Search NASA⌕ Search

SEARCH · Search NASA

Results for “current attack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

ALLOY SELECTION AND C-276 CODE DESIGN VALUE EXTENSION FOR ADVANCED MOLTEN SALT TECHNOLOGY TEST FACILITIES EXPERIMENTATION

Molten halide salts are being considered as working fluids for nuclear and concentrated solar power applications. High temperature molten fluoride and chloride salts are known to preferentially attack and deplete Cr in alloys, which leads to the use of high-Ni lower-Cr alloys in test facilities for advanced Molten Salt Technology. Alloys 600 and C-276 are two commercially available Ni alloys that have moderate Cr contents and are qualified to the maximum temperature of 649°C and 677°C (1,200°F and 1,251°F), respectively, in the Boiler and Pressure Vessel Code. Both alloys have good corrosion resistance to acids, are resistant to stress-corrosion cracking, and have long track records of use in the chemical industry. Comparatively, Alloy C-276 has a similar Cr content but much higher allowable stresses for temperatures greater than 600°C (1,112°F). Therefore, it has been considered as a structural material for test facilities that require operations at 700°C (1,292°F) or greater to develop high-temperature Molten Salt Technology. To meet the requirements, the current code design values were extended based on some experimental data. Analysis showed that above current Codified maximum temperature, strength of the alloy is mainly controlled by creep rupture life under the average stress, although the Sc creep rate criterion is close to the Favg.Savg rupture criterion. This paper presents the intended test facilities and the design requirements, alloy selection considerations, literature review, data analysis, and proposed allowable stress extension based on some creep test data for C-276 at temperatures greater than 677°C (1,251°F). Further research activities are also briefly mentioned.

Ren, Weiju↗

Methodology and Tool for the Physical Security Analysis of Micro and Advanced Reactors

This work proposes a dynamic evaluation methodology to relax the conservatism in physical security evaluation, by leveraging an ongoing work in the Light Water Reactor Sustainability pathway. This methodology is implemented in a dynamic risk assessment tool named Event Modeling Risk Assessment using Linked Diagrams (EMRALD). The work extends EMRALD’s capability to support a sandbox feature where analysts can easily create attack scenarios and modify advanced/small modular reactor (A/SMR) security and safety features using templates. This approach saves time and cost since the analysis does not require creating detailed computer-aided design models, as is commonly required in commercial force-on-force software tools. EMRALD is completely free to use at https://emraldapp.inl.gov. We have developed basic templates including physical barriers, intrusion sensors, physical areas, and safety actions, that can be downloaded from EMRALD’s GitHub site: https://github.com/idaholab/EMRALD. These templates use generic data commonly used for training purposes, which do not reflect any actual operating nuclear reactor. Users may adjust the data in the templates with their own dataset and/or create new templates in EMRALD. The proposed methodology combines security and safety by assessing sabotage effects up to the radiological consequence to the public instead of merely the core damage state. This practice follows the industry standard for advanced non-light-water reactors currently proposed for endorsement by the Nuclear Regulatory Commission. The combination of security and safety is expressed in an achievability-consequence chart. EMRALD can be used to generate data for this chart. A hypothetical case study using a representative sodium-cooled fast reactor (SFR) facility is presented in this report to demonstrate this methodology. This case study does not contain any actual nuclear plant information. This work will benefit A/SMR vendors and utilities to implement security by design during the reactor design iteration phase, such that they do not have to perform upgrades and retrofits to the reactor after it is installed to improve its physical protection system. The tool may also be used to analyze domestic or foreign reactor designs to support the International Nuclear Security Techniques for Advanced Reactors (INSTAR) bilateral missions. Future works are planned to implement the methodology on a reference SFR reactor and a reference high-temperature gas-cooled reactor to obtain insights and lessons-learned for the A/SMR community.

97 MATHEMATICS AND COMPUTING↗

Development and application of hybrid AIMD/cDFT simulations for atomic-to-mesoscale chemistry

Many important chemical processes involve reactivity and dynamics in complex solutions. Gaining a fundamental understanding of these reaction mechanisms is a challenging goal that requires advanced computational and experimental approaches. However, important techniques such as molecular simulation have limitations in terms of scales of time, length, and system complexity. Furthermore, among the currently available solvation models, there are very few designed to describe the interaction between the molecular scale and the mesoscale. To help address this challenge, here, we establish a novel hybrid approach that couples first-principles plane-wave density functional theory with classical density functional theory (cDFT). In this approach, a region of interest described by ab initio molecular dynamics (AIMD) interacts with the surrounding medium described using cDFT to arrive at a self-consistent ground state. cDFT is a robust but efficient mesoscopic approach to accurate thermodynamics of bulk electrolyte solutions over a wide concentration range (up to 2M concentrations). Benchmarking against commonly used continuum models of solvation, such as SMD, as well as experiments, demonstrates that our hybrid AIMD–cDFT method is able to produce reasonable solvation energies for a variety of molecules and ions. With this model, we also examined the solvent effects on a prototype S N 2 reaction of the nucleophilic attack of a chloride ion on methyl chloride in the solution. The resulting reaction pathway profile and the solution phase barrier agree well with experiment, showing that our AIMD/cDFT hybrid approach can provide insight into the specific role of the solvent on the reaction coordinate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Situ: Identifying and Explaining Suspicious Behavior in Networks

