Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Factors controlling pore network development of thermally mature Early Palaeozoic mudstones from the Baltic Basin (N Poland)

Understanding the formation of pore space, especially in low porosity shales (as source rocks and as unconventional resources), is critical to the oil and gas industry, since pores control the space available for hydrocarbon and participate in hydrocarbon transport. We examined 87 Ordovician and Silurian mudstone samples collected from four wells located in the Pomeranian part of the Baltic Basin (northern Poland), one of the primary Polish targets for hydrocarbon exploration. These samples represent the Pelplin, the Paslek, the Jantar, the Prabuty, and the Sasino Formations, which still requires more detailed porosity studies. Our study aimed to identify factors controlling porosity development, by applying bulk techniques (organic petrology and TOC analyses, quantitative mineralogy, and porosimetry) as well as nano- to microscale techniques (thin section petrography, electron microscopy). The studied samples are mainly argillaceous mudstones. The results of porosimetry measurements, combined with image analysis, indicate that the pores of all studied rocks are dominated by micropores (pores < 2 nm in diameter), mesopores (2-50 nm in diameter) and small macropores. The SEM images showed three main pore types: a) voids related to clay mineral aggregates, b) pores inside organic matter particles, and c) pores between other mineral grains. In the Jantar and Sasino mudstones, the organic matter content and its thermal maturity control porosity. The occurrence of solid bitumen in the rocks from these formations reduces samples’ mesoporosity because of the pore-clogging effect. In contrast, in the Paslek and Prabuty Formations, there is low organic matter content and specific surface area and the volume of mesopores increase with clay minerals content. In the Pelplin mudstones, there are no prevailing factors controlling porosity. As a result, we suggest that a combination of SEM image analysis and dual liquid porosity (DLP) measurements is a powerful method to assess porosity available for petroleum flow in mudstones.

03 NATURAL GAS↗

SU-F-J-183: Interior Region-Of-Interest Tomography by Using Inverse Geometry System

Purpose: The inverse geometry computed tomography (IGCT) composed of multiple source and small size detector has several merits such as reduction of scatter effect and large volumetric imaging within one rotation without cone-beam artifact, compared to conventional cone-beam computed tomography (CBCT). By using this multi-source characteristics, we intend to present a selective and multiple interior region-of-interest (ROI) imaging method by using a designed source on-off sequence of IGCT. Methods: All of the IGCT sources are operated one by one sequentially, and each projection in the shape of narrow cone-beam covers its own partial volume of full field of view (FOV) determined from system geometry. Thus, through controlling multi source operation, limited irradiation within ROI is possible and selective radon space data for ROI imaging can be acquired without additional X-ray filtration. With this feature, we designed a source on-off sequence for multi ROI-IGCT imaging, and projections of ROI-IGCT were generated by using the on-off sequence. Multi ROI-IGCT images were reconstructed by using filtered back-projection algorithm. All these imaging process of our study has been performed by utilizing digital phantom and patient CT data. ROI-IGCT images of the phantom were compared to CBCT image and the phantom data for the image quality evaluation. Results: Image quality of ROI-IGCT was comparable to that of CBCT. However, the distal axial-plane from the FOV center, large cone-angle region, ROI-IGCT showed uniform image quality without significant cone-beam artifact contrary to CBCT. Conclusion: ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. Projection of ROI-IGCT is performed by selective irradiation, hence unnecessary imaging dose to non-interest region can be reduced. In this regard, it seems to be useful for diagnostic or image guidance purpose in radiotherapy such as low dose target localization and patient alignment. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗

