Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherent diffraction imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

An assessment of the resolution limitation due to radiation-damage in X-ray diffraction microscopy

X-ray diffraction microscopy (XDM) is a new form of x-ray imaging that is being practiced at several third-generation synchrotron-radiation x-ray facilities. Nine years have elapsed since the technique was first introduced and it has made rapid progress in demonstrating high-resolution three-dimensional imaging and promises few-nm resolution with much larger samples than can be imaged in the transmission electron microscope. Both life- and materials-science applications of XDM are intended, and it is expected that the principal limitation to resolution will be radiation damage for life science and the coherent power of available x-ray sources for material science. In this paper we address the question of the role of radiation damage. Here, we use a statistical analysis based on the so-called "dose fractionation theorem" of Hegerl and Hoppe to calculate the dose needed to make an image of a single life-science sample by XDM with a given resolution. We find that for simply-shaped objects the needed dose scales with the inverse fourth power of the resolution and present experimental evidence to support this finding. To determine the maximum tolerable dose we have assembled a number of data taken from the literature plus some measurements of our own which cover ranges of resolution that are not well covered otherwise. The conclusion of this study is that, based on the natural contrast between protein and water and "Rose-criterion" image quality, one should be able to image a frozen-hydrated biological sample using XDM at a resolution of about 10 nm.

36 MATERIALS SCIENCE↗

Diffraction image formation in optical systems with polarization aberrations. II - Amplitude response matrices for rotationally symmetric systems

In the previous paper in this series (McGuire and Chipman, 1990), a formulation was established for the calculation and analysis of diffraction image quality in polarizing optical systems illuminated with partially polarized, partially coherent light. In the present paper, the effect of second- and fourth-order polarization aberrations on the image plane diffraction patterns are examined. The amplitude response matrix is calculated for optical systems with small numerical apertures. Numerical results are presented for optical systems with circular apertures for three of the aberration types.

Mcguire, James P., Jr.↗

Pseudomonoenergetic x-ray diffraction measurements using balanced filters for coherent-scatter computed tomography

Coherent-scatter computed tomography (CSCT) is a method of ''composition'' imaging based on measurements of diffraction patterns from tissues. Use of an x-ray tube degrades scatter pattern angular resolution due to the x-ray spectral width, making it difficult to uniquely identify some materials. The use of two transmission filters with similar atomic numbers (balanced ''Ross filters'') to generate pseudomonoenergetic scatter patterns is described as it applies to CSCT. An analysis of angular-blur mechanisms reveals that focal spot size and beam width are the most important factors determining Bragg-peak width when Er-Tm filters are used. A relative RMS spectral width of 1% can be achieved in the difference spectrum and a Bragg-peak RMS angular width of approximately 0.14 deg. (relative width of 3% at 5 deg. scatter angle) can be achieved with an effective energy of 58 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image processing system to analyze droplet distributions in sprays

An image processing system was developed which automatically analyzes the size distributions in fuel spray video images. Images are generated by using pulsed laser light to freeze droplet motion in the spray sample volume under study. This coherent illumination source produces images which contain droplet diffraction patterns representing the droplets degree of focus. The analysis is performed by extracting feature data describing droplet diffraction patterns in the images. This allows the system to select droplets from image anomalies and measure only those droplets considered in focus. Unique features of the system are the totally automated analysis and droplet feature measurement from the grayscale image. The feature extraction and image restoration algorithms used in the system are described. Preliminary performance data is also given for two experiments. One experiment gives a comparison between a synthesized distribution measured manually and automatically. The second experiment compares a real spray distribution measured using current methods against the automatic system.

Bertollini, Gary P.↗

Analysis of a Scheme for De-magnified Talbot Lithography

The authors describe a photolithographic scheme based on the replication of a periodic transparent mask in a photoresist utilizing the coherent self-imaging Talbot effect. A periodic two-dimensional diffractive structure (or Talbot mask) composed of unit tiles distributed in a square matrix was illuminated by a coherent extreme ultraviolet (EUV) beam from a table top EUV laser. The illumination beam was reflected in a spherical mirror and the Talbot mask was placed in the path of the convergent beam. At designed locations determined by the Talbot distance, reduced replicas of the mask were obtained and used to print the slightly de-magnified copies of the mask on the surface of a photoresist. Experimental results showing the de-magnification effect are in good agreement with the diffraction theory. The limits of the technique are discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Femtosecond Time-Delay X-Ray Holography

