Search NASA⌕ Search

SEARCH · Search NASA

Results for “changes made 4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Incorporation of trace elements in Portland cement clinker: Thresholds limits for Cu, Ni, Sn or Zn

This paper aims at defining precisely, the threshold limits for several trace elements (Cu, Ni, Sn or Zn) which correspond to the maximum amount that could be incorporated into a standard clinker whilst reaching the limit of solid solution of its four major phases (C{sub 3}S, C{sub 2}S, C{sub 3}A and C{sub 4}AF). These threshold limits were investigated through laboratory synthesised clinkers that were mainly studied by X-ray Diffraction and Scanning Electron Microscopy. The reference clinker was close to a typical Portland clinker (65% C{sub 3}S, 18% C{sub 2}S, 8% C{sub 3}A and 8% C{sub 4}AF). The threshold limits for Cu, Ni, Zn and Sn are quite high with respect to the current contents in clinker and were respectively equal to 0.35, 0.5, 0.7 and 1 wt.%. It appeared that beyond the defined threshold limits, trace elements had different behaviours. Ni was associated with Mg as a magnesium nickel oxide (MgNiO{sub 2}) and Sn reacted with lime to form a calcium stannate (Ca{sub 2}SnO{sub 4}). Cu changed the crystallisation process and affected therefore the formation of C{sub 3}S. Indeed a high content of Cu in clinker led to the decomposition of C{sub 3}S into C{sub 2}S and of free lime. Zn, in turn, affected the formation of C{sub 3}A. Ca{sub 6}Zn{sub 3}Al{sub 4}O{sub 15} was formed whilst a tremendous reduction of C{sub 3}A content was identified. The reactivity of cements made with the clinkers at the threshold limits was followed by calorimetry and compressive strength measurements on cement paste. The results revealed that the doped cements were at least as reactive as the reference cement.

36 MATERIALS SCIENCE↗

Depth-resolved carbon dioxide and methane concentrations in 522 lakes, ponds, and reservoirs worldwide

Lakes, ponds, and reservoirs (hereafter: “lakes”) are important sources of the greenhouse gases carbon dioxide (CO 2 ) and methane (CH 4 ). Emissions of CO 2 and CH 4 from lakes are regulated in part by in-lake processes, including the production and storage of gases in the lower parts of the water column (bottom waters). However, while substantial efforts have been made to improve estimates of greenhouse gas emissions from lakes, limited data on gas concentrations along depth profiles have prevented the incorporation of bottom-water processes in global emission estimates. Here, we present GHG-depths: the largest existing dataset of depth-profile CO 2 and CH 4 measurements worldwide, including 522 lakes across 38 countries and all seven continents. These data include contributions from 45 research teams and 56 published studies, totaling 2558 discrete sampling events. As global change continues to alter biogeochemical cycling in lakes, these data can help improve mechanistic models to better predict greenhouse gas production and emission from lakes worldwide.

Rabaey, Joseph S. [University of Minnesota, Duluth↗

Final Report: Demographic Tools for Climate Change and Environmental Assessments

This report summarizes work over the course of a three-year project (2012-2015, with one year no-cost extension to 2016). The full proposal detailed six tasks: Task 1: Population projection model Task 2: Household model Task 3: Spatial population model Task 4: Integrated model development Task 5: Population projections for Shared Socio-economic Pathways (SSPs) Task 6: Population exposure to climate extremes We report on all six tasks, provide details on papers that have appeared or been submitted as a result of this project, and list selected key presentations that have been made within the university community and at professional meetings.

54 ENVIRONMENTAL SCIENCES↗

Laboratory Astrophysics using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

When we last reported, our new microcalorimeter system was being prepared for delivery and permanent installation at the NIST EBIT. This occurred in June 2003 and check-out with the internal calibration source and EBIT plasma x-rays took place over the next several months during which time we modified several component parts to improve the performance. These changes included: 1) A redesign of the x-ray calibration source from a direct electron impact source to one that irradiates the microcalorimeter with fluorescent x-rays. The resulting calibration lines are free of bremsstrahlung background; 2) The microcalorimeter electronic circuit has been significantly improved to ensure long-term stability for the lengthy upcoming runs of the EBIT. Both the preamplifier feedback resistors were changed and the first stage of the preamplifier redesigned. Several photos of the new system are shown in slides 3 and 4. This microcalorimeter spectrometer only requires helium refills every three days (as opposed to every 24 hours in our earlier system) and it will hold a temperature of 65 mK for up to 48 hours (as opposed to 8 hours). Consequently, the efficiency of data acquisition will improve dramatically. The first x-ray spectra of the new calibration source made with the 4-element detector array is shown. An example of the temperature control capabilities of the ADR for a 23 hour interval is shown. The horizontal line shows the temperature stability (about +/- 3 micro kelvin). There are a few short-lived heating excursions caused by technical staff working on the EBIT machine simultaneously. During actual experimental runs these are absent. This temporal profile was interrupted to test additional components of the system; otherwise, the temperature controlling would have continued for another 24 hours.