Despite the best efforts of cyber security analysts, networked computing assets are routinely compromised, resulting in the loss of intellectual property, the disclosure of state secrets, and major financial damages. Anomaly detection methods are beneficial for detecting new types of attacks and abnormal network activity, but such algorithms can be difficult to understand and trust. Network operators and cyber analysts need fast and scalable tools to help identify suspicious behavior that bypasses automated security systems, but operators do not want another automated tool with algorithms they do not trust. Experts need tools to augment their own domain expertise and to provide a contextual understanding of suspicious behavior to help them make decisions. In this paper we present Situ, a visual analytics system for discovering suspicious behavior in streaming network data. Situ provides a scalable solution that combines anomaly detection with information visualization. The system's visualizations enable operators to identify and investigate the most anomalous events and IP addresses, and the tool provides context to help operators understand why they are anomalous. Finally, operators need tools that can be integrated into their workflow and with their existing tools. This paper describes the Situ platform and its deployment in an operational network setting. Furthermore, we discuss how operators are currently using the tool in a large organization's security operations center and present the results of expert reviews with professionals.

97 MATHEMATICS AND COMPUTING↗

Corrosion of Zinc Cold Spray Coatings in a Wet Sweet and Sour Gas Environment

Internal corrosion is a problem for steel pipelines transporting natural gas or CO 2 containing water and partial pressures of H 2 S higher than 0.3 kPa (0.05 psi). This work aims to mitigate internal corrosion in steel pipelines transporting natural gas containing H 2 S using cold spray coatings. Two types of the cold spray binary metallic coatings (zinc chromium [ZnCr]. zinc niobium [ZnNb]) were studied using electrochemical techniques: potentiodynamic polarization, linear polarization resistance, and electrochemical impedance spectroscopy. The corrosion resistance of cold spray coatings (ZnCr, ZnNb) was evaluated in an environment containing 4 bar CO 2 pressure, simulating the partial pressures found in gas transmission lines over a solution of 3.5 wt% NaCl heated to 40°C. A concentration of 0.003 M Na 2 S 2 O 3 ·5H 2 O, corresponding to H 2 S partial pressures around 0.079 bar (1.146 psi), was used to simulate sour conditions. Postcorrosion surface characterization was performed using a scanning electron microscope (SEM) equipped with an energy-dispersive x-ray spectroscope (EDS) and x-ray diffraction analysis. The data showed that the presence of 0.003 M Na 2 S 2 O 3 ·5H 2 O shifted the corrosion potential to more anodic values and decreased the corrosion current density. Both coatings showed similar behavior after 1 h of exposure in the CO 2 /H 2 S environment, indicating that similar electrochemical reactions were occurring on ZnNb and ZnCr. SEM images and EDS surface analyses for specimens showed a significant change in the surface chemical composition of carbon steel coated with ZnNb and ZnCr after 24 h of immersion. In the presence of thiosulfate (under sour conditions), the formation of corrosion product layers (ZnCO 3 and ZnS) on top of ZnNb and ZnCr coatings increased their corrosion resistance, which helped to reduce their corrosion by a factor of 2. Under a sweet environment, the corrosion rates for steel coated with cold spray coatings after 14 d of exposure are lower than that for galvanized steel by a factor of 5 due to the ZnCO 3 layer formed on top of the coatings. The ZnCO 3 layer formed on the steel surface acts as a physical barrier against corrosion by blocking the diffusion of corrosive species to the surface. No localized attack was observed. ZnCr Cold spray coating with defect showed promising corrosion protection against CO 2 corrosion (sweet corrosion) after 14 d of exposure to a CO 2 environment. Here, the scratch on the coating simulated damage created in service, and it was deep enough to expose the substrate material (steel). The formation of zinc oxide (ZnO) and zinc carbonate (ZnCO 3 ) on the scratch confirmed the cathodic protection of the steel by ZnCr and ZnNb coatings.

36 MATERIALS SCIENCE↗

Advanced low-cost intermetallic coatings for molten salt pump impeller. Final report