X-ray free-electron lasers (XFELs) will produce photon pulses with a unique and desirable combination of properties. Their short X-ray wavelengths allow penetration into materials and the ability to probe structure at and below the nanometer scale. Their ultra-short duration gives information about this structure at the fundamental time-scales of atoms and molecules. The extreme intensity of the pulses will allow this information to be acquired in a single shot, so that these studies can be carried out on non-repeatable processes or on weakly-scattering objects that will be modified by the pulse. A fourth property of XFEL pulses is their high transverse coherence, which brings the promise of decades of innovation in visible optics to the X-ray regime, such as holography, interferometry, and laser-based imaging. Making an effective use of XFEL pulses, however, will benefit from innovations that are new to both X-ray science and coherent optics. One such innovation is the new method of time-delay X-ray holography [1], recently demonstrated at the FLASH FEL at DESY in Hamburg, to measure the evolution of objects irradiated by intense pulses. One of the pressing questions about the high-resolution XFEL imaging and characterization of non-periodic or weakly-scattering objects is the effect of the intense FEL pulse on the object, during the interaction with that pulse. The method of single-particle diffraction imaging [2] requires a stream of reproducible particles (e.g. a protein complex or virus) inserted into the beam, whereby a coherent X-ray diffraction pattern is recorded. The pulse will completely destroy the object, but if the pulse is short enough the diffraction pattern will represent the undamaged object. This ultrafast flash imaging was demonstrated at the FLASH FEL using test objects that included microfabricated patterns in silicon nitride foils [3]. Those experiments showed that no damage occurred during the 30 fs duration pulse. However, in those experiments the imaging resolution was limited by the long 32 nm wavelength at which the facility was then operating. We wished to dramatically increase our sensitivity to the particles explosions, to be able to increase the understanding of the dynamics of particles and predict the imaging performance at XFELs such as the LCLS. This was done in two ways in a single experiment: by holographically measuring the time evolution of the particle at times after the pulse had pass through the object; and by making an interferometric measurement of the change in the optical path through the object. The experimental technique, time-delay holography, achieved a time resolution better than 3 fs, and a phase sensitivity of better than 3{sup o}, or a sensitivity of < 3 nm of the expansion of the particles.

59 BASIC BIOLOGICAL SCIENCES↗

SpeckleNN: a unified embedding for real-time speckle pattern classification in X-ray single-particle imaging with limited labeled examples

With X-ray free-electron lasers (XFELs), it is possible to determine the three-dimensional structure of noncrystalline nanoscale particles using X-ray single-particle imaging (SPI) techniques at room temperature. Classifying SPI scattering patterns, or `speckles', to extract single-hits that are needed for real-time vetoing and three-dimensional reconstruction poses a challenge for high-data-rate facilities like the European XFEL and LCLS-II-HE. Here, we introduce SpeckleNN, a unified embedding model for real-time speckle pattern classification with limited labeled examples that can scale linearly with dataset size. Trained with twin neural networks, SpeckleNN maps speckle patterns to a unified embedding vector space, where similarity is measured by Euclidean distance. We highlight its few-shot classification capability on new never-seen samples and its robust performance despite having only tens of labels per classification category even in the presence of substantial missing detector areas. Without the need for excessive manual labeling or even a full detector image, our classification method offers a great solution for real-time high-throughput SPI experiments.

47 OTHER INSTRUMENTATION↗

Comment on ''Perfect imaging with positive refraction in three dimensions''

Leonhardt and Philbin [Phys. Rev. A 81, 011804(R) (2010)] have recently constructed a mathematical proof that the Maxwell's fish-eye lens provides perfect imaging of electromagnetic waves without negative refraction. In this comment, we argue that the unlimited resolution is an artifact of having introduced an unphysical drain at the position of the geometrical image. The correct solution gives focusing consistent with the standard diffraction limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase retrieval of diffraction from highly strained crystals

An important application of phase retrieval methods is to invert coherent x-ray diffraction measurements to obtain real-space images of nanoscale crystals. The phase information is currently recovered from reciprocal-space amplitude measurements by the application of iterative projective algorithms that solve the nonlinear and nonconvex optimization problem. Various algorithms have been developed each of which apply constraints in real and reciprocal space on the reconstructed object. In general, these methods rely on experimental data that is oversampled above the Nyquist frequency. To date, support-based methods have worked well, but are less successful for highly strained structures, defined as those which contain (real-space) phase information outside the range of {+-}{pi}/2. As a direct result the acquired experimental data is, in general, inadvertently subsampled below the Nyquist frequency. In recent years, a new theory of 'compressive sensing' has emerged, which dictates that an appropriately subsampled (or compressed) signal can be recovered exactly through iterative reconstruction and various routes to minimizing the l{sub 1} norm or total variation in that signal. This has proven effective in solving several classes of convex optimization problems. Here we report on a 'density-modification' phase reconstruction algorithm that applies the principles of compressive sensing to solve the nonconvex phase retrieval problem for highly strained crystalline materials. The application of a nonlinear operator in real-space minimizes the l{sub 1} norm of the amplitude by a promotion-penalization (or 'propenal') operation that confines the density bandwidth. This was found to significantly aid in the reconstruction of highly strained nanocrystals. We show how this method is able to successfully reconstruct phase information that otherwise could not be recovered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Challenges and opportunities in attosecond and XFEL science