Silver, Eric↗

Self-diagnosis of model suitability for continuous measurements of stream-dissolved organic carbon derived from in situ UV–visible spectroscopy

Application of high-frequency monitoring of dissolved organic carbon (DOC) is difficult in instances where training datasets are challenging to develop (e.g., remote locations) and the relationship between optical features and DOC concentration changes due to environmental or landscape shifts (e.g., climate or land-use change). We developed and compared three partial least squares (PLS) models using in situ water level measurements, conductivity, and UV–Vis spectral attenuation to predict DOC. Two site-specific models were developed using data from a hillslope-dominated forest or a low-relief wetland-pond-dominated stream catchment. The third model, using data from both sites, exhibited the best performance (DOC range = 4–15.5 mg C L −1 , mean = 8.38 mg C L −1 , training RMSE = 0.34 mg C L −1 , internal validation RMSE = 0.50 mg C L −1 , external validation RMSE = 2.43 mg C L −1 ). We further demonstrate using PLS model statistics to monitor performance and elucidate when and how models should be updated. These statistics, Hotelling's T 2 and squared prediction errors, are useful consistency checks for the predictions made and detect underlying inconsistencies that, if undetected, can reduce the robustness of DOC prediction. For example, via the T 2 statistic, we identified the summer–autumn transition as a period when DOC composition differed from what was represented in the training dataset. We also determined that elevated SUVA 254 values contributed to the overall bias observed in predictions made during the subsequent year as part of the external validation. This enabled the application of a bias correction that reduced the RMSE from 2.43 to 0.89 mg C L −1 . The method presented here could be applied to future monitoring programs enabling model updates to monitor DOC fluxes accurately from optical datasets (e.g., attenuance or fluorescence) in the face of developing datasets in remote locations or environmental change. In conclusion, implementation of this approach may also identify possible regime shifts or landscape and hydrologic change associated with climate and other environmental changes relevant to terrestrial to aquatic fluxes.

UV-VIS spectroscopy↗

CCD photometry of 2060 Chiron, 1991 January

Observations of 2060 Chiron was performed on 7 to 8 Jan. 1991 with the Mt. Palomar 1.52 m telescope in the Gunn-R passband. On-chip field stars were used to perform differential reductions. The repeatability of the 5.9 hour light curve was excellent, both within a night and from night to night. No evidence for short-term secular variations similar to those seen last year by both Luu and Jewitt (1990) and Buratti and Dunbar (1991) is seen in the new light curve. Chiron's rotational light curve appears strikingly similar to that obtained a year earlier by Luu and Jewitt (1990), both in amplitude and shape. Both light curves show strongly correlated changes over a timescale of perhaps 15 minutes. These same features were marginally visible in the 1986 light curve. Such behavior is believed to be evidence that Chiron may be more aspherical than the 4 percent intensity variation might otherwise indicate, and favors a viewing geometry where the subearth latitude is rather low. Chiron was much fainter in 1985, when a partial light curve was obtained by Marcialis. Due to the lower sampling rate of these early data, no conclusions can be made regarding the high-frequency light curve structure back then. All three of these light curves differ significantly from that obtained by Buratti and Dunbar (1991), one week before the observations of Luu and Jewitt. The Chiron field was calibrated using Landolt standards on Ut 15 Mar. 1991. A mean R-magnitude of 15.6 + or - 0.1 was found. Variability of 2060 Chiron was demonstrated over timescales of minutes, hours, and years. An intense campaign was urged to monitor the photometric behavior of Chiron throughout the 1990s.

Buratti, B. J.↗

Is the Use of Fullerene in Photodynamic Therapy Effective for Atherosclerosis?