High-precision chemical quantum sensing in flowing monodisperse microdroplets

A method is presented for high-precision chemical detection that integrates quantum sensing with droplet microfluidics. Using nanodiamonds (ND) with fluorescent nitrogen-vacancy (NV) centers as quantum sensors, rapidly flowing microdroplets containing analyte molecules are analyzed. A noise-suppressed mode of optically detected magnetic resonance is enabled by pairing controllable flow with microwave control of NV electronic spins, to detect analyte-induced signals of a few hundredths of a percent of the ND fluorescence. Using this method, paramagnetic ions in droplets are detected with low limit-of-detection using small analyte volumes, with exceptional measurement stability over >10 3 s. In addition, these droplets are used as microconfinement chambers by co-encapsulating ND quantum sensors with various analytes such as single cells, suggesting wide-ranging applications including single-cell metabolomics and real-time intracellular measurements from bioreactors. Important advances are enabled by this work, including portable chemical testing devices, amplification-free chemical assays, and chemical imaging tools for probing reactions within microenvironments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physics–Dynamics Coupling with Element-Based High-Order Galerkin Methods: Quasi-Equal-Area Physics Grid

Atmospheric modeling with element-based high-order Galerkin methods presents a unique challenge to the conventional physics–dynamics coupling paradigm, due to the highly irregular distribution of nodes within an element and the distinct numerical characteristics of the Galerkin method. The conventional coupling procedure is to evaluate the physical parameterizations ( physics) on the dynamical core grid. Evaluating the physics at the nodal points exacerbates numerical noise from the Galerkin method, enabling and amplifying local extrema at element boundaries. Grid imprinting may be substantially reduced through the introduction of an entirely separate, approximately isotropic finite-volume grid for evaluating the physics forcing. Integration of the spectral basis over the control volumes provides an area-average state to the physics, which is more representative of the state in the vicinity of the nodal points rather than the nodal point itself and is more consistent with the notion of a “large-scale state” required by conventional physics packages. This study documents the implementation of a quasi-equal-area physics grid into NCAR’s Community Atmosphere Model Spectral Element and is shown to be effective at mitigating grid imprinting in the solution. The physics grid is also appropriate for coupling to other components within the Community Earth System Model, since the coupler requires component fluxes to be defined on a finite-volume grid, and one can be certain that the fluxes on the physics grid are, indeed, volume averaged.

54 ENVIRONMENTAL SCIENCES↗

Higher harmonic rotor blade pitch control

Tests of a model 'Reverse Velocity Rotor' system at high advance ratios and with twice-per-revolution cyclic pitch control were made under joint Navy-NASA sponsorship in the NASA, Ames 12 ft. pressure tunnel. The results showed significant gains in rotor performance at all advance ratios by using twice-per-revolution control. Detailed design studies have been made of alternative methods of providing higher harmonic motion including four types of mechanical systems and an electro-hydraulic system. The relative advantages and disadvantages are evaluated on the basis of stiffness, weight, volume, reliability and maintainability.

Ewans, J. R.↗

A Pressure Based Multigrid Procedure for the Navier-Stokes Equations on Unstructured Grids

We present details and performance of a pressure based multigrid solution procedure for the Navier-Stokes equations discretized on triangular grids. The discretization uses a control volume methodology, with linear inter-nodal variation of the flow variables. The use of the multigrid technique provides rapid and grid-independent rates of convergence. Three model driven cavity flows are computed, and the performance of the method at several grid densities and Reynolds numbers is reported. Representative flow fields characterizing the viscous eddies are also presented.

Jyotsna, R.↗

ICESat 2/ATLAS Onboard Flight Science Receiver Algorithms: Purpose, Process, and Performance

The Advanced Topographic Laser Altimetry System (ATLAS) is the sole instrument on the Ice, Cloud, and land Elevation Satellite 2 (ICESat-2). Without some method of reducing the transmitted data, the volume of ATLAS telemetry would far exceed the normal X-band downlink capability or require many more ground station contacts. The ATLAS Onboard Flight Science Receiver Algorithms (hereinafter Receiver Algorithms or Algorithms) control the amount of science data that is telemetered from the instrument, limiting the data volume by distinguishing surface echoes from background noise, and allowing the instrument to telemeter data from only a small vertical region about the signal. This is accomplished through the transfer of the spacecraft's location and attitude to the instrument every second, use of an onboard Digital Elevation Model, implementation of signal processing techniques, and use of onboard relief and surface type reference maps. Extensive ground testing verified the performance of the Algorithms. On-orbit analysis shows that the Algorithms are working as expected from the ground testing; they are performing well and meeting the mission requirements.

