Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacitance sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Amplitude-Stabilized Oscillator for a Capacitance-Probe Electrometer

A multichannel electrometer voltmeter that employs a mechanical resonator maintained in sustained amplitude-stabilized oscillation has been developed for the space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM) sensor. The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Creating a stable oscillator from the mechanical resonator was achieved by employing magnetic induction for sensing the resonator s velocity, and forcing a current through a coil embedded in the resonator to produce a Lorentz actuation force that overcomes the resonator s dissipative losses. Control electronics employing an AGC loop provide conditions for stabilized, constant amplitude harmonic oscillation. The prototype resonator was composed of insulating FR4 printed-wireboard (PWB) material containing a flat, embedded, rectangular coil connected through flexure springs to a base PWB, and immersed in a magnetic field having two regions of opposite field direction generated by four neodymium block magnets. In addition to maintaining the mechanical movement needed for the electrometer s capacitor-probe transducer, this oscillator provides a reference signal for synchronous detection of the capacitor probe s output signal current so drift of oscillation frequency due to environmental effects is inconsequential.

Blaes, Brent R.↗

Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer

A multi-channel electrometer voltmeter that employs self-nulling lock-in detection electronics in conjunction with a mechanical resonator with noncontact voltage sensing electrodes has been developed for space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM). The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Use of an AC-coupled lock-in amplifier with closed-loop sense-signal nulling via generation of an active guard-driving feedback voltage provides the resolution, accuracy, linearity and stability needed for long-term space-based measurement of the IESDM. This implementation relies on adjusting the feedback voltage to drive the sense current received from the resonator s variable-capacitance-probe voltage transducer to approximately zero, as limited by the signal-to-noise performance of the loop electronics. The magnitude of the sense current is proportional to the difference between the input voltage being measured and the feedback voltage, which matches the input voltage when the sense current is zero. High signal-to-noise-ratio (SNR) is achieved by synchronous detection of the sense signal using the correlated reference signal derived from the oscillator circuit that drives the mechanical resonator. The magnitude of the feedback voltage, while the loop is in a settled state with essentially zero sense current, is an accurate estimate of the input voltage being measured. This technique has many beneficial attributes including immunity to drift, high linearity, high SNR from synchronous detection of a single-frequency carrier selected to avoid potentially noisy 1/f low-frequency spectrum of the signal-chain electronics, and high accuracy provided through the benefits of a driven shield encasing the capacitance- probe transducer and guarded input triaxial lead-in. Measurements obtained from a 2- channel prototype electrometer have demonstrated good accuracy (|error| < 0.2 V) and high stability. Twenty-four-hour tests have been performed with virtually no drift. Additionally, 5,500 repeated one-second measurements of 100 V input were shown to be approximately normally distributed with a standard deviation of 140 mV.

Blaes, Brent R.↗

Circuit for Communication Over Power Lines

Many distributed systems share common sensors and instruments along with a common power line supplying current to the system. A communication technique and circuit has been developed that allows for the simple inclusion of an instrument, sensor, or actuator node within any system containing a common power bus. Wherever power is available, a node can be added, which can then draw power for itself, its associated sensors, and actuators from the power bus all while communicating with other nodes on the power bus. The technique modulates a DC power bus through capacitive coupling using on-off keying (OOK), and receives and demodulates the signal from the DC power bus through the same capacitive coupling. The circuit acts as serial modem for the physical power line communication. The circuit and technique can be made of commercially available components or included in an application specific integrated circuit (ASIC) design, which allows for the circuit to be included in current designs with additional circuitry or embedded into new designs. This device and technique moves computational, sensing, and actuation abilities closer to the source, and allows for the networking of multiple similar nodes to each other and to a central processor. This technique also allows for reconfigurable systems by adding or removing nodes at any time. It can do so using nothing more than the in situ power wiring of the system.