1.0 INTRODUCTION The use of solar energy to produce steam for the generation of electricity is an established technology, with multiple designs for concentrating solar power (CSP) steam generators available commercially and a number of such units currently operating. As part of the effort to improve the overall efficiency of this technology, designers have developed thermal energy storage (TES) mechanisms that employ molten salt to capture a portion of the solar energy available during the day-time hours and make that energy available for steam generation during periods when the sun’s energy is not available. In current TES systems, nitrate salts are used extensively as the medium of energy exchange. However, due to the chemical instability of these salts at temperatures above 600ºC, they are not being considered for use in the next more efficient generation of CSP plants, in which the energy exchange fluids will be required to operate in the range 600ºC to 800ºC. At these higher temperatures, molten chloride salts, such as KCl-MgCl2, are viewed as promising alternatives to the nitrate salts, but, of course, these chloride-based salts are highly corrosive to the engineering alloys commonly used in the construction of pressure vessels, heat exchangers, pumps and piping at high temperatures. Hence, a solution to the problem of material degradation is essential if the next generation of CSP plants is to be commercially viable (Ref 1). In order to effectively address the problem of molten chloride salt corrosion at high temperatures (≥ 750ºC) and thereby to reduce the cost of molten salt tanks and related apparatus, various options have been considered, with one of the most promising being an innovative coatings system developed and applied onto low alloy ferritic or austenitic stainless material. Development of such a coating system would reduce the capital costs of thermal energy storage (TES) and increase the overall efficiency of the concentrating solar power (CSP) system. Although high strength nickel base alloys are well suited for many high temperature applications, they have significant limitations when exposed to molten chloride salt conditions and they are very expensive. Monolithic materials such as the austenitic stainless steels (e.g., SS310 and SS347) and the more common nickel base alloys (e.g., IN625 and IN800H) have exhibited high corrosion rates in molten chloride salt environments (Ref1). Molten salt corrosion of IN625 in salts containing chlorides showed a catastrophic corrosion rate of 1.111”/year at 800ºC (Ref1). Hence, an innovative coatings solution to mitigate molten chloride salt corrosion is needed. Of the many coating techniques available in the market, no one technique appears to be capable of producing effective protection from molten salt corrosion at a relatively low cost. There are thermal spray coating techniques, in particular the twin wire-arc technology, that are attractive when considering the coating of large molten salt tanks because the coatings application rate is high, the overall application cost is low and repairs to the coating can readily be made either in the shop or in the field. However, the twin wire arc coating materials currently available in the market have certain inherent limitations, including porosity and mechanical bonding to the substrate, which limit their effectiveness in providing protection against molten chloride salt corrosion at high temperatures. What is required is an approach that combines the economy and versatility of thermal spray wire-arc technology with the superior resistance of advanced alloys to effectively combat molten chloride salt corrosion at elevated temperatures. Applied Thermal Coatings, Inc. (ATC) has investigated an innovative coatings technology to produce dual layer cermet/ceramic coatings that will be dense and impervious to any corrosive molten salts/fluids, thereby resisting the effects of molten salt corrosion. Development of coatings using this technology will make it possible to fabricate the molten salt systems using a relatively low-cost base material, which will reduce the overall cost of the power generating system and enhance the commercial viability of solar power. 2.0 PROJECT OVERVIEW Of the coating technologies available for the production of a cost-effective method of protection from the effects of high-temperature chloride attack, there are two that offer specific advantages for the CSP/TES application, particularly when used in a way that effectively complements the strengths of each coating method. The first of these is electroless nickel plating, through which a nickel-rich layer is produced on the surface of a component through chemical reduction. The second coating technology is aluminizing, in which aluminum is diffused into the surface of a component and, depending on the composition of the substrate, aluminides are formed. The objective of this project has been to demonstrate the feasibility of a low- cost coating for the protection of pump impellers used for the inductive transport of molten salts. Initial interest focused on an inter-metallic nickel aluminide coating and subsequently, for economic reasons, consideration also was given to a coating composed of iron aluminides. Applying such coatings to low alloy or austenitic stainless-steel substrates will provide the superior resistance to molten chloride salt corrosion and blade tip erosion that normally can be achieved only through the use of more highly alloyed – and, therefore, more expensive - nickel-base materials and it will do so at a substantially lower cost. The coating systems evaluated were designed to take advantage either of the combined strengths of the electroless nickel plating process and the aluminizing process to produce a nickel-aluminide intermetallic coating or to rely solely on the aluminizing process to produce, in conjunction with iron from the substrate, a protective layer consisting of iron aluminides. With respect to the nickel aluminide protection, this has been achieved by first depositing a layer of nickel-rich alloy onto an austenitic stainless substrate using the electroless nickel plating process and then aluminizing the nickel- coated surface to produce the nickel aluminide coating. With respect to the iron aluminide protection, this has been achieved by aluminizing bare austenitic stainless steel. Testing has supported the conclusion that the developed coatings will resist attack by molten chloride salts at high temperatures (550°C to 750°C) and have sufficient hardness to resist blade tip erosion.The steps taken to develop either a low-cost intermetallic nickel aluminide coating using electroless nickel plating and aluminizing or a low-cost iron aluminide coating using aluminizing only, and to demonstrate the quality of the coatings and their effectiveness against molten chloride salt corrosion and erosion at high temperatures (≤ 750ºC) have been as follows: 1. Design of the optimum electroless nickel plating and aluminizing mixtures using advanced thermodynamic analysis; 2. Development of processing parameters for the electroless nickel plating and aluminizing processes, to be used either together or separately; 3. Production of specimens coated using the designated electroless nickel plating process; 4. Production of samples with intermetallic nickel aluminide coating or iron aluminide coating; 5. Investigation of the performance of the intermetallic nickel aluminide coating and the iron aluminide coating when subjected to molten chloride salts corrosion at high temperatures (≥ 750ºC); and, 6. Metallurgical characterization of the microstructure of the coatings, both prior to and after exposure to molten salt environments at elevated temperatures.

14 SOLAR ENERGY↗

The Development of the Corrosion Control Limits for Direct Feed Low-Activity Waste Melter-Off Gas Returns to Hanford Tank Farms - 18196