The purpose of this study was to evaluate Fullerene as a therapeutic photosensitizer in the treatment of atherosclerosis. An atherosclerotic experimental rabbit model was prepared by causing intimal injury to bilateral external iliac arteries using balloon expansion. In four atherosclerotic rabbits and one normal rabbit, polyethylene glycol-modified Fullerene (Fullerene-PEG) was infused into the left external iliac artery and illuminated by light emitting diode (LED), while the right external iliac artery was only illuminated by LED. Two weeks later, the histological findings for each iliac artery were evaluated quantitatively and comparisons were made among atherosclerotic Fullerene+LED artery (n = 4), atherosclerotic light artery (n = 4), normal Fullerene+LED artery (n = 1), and normal light artery (n = 1). An additional two atherosclerotic rabbits were studied by fluorescence microscopy, after Fullerene-PEG-Cy5 complex infusion into the left external iliac artery, for evaluation of Fullerene-PEG incorporated within the atherosclerotic lesions. The degree of atherosclerosis in the atherosclerotic Fullerene+LED artery was significantly (p < 0.05) more severe than that in the atherosclerotic LED artery. No pathological change was observed in normal Fullerene+LED and LED arteries. In addition, strong accumulation of Fullerene-PEG-Cy5 complex within the plaque of the left iliac artery of the two rabbits was demonstrated, in contrast to no accumulation in the right iliac artery. We conclude that infusion of a high concentration of Fullerene-PEG followed by photo-illumination resulted not in a suppression of atherosclerosis but in a progression of atherosclerosis in experimental rabbit models. However, this intervention showed no adverse effects on the normal iliac artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance Evaluation of Mineral Additive-free Perfluoropolymer Nanocomposite O-ring in Simulated Geothermal Environments of 300C

The objective of this research was to evaluate the performance of O-rings made with a mineral additive-free perfluoropolymer (FFKM) nanocomposite in mitigating irremovable silica- and silicate-scaling, inhibiting oxidative reactions, minimizing the changes in mechanical behaviors, and maintaining the integrity of O-rings after their exposure to the five different simulated geothermal environments at 300°C: 1) 0.01N sodium metasilicate (SMS)-laden non-aerated (NR2R R(g) Rsaturated) steam-cooling cycles; 2) 0.01N SMS-laden aerated steam-cooling cycles; 3) water-based drilling fluid; 4) COR2R-rich geo-brine fluid; and, 5) heat-cool water quenching cycles (thermal shock). All the thermochemical environments 1 to 4 were carried out under a pressure of 8.3 MPs.

15 GEOTHERMAL ENERGY↗

Noise reduction studies for the Cessna model 337 (0-2) airplane

A study was undertaken to determine the noise reduction potential of the 0-2 airplane in order to reduce its aural detection distance. Static and flyover noise measurements were made to document the noise signature of the unmodified airplane. The results show that significant reductions in aural detection distance can be achieved by the combination of propeller geometry changes and the addition of engine exhaust mufflers. The best results were estimated for the aircraft equipped with a six-blade propeller operating at 3/4 engine speed in combination with a 3.49 cubic foot exhaust muffler installed on each engine. Detection distance for the modified aircraft is estimated to be reduced from about 4-1/4 miles to about 1-1/2 miles when the aircraft is operating at an altitude of 1,000 ft over grassy terrain. Reducing the altitude to 300 ft over a leafy jungle ground cover should reduce the aural detection distance to 0.9 miles. Reduced aural detection distances were also indicated for a modification utilizing a direct-drive six-blade propeller of reduced radius along with smaller exhaust mufflers.

Hilton, D. A.↗

A method to dramatically improve subcarrier tracking

A method is presented for achieving a dramatic improvement in phase tracking of square wave subcarriers or other square waves. The method is to set the amplitude of the phase quadrature reference signal to zero except near the zero crossings of the input signal. Without changing the loop bandwidth, the variance of the phase error can be reduced to approximately W sigma(sub 0)(2), were sigma (sub 0)(2) is the phase error variance without windowing, and W is the fraction of cycle in which the reference signal has a nonzero value. Simulation results confirm the analysis and establish minimum W versus signal-to-noise ratio. Typically, the window can be made so narrow as to achieve a phase error variance of 1.5 sigma(sub 0)(4).

Hurd, W. J.↗

A method to dramatically improve subcarrier tracking

A method is presented for achieving a dramatic improvement in phase tracking of square wave subcarriers or other square waves. The method is to set the amplitude of the phase quadrature reference signal to zero except near the zero crossings of the input signal. Without changing the loop bandwidth, the variance of the phase error can be reduced to approximately W sigma(sub 0)(2), where sigma (sub 0)(2) is the phase error variance without windowing, and W is the fraction of cycle in which the reference signal has a nonzero value. Simulation results confirm the analysis and establish minimum W versus signal-to-noise ratio. Typically, the window can be made so narrow as to achieve a phase error variance of 1.5 sigma(sub 0)(4).