Krasowski, Michael J.↗

Electrostatic Regolith Interaction Experiment (ERIE) Electrometer Instrument Development

The Electrostatic Regolith Interaction Experiment (ERIE) is a joint venture between the University of Central Florida (UCF) Center for Microgravity Research (CMR) and the NASA Kennedy Space Center (KSC) Electrostatics and Surface Physics Laboratory (ESPL) seeking to examine charged dust grain behavior in a microgravity environment. Two separate systems have been combined for this suborbital flight experiment: the COLLisions Into Dust Experiment (COLLIDE) developed by the UCF CMR and the Wheel Electrostatic Spectrometer (WES) developed by the NASA KSC ESPL. This combination will advance the understanding of the natural and induced charged grain behavior on the Moon, asteroids, and other low gravity bodies comprised of charged dust particles. COLLIDE retains granular material under vacuum in a shallow tray behind a metal door, which then opens and releases the particles into a larger open volume when microgravity is achieved. The experiment is observed with a high-speed camera, such that the motions of these particles can then be tracked so the kinematics of each grain may be analyzed. The original application for this apparatus was to study cratering events into granular beds, but electrostatic repulsion was detected in the early frames of the video data returned from completed experiments, so a re-flight with a focus on these events was proposed. Agitation of the grains during launch combined with the frictional charge transfer between the grains and the door as it slides open provides an opportunity to use this setup to observe material tribocharging and charged particle behaviors in microgravity. In this updated version, the charged particles released into the chamber will traverse through an electric field produced by high voltage parallel plates and their resulting trajectories will be determined by their net charges. WES was originally developed to characterize the triboelectric properties of the Martian regolith through the contact of a rover wheel with the surface as it rotates. Improvements were made upon this legacy system to develop a sensor suite that will be installed within the COLLIDE door to measure charge transferred between the granular material and insulating disks protruding through the door. These insulator disks span the triboelectric series so, as they slide across the particulate matter when the door opens, each will accumulate a charge consistent with its relative position to the grains within the series. This charge on each insulator is distributed between two capacitances in series with an electrometer amplifier returning an analog voltage proportional to the charge accumulated. Calibration of this system has been performed using applications of known charge to the inputs and characterization of the frictional charge transfer between various regolith simulants and the sensor insulators is currently being examined in the lab.

Electrostatics↗

Carbon-Nanotube Schottky Diodes

Schottky diodes based on semiconducting single-walled carbon nanotubes are being developed as essential components of the next generation of submillimeter-wave sensors and sources. Initial performance predictions have shown that the performance characteristics of these devices can exceed those of the state-of-the-art solid-state Schottky diodes that have been the components of choice for room-temperature submillimeter-wave sensors for more than 50 years. For state-of-the-art Schottky diodes used as detectors at frequencies above a few hundred gigahertz, the inherent parasitic capacitances associated with their semiconductor junction areas and the resistances associated with low electron mobilities limit achievable sensitivity. The performance of such a detector falls off approximately exponentially with frequency above 500 GHz. Moreover, when used as frequency multipliers for generating signals, state-of-the-art solid-state Schottky diodes exhibit extremely low efficiencies, generally putting out only micro-watts of power at frequencies up to 1.5 THz. The shortcomings of the state-of-the-art solid-state Schottky diodes can be overcome by exploiting the unique electronic properties of semiconducting carbon nanotubes. A single-walled carbon nanotube can be metallic or semiconducting, depending on its chirality, and exhibits high electron mobility (recently reported to be approx.= 2x10(exp 5)sq cm/V-s) and low parasitic capacitance. Because of the narrowness of nanotubes, Schottky diodes based on carbon nanotubes have ultra-small junction areas (of the order of a few square nanometers) and consequent junction capacitances of the order of 10(exp -18) F, which translates to cutoff frequency >5 THz. Because the turn-on power levels of these devices are very low (of the order of nano-watts), the input power levels needed for pumping local oscillators containing these devices should be lower than those needed for local oscillators containing state-of-the-art solid-state Schottky diodes.

Manohara, Harish↗

Metal oxide coating of carbon supports for supercapacitor applications.