The Savannah River National Laboratory has been developing a corrosion model to facilitate implementation of Hanford's Direct Feed Low Waste (DFLAW) flowsheet. Laboratory testing and statistical analysis have been used to determine the necessary corrosion controls for returning effluent from the Hanford Waste Treatment and Immobilization Plant's Low Activity Waste Vitrification melter off-gas treatment system to the tank farms. The stream compositions are projected to contain components at relative concentrations that are significantly more corrosive toward carbon steel, specifically halide and sulfate anions, than the current waste compositions in the tank farms. Administrative programs are in place to mitigate potential corrosion mechanisms and thereby maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. Waste chemistry and temperature control are the means by which corrosion degradation of the waste tanks is minimized. The current administrative specification for chemical composition and temperature for the underground carbon steel waste tanks is not designed to control the higher halide or sulfate composition. The content of the DFLAW waste streams will be diverse and depend on several factors, such as the melter feed composition and melter idle time. Other factors, such as effluent management of the off gas water collections, will impact the variability of the return streams even more. The work performed by the Savannah River National Laboratory has confirmed that the halide ions are the most aggressive species in the return stream compositions projected using a flowsheet simulation, and nitrite is the most effective inhibitor at pH 10 and 40 deg. C. This test program has employed statistically designed test matrices to determine the dependent variables and the interaction terms between the variables that are significant for the corrosion model and definition of the corrosion control specifications. The first phase of testing focused on identifying aggressive species in off-gas condensate return compositions that present a propensity for localized corrosion attack, namely pitting corrosion. The second phase of testing focused on developing a corrosion model from the interaction terms that will predict the susceptibility of pitting in the double shell tank system based on waste composition and the required amount of corrosion inhibitor. The data collected from this testing program in conjunction with other testing programs, both at the Savannah River Site and the Hanford Site, along with operations knowledge, has determined the chemistry ranges and chemical species requirements for corrosion control in the Hanford double-shell tank system for the effluents generated in the Hanford Waste Treatment and Immobilization Plant's Low Activity Waste facility during the DFLAW phase of operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Systematic investigations on iron cycling in phosphorus/siderophore systems: Synergism or antagonism?

Synergisms between microbial exudates on Fe (hydr)oxide dissolution as an effective Fe acquisition pathway have been recently addressed and vigorously debated. However, Fe liberation mechanisms and where siderophores and phosphorus (P) coexist received little attentions. Current study systematically investigated ferrihydrite dissolution in the presence of desferrioxamine B (DFOB) (a kind of fungally-derived siderophores) and inorganic/organic phosphorus (orthophosphate, Pi; myo-inositol hexaphosphate, IHP), as a function of solute pH, reaction time and reagent content. Reacted solids were characterized by N 2 -BET adsorption, zeta (ζ) potential analysis, sequential extraction analysis (SEDEX), field emission scanning electron microscopy (FESEM), high-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), micro Raman spectroscopy and attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR). Our results indicate that upon reaction with P-only or (DFOB + P) systems, interfacial complexation partially switched from monolayer bidentate-binuclear surface complexes to ternary complexes, or laterally transformed into amorphous Fe–P precipitates. The Fe-Pi complex precipitated more readily under acidic conditions, and Fe-IHP complex preferentially nucleated in neutral-alkaline environments. Phosphorus slightly promoted Fe release from minerals and fixation to the leached layer or interfacial liquid zone initially, but subsequently prevented further attacks from protons and DFOB. The co-effects of P and DFOB likely correspond to two successive scenarios: 1) DFOB is preferentially attracted toward ferrihydrite surfaces by negative electrical fields induced by adsorbed phosphorus and can act synergistically with labile P–Fe complexes, resulting in intensive temporal dissolution of Fh; 2) subsequent Fe shuttling to DFOB can be prohibited by stabilized, passive P/Fe–P layers. Finally, our results emphasize the antagonism between P compounds and siderophores (i.e., DFOB here) on ferrihydrite dissolution to improve understanding of the biologically-mediated Fe cycling in natural systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Literature Review of the Extraction and Analysis of Trace Contaminants in Food

There exists a serious concern that chemical warfare agents (CWA) may be used in a terrorist attack against military or civilian populations. While many precautions have been taken on the military front (e.g. protective clothing, gas masks), such precautions are not suited for the widespread application to civilian populations. Thus, defense of the civilian population, and applicable to the military population, has focused on prevention and early detection. Early detection relies on accurate and sensitive analytical methods to detect and identify CWA in a variety of matrices. Once a CWA is detected, the analytical needs take on a forensic application – are there any chemical signatures present in the sample that could indicate its source? These signatures could include byproducts of the reaction, unreacted starting materials, degradation products, or impurities. Therefore, it is important that the analytical method used can accurately identify such signatures, as well as the CWA itself. Contained herein is a review of the open literature describing the detection of CWA in various matrices and the detection of trace toxic chemicals in food. Several relevant reviews have been published in the literature,1-5 including a review of analytical separation techniques for CWA by Hooijschuur et al.1 The current review is not meant to reiterate the published manuscripts; is focused mainly on extraction procedures, as well as the detection of VX and its hydrolysis products, as it is closely related to Russian VX, which is not prevalent in the literature. It is divided by the detection technique used, as such; extraction techniques are included with each detection method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DEMONSTRATION OF LEACHXS/ORCHESTRA CAPABILITIES BY SIMULATING CONSTITUENT RELEASE FROM A CEMENTITIOUS WASTE FORM IN A REINFORCED CONCRETE VAULT

