM energy storage and the services it can provide and helps dispel some common misconceptions. It touches on the building blocks that support BTM storage deployment and its safe incorporation into power system operations. Examples and best practices from advanced jurisdictions that can be applied elsewhere are also included.

25 ENERGY STORAGE↗

Eaton High Impact Project (Cooperative Research and Development Final Report)

The NREL team will partner with Eaton to evaluate control strategies for managing Electric bus (E-bus) fleets for grid services. NREL will develop a replicable platform for evaluating EV fleet management and quantifying benefits from grid services. The proposal will cover the technology areas of solar, energy storage, mobility, and buildings.

33 ADVANCED PROPULSION SYSTEMS↗

LandScan Mosaic Rapid Population Update: Jamaica After Hurricane Melissa (V1)

During a natural disaster such as Hurricane Melissa, understanding where people are located is critical for situational awareness, operational planning and humanitarian support and consequence assessment. Traditional population datasets focus on mapping populations based on residential, or "business-as-usual" scenarios. However, natural disasters can create disruptions in daily routines of population in addition to the magnitude of the population displacement, depending on the type, duration, context, and location of the event. The Geospatial Science and Human Security Division at Oak Ridge National Laboratory (ORNL) produced this latest LandScan Mosaic Rapid Population Update for Jamaica following Hurricane Melissa, a category 5 hurricane that made landfall on Jamaica on October 28 2025. This Rapid Population Update captures the immediate population displacement following the hurricane using a combination of open-source building damage assessment data from Microsoft, flood exposure data from the Global Flood Monitoring service, reported population displacement information, and humanitarian shelter locations from the Jamaican Office of Disaster Preparedness and Emergency Management and the underlying LandScan Mosaic Jamaica as a base population.

97 MATHEMATICS AND COMPUTING↗

Earth observing system (Eos) requirements for a polar platform

This paper describes the requirements that the polar platform will have to meet if it is to satisfy the needs of the scientific earth observation communities in the early 1990s. The Eos is a prime mission for the polar platform. The polar platform will be a large satellite in a sun synchronous orbit that could be built up from the same components that are to be used to build the Space Station and its co-orbiting freeflying satellite. It will be serviced from the Shuttle so that it will be kept in operation and up-to-date for at least a decade. An initial set of scientific requirements has been documented by a Science and Missions Requirements Working Group (S&MRWG). These scientific requirements have been translated into derived technical requirements for the polar platform. These derived requirements are presented.

Muller, R. M.↗

A prediction model of signal degradation in LMSS for urban areas

A prediction model of signal degradation in a Land Mobile Satellite Service (LMSS) for urban areas is proposed. This model treats shadowing effects caused by buildings statistically and can predict a Cumulative Distribution Function (CDF) of signal diffraction losses in urban areas as a function of system parameters such as frequency and elevation angle and environmental parameters such as number of building stories and so on. In order to examine the validity of the model, we compared the percentage of locations where diffraction losses were smaller than 6 dB obtained by the CDF with satellite visibility measured by a radiometer. As a result, it was found that this proposed model is useful for estimating the feasibility of providing LMSS in urban areas.

Matsudo, Takashi↗

ScyFlow: An Environment for the Visual Specification and Execution of Scientific Workflows

With the advent of grid technologies, scientists and engineers are building more and more complex applications to utilize distributed grid resources. The core grid services provide a path for accessing and utilizing these resources in a secure and seamless fashion. However what the scientists need is an environment that will allow them to specify their application runs at a high organizational level, and then support efficient execution across any given set or sets of resources. We have been designing and implementing ScyFlow, a dual-interface architecture (both GUT and APT) that addresses this problem. The scientist/user specifies the application tasks along with the necessary control and data flow, and monitors and manages the execution of the resulting workflow across the distributed resources. In this paper, we utilize two scenarios to provide the details of the two modules of the project, the visual editor and the runtime workflow engine.

McCann, Karen M.↗

Iceproofing Helicopters

NASA aircraft-icing research has been applied to expand the utility of the big flying-crane helicopter built by the Sikorsky Aircraft Division of United Technologies in Stratford, Conn. Sikorsky wanted to adapt the Skycrane, used in both military and commercial service, to lift heavy external loads in areas where icing conditions occur; ice build-up around the engine air inlets caused the major problem. NASA-Lewis has a special wind tunnel for injecting super cooled water droplets into the wind thereby simulating a natural icing cloud and observing how ice builds up on various shaped surfaces. From Lewis, Sikorsky engineers obtained information which optimized the design of the inlet anti-ice system. The resulting design proved to be an effective anti-icing modification for the flying crane. Sikorsky is also using additional Lewis Icing Research Tunnel data in its development of a new VTOL (Vertical Take-Off and Landing) aircraft.