The global market for wireless sensor networks in 2010 will be valued close to $10 B, or 200 M units. TPL, Inc. is a small Albuquerque based business that has positioned itself to be a leader in providing uninterruptible power supplies in this growing market with projected revenues expected to exceed $26 M in 5 years. This project focused on improving TPL, Inc.'s patent-pending EnerPak{trademark} device which converts small amounts of energy from the environment (e.g., vibrations, light or temperature differences) into electrical energy that can be used to charge small energy storage devices. A critical component of the EnerPak{trademark} is the supercapacitor that handles high power delivery for wireless communications; however, optimization and miniaturization of this critical component is required. This proposal aimed to produce prototype microsupercapacitors through the integration of novel materials and fabrication processes developed at New Mexico Technology Research Collaborative (NMTRC) member institutions. In particular, we focused on developing novel ruthenium oxide nanomaterials and placed them into carbon supports to significantly increase the energy density of the supercapacitor. These improvements were expected to reduce maintenance costs and expand the utility of the TPL, Inc.'s device, enabling New Mexico to become the leader in the growing global wireless power supply market. By dominating this niche, new customers were expected to be attracted to TPL, Inc. yielding new technical opportunities and increased job opportunities for New Mexico.

25 ENERGY STORAGE↗

Electroanalytical Investigation of the Electrode–Electrolyte Interface of Quaternary Ammonium Ionic Liquids: Impact of Alkyl Chain Length and Ether Functionality

The influence of ionic associations and potential-dependent interactions on the electrode–electrolyte interfacial structure of ionic liquids (ILs) is studied by electrochemical impedance spectroscopy (EIS) and surface-enhanced Raman spectroscopy (SERS) for a variety of asymmetric quaternary ammonium ILs. Specifically, the impact of cation alkyl chain length (C = 4, 8 and 16) and ether functionality on the interfacial structuring of ILs at the glassy carbon electrode surface is examined. Ammonium cations with alkyl chain length of 8 and 16 carbons are found to stabilize the formation of the bis(trifluorosulfonyl)imide, [TFSI], anion dense Stern layer at positive electrode potentials leading to larger capacitances. The longer alkyl chain of the cation is believed to screen the ion–ion repulsion among the anions by intruding into the interfacial anion layer. SERS suggests the presence of carbon-containing rings at the interface at both positive and negative electrode potentials, which can be explained by the buckling of the long alkyl chains. Inclusion of an ether functionality allowed for more symmetry in the camel-shaped potential-dependent differential capacitance curves, suggesting similar excess ion density at both positive and negative potentials. This work contributes to understanding and predicting the interfacial electrode capacitance in ILs by understanding the balance of ionic interactions and the associated repulsions at electrode–electrolyte interfaces that are pertinent to electrochemical energy storage, electrocatalysis, and electrochemical sensors.

25 ENERGY STORAGE↗

Analysis of Fluid Gauge Sensor for Zero or Microgravity Conditions using Finite Element Method

In this paper the Finite Element Method (FEM) is presented for mass/volume gauging of a fluid in a tank subjected to zero or microgravity conditions. In this approach first mutual capacitances between electrodes embedded inside the tank are measured. Assuming the medium properties the mutual capacitances are also estimated using FEM approach. Using proper non-linear optimization the assumed properties are updated by minimizing the mean square error between estimated and measured capacitances values. Numerical results are presented to validate the present approach.

Deshpande, Manohar D.↗

Carrier behavior in special multilayer device composed of different transition metal oxide-based intermediate connectors

The impact of illumination on the connection part of the tandem organic light-emitting diodes was studied by using a special organic multilayer sample consisted of two organic active layers coupled with different transition metal oxide (TMO)-based intermediate connectors (ICs). Through measuring the current density-voltage characteristic, interfacial electronic structures, and capacitance-voltage characteristic, we observe an unsymmetrical phenomenon in current density-voltage and capacitance-voltage curves of Mg:Alq{sub 3}/MoO{sub 3} and MoO{sub 3} composed devices, which was induced by the charge spouting zone near the ICs region and the recombination state in the MoO{sub 3} layer. Moreover, Mg:Alq{sub 3}/MoO{sub 3} composed device displays a photovoltaic effect and the V{sub oc} shifts to forward bias under illumination. Our results demonstrate that the TMO-based IC structure coupled with photovoltaic effect can be a good approach for the study of photodetector, light sensor, and so on.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SOI CMOS Imager with Suppression of Cross-Talk

