Search NASA⌕ Search

SEARCH · Search NASA

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Observations of Comet 2P/Encke During the Fall 2013 Apparition

We will present preliminary results from our observational campaign of Comet 2P/Encke during its 2013 perihelion passage. At optical wavelengths Encke is an extremely dust poor comet that has in past perihelion passages emitted a gas jet in the form a sunward fan. We expect to characterize both the morphology and lightcurve of the comet. The low optical dust means that even near perihelion the nuclear signature can be obtained in lightcurve data taken with narrowband continuum filters which cut out the gas emission. The campaign will consist of both narrowband and broadband imaging as well as infrared spectroscopy. Imaging will be obtained from 8 nights on the KPNO 2.1m between Sept. 7 and 14 UT. Additionally, the Murillo Family Observatory, a 0.5m telescope on the CSUSB campus which is equipped with both broadband filters and a narrowband Hale-Bopp set of filters will be used to observe the comet every clear night the moon allows between late August and early October to obtain extensive lightcurve data. These data will overlap both the Kitt Peak observations and the infrared spectroscopy which will be obtained with the SpeX instrument at the IRTF on four nights between September 26 UT and October 2 UT.

Abell, Paul↗

High-performance RC bandpass filter is adapted to miniaturized construction

Miniaturized bandpass filter with RC networks is suitable for use in integrated circuits. The circuit consists of three stages of amplification with additional resistive and capacitive components to obtain the desired characteristics. The advantages of the active RC filter network are the reduction in size and weight and elimination of magnetic materials.

Source record↗

Kalman Filter for Mass Property and Thrust Identification (MMS)

The Magnetospheric Multiscale (MMS) mission consists of four identically instrumented, spin-stabilized observatories, elliptically orbiting the Earth in a tetrahedron formation. For the operational success of the mission, on-board systems must be able to deliver high-precision orbital adjustment maneuvers. On MMS, this is accomplished using feedback from on-board star sensors in tandem with accelerometers whose measurements are dynamically corrected for errors associated with a spinning platform. In order to determine the required corrections to the measured acceleration, precise estimates of attitude, rate, and mass-properties is necessary. To this end, both an on-board and ground-based Multiplicative Extended Kalman Filter (MEKF) were formulated and implemented in order to estimate the dynamic and quasi-static properties of the spacecraft.

Maneuver and Attitude Dynamics↗

Optimization of plasma parameters with magnetic filter field and pressure to maximize H{sup −} ion density in a negative hydrogen ion source

Transverse magnetic filter field as well as operating pressure is considered to be an important control knob to enhance negative hydrogen ion production via plasma parameter optimization in volume-produced negative hydrogen ion sources. Stronger filter field to reduce electron temperature sufficiently in the extraction region is favorable, but generally known to be limited by electron density drop near the extraction region. In this study, unexpected electron density increase instead of density drop is observed in front of the extraction region when the applied transverse filter field increases monotonically toward the extraction aperture. Measurements of plasma parameters with a movable Langmuir probe indicate that the increased electron density may be caused by low energy electron accumulation in the filter region decreasing perpendicular diffusion coefficients across the increasing filter field. Negative hydrogen ion populations are estimated from the measured profiles of electron temperatures and densities and confirmed to be consistent with laser photo-detachment measurements of the H{sup −} populations for various filter field strengths and pressures. Enhanced H{sup −} population near the extraction region due to the increased low energy electrons in the filter region may be utilized to increase negative hydrogen beam currents by moving the extraction position accordingly. This new finding can be used to design efficient H{sup −} sources with an optimal filtering system by maximizing high energy electron filtering while keeping low energy electrons available in the extraction region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A user oriented microcomputer facility for designing linear quadratic Gaussian feedback compensators

The paper describes a laboratory design facility for digital microprocessor implementation of Linear-Quadratic-Gaussian feedback compensators. Outputs from user interactive programs for solving infinite time horizon LQ regulator and Kalman filter problems are conditioned for implementation on a laboratory microcomputer system. The software consists of two parts: (1) an off-line high-level program for solving the LQ Ricatti equations and generating associated feedback and filter gains, and (2) a cross compiler/macro assembler which generates object code for the target microprocessor system. Application to the control of a two dimensional inverted pendulum and expanding the design/prototyping system to other target machine architectures are discussed.