Algoritms, Signal Processing, Optimization, Flight↗

Structures including a measurement coating and methods of forming the same

A structure includes a substrate and a coating applied over the substrate, the coating containing particles sized between 30 and 250 micrometers. A proportion of the particles to the carrier is between 40 and 70 by volume percentage. In response to excitation of the structure by a controllable excitation source, a first instrument monitors behavior of the particles to determine a first condition of the structure thereby. In response to an absence of excitation of the structure by the controllable excitation source, a second instrument monitors behavior of the particles to determine a second condition of the structure thereby.

Ely, George Ray↗

Vibrational Power Flow Analysis of Rods and Beams

A new method to model vibrational power flow and predict the resulting energy density levels in uniform rods and beams is investigated. This method models the flow of vibrational power in a manner analogous to the flow of thermal power in a heat conduction problem. The classical displacement solutions for harmonically excited, hysteretically damped rods and beams are used to derive expressions for the vibrational power flow and energy density in the rod and beam. Under certain conditions, the power flow in these two structural elements will be shown to be proportional to the energy density gradient. Using the relationship between power flow and energy density, an energy balance on differential control volumes in the rod and beam leads to a Poisson's equation which models the energy density distribution in the rod and beam. Coupling the energy density and power flow solutions for rods and beams is also discussed. It is shown that the resonant behavior of finite structures complicates the coupling of solutions, especially when the excitations are single frequency inputs. Two coupling formulations are discussed, the first based on the receptance method, and the second on the travelling wave approach used in Statistical Energy Analysis. The receptance method is the more computationally intensive but is capable of analyzing single frequency excitation cases. The traveling wave approach gives a good approximation of the frequency average of energy density and power flow in coupled systems, and thus, is an efficient technique for use with broadband frequency excitation.

Wohlever, James Christopher↗

SU-E-J-221: A Novel Expansion Method for MRI Based Target Delineation in Prostate Radiotherapy

Purpose: To compare a novel bladder/rectum carveout expansion method on MRI delineated prostate to standard CT and expansion based methods for maintaining prostate coverage while providing superior bladder and rectal sparing. Methods: Ten prostate cases were planned to include four trials: MRI vs CT delineated prostate/proximal seminal vesicles, and each image modality compared to both standard expansions (8mm 3D expansion and 5mm posterior, i.e. ∼8mm) and carveout method expansions (5mm 3D expansion, 4mm posterior for GTV-CTV excluding expansion into bladder/rectum followed by additional 5mm 3D expansion to PTV, i.e. ∼1cm). All trials were planned to total dose 7920 cGy via IMRT. Evaluation and comparison was made using the following criteria: QUANTEC constraints for bladder/rectum including analysis of low dose regions, changes in PTV volume, total control points, and maximum hot spot. Results: ∼8mm MRI expansion consistently produced the most optimal plan with lowest total control points and best bladder/rectum sparing. However, this scheme had the smallest prostate (average 22.9% reduction) and subsequent PTV volume, consistent with prior literature. ∼1cm MRI had an average PTV volume comparable to ∼8mm CT at 3.79% difference. Bladder QUANTEC constraints were on average less for the ∼1cm MRI as compared to the ∼8mm CT and observed as statistically significant with 2.64% reduction in V65. Rectal constraints appeared to follow the same trend. Case-by-case analysis showed variation in rectal V30 with MRI delineated prostate being most favorable regardless of expansion type. ∼1cm MRI and ∼8mm CT had comparable plan quality. Conclusion: MRI delineated prostate with standard expansions had the smallest PTV leading to margins that may be too tight. Bladder/rectum carveout expansion method on MRI delineated prostate was found to be superior to standard CT based methods in terms of bladder and rectal sparing while maintaining prostate coverage. Continued investigation is warranted for further validation.