A monolithic silicon-on-insulator (SOI) complementary metal oxide/semiconductor (CMOS) image-detecting integrated circuit of the active-pixel-sensor type, now undergoing development, is designed to operate at visible and near-infrared wavelengths and to offer a combination of high quantum efficiency and low diffusion and capacitive cross-talk among pixels. The imager is designed to be especially suitable for astronomical and astrophysical applications. The imager design could also readily be adapted to general scientific, biological, medical, and spectroscopic applications. One of the conditions needed to ensure both high quantum efficiency and low diffusion cross-talk is a relatively high reverse bias potential (between about 20 and about 50 V) on the photodiode in each pixel. Heretofore, a major obstacle to realization of this condition in a monolithic integrated circuit has been posed by the fact that the required high reverse bias on the photodiode is incompatible with metal oxide/semiconductor field-effect transistors (MOSFETs) in the CMOS pixel readout circuitry. In the imager now being developed, the SOI structure is utilized to overcome this obstacle: The handle wafer is retained and the photodiode is formed in the handle wafer. The MOSFETs are formed on the SOI layer, which is separated from the handle wafer by a buried oxide layer. The electrical isolation provided by the buried oxide layer makes it possible to bias the MOSFETs at CMOS-compatible potentials (between 0 and 3 V), while biasing the photodiode at the required higher potential, and enables independent optimization of the sensory and readout portions of the imager.

Pain, Bedabrata↗

A compact and miniaturized high resolution capacitance dilatometer for measuring thermal expansion and magnetostriction

We describe the design, construction, calibration, and two different applications of a miniature capacitance dilatometer. The device is suitable for thermal expansion and magnetostriction measurements from 300 K down to about 25 mK, with a resolution of 0.02 A at low temperatures. The main body of the dilatometer is fabricated from a single block of a Be-Cu alloy by electrical discharge milling. This creates an extremely compact high-resolution measuring cell. We have successfully tested and operated dilatometers of this new type with the commonly used physical property measurement system by quantum design, as well as with several other cryogenic refrigeration systems down to 25 mK and in magnetic fields up to 20 T. Here, the capacitance is measured with a commercially available capacitance bridge. Using a piezoelectric rotator from Attocube Systems, the cell can be rotated at T= 25 mK inside of an inner vacuum chamber of 40 mm diameter. The miniaturized design for the one-axis rotation setup allows a rotation of 360 Degree-Sign .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A single electron transistor charge sensor in strong rf fields

We measure the charge sensitivity, S e , of a single electron transistor (SET) in the presence of strong (V rf ~ e/C g ) spurious radio frequency (rf) signals at frequencies up to 50 MHz, where C g is the gate capacitance. Although S e appears to degrade when exposed to V rf , we find that broadening of conduction peaks is largely due to the measurement technique and show that S e is maintained even with strong V rf present. We show cancellation of a known V rf signal at 1 MHz, demonstrating that a stable bias point in the presence of rf signals is possible.

47 OTHER INSTRUMENTATION↗

Propellant Mass Gauging in Microgravity with Electrical Capacitance Tomography

Advancements in microgravity propellant mass gauging will result in improvements to many areas of propellant management, which influences space vehicle performance and mission assurance. Propellant mass gauging technologies designed to work in an accelerated environment, where the propellant remains settled at one end of the propellant tank, do not always work well in a microgravity environment because the propellant is not necessarily settled. While some microgravity mass gauging technologies exist at various stages of development, most of them have major disadvantages. Electrical Capacitance Tomography (ECT) is a sensing technology that is able to reconstruct the liquid distribution inside of a tank, which can then be integrated to obtain mass. While ECT mass gauging will theoretically work during all phases of flight, it had not yet been tested in microgravity. The NASA Kennedy Space Center Launch Services Program, with support from the Flight Opportunities Program, successfully tested an ECT liquid mass gauging system experiment on a parabolic flight aircraft in May 2022. Basics of ECT measurement theory, details of the experiment setup, data processing, ground test results, and the flight test result will be discussed. The results suggest that ECT sensor systems will be useful as a propellant mass gauging technology in both accelerated and microgravity environments.

electrical capacitance tomography↗

Thermal and radiation response of 4H–SiC Schottky diodes with direct-write electrical contacts

In this work, a high-sensitivity 4H–SiC temperature sensor and an alpha detector have been fabricated using additively printed metal contacts. The surface morphology and electrical conductivity of the printed electrodes were established prior to Schottky diode development. 4H–SiC Schottky diodes with direct-write printed silver contacts on the 5 μ m-thick epilayer on 4H–SiC were characterized electrically in terms of the forward and reverse current–voltage and high-frequency capacitance–voltage characteristics. Furthermore, the turn-on voltage of the Schottky diodes, as established from the forward current–voltage characteristics measured up to a temperature of 400 °C, showed a linear temperature dependence. Schottky diodes with direct-write printed Ag electrodes were able to measure alpha particles emitted from Americium-241. The high temperature and radiation response of the Schottky diodes show their suitability for multi-modal sensor fusion on the 4H–SiC platform for harsh environment applications.