Hurd, William J.↗

Spatial Orientation and Balance Control Changes Induced by Altered Gravito-Inertial Force Vectors

Seventeen healthy and eight vestibular deficient subjects were exposed to an interaural centripetal acceleration of 1 G (resultant 45 deg roll tilt of 1.4 G) on a 0.8 meter radius centrifuge for a period of 90 minutes in the dark. The subjects sat with head fixed upright, except every 4 of 10 minutes when instructed to rotate their head so that their nose and eyes pointed towards a visual point switched on every 3 to 5 seconds at random places (within +/- 30 deg) in the Earth horizontal plane. Motion sickness caused some subjects to limit their head movements during significant portions of the 90 minute period, and led three normal subjects to stop the test earlier. Eye movements, including directed saccades for subjective Earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation using electro-oculography. Postural stability measurements were made before and within ten minutes after centrifugation. In normal subjects, postural sway and multisegment body kinematics were gathered during an eyes-closed head movement cadence (sway-referenced support platform), and in response to translational/rotational platform perturbations. A significant increase in postural sway, segmental motion amplitude and hip frequency was observed after centrifugation. This effect was short-lived, with a recovery time of several postural test trials. There were also asymmetries in the direction of post-centrifugation center of sway and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). To delineate the effect of the magnitude of the gravito-inertial vector versus its direction during the adaptive centrifugation period, we tilted eight normal subjects in the roll axis at a 45 deg angle in the dark for 90 minutes without rotational motion. Their postural responses did not change following the period of tilt. Based on verbal reports, normal subjects overestimated roll-tilt during 90 minutes of both tilt and centrifugation stimuli. Subjective estimates of head-horizontal, provided by directed saccades, revealed significant errors after approximately 30 minutes that tended to increase only in the group who underwent centrifugation. Immediately after centrifugation, subjects reported feeling tilted on average 10 degrees in the opposite direction, which was in agreement with the direction of their earth-directed saccades. In vestibular deficient (VD) subjects, postural sway was measured using a sway-referenced or earth-fixed support surface, and with or without a head movement sequence. 'Me protocol was selected for each patient during baseline testing, and corresponded to the most challenging condition in which the patient was able to maintain balance with eyes closed. Bilaterally VD subjects showed no postural decrement after centrifugation, while unilateral VD subjects had varying degrees of decrement. Unilateral VD subjects were tested twice; they underwent centrifugation both with right ear out and left ear out. Their post-centrifuation center of sway shifted at right angles depending on the centrifuge GIF orientation. Bilateral VD subjects bad shifts as well, but no consistent directional trend. VD subjects underestimated roll-tilt during centrifugation, These results suggest that orientation of the gravito-inertial vector and its magnitude arc both used by the central nervous system for calibration of multiple orientation systems. A change in the background gravito-inertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

Kaufman, Galen D.↗

The Open Provenance Model core specification (v1.1)

The Open Provenance Model is a model of provenance that is designed to meet the following requirements: (1) To allow provenance information to be ex- changed between systems, by means of a compatibility layer based on a shared provenance model. (2) To allow developers to build and share tools that operate on such a provenance model. (3) To deFIne provenance in a precise, technology- agnostic manner. (4) To support a digital representation of provenance for any “thing, whether produced by computer systems or not. (5) To allow multiple levels of description to coexist. (6) To deFIne a core set of rules that identify the valid inferences that can be made on provenance representation. This docu- ment contains the speciFIcation of the Open Provenance Model (v1.1) resulting from a commChallenge.

99 GENERAL AND MISCELLANEOUS↗

Waste Isolation Pilot Plant Environmental Monitoring Plan (Rev. 4)