The objective of the work described in this report is to demonstrate the capabilities of the current version of LeachXS{trademark}/ORCHESTRA for simulating chemical behavior and constituent release processes in a range of applications that are relevant to the CBP. This report illustrates the use of LeachXS{trademark}/ORCHESTRA for the following applications: (1) Comparing model and experimental results for leaching tests for a range of cementitious materials including cement mortars, grout, stabilized waste, and concrete. The leaching test data includes liquid-solid partitioning as a function of pH and release rates based on laboratory column, monolith, and field testing. (2) Modeling chemical speciation of constituents in cementitious materials, including liquid-solid partitioning and release rates. (3) Evaluating uncertainty in model predictions based on uncertainty in underlying composition, thermodynamic, and transport characteristics. (4) Generating predominance diagrams to evaluate predicted chemical changes as a result of material aging using the example of exposure to atmospheric conditions. (5) Modeling coupled geochemical speciation and diffusion in a three layer system consisting of a layer of Saltstone, a concrete barrier, and a layer of soil in contact with air. The simulations show developing concentration fronts over a time period of 1000 years. (6) Modeling sulfate attack and cracking due to ettringite formation. A detailed example for this case is provided in a separate article by the authors (Sarkar et al. 2010). Finally, based on the computed results, the sensitive input parameters for this type of modeling are identified and discussed. The chemical speciation behavior of substances is calculated for a batch system and also in combination with transport and within a three layer system. This includes release from a barrier to the surrounding soil as a function of time. As input for the simulations, the physical and chemical properties of the materials are used. The test cases used in this demonstration are taken from Reference Cases for Use in the Cementitious Barriers Partnership (Langton et al. 2009). Before it is possible to model the release of substances from stabilized waste or radioactive grout through a cement barrier into the engineered soil barrier or natural soil, the relevant characteristics of such materials must be known. Additional chemical characteristics are needed for mechanistic modeling to be undertaken, not just the physical properties relevant for modeling of transport. The minimum required properties for modeling are given in Section 5.0, 'Modeling the chemical speciation of a material'.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

OECD/MCCI 2-D Core Concrete Interaction (CCI) tests : final report February 28, 2006.

Although extensive research has been conducted over the last several years in the areas of Core-Concrete Interaction (CCI) and debris coolability, two important issues warrant further investigation. The first issue concerns the effectiveness of water in terminating a CCI by flooding the interacting masses from above, thereby quenching the molten core debris and rendering it permanently coolable. This safety issue was investigated in the EPRI-sponsored Melt Attack and Coolability Experiments (MACE) program. The approach was to conduct large scale, integral-type reactor materials experiments with core melt masses ranging up to two metric tons. These experiments provided unique, and for the most part repeatable, indications of heat transfer mechanism(s) that could provide long term debris cooling. However, the results did not demonstrate definitively that a melt would always be completely quenched. This was due to the fact that the crust anchored to the test section sidewalls in every test, which led to melt/crust separation, even at the largest test section lateral span of 1.20 m. This decoupling is not expected for a typical reactor cavity, which has a span of 5-6 m. Even though the crust may mechanically bond to the reactor cavity walls, the weight of the coolant and the crust itself is expected to periodically fracture the crust and restore contact with the melt. Although crust fracturing does not ensure that coolability will be achieved, it nonetheless provides a pathway for water to recontact the underlying melt, thereby allowing other debris cooling mechanisms to proceed. A related task of the current program, which is not addressed in this particular report, is to measure crust strength to check the hypothesis that a corium crust would not be strong enough to sustain melt/crust separation in a plant accident. The second important issue concerns long-term, two-dimensional concrete ablation by a prototypic core oxide melt. As discussed by Foit the existing reactor material database for dry cavity conditions is solely one-dimensional. Although the MACE Scoping Test was carried out with a two-dimensional concrete cavity, the interaction was flooded soon after ablation was initiated to investigate debris coolability. Moreover, due to the scoping nature of this test, the apparatus was minimally instrumented and therefore the results are of limited value from the code validation viewpoint. Aside from the MACE program, the COTELS test series also investigated 2-D CCI under flooded cavity conditions. However, the input power density for these tests was quite high relative to the prototypic case. Finally, the BETA test series provided valuable data on 2-D core concrete interaction under dry cavity conditions, but these tests focused on investigating the interaction of the metallic (steel) phase with concrete. Due to these limitations, there is significant uncertainty in the partition of energy dissipated for the ablation of concrete in the lateral and axial directions under dry cavity conditions for the case of a core oxide melt. Accurate knowledge of this 'power split' is important in the evaluation of the consequences of an ex-vessel severe accident; e.g., lateral erosion can undermine containment structures, while axial erosion can penetrate the basemat, leading to ground contamination and/or possible containment bypass. As a result of this uncertainty, there are still substantial differences among computer codes in the prediction of 2-D cavity erosion behavior under both wet and dry cavity conditions. In light of the above issues, the OECD-sponsored Melt Coolability and Concrete Interaction (MCCI) program was initiated at Argonne National Laboratory. The project conducted reactor materials experiments and associated analysis to achieve the following technical objectives: (1) resolve the ex-vessel debris coolability issue through a program that focused on providing both confirmatory evidence and test data for the coolability mechanisms identified in MACE integral effects tests, and (2) address remaining uncertainties related to long-term 2-D core-concrete interactions under both wet and dry cavity conditions. Data from the various tests conducted as part of the program are being used to develop and validate models and codes that are used to extrapolate the experimental findings to plant conditions. Achievement of these technical objectives will demonstrate the efficacy of severe accident management guidelines for existing plants, and provide the technical basis for better containment designs of future plants. The project completed three large scale CCI experiments to address the second technical objective defined above.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OECD MCCI project final report, February 28, 2006.