Houpt, P. K.↗

Convective Weather Forecast Quality Metrics for Air Traffic Management Decision-Making

Since numerical weather prediction models are unable to accurately forecast the severity and the location of the storm cells several hours into the future when compared with observation data, there has been a growing interest in probabilistic description of convective weather. The classical approach for generating uncertainty bounds consists of integrating the state equations and covariance propagation equations forward in time. This step is readily recognized as the process update step of the Kalman Filter algorithm. The second well known method, known as the Monte Carlo method, consists of generating output samples by driving the forecast algorithm with input samples selected from distributions. The statistical properties of the distributions of the output samples are then used for defining the uncertainty bounds of the output variables. This method is computationally expensive for a complex model compared to the covariance propagation method. The main advantage of the Monte Carlo method is that a complex non-linear model can be easily handled. Recently, a few different methods for probabilistic forecasting have appeared in the literature. A method for computing probability of convection in a region using forecast data is described in Ref. 5. Probability at a grid location is computed as the fraction of grid points, within a box of specified dimensions around the grid location, with forecast convection precipitation exceeding a specified threshold. The main limitation of this method is that the results are dependent on the chosen dimensions of the box. The examples presented Ref. 5 show that this process is equivalent to low-pass filtering of the forecast data with a finite support spatial filter. References 6 and 7 describe the technique for computing percentage coverage within a 92 x 92 square-kilometer box and assigning the value to the center 4 x 4 square-kilometer box. This technique is same as that described in Ref. 5. Characterizing the forecast, following the process described in Refs. 5 through 7, in terms of percentage coverage or confidence level is notionally sound compared to characterizing in terms of probabilities because the probability of the forecast being correct can only be determined using actual observations. References 5 through 7 only use the forecast data and not the observations. The method for computing the probability of detection, false alarm ratio and several forecast quality metrics (Skill Scores) using both the forecast and observation data are given in Ref. 2. This paper extends the statistical verification method in Ref. 2 to determine co-occurrence probabilities. The method consists of computing the probability that a severe weather cell (grid location) is detected in the observation data in the neighborhood of the severe weather cell in the forecast data. Probabilities of occurrence at the grid location and in its neighborhood with higher severity, and with lower severity in the observation data compared to that in the forecast data are examined. The method proposed in Refs. 5 through 7 is used for computing the probability that a certain number of cells in the neighborhood of severe weather cells in the forecast data are seen as severe weather cells in the observation data. Finally, the probability of existence of gaps in the observation data in the neighborhood of severe weather cells in forecast data is computed. Gaps are defined as openings between severe weather cells through which an aircraft can safely fly to its intended destination. The rest of the paper is organized as follows. Section II summarizes the statistical verification method described in Ref. 2. The extension of this method for computing the co-occurrence probabilities in discussed in Section HI. Numerical examples using NCWF forecast data and NCWD observation data are presented in Section III to elucidate the characteristics of the co-occurrence probabilities. This section also discusses the procedure for computing throbabilities that the severity of convection in the observation data will be higher or lower in the neighborhood of grid locations compared to that indicated at the grid locations in the forecast data. The probability of coverage of neighborhood grid cells is also described via examples in this section. Section IV discusses the gap detection algorithm and presents a numerical example to illustrate the method. The locations of the detected gaps in the observation data are used along with the locations of convective weather cells in the forecast data to determine the probability of existence of gaps in the neighborhood of these cells. Finally, the paper is concluded in Section V.

Chatterji, Gano B.↗

Making Phase-Picking Neural Networks More Consistent and Interpretable

Improving the interpretability of phase-picking neural networks remains an important task to facilitate their deployment to routine, real-time seismic monitoring. The popular phase-picking neural networks published in the literature lack interpretability because their output prediction scores do not necessarily correspond with the reliability of phase picks and can even be highly inconsistent depending on how we window the waveform data. Here, we show that systematically shifting the waveforms during training and using an antialiasing filter within the neural network architecture can substantially improve the consistency of the output prediction scores and can even make them scale with the signal-to-noise ratios of the waveforms. We demonstrate the improvements by applying these approaches to a commonly used phase-picking neural network architecture and using waveform data from the 2019 Ridgecrest earthquake sequence.