In 2009, the world’s first hard X-FEL brought a ten-billion-fold gain in X-ray peak brightness. This fuelled the avidly pursued, but still elusive, dream of single-shot imaging of non-crystalline samples with near-atomic resolution. The overarching concept of ‘diffract-before-destroy’ imaging is that a powerful burst of ultrafast X-rays can produce a coherent diffraction pattern of a nanoscale object — before the object explodes due to Coulomb repulsion caused by a massively parallel ionization of the atoms in the sample. A collection of snapshots of identical objects in random orientations then provide information from which a 3D structure can be retrieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SHARP: a distributed GPU-based ptychographic solver

Ever brighter light sources, fast parallel detectors and advances in phase retrieval methods have made ptychography a practical and popular imaging technique. Compared to previous techniques, ptychography provides superior robustness and resolution at the expense of more advanced and time-consuming data analysis. Therefore, by taking advantage of massively parallel architectures, high-throughput processing can expedite this analysis and provide microscopists with immediate feedback. These advances allow real-time imaging at wavelength-limited resolution, coupled with a large field of view. This article describes a set of algorithmic and computational methodologies used at the Advanced Light Source and US Department of Energy light sources. These are packaged as a CUDA-based software environment named SHARP, aimed at providing state-of-the-art high-throughput ptychography reconstructions for the coming era of diffraction-limited light sources.

47 OTHER INSTRUMENTATION↗

ANALYTICAL COMPUTATION OF THE LYOT CORONAGRAPH RESPONSE TO AN EXTENDED SOURCE

This paper gives analytical expressions of the intensity in a Lyot coronagraph when the object is a resolved uniform disk. Intensities are given inside the Lyot stop and in the final plane. The derivation relies on the decomposition of the impinging waves on Zernike functions which allows the computation of the expansion of the intensities on infinite series. The expression in the final plane assumes that the sizes of the Lyot stop and the pupil are the same. An analysis of the truncation error is provided. These expressions are validated by computer simulations which makes it possible to recover known results such as the so-called diffraction ring observed by solar astronomers inside the Lyot stop. These analytical results and simulations bring deeper insight into the understanding of a Lyot coronagraph, for example, the fact that although the geometrical image of the source is behind the mask, a ghost image of the source can still be observed in the final plane.

07 ISOTOPE AND RADIATION SOURCES↗

A novel inert crystal delivery medium for serial femtosecond crystallography

Serial femtosecond crystallography (SFX) has opened a new era in crystallography by permitting nearly damage-free, room-temperature structure determination of challenging proteins such as membrane proteins. In SFX, femtosecond X-ray free-electron laser pulses produce diffraction snapshots from nanocrystals and microcrystals delivered in a liquid jet, which leads to high protein consumption. A slow-moving stream of agarose has been developed as a new crystal delivery medium for SFX. It has low background scattering, is compatible with both soluble and membrane proteins, and can deliver the protein crystals at a wide range of temperatures down to 4°C. Using this crystal-laden agarose stream, the structure of a multi-subunit complex, phycocyanin, was solved to 2.5Å resolution using 300µg of microcrystals embedded into the agarose medium post-crystallization. The agarose delivery method reduces protein consumption by at least 100-fold and has the potential to be used for a diverse population of proteins, including membrane protein complexes.

Conrad, Chelsie E.↗

Analysis of XFEL serial diffraction data from individual crystalline fibrils

Serial diffraction data collected at the Linac Coherent Light Source from crystalline amyloid fibrils delivered in a liquid jet show that the fibrils are well oriented in the jet. At low fibril concentrations, diffraction patterns are recorded from single fibrils; these patterns are weak and contain only a few reflections. Methods are developed for determining the orientation of patterns in reciprocal space and merging them in three dimensions. This allows the individual structure amplitudes to be calculated, thus overcoming the limitations of orientation and cylindrical averaging in conventional fibre diffraction analysis. The advantages of this technique should allow structural studies of fibrous systems in biology that are inaccessible using existing techniques.

36 MATERIALS SCIENCE↗

Coherent optical determination of the leaf angle distribution of corn

A coherent optical technique for the diffraction analysis of an image is presented. Developments in radar remote sensing shows a need to understand plant geometry and its relationship to plant moisture, soil moisture, and the radar backscattering coefficient. A corn plant changes its leaf angle distribution, as a function of time, from a uniform distribution to one that is strongly vertical. It is shown that plant and soil moisture may have an effect on plant geometry.

Ulaby, F. T.↗

Stray Light Modeling of the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM)

This paper describes an integrated stray light model of each Science Instrument (SI) in the Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST) and the Optical Telescope Element Simulator (OSIM), the light source used to characterize the performance of ISIM in cryogenic-vacuum tests at the Goddard Space Flight Center (GSFC). We present three cases where this stray light model was integral to solving questions that arose during the testing campaign - 1) ghosting and coherent diffraction from hardware surfaces in the Near Infrared Imager and Slitless Spectrograph (NIRISS) GR700XD grism mode, 2) ghost spots in the Near Infrared Camera (NIRCam) GRISM modes, and 3) scattering from knife edges of the NIRCam focal plane array masks.

stray light modeling↗