Although extensive research has been conducted over the last several years in the areas of Core-Concrete Interaction (CCI) and debris coolability, two important issues warrant further investigation. The first issue concerns the effectiveness of water in terminating a CCI by flooding the interacting masses from above, thereby quenching the molten core debris and rendering it permanently coolable. This safety issue was investigated in the Melt Attack and Coolability Experiments (MACE) program. The approach was to conduct large scale, integral-type reactor materials experiments with core melt masses ranging up to two metric tons. These experiments provided unique, and for the most part repeatable, indications of heat transfer mechanism(s) that could provide long term debris cooling. However, the results did not demonstrate definitively that a melt would always be completely quenched. This was due to the fact that the crust anchored to the test section sidewalls in every test, which led to melt/crust separation, even at the largest test section lateral span of 1.20 m. This decoupling is not expected for a typical reactor cavity, which has a span of 5-6 m. Even though the crust may mechanically bond to the reactor cavity walls, the weight of the coolant and the crust itself is expected to periodically fracture the crust and restore contact with the melt. The fractured crust will provide a pathway for water to recontact the underlying melt, thereby allowing other debris cooling mechanisms to proceed and contribute to terminating the core-concrete interaction. Thus, one of the key aims of the current program was to measure crust strength to check the hypothesis that a corium crust would not be strong enough to sustain melt/crust separation in a plant accident. The second important issue concerns long-term, two-dimensional concrete ablation by a prototypic core oxide melt. As discussed by Foit, the existing reactor material database for dry cavity conditions is solely one-dimensional. Although the MACE Scoping Test was carried out with a two-dimensional concrete cavity, the interaction was flooded soon after ablation was initiated to investigate debris coolability. Moreover, due to the scoping nature of this test, the apparatus was minimally instrumented and therefore the results are of limited value from the code validation viewpoint. Aside from the MACE program, the COTELS test series also investigated 2-D CCI under flooded cavity conditions. However, the input power density for these tests was quite high relative to the prototypic case. Finally, the BETA test series provided valuable data on 2-D core concrete interaction under dry cavity conditions, but these tests focused on investigating the interaction of the metallic (steel) phase with concrete. Due to these limitations, there is significant uncertainty in the partitioning of energy dissipated for the ablation of concrete in the lateral and axial directions under dry cavity conditions for the case of a core oxide melt. Accurate knowledge of this 'power split' is important in the evaluation of the consequences of an ex-vessel severe accident; e.g., lateral erosion can undermine containment structures, while axial erosion can penetrate the basemat, leading to ground contamination and/or possible containment bypass. As a result of this uncertainty, there are still substantial differences among computer codes in the prediction of 2-D cavity erosion behavior under both wet and dry cavity conditions. Thus, a second key aim of the current program was to provide the necessary data to help resolve these modeling differences. In light of the above issues, the OECD-sponsored Melt Coolability and Concrete Interaction (MCCI) program was initiated at Argonne National Laboratory. The project conducted reactor materials experiments and associated analysis to achieve the following technical objectives: (1) resolve the ex-vessel debris coolability issue through a program that focused on providing both confirmatory evidence and test data for the coolability mechanisms identified in previous integral effects tests, and (2) address remaining uncertainties related to long-term 2-D core-concrete interaction under both wet and dry cavity conditions. Data from the various tests conducted as part of the program is used to develop and validate models and codes that eventually form the basis for extrapolating the experimental findings to plant conditions. Achievement of these technical objectives will demonstrate the efficacy of severe accident management guidelines for existing plants, and provide the technical basis for better containment designs of future plants. The project completed a total of eleven reactor material tests to investigate melt coolability and 2-D core-concrete interaction mechanisms under both wet and dry cavity conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Scalable Nano-Scaffold SOFC Anode Architecture Enabling Direct Hydrocarbon Utilization