42 ENGINEERING↗

Gamma Radiation Monitoring Through Thin Film of ClAlPc Doped With TiO{sub 2}

Chloroaluminum phthalocyanine (ClAlPc) synthesized by adopting focused microwave synthesis approach was doped with nanocrystalline TiO{sub 2} (5% by weight) and developed into the thin film sandwiched device having ITO/ClAlPc:TiO{sub 2}/Ag Schottky configuration by spin coating technique covering 1 cm{sup 2} as an active area. The so fabricated device having initial dark current of the order of 0.2 5 m A was exposed to variable dose of gamma radiation ranging from lcGy to 10 Gy at a dose rate of 1 Gy/hour. The experimental observation reveals the generation of localized traps leading to structural disorder within the solid material. Doping with TiO{sub 2} enhances the surface area of the film which in tern improves sensitivity of device to wider dose rage. Exposure of the device to variable dose of gamma radiation imparts decrease in forward bias current and capacitance characteristics with increase in radiation dose. Also, absorbance characteristics of the Al Pc: TiO{sub 2} was analyzed before and after exposure to radiation which reveals that absorbance decreases with radiation dose leading to decrease in optical band gap.

36 MATERIALS SCIENCE↗

Electronic and Interfacial Properties of PD/6H-SiC Schottky Diode Gas Sensors

Pd/SiC Schottky diodes detect hydrogen and hydrocarbons with high sensitivity. Variation of the diode temperature from 100 C to 200 C shows that the diode sensitivity to propylene is temperature dependent. Long-term heat treating at 425 C up to 140 hours is carried out to determine the effect of extended heat treating on the diode properties and gas sensitivity. The heat treating significantly affects the diode's capacitive characteristics, but the diode's current carrying characteristics are much more stable with a large response to hydrogen. Scanning Electron Microscopy and X-ray Spectrometry studies of the Pd surface after the heating show cluster formation and background regions with grain structure observed in both regions. The Pd and Si concentrations vary between grains. Auger Electron Spectroscopy depth profiles revealed that the heat treating promoted interdiffusion and reaction between the Pd and SiC dw broadened the interface region. This work shows that Pd/SiC Schottky diodes have significant potential as high temperature gas sensors, but stabilization of the structure is necessary to insure their repeatability in long-term, high temperature applications.

Chen, Liang-Yu↗

Preliminary Results from Propellant Mass Gauging with Electrical Capacitance Tomography

Propellants mass gauging technologies designed to work in an accelerated environment, where the propellant remains settled at one end of the propellant tank, do not work well in a microgravity environment because the propellant is not necessarily settled. While some microgravity mass gauging technologies exist at various TRLs, most of them have major disadvantages. Improvements in microgravity propellant mass gauging will result in improvements to many areas of propellant management, which influences performance and mission assurance. Electrical Capacitance Tomography (ECT) is a sensing technology that is able to reconstruct the liquid distribution inside of a tank, which can then be integrated to obtain mass. ECT mass gauging recently achieved high accuracy in laboratory testing, <0.1% liquid volume measurement error, even during sloshing. While ECT mass gauging will theoretically work during all phases of flight, it had not yet been tested in microgravity. The NASA KSC Launch Services Program, with support from the Flight Opportunities Program, successfully flew an ECT liquid mass gauging system experiment on a Zero-G parabolic flight aircraft. Basics of ECT measurement theory, details of the experiment setup and flights, and preliminary results will be discussed. The preliminary results suggest that, even in the current prototype generation, ECT sensor systems will be useful as a propellant mass gauging technology in both an accelerated and microgravity environment.

mass gauging↗