58 GEOSCIENCES↗

Trace explosive residue detection of HMX and RDX in post-detonation dust from an open-air environment

Explosives are often used in industry, geology, mining, and other applications, but it is not always clear what remains after a detonation or the fate and transport of any residual material. The goal of this study was to determine to what extent intact molecules of high explosive (HE) compounds are detectable and quantifiable from post-detonation dust and particulates in a field experiment with varied topography. We focused on HMX (1,3,5,7-Tetranitro-1,3,5,7-tetrazocane), which is less studied in field detonation literature, as the primary explosive material and RDX (1,3,5-Trinitroperhydro-1,3,5-triazine) as the secondary material. The experiment was conducted at Site 300, Lawrence Livermore National Laboratory’s Experimental Test Site, in California, USA. Two 20.4 kg and one 40.8 kg above ground explosions (primarily comprised of LX-14, an HMX-based polymer-bonded high explosive) were detonated on an open-air firing area on separate days. The complex terrain of the firing area (e.g., buildings, berm, low-height obstacles) was advantageous to study HE deposition in relation to plume dynamics. Three types of samples were collected up to 100 m away from each shot: surface swipes of aluminum plates, surface swipes of fixed objects, and filters from air samples. We used atmospheric flow tube-mass spectrometry (AFT-MS) to quantify picogram levels of molecular residue of HE material in the post-detonation dust. An aliquot of sample extract in methanol (e.g., 1 µL of 0.5 mL) was placed onto a resistive material and then thermally desorbed into the AFT-MS. We successfully detected and quantified both HMX and RDX in many of the samples. Based on mass (pg) detected and solution dilution, we back-calculated the mass collected on the swipe or filter (ng per sample). The aerial distribution of molecular residue was consistent with the path of the plume, which was strongly determined by wind speed and direction at the time of each shot. The quantity of material detected appeared to correlate more with distance from the shot and the wind conditions than with shot size. This study demonstrates that the picogram detection levels of AFT-MS are well-suited for quantification of analytes (e.g., HMX and RDX) in environmental samples.

atmospheric flow tube-mass spectrometry (AFT-MS), ↗

Enzymatic Filter for Improved Separation of Output Signals in Enzyme Logic Systems towards 'Sense and Treat' Medicine

The major challenge for application of autonomous medical sensing systems is the noise produced by non-zero physiological concentrations of the sensed target. If the level of noise is high, then a real signal indicating abnormal changes in the physiological levels of the analytes might be hindered. Inevitably, this could lead to wrong diagnostics and treatment, and would have a negative impact on human health. Here, we report the realization of a filter system implemented to improve both the fidelity of sensing and accuracy of consequent drug release. A new filtering method was tested in the sensing system for the diagnosis of liver injury. This sensing system used the enzymes alanine transaminase (ALT) and aspartate transaminase (AST) as the inputs. Furthermore, the output of the sensing system was designed to trigger drug release, and therefore, the role of the filter in drug release was also investigated. The drug release system consists of beads with an iron - cross-linked alginate core coated with different numbers of layers of poly-L-lysine. Dissolution of the beads by the output signals of the sensing system in the presence and absence of the filter was monitored by release of encapsulated in the beads rhodamine - 6G dye mimicking release of a real drug. The obtained results offer a new view on the problem of noise reduction for systems intended to be part of sense and treat medical devices.

