Validation of a Hot Water Distribution Model Using Laboratory and Field Data

Characterizing the performance of hot water distribution systems is a critical step in developing best practice guidelines for the design and installation of high performance hot water systems. Developing and validating simulation models is critical to this effort, as well as collecting accurate input data to drive the models. In this project, the ARBI team validated the newly developed TRNSYS Type 604 pipe model against both detailed laboratory and field distribution system performance data. Validation efforts indicate that the model performs very well in handling different pipe materials, insulation cases, and varying hot water load conditions. Limitations of the model include the complexity of setting up the input file and long simulation run times. In addition to completing validation activities, this project looked at recent field hot water studies to better understand use patterns and potential behavioral changes as homeowners convert from conventional storage water heaters to gas tankless units. Based on these datasets, we conclude that the current Energy Factor test procedure overestimates typical use and underestimates the number of hot water draws. This has implications for both equipment and distribution system performance. Gas tankless water heaters were found to impact how people use hot water, but the data does not necessarily suggest an increase in usage. Further study in hot water usage and patterns is needed to better define these characteristics in different climates and home vintages.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of a Hot Water Distribution Model Using Laboratory and Field Data

Characterizing the performance of hot water distribution systems is a critical step in developing best practice guidelines for the design and installation of high performance hot water systems. Developing and validating simulation models is critical to this effort, as well as collecting accurate input data to drive the models. In this project, the Building America research team ARBI validated the newly developed TRNSYS Type 604 pipe model against both detailed laboratory and field distribution system performance data. Validation efforts indicate that the model performs very well in handling different pipe materials, insulation cases, and varying hot water load conditions. Limitations of the model include the complexity of setting up the input file and long simulation run times. This project also looked at recent field hot water studies to better understand use patterns and potential behavioral changes as homeowners convert from conventional storage water heaters to gas tankless units. The team concluded that the current Energy Factor test procedure overestimates typical use and underestimates the number of hot water draws, which has implications for both equipment and distribution system performance. Gas tankless water heaters were found to impact how people use hot water, but the data does not necessarily suggest an increase in usage. Further study in hot water usage and patterns is needed to better define these characteristics in different climates and home vintages.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Software development guidelines

Analysis, modularization, flowcharting, existing programs and subroutines, compatibility, input and output data, adaptability to checkout, and general-purpose subroutines are summarized. Statement ordering and numbering, specification statements, variable names, arrays, arithemtical expressions and statements, control statements, input/output, and subroutines are outlined. Intermediate results, desk checking, checkout data, dumps, storage maps, diagnostics, and program timing are reviewed.

Kovalevsky, N.↗

Validation of WIND for a Series of Inlet Flows

Validation assessments compare WIND CFD simulations to experimental data for a series of inlet flows ranging in Mach number from low subsonic to hypersonic. The validation procedures follow the guidelines of the AIAA. The WIND code performs well in matching the available experimental data. The assessments demonstrate the use of WIND and provide confidence in its use for the analysis of aircraft inlets.

Slater, John W.↗

Development of Improved Caprock Integrity and Risk Assessment Techniques. Final report for period Oct. 1, 2012 - Sept. 30, 2014

GeoMechanics Technologies has completed a geomechanical caprock integrity analysis and risk assessment study funded through the US Department of Energy. The project included: a detailed review of historical caprock integrity problems experienced in the natural gas storage industry; a theoretical description and documentation of caprock integrity issues; advanced coupled transport flow modelling and geomechanical simulation of three large-scale potential geologic sequestration sites to estimate geomechanical effects from CO₂ injection; development of a quantitative risk and decision analysis tool to assess caprock integrity risks; and, ultimately the development of recommendations and guidelines for caprock characterization and CO₂ injection operating practices. Historical data from gas storage operations and CO₂ sequestration projects suggest that leakage and containment incident risks are on the order of 10 -1 to 10 -2 , which is higher risk than some previous studies have suggested for CO₂. Geomechanical analysis, as described herein, can be applied to quantify risks and to provide operating guidelines to reduce risks. The risk assessment tool developed for this project has been applied to five areas: The Wilmington Graben offshore Southern California, Kevin Dome in Montana, the Louden Field in Illinois, the Sleipner CO₂ sequestration operation in the North Sea, and the In Salah CO₂ sequestration operation in North Africa. Of these five, the Wilmington Graben area represents the highest relative risk while the Kevin Dome area represents the lowest relative risk.