This project is based on WVU’s pending patents, technology and aims to design and modify the internal surfaces of the Ni/YSZ anode from currently commercially viable Solid Oxide Fuel Cells (SOFCs) using the additive manufacturing process of Atomic Layer Deposition (ALD). The surface architecture/scaffold added onto the internal surface of the anode possesses an engineered nanostructure but it features only commonly-used oxide conductors and electro-catalyst materials. The surface layer possesses a minimum thickness of ~2-40 nm and is solely designed to control the surface reforming reactions and to increase catalytic activity. Three-dimensional (3D) nano scaffold architectures with the noble metal nano-catalyst, low-cost bimetallic catalytic alloys, and nano-scale ionic conducting oxide fully compatible with the state-of-the-art Ni/YSZ anode, were applied to the internal surface of the entire porous SOFC anode using ALD. In the present work, the surface scaffold architecture is essentially multi-functional at the nano-scale, facilitated by the multiple heterostructured interfaces. It will significantly enhance the power density and cell durability for direct hydrocarbon utilization by (1) increasing the number of electrochemical reaction sites to enhance the hydrogen/hydrocarbon oxidation reactions; (2) reducing carbon formation; (3) mitigating the coarsening of backbone Ni phase and the oxidation attack of Ni from oxidants (e.g., H2O, CO2); and (4) promoting the internal reforming capabilities, especially for natural gas applications. ALD is employed to generate stable anode surface architectures that are uniform, precisely controllable at the atomic scale, and accurately repeatable for processing. The engineered anode surface nano-scaffold architecture was cataloged and analyzed using High-resolution Transmission Electron Microscopy (TEM), and cell power/durability performance assessed via comprehensive electrochemical performance testing with commercial specimens and relevant environments using hydrocarbon fuels. To the best of our knowledge, this project is the First Report on ALD of Ni/YSZ. The actual achievement of this Project includes (1). Successful demonstration of 7 types of ALD layers on Ni/YSZ anode, including Co, Ni, Mn, Pt, Ru, ZrOx and multi-functional nano-composite. (1). Conformal coating and subsequently spontaneously pinning the discrete nano-catalyst, including the precious metal nano-catalyst and the Ni and Co catalysts, on the YSZ surface upon the electrochemical operation in the reduced atmosphere. Those nano-catalysts on the ionic-conducting YSZ provided excellent sites for promoting internal reforming; (2). Demonstrated ALD coating increased both catalytic activity and conductivity of Ni/YSZ. Conformal coating provided dopants and introduced additional electrical conducting pathways on the YSZ ionic conductor. The doped surface layer of YSZ with mixed conductivity thus further introduces the active triple phase boundaries adjacent to the ALD-coated nano-catalysts such as Pt, Co, and Ni that are pinned on the YSZ surface. The nano-composite ALD coating on Ni/YSZ anode has significantly increased cell durability; and (3). ALD coating of Ni/YSZ anode increased the power density of the entire cell by 300%. For a long time, the SOFC performance, such as the power density, was deemed hindered by the cathode. The sluggish oxygen reduction reaction (ORR) in the cathode was deemed as hindering the power density of the SOFCs. For the anode-supported commercial SOFCs, the cell performance is considered to be limited by the cathode's performance. For the first time in the field of SOFC, this project has demonstrated that (1). the performance of commercial SOFCs can be further increased by the ALD coating on Ni/YSZ anode backbone. (2). ALD coating on Ni/YSZ fuel electrodes results in the enhancement of power density, and increased reliability, robustness, and endurance of SOFCs, for their application using both hydrogen and hydrocarbon fuels over the entire operating temperature range of 650-800ºC for the inherently functional commercial cells. (3). ALD coating provides alternative approaches of exsolutions for introducing the stable catalyst onto the internal surface of the Ni/YSZ electrode. ALD coating could be much more versatile than exsolution in employing the catalysts with various chemistries onto the various backbones. (4). Due to the negligible amount of ALD materials coated onto the internal surface of the porous cathode of the as-fabricated cells, a peak power density increase up to 300 % induced by ALD coating was simultaneously achieved in terms of both power density and specific power. (5). The ALD coating developed through this project was applied to both the SOFC and Solid Oxide Electrolysis Cells (SOEC). SOEC’s face a similar but more demanding need to improve the fuel electrode's performance. It opens further research directions for electrocatalytic surface nanoionics with a wide range of chemistry. It will revolutionize our ability to render the formation of a nanostructured electrode that has been constantly pursued yet barely achieved for practical SOFC/SOEC applications. The research is also immediately transformative since both the preliminary data and the proposed work are on the direct implantation of nanoionics into the state-of-the-art inherently functional SOCs. It represents an immediate impact on the commercial sectors in SOC technology since the applied ALD processing is computer-controlled ALD coating using the commercial ALD systems, and it is scalable to both the single cells and SOC stacks.

36 MATERIALS SCIENCE↗

Enhancing Acute Migraine Treatment: Exploring Solid Lipid Nanoparticles and Nanostructured Lipid Carriers for the Nose-to-Brain Route

Migraine has a high prevalence worldwide and is one of the main disabling neurological diseases in individuals under the age of 50. In general, treatment includes the use of oral analgesics or non-steroidal anti-inflammatory drugs (NSAIDs) for mild attacks, and, for moderate or severe attacks, triptans or 5-HT1B/1D receptor agonists. However, the administration of antimigraine drugs in conventional oral pharmaceutical dosage forms is a challenge, since many molecules have difficulty crossing the blood-brain barrier (BBB) to reach the brain, which leads to bioavailability problems. Efforts have been made to find alternative delivery systems and/or routes for antimigraine drugs. In vivo studies have shown that it is possible to administer drugs directly into the brain via the intranasal (IN) or the nose-to-brain route, thus avoiding the need for the molecules to cross the BBB. In this field, the use of lipid nanoparticles, in particular solid lipid nanoparticles (SLN) and nanostructured lipid carriers (NLC), has shown promising results, since they have several advantages for drugs administered via the IN route, including increased absorption and reduced enzymatic degradation, improving bioavailability. Furthermore, SLN and NLC are capable of co-encapsulating drugs, promoting their simultaneous delivery to the site of therapeutic action, which can be a promising approach for the acute migraine treatment. This review highlights the potential of using SLN and NLC to improve the treatment of acute migraine via the nose-to-brain route. First sections describe the pathophysiology and the currently available pharmacological treatment for acute migraine, followed by an outline of the mechanisms underlying the nose-to-brain route. Afterwards, the main features of SLN and NLC and the most recent in vivo studies investigating the use of these nanoparticles for the treatment of acute migraine are presented.

Torres, Joana (ORCID:0000000327276229)↗

Optimizing power system restoration with damaged communications

Utility procedures for power system blackstart and restoration typically assume that energization decisions can be reliably communicated across the grid. In reality, the communications and control network would likely also be affected in power outages, such as those caused by extreme weather events or cyber-attacks. This paper studies the effect of damage to the power system communications and control infrastructure on restoration operations following a blackout. We model the communications infrastructure as a graph, overlaying the power grid, and imposing the requirement that every energized element in the power grid be observable from a control center. We expand on a specialized branch-and-bound algorithm from the literature to optimize the restoration process and devise an initialization heuristic and a rounding heuristic to improve solution speed. We perform numerical experiments on synthetic systems for Illinois and Texas with outages based on a solar flare or hurricane. We compare the results of our specialized branch-and-bound algorithm to the results from (i) the initialization heuristic alone, (ii) a variation of this heuristic that we use as a baseline, and (iii) the restoration optimization for the power system without communications constraints. Here, we find that damage to the communications infrastructure significantly increases the time required to re-energize the grid. Moreover, by simultaneously optimizing communications repairs and grid energization decisions, we are able to re-energize the grid significantly faster than if communications repairs and energization decisions were made independently or with partial coordination, motivating improvements to current industry practice.