Mailloux, Shay↗

High-performance double-filter soft x-ray diagnostic for measurement of electron temperature structure and dynamics

A new soft x-ray (SXR) T{sub e} and tomography diagnostic has been developed for MST that can be used for simultaneous SXR spectrum measurement, tomographically reconstructed emissivity, and reconstructed and line-of-sight electron temperature. The diagnostic utilizes high-performance differential transimpedance amplifiers (gain 10{sup 5}-10{sup 9}) to provide fast time response (up to 125 kHz), allowing for the study of plasma structure dynamics. SXR double-foil T{sub e} measurements are consistent with Thomson scattering. SXR brightness through a variety of filter thicknesses has been combined with charge exchange recombination spectroscopy (CHERS) impurity density measurements to determine the plasma energy spectrum. Magnetic pickup from the fluctuating magnetic fields in the plasma (B(tilde sign){approx}20 gauss at 10-20 kHz) has been dramatically reduced by improving the detector and housing design, so that nanoampere diode currents are now measured without interference from the substantial fluctuating magnetic field incident on the plasma facing surface of the probe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

International Space Station (ISS) Bacterial Filter Elements (BFEs): Filter Efficiency and Pressure Testing of Returned Units

The air revitalization system aboard the International Space Station (ISS) provides the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation due to the microgravity environment in Low Earth Orbit (LEO). The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Adsorption (HEPA) media filters deployed at multiple locations in each U.S. Segment module; these filters are referred to as Bacterial Filter Elements, or BFEs. These filters see a replacement interval, as part of maintenance, of 2-5 years dependent on location in the ISS. In this work, we present particulate removal efficiency, pressure drop, and leak test results for a sample set of 8 BFEs returned from the ISS after filter replacement. The results can potentially be utilized by the ISS Program to ascertain whether the present replacement interval can be maintained or extended to balance the on-ground filter inventory with extension of the lifetime of ISS beyond 2024. These results can also provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

Filtration↗

Construction of Low Dissipative High Order Well-Balanced Filter Schemes for Non-Equilibrium Flows

The goal of this paper is to generalize the well-balanced approach for non-equilibrium flow studied by Wang et al. [26] to a class of low dissipative high order shock-capturing filter schemes and to explore more advantages of well-balanced schemes in reacting flows. The class of filter schemes developed by Yee et al. [30], Sjoegreen & Yee [24] and Yee & Sjoegreen [35] consist of two steps, a full time step of spatially high order non-dissipative base scheme and an adaptive nonlinear filter containing shock-capturing dissipation. A good property of the filter scheme is that the base scheme and the filter are stand alone modules in designing. Therefore, the idea of designing a well-balanced filter scheme is straightforward, i.e., choosing a well-balanced base scheme with a well-balanced filter (both with high order). A typical class of these schemes shown in this paper is the high order central difference schemes/predictor-corrector (PC) schemes with a high order well-balanced WENO filter. The new filter scheme with the well-balanced property will gather the features of both filter methods and well-balanced properties: it can preserve certain steady state solutions exactly; it is able to capture small perturbations, e.g., turbulence fluctuations; it adaptively controls numerical dissipation. Thus it shows high accuracy, efficiency and stability in shock/turbulence interactions. Numerical examples containing 1D and 2D smooth problems, 1D stationary contact discontinuity problem and 1D turbulence/shock interactions are included to verify the improved accuracy, in addition to the well-balanced behavior.

Wang, Wei↗

The effect of Argon ion irradiation on the thickness and structure of ultrathin amorphous carbon films

Carbon films synthesized by plasma-enhanced chemical vapor deposition (PECVD) and filtered cathodic vacuum arc (FCVA) exhibit a layered structure consisting of a bottom (interface) and a top (surface) layer rich in sp{sup 2} atomic carbon bonding and a middle (bulk) layer of much higher sp{sup 3} content. Because of significant differences in the composition, structure, and thickness of these layers, decreasing the film thickness may negatively affect its properties. In this study, transmission electron microscopy (TEM) and electron energy loss spectroscopy (EELS) were used to examine the effect of Ar{sup +} ion irradiation on the structure and thickness of ultrathin films of hydrogenated amorphous carbon (a-C:H) and hydrogen-free amorphous carbon (a-C) deposited by PECVD and FCVA, respectively. The TEM and EELS results show that 2-min ion irradiation decreases the film thickness without markedly changing the film structure and composition, whereas 4-min ion irradiation results in significant film thinning and a moderate decrease of the sp{sup 3} content of the bulk layer. This study demonstrates that Ar{sup +} ion irradiation is an effective post-deposition process for reducing the thickness and tuning the structure of ultrathin carbon films. This capability has direct implications in the synthesis of ultrathin protective carbon overcoats for extremely high-density magnetic recording applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical experiments on consistent horizontal and vertical resolution for atmospheric models and observing systems