58 GEOSCIENCES↗

Big data analytics in smart grids: state-of-the-art, challenges, opportunities, and future directions

Big data has a potential to unlock novel groundbreaking opportunities in the power grid sector that enhances a multitude of technical, social, and economic gains. The currently untapped potential of applying the science of big data for better planning and operation of the power grid is a very challenging task and needs significant efforts all-around. As power grid technologies evolve in conjunction with measurement and communication technologies, this results in unprecedented amount of heterogeneous big data sets from diverse sources. In particular, computational complexity, data security, and operational integration of big data into utility decision frameworks are the key challenges to transform the heterogeneous large dataset into actionable outcomes. Moreover, due to the complex nature of power grids along with the need to balance power in real time, seamless integration of big data into utility operations is very critical. In this context, big data analytics combined with grid visualization can lead to better situational awareness and predictive decisions. This paper presents a comprehensive state-of-the-art review of big data analytics and its applications in power grids, and also identifies challenges and opportunities from utility, industry, and research perspectives. The paper analyzes research gaps and presents insights on future research directions to integrate big data analytics into electric utility decision framework. Detailed information for utilities looking to apply big data analytics and details insights on how utilities can enhance revenue streams and bring disruptive innovation in the industry are discussed. More importantly, general guidelines for utilities to make the right investment in the adoption of big data analytics by unveiling interdependencies among critical infrastructures and operations are also provided.

13 HYDRO ENERGY↗

Analysis of Pre-Retrofit Building and Utility Data

IBACOS analyzed pre-retrofit daily utility data to sort homes by energy consumption, allowing for better targeting of homes for physical audits. Following ASHRAE Guideline 14 normalization procedures, electricity consumption of 1,166 all electric production-built homes' was modeled. The homes were in two communities -- one built in the 1970s and the other in the mid-2000s.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

STREAMS guidelines: standards for technical reporting in environmental and host-associated microbiome studies

The interdisciplinary nature of microbiome research, coupled with the generation of complex multi-omics data, makes knowledge sharing challenging. The Strengthening the Organization and Reporting of Microbiome Studies (STORMS) guidelines provide a checklist for the reporting of study information, experimental design and analytical methods within a scientific manuscript on human microbiome research. Here, in this Consensus Statement, we present the standards for technical reporting in environmental and host-associated microbiome studies (STREAMS) guidelines. The guidelines expand on STORMS and include 67 items to support the reporting and review of environmental (for example, terrestrial, aquatic, atmospheric and engineered), synthetic and non-human host-associated microbiome studies in a standardized and machine-actionable manner. Based on input from 248 researchers spanning 28 countries, we provide detailed guidance, including comparisons with STORMS, and case studies that demonstrate the usage of the STREAMS guidelines. In conclusion, STREAMS, like STORMS, will be a living community resource updated by the Consortium with consensus-building input of the broader community.

59 BASIC BIOLOGICAL SCIENCES↗

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

In Situ Soil Moisture and Thaw Depth Measurements Coincident with Airborne SAR Data Collections, Seward Peninsula, Alaska, 2019

The in-situ soil moisture and thaw depth measurements provided in this dataset were collected coincident with airborne overflights of L- and P-band SAR instruments at the Teller and Kougarok NGEE Arctic study sites on the Seward Peninsula, Alaska. Field measurements and flights were conducted in August 2019 as a collaboration between the NASA ABoVE Project's Airborne SAR Campaign and the NGEE Arctic Project. ABoVE protocols for establishing field measurement plots were followed. NGEE Arctic plots for the ground-based measurements are located at existing study sites where SAR data would also add value to current monitoring and characterization efforts of the NGEE Team. The ground-based data will be used by ABoVE to analyze, calibrate and validate the remote sensing products. This dataset follows the format and collection guidelines of the collaboration effort in 2017. Contained in this dataset are *.csv (including data dictionaries), .zip, .kml, .jpgs, .py, and .pdf files.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort (with some overlap with Covid-19 pandemic) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Complete flowfields over low and wide angle AOTV conceptual configurations

Flowfields over two conceptual aeroassisted orbital transfer vehicles, a moderate lift-to-drag ratio biconic, and an axisymmetric zero lift aerobrake are investigated. The solution procedures employ a compressible Navier-Stokes time-asymptotic technique for blunt body flow and a Parabolized Navier-Stokes spatial marching technique for the primarily supersonic shock layer flow over low-angle bodies. Emphasis is placed on the laminar convective heating predictions and comparisons to experimental data where available. Code robustness and solution times are discussed and guidelines are given for the specification of various numerical parameters. The Parabolized Navier-Stokes technique has a high probability of solution success for the range of applications considered herein, and very good comparisons with experimental heat-transfer data have been obtained. The blunt body Navier-Stokes code is more sensitive to parameter specification for the aerobrake calculations. Still, coarse grid solutions can be obtained quickly to get a good first cut at flowfield definition. Fair to good comparisons have been obtained between experimental heating and pressure data and coarse and fine grid solutions.