60 APPLIED LIFE SCIENCES↗

Optimization-based, property-preserving finite element methods for scalar advection equations and their connection to Algebraic Flux Correction

In this paper, we continue our efforts to exploit optimization and control ideas as a common foundation for the development of property-preserving numerical methods. Here we focus on a class of scalar advection equations whose solutions have fixed mass in a given Eulerian region and constant bounds in any Lagrangian volume. Our approach separates discretization of the equations from the preservation of their solution properties by treating the latter as optimization constraints. This relieves the discretization process from having to comply with additional restrictions and makes stability and accuracy the sole considerations in its design. A property-preserving solution is then sought as a state that minimizes the distance to an optimally accurate but not property-preserving target solution computed by the scheme, subject to constraints enforcing discrete proxies of the desired properties. Furthermore, we consider two such formulations in which the optimization variables are given by the nodal solution values and suitably defined nodal fluxes, respectively. A key result of the paper reveals that a standard Algebraic Flux Correction (AFC) scheme is a modified version of the second formulation obtained by shrinking its feasible set to a hypercube. In conclusion, we present numerical studies illustrating the optimization-based formulations and comparing them with AFC

97 MATHEMATICS AND COMPUTING↗

SU-F-T-203: High Dose Definitive Proton Therapy with Integrated Boost to Hypoxic Subvolumes Determined by [18F]-Fluoromisonidazole (FMISO) PET/CT for Patients with Recurrent Chordomas Using Intensity Modulated Proton Therapy (IMPT)

Purpose: Recurrent chordomas are difficult to control locally. This dosimetric study investigates the feasibility of dose escalation to hypoxic regions, visualized on FMISO-PET, while respecting the dose constraints to the neighboring normal tissues/organs. We propose to deliver a higher dose to the areas of hypoxia (84.5Gy) using IMPT with the goal of improving local control. Methods: We currently have four patients with hypoxic subvolumes (HSV) greater than 10cc from the FMISO-PET image. The HSV was delineated based on the standardized uptake values of greater than 1.4 times of the muscle mean. Gross tumor volume (GTV) was delineated using planning CT with the assistance of MRI fusion. The dose scheme is 50.4Gy RBE to CTV in 1.8Gy fractions, followed by an integrated boost of 27.0Gy RBE to GTV in 1.8Gy fractions and 34.5Gy RBE to HSV in 2.3Gy fractions. IMPT integrated boost plans were optimized with multi-criteria optimization (MCO). Posterior-anterior beam angles were used for these plans. We also propose using two posterior oblique fields to boost HSV to spare the skin folding. A medium spot size with 8mm to 15 mm (σ) in air at isocenter with energies from 220 MeV down to 90 MeV was used. Aperture was used for the medium spot size. A small spot size of 2.5 mm to 4.5 mm (σ) in air at isocenter with energies from 240 MeV down to 70 MeV was also proposed. Target coverage and dose to OARs were evaluated. Results: For the sacral chordoma patient that has been planned, the target homogeneity index is 3.2% for HSV, 55.9% for CTV and 11.9% for GTV. The max dose is 77GyRBE to rectum, 86.2GyRBE to sacral nerves and 73.9GyRBE to cauda equina. Conclusion: IMPT with integrated high dose boost to HSV determined from FMISO PET image is feasible. OAR dose constraints were met.

60 APPLIED LIFE SCIENCES↗

General Applications for Hamilton Vantage (GenApps for Vantage) v0.6.1

General applications for Hamilton Vantage is a flexible liquid handling method used to automate the most widely applicable types of automated liquid transfers. General applications can also be used as a tool to onboard new fully-automated workflows by breaking them down step by step into single transfers. The goal of General Applications is to make using the Hamilton Vantage liquid handler as easy & practical as using a handheld pipette for the end user. The software supports plate-to-plate transfers for a variety of method types including: Stamp: One-to-One, Stamp: One-To-Many, Split, Combine, Hitpick, and Qtray plating. General Applications eliminates the need for automation engineers to customize individual methods for each new workflow that gets onboarded. Steps can be customized within GenApps according to the needs of the researcher. The software utilizes a GUI to prompt the users to input variables – Allowing for flexible control over plate types, transfer volumes, number of replicates, tip types, liquid classes, mixing steps, aspiration/dispense heights and more. General Applications also generates a deck image and setup instructions to guide the researcher on how to load the deck and start the instrument.