Source record↗

How Public Private Partnerships Enable NASA Future Space Communication Needs

The NASA Space Communications and Navigation (SCaN) Program is responsible for providing communication and navigation services to scientific and human space exploration missions. SCaN's current Space Network provides radio frequency (RF) relay services to near Earth space missions via Tracking and Data Relay Satellites (TDRS). SCaN plans to offer a new generation of relay services beginning in 2025, including the addition of optical communications capabilities and enhanced RF capabilities. The primary drivers behind the development of these next generation relay network services are to enhance communication and navigation services with significantly reduced development and operational costs. Several approaches being considered for implementation of these services are through government owned capabilities, through commercial service providers, or a combination of the two. One approach receiving a great deal of attention is the use of Public-Private Partnerships (PPP) to develop and provide capabilities or services. Utilizing Public-Private Partnerships allows NASA and commercial entities to share the investment, standards, and risks of developing and testing new or enhanced capabilities which can benefit both NASA and the commercial space communication industry. The capabilities developed under the PPP can then be used to support the growth of the commercial satellite communications industry while simultaneously being introduced into NASA operations to provide service to future NASA missions as part of the NASA Next Generation Architecture. Partnerships formed for this purpose can also serve as the basis for further NASA acquisition activities where government and industry can continue to share the cost, risk, and benefits of space communications capability development and operations. This objective is consistent with the 2010 National Space Policy stated principles: "The United States is committed to encouraging and facilitating the growth of a U.S. commercial space sector that supports U.S. needs, is globally competitive, and advances U.S. leadership in the generation of new markets and innovation-driven entrepreneurship." [1]NASA has conducted several internal studies as well as externally funded studies with industry to define the next generation space communication architecture. NASA has approached the commercial industry through a Request for Information (RFI) to define further the next generation architecture and has conducted numerous internal and external studies. The results are promising and are shaping the approach to utilize Public Private Partnership to achieve NASA's objectives while reducing costs. The commercial satellite industry has begun to deploy high performance, high throughput global satellite constellations which have the potential to provide communication services to NASA Missions. Commercial satellite manufacturers have advanced their processes to rapidly design, build, and deliver, reliable communication satellites using minimum government oversight. In this paper, we will 1) describe the NASA Next Generation Architecture, Concept of Operations (ConOps), and salient characteristics; 2) Discuss the rational of Public-Private Partnerships to achieve NASA’s next generation communication architecture; and 3) Summarize the preliminary analysis performed to date and describe the path forward.

Stegeman, James↗

A Systems Model for System-Wide Safety Safety Demonstrator (SD-1): Wildfire Response Operations

The aim of this internship-based project was to contribute to the ongoing development of a systems model for System-Wide Safety’s first Technical Challenge 5 (TC5) series Safety Demonstrator (SD-1), which will be a demonstration of an In-Time Aviation Safety Management System (IASMS) in emerging wildfire response operations. Using Models-Based Systems Engineering (MBSE) principles to develop the model, I organized and traced previously collected stakeholder needs from the Spring 2022 NASA System-Wide Safety Wildland Firefighting Operations Virtual Workshop (https://nari.arc.nasa.gov/sws-wildfire) to system elements, creating connections which can be used in the future by the project engineers to identify and address requirements gaps throughout the system design process. I also identified and modeled preliminary use case scenarios for aerial assets in the demonstrator and, building on previously produced preliminary high-level models of the 8 SD-1 Services, Functions, and Capabilities (SFCs) and their IASMS data flows, worked to model the Real-Time Risk Assessment (RTRA) tool as an implementation of Risk Assessment and Management that can take in multiple sets of data monitored by SFCs. Project deliverables include stakeholder requirements tables and matrices and systems model diagrams produced with MagicDraw software in the SysML Systems Modeling Language, with eventual plans to connect model diagrams to a Department of Defense Operational Viewpoint (OV-1) graphic, a high-level operational concept graphic that will be used to visualize the SD-1 scenarioin a future phase. The system model serves to provide a common understanding of the scope of and activities necessary for the completion of SD-1,and traces how stakeholder needs are to be addressed.

model-based systems engineering↗