U.S. Department of Energy (DOE) Order 450.1A, Environmental Protection Program, requires each DOE site to conduct environmental monitoring. Environmental monitoring at the Waste Isolation Pilot Plant (WIPP) is conducted in order to: (1) verify and support compliance with applicable federal, state, and local environmental laws, regulations, permits, and orders; (2) establish baselines and characterize trends in the physical, chemical, and biological condition of effluent and environmental media; (3) identify potential environmental problems and evaluate the need for remedial actions or measures to mitigate the problems; (4) detect, characterize, and report unplanned releases; (5) evaluate the effectiveness of effluent treatment and control, and pollution abatement programs; and (6)determine compliance with commitments made in environmental impact statements, environmental assessments, safety analysis reports, or other official DOE documents. This Environmental Monitoring Plan (EMP) explains the rationale and design criteria for the environmental monitoring program, extent and frequency of monitoring and measurements, procedures for laboratory analyses, quality assurance (QA) requirements, program implementation procedures, and direction for the preparation and disposition of reports. Changes to the environmental monitoring program may be necessary to allow the use of advanced technology and new data collection techniques. This EMP will document changes in the environmental monitoring program. Guidance for preparation of EMPs is contained in DOE/EH-0173T, Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Physical conditions in the solar corona during flarelike events

Soft X-ray images of the sun obtained with the S-056 telescope aboard Skylab are used to investigate physical conditions in the X-ray-emitting coronal plasma during flarelike events. Temporal and spatial variations in the density and temperature of the main X-ray source during a flare are determined along with the total radiative energy emitted by an observed loop system. Models for heat sources and energy balance are analyzed, radiative as well as conductive energy losses are computed, and an attempt is made to develop a self-consistent model of the observed X-ray event. It is concluded that: (1) loop tips constitute the source of the maximum X-ray flux; (2) conductive losses exceed radiative losses by several orders of magnitude; (3) energy (and possibly new matter) is added at loop tips; and (4) the most intense X-ray structures are located in areas where the magnetic field has a small radius of curvature and the axis of a loop sequence changes direction.

Vorpahl, J. A.↗

Aerodynamic performance of a 1.25-pressure-ratio axial-flow fan stage

Aerodynamic design parameters and overall and blade-element performances of a 1.25-pressure-ratio fan stage are reported. Detailed radial surveys were made over the stable operating flow range at rotative speeds from 70 to 120 percent of design speed. At design speed, the measured stage peak efficiency of 0.872 occurred at a weight flow of 34.92 kilograms per second and a pressure ratio of 1.242. Stage stall margin is about 20 percent based on the peak efficiency and stall conditions. The overall peak efficiency for the rotor was 0.911. The overall stage performance showed no significant change when the stators were positioned at 1, 2, or 4 chords downstream of the rotor.

Moore, R. D.↗

An experimental study of tone excited heated jets

The objective of this investigation was to obtain detailed experimental data on the effects of upstream acoustic excitation on the mixing of heated jets with the surrounding air. Based on the information gathered in the literature survey, a technical approach was developed to carry out a systematic set of mean flowfield measurements for a broad range of jet operating and acoustic excitation conditions. Most of the results were obtained at Mach numbers of 0.3 and 0.8 and total temperatures of up to 800 K. Some measurements were made also for the fully expanded supersonic jet of Mj = 1.15. The maximum level of excitation was Le equal to or less than 150 dB and a range of excitation frequencies up to fe = 4 kHz was used. The important results derived from this study can be summarized as follows: (1) the sensitivity of heated jets to upstream acoustic excitation varies strongly with the jet operating conditions, (2) the threshold excitation level increases with increasing jet temperature, and (3) the preferred Strouhal number does not change significantly with a change of the jet operating conditions.

Lepicovsky, J.↗

Nuclear fuel development based on UMo alloys under irradiation evaluation of LEU U{sub 3}Si{sub 2} - 4.8 gU/cm{sup 3} test fuel

Latest irradiation reports on UMo dispersion fuel demand different solutions in order to stabilize an undesirable interaction layer zone produced by chemical reactions with the standard Al matrix. Among the different solutions, this paper addresses the evaluation of the additions of Si to the Al matrix and/or small amount of tetravalent elements (Si, Zr and Ti) to the fuel. The results of out-of-pile swelling tests applied to dispersion mini plates made of these modified constituents and interaction tests of interdiffusion couples are discussed. These results shows that the volume changes are directly related with the uranium density. The unmodified UMo/Al system exhibited swelling levels almost three times higher than those achieved with U{sub 3}Si{sub 2}, however for the system UMo/AlSi mix, these undesired behavior was reduced to values equivalent or slightly lower than U{sub 3}Si{sub 2}. Finally, details and specifications of a LEU U{sub 3}Si{sub 2} 4,8 gU/cm{sup 3} test fuel element, fabricated for under irradiation evaluation and design validation purposes at the RECH-1 research reactor, are reported in this paper. The planned follow-up program and initial irradiation results showing an appropriate performance that allows reaching the expected {sup 235}U burn up level, slightly over 50%, are detailed and discussed in next pages. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