Yoder, Sam↗

Injection Principles from Combustion Studies in a 200-Pound-Thrust Rocket Engine Using Liquid Oxygen and Heptane

The importance of atomizing and mixing liquid oxygen and heptane was studied in a 200-pound-thrust rocket engine. Ten injector elements were used with both steel and transparent chambers. Characteristic velocity was measured over a range of mixture ratios. Combustion gas-flow and luminosity patterns within the chamber were obtained by photographic methods. The results show that, for efficient combustion, the propellants should be both atomized and mixed. Heptane atomization controlled the combustion rate to a much larger extent than oxygen atomization. Induced mixing, however, was required to complete combustion in the smallest volume. For stable, high-efficiency combustion and smooth engine starts, mixing after atomization was most promising.

Heidmann, M. F.↗

Estimating the Rate of Solids Accumulation in Double Shell Tanks - 17093

This project describes a method of estimating the rate of solids accumulation in Low Activity Waste Pretreatment System (LAWPS) Double Shell Tanks (DSTs) from solids entrainment and precipitation in order to identify and recommend appropriate control measures to protect LAWPS feed schedules. By comparing various volume fraction solids in transfer volumes with the available tank storage needed to maintain LAWPS feed schedules the number of possible transfers before solids removal is necessary can be determined. A family of curves spanning the range of values of volume fraction solids most frequently observed in grab samples was charted to show the transfer batch number at which point accumulated solids inhibit sufficient storage for waste feed schedules and thereby warrant solids removal. Results of this study indicate that in order to preclude solids removal activities during the LAWPS waste transfers, volume fraction settled solids levels in LAWPS transfers are required to stay below 0.0133 and 0.0183 for Feed Staging Tank 1 and 2, respectively. Results of this study show that the rate of solids accumulation will exceed the requirement, and therefore solids removal capability for LAWPS DSTs upgrades is required. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-T-209: Multicriteria Optimization Algorithm for Intensity Modulated Radiation Therapy Using Pencil Proton Beam Scanning

Purpose: To provide a multicriteria optimization algorithm for intensity modulated radiation therapy using pencil proton beam scanning. Methods: Intensity modulated radiation therapy using pencil proton beam scanning requires efficient optimization algorithms to overcome the uncertainties in the Bragg peaks locations. This work is focused on optimization algorithms that are based on Monte Carlo simulation of the treatment planning and use the weights and the dose volume histogram (DVH) control points to steer toward desired plans. The proton beam treatment planning process based on single objective optimization (representing a weighted sum of multiple objectives) usually leads to time-consuming iterations involving treatment planning team members. We proved a time efficient multicriteria optimization algorithm that is developed to run on NVIDIA GPU (Graphical Processing Units) cluster. The multicriteria optimization algorithm running time benefits from up-sampling of the CT voxel size of the calculations without loss of fidelity. Results: We will present preliminary results of Multicriteria optimization for intensity modulated proton therapy based on DVH control points. The results will show optimization results of a phantom case and a brain tumor case. Conclusion: The multicriteria optimization of the intensity modulated radiation therapy using pencil proton beam scanning provides a novel tool for treatment planning. Work support by a grant from Varian Inc.

60 APPLIED LIFE SCIENCES↗

Apollo/Skylab suit program management systems study. Volume 2: Cost analysis

The business management methods employed in the performance of the Apollo-Skylab Suit Program are studied. The data accumulated over the span of the contract as well as the methods used to accumulate the data are examined. Management methods associated with the monitoring and control of resources applied towards the performance of the contract are also studied and recommended upon. The primary objective is the compilation, analysis, and presentation of historical cost performance criteria. Cost data are depicted for all phases of the Apollo-Skylab program in common, meaningful terms, whereby the data may be applicable to future suit program planning efforts.

Source record↗