Simple numerical experiments are performed in order to determine the effects of inconsistent combinations of horizontal and vertical resolution in both atmospheric models and observing systems. In both cases, we find that inconsistent spatial resolution is associated with enhanced noise generation. A rather fine horizontal resolution in a satellite-data observing system seems to be excessive when combined with the usually available relatively coarse vertical resolution. Using horizontal filters of different strengths, adjusted in such a way as to render the effective horizontal resolution more consistent with vertical resolution for the observing system, may result in improvement of the analysis accuracy. The increase of vertical resolution for a satellite data observing system with better vertically resolved data, the results are different in that little or no horizontal filtering is needed to make spatial resolution more consistent for the system. The obtained experimental estimates of consistent vertical and effective horizontal resolution are in a general agreement with consistent resolution estimates previously derived theoretically by the authors.

Fox-Rabinovitz, Michael S.↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multi‐Species Energy‐Banded Ions in the Ionosphere During the 21 January 2005 Magnetic Storm: Low‐Altitude Edge of the Warm Plasma Cloak

During the 21–22 January 2005 magnetic storm, the FAST satellite observed warm (< few keV) ions in discrete energy bands on the dayside at ∼3,000 km altitude for more than 6.5 hr. We suggest that the ionospheric energy-banded ions represent the low-altitude edge of the warm plasma cloak observed simultaneously by magnetospheric satellites. This is a clear example of the multi-species ion energy bands (10 eV to several keV) observed during strong magnetic storms by the FAST satellite, stretching from the diffuse auroral region to the plasmapause with lifetimes up to 12 hr. The close association of these energy-banded ions with magnetic storms, their broad latitudinal extent, and the presence of multiple ion species in the same energy band, rather than at the same velocity, indicate that this is a distinct phenomenon from other types of energy-banded ions. During the 21–22 January 2005 magnetic storm, the dayside ion energy band structures, centered at 10 eV (H + ), 40 eV (H + and He + ), and 160 eV (H + , He + , and O + ), were consistent with a “time-of-flight and velocity filter” formation process acting on a near-cusp, impulsive outflow of a <200 eV multi-species ion-source population, poleward and in the same hemisphere as FAST. Understanding the sources and dynamics of warm energy-banded ions and their linkage to the warm plasma cloak is important because during superstorms these ions are transported to L values as low as L ∼ 1.2 in the dawn sector, significantly altering the energetics of the mid-latitude ionosphere.

58 GEOSCIENCES↗

Spectrometer for cluster ion beam induced luminescence

A spectrometer to detect the ultra-weak luminescence originated by the collision of cluster ions on the surfaces of solid materials was constructed. This spectrometer consists of 11 photomultipliers with band-pass interference filters that can detect the luminescence within the wavelength ranging from 300 to 700 nm and of a photomultiplier without filter. The calibration of the detection system was performed using the photons emitted from a strontium aluminate fluorescent tape and from a high temperature tungsten filament. Preliminary measurements show the ability of this spectrometer to detect the cluster ion beam induced luminescence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design of a correlation electron cyclotron emission system on J-TEXT

To study the anomalous transport, a correlation electron cyclotron emission (CECE) was planned to be developed on J-TEXT for electron temperature fluctuation measurement. The spectral decorrelation method was employed for the CECE system. It was developed based on the previous 16-channel electron cyclotron emission system. They shared the optical transmission line and mixer. The CECE part consists of 4 channels. Two fixed frequency narrow band filters were used for two channels and two yttrium iron garnet (YIG) filters for the other two channels. To meet the measuring requirement, some tests have been taken for the YIG filters. The results show good performance of the filters. Gaussian optics is used to produce a good poloidal resolution. Wavenumbers resolved by the CECE diagnostic are k{sub θ} ≤ 1.5 rad/cm and k{sub r} ≤ 12 rad/cm. Some preliminary experiment results are also presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