97 MATHEMATICS AND COMPUTING↗

Aging Management Considerations for Dry Cask Storage Canisters - 18472

Dry cask storage systems (DCSSs) are used to store used nuclear fuel (UNF) at independent spent fuel storage installations (ISFSIs) prior to final geologic storage or reprocessing. As storage durations increase beyond the twenty-year period commonly implemented for licensing the storage sites, it is important to consider aging related degradation issues for DCSS components. A large portion of the DCSS designs used throughout the world employ a ventilated concrete overpack with a welded stainless steel canister that confines the UNF. This paper explores key issues related to aging management for these canister components, including: (1) canister environment, (2) inspection limitations, and (3) aging management program guidance and requirements. While the austenitic stainless steel used for the canisters are generally resistant to most forms of environmental attack, it is possible for conditions to arise that lead to pitting and even stress corrosion cracking of the canister systems. A large number of studies related to canister degradation have been performed by industry groups and government researchers, both in the US and worldwide. These advances in the collective knowledge provide insight into risk factors for DCSS. Such information is beneficial to improve ISFSI siting decisions and ensure successful relicensing of existing ISFSIs. This paper highlights relevant research and also discusses applicability to degradation of other equipment and containers used to process and isolate UNF and other nuclear waste streams from the public and the environment. Inspection of the canister surface is an important tool to investigate and evaluate the potential for degradation. Existing DCSS designs typically do not offer ready access to the canister surface in order to perform the inspection. Further complicating inspection efforts are the surface conditions present on the sheltered canisters after extended storage times, including atmospheric debris such as dust and pollen. Given ongoing development efforts, inspection capabilities and associated limitations should be assessed at multiple points in time over the course of an aging management program to incorporate new advances in the field. This paper explores the limitations of currently available capabilities in inspection and delivery, and provides insight into the gaps remaining to be filled to permit an effective inspection program. Recommendations and requirements related to programs for aging management of canisters have been published or are in progress from a variety of groups, including industry groups, regulatory authorities, and Codes and Standards. An effective aging management program should consider the technical bases of these various inputs and maintain compliance with requirements. Given multiple sources, decisions will be required when considering conflicting guidance, and this paper will include discussion of the relative merits of the various approaches. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Anomaly Detection in Multiple Scale for Insider Threat Analysis

We propose a method to quantify malicious insider activity with statistical and graph-based analysis aided with semantic scoring rules. Different types of personal activities or interactions are monitored to form a set of directed weighted graphs. The semantic scoring rules assign higher scores for the events more significant and suspicious. Then we build personal activity profiles in the form of score tables. Profiles are created in multiple scales where the low level profiles are aggregated toward more stable higherlevel profiles within the subject or object hierarchy. Further, the profiles are created in different time scales such as day, week, or month. During operation, the insider s current activity profile is compared to the historical profiles to produce an anomaly score. For each subject with a high anomaly score, a subgraph of connected subjects is extracted to look for any related score movement. Finally the subjects are ranked by their anomaly scores to help the analysts focus on high-scored subjects. The threat-ranking component supports the interaction between the User Dashboard and the Insider Threat Knowledge Base portal. The portal includes a repository for historical results, i.e., adjudicated cases containing all of the information first presented to the user and including any additional insights to help the analysts. In this paper we show the framework of the proposed system and the operational algorithms.

99 GENERAL AND MISCELLANEOUS↗

Differential Mobility Spectrometry-Mass Spectrometry (DMS-MS) in Radiation Biodosimetry: Rapid and High-Throughput Quantitation of Multiple Radiation Biomarkers in Nonhuman Primate Urine

High-throughput methods to assess radiation exposure are a priority due to concerns that include nuclear power accidents, the spread of nuclear weapon capability, and the risk of terrorist attacks. Metabolomics, the assessment of small molecules in an easily accessible sample, is the most recent method to be applied for the identification of biomarkers of the biological radiation response with a useful dose-response profile. Profiling for biomarker identification is frequently done using an LC-MS platform which has limited throughput due to the time-consuming nature of chromatography. We present here a chromatography-free simplified method for quantitative analysis of seven metabolites in urine with radiation dose-response using urine samples provided from the Pannkuk et al. (2015) study of long-term (7-day) radiation response in nonhuman primates (NHP). The stable isotope dilution (SID) analytical method consists of sample preparation by strong cation exchange-solid phase extraction (SCX-SPE) to remove interferences and concentrate the metabolites of interest, followed by differential mobility spectrometry (DMS) ion filtration to select the ion of interest and reduce chemical background, followed by mass spectrometry (overall SID-SPE-DMS-MS). Since no chromatography is used, calibration curves were prepared rapidly, in under 2 h (including SPE) for six simultaneously analyzed radiation biomarkers. The seventh, creatinine, was measured separately after 2500× dilution. Creatinine plays a dual role, measuring kidney glomerular filtration rate (GFR), and indicating kidney damage at high doses. The current quantitative method using SID-SPE-DMS-MS provides throughput which is 7.5 to 30 times higher than that of LC-MS and provides a path to pre-clinical radiation dose estimation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