Gnoffo, P. A.↗

Space test program of high-voltage solar array-space plasma interactions

Future spacecraft, notably the proposed Space Station, will require power systems much larger than have previously been flown. It is recognized that at higher voltages, and at the relatively high plasma density present at low Earth orbital altitudes, undesirable interactions between the high voltage solar array and the space plasma will occur. Space experiments on high voltage solar array space plasma interactions in low Earth orbit are an absolute requirement for confident design of a higher voltage solar array. Experiments are presently being identified to provide the necessary space data for calibration of ground testing, validation of analytical models, and development of design guidelines required for confident design of high voltage solar arrays in space. A proposed flight experiment program which is designed to obtain the required data is summarized.

Carruth, M. R., Jr.↗

Considerations for the Use of Remote Gaze Tracking to Assess Behavior in Flight Simulators

Complex user interfaces (such as those found in an aircraft cockpit) may be designed from first principles, but inevitably must be evaluated with real users. User gaze data can provide valuable information that can help to interpret other actions that change the state of the system. However, care must be taken to ensure that any conclusions drawn from gaze data are well supported. Through a combination of empirical and simulated data, we identify several considerations and potential pitfalls when measuring gaze behavior in high-fidelity simulators. We show that physical layout, behavioral differences, and noise levels can all substantially alter the quality of fit for algorithms that segment gaze measurements into individual fixations. We provide guidelines to help investigators ensure that conclusions drawn from gaze tracking data are not artifactual consequences of data quality or analysis techniques.

eye tracking↗

Impact of Using Audit Data to Improve the Evidence-Based Use of Single-Fraction Radiation Therapy for Bone Metastases in British Columbia

Purpose: To assess the impact of a population-based intervention to increase the consistency and use of single-fraction radiation therapy (SFRT) for bone metastases. Methods and Materials: In 2012, an audit of radiation therapy prescriptions for bone metastases in British Columbia identified significant interphysician and -center (26%-73%) variation in the use of SFRT. Anonymous physician-level and identifiable regional cancer center SFRT use data were presented to all radiation oncologists, together with published guidelines, meta-analyses, and recommendations from practice leaders. The use of SFRT for bone metastases from 2007 through 2011 was compared with use of SFRT in 2013, to assess the impact of the audit and educational intervention. Multilevel logistic regression was used to assess the relationship between the usage of SFRT and the timing of the radiation while controlling for potentially confounding variables. Physician and center were included as group effects to account for the clustered structure of the data. Results: A total of 16,898 courses of RT were delivered from 2007 through 2011, and 3200 courses were delivered in 2013. The rates of SFRT use in 2007, 2008, 2009, 2010, 2011, and 2013 were 50.5%, 50.9%, 48.3%, 48.5%, 48.0%, and 59.7%, respectively (P<.001). Use of SFRT increased in each of 5 regional centers: A: 26% to 32%; B: 36% to 56%; C: 39% to 57%; D: 49% to 56%; and E: 73% to 85.0%. Use of SFRT was more consistent; 3 of 5 centers used SFRT for 56% to 57% of bone metastases RT courses. The regression analysis showed strong evidence that the usage of SFRT increased after the 2012 intervention (odds ratio 2.27, 95% confidence interval 2.06-2.50, P<.0001). Conclusion: Assessed on a population basis, an audit-based intervention increased utilization of SFRT for bone metastases. The intervention reversed a trend to decreasing SFRT use, reduced costs, and improved patient convenience. This suggests that dissemination of programmatic quality indicators in oncology can lead to increased utilization of evidence-based practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Jimsphere pairs for use in assessing Space Vehicle ascent capability

A data base of paired detailed wind profiles was developed for use in evaluating Shuttle Transportation System (STS) ascent capability. Since launch decision is based on a wind measured about 3.5 hr before launch, a data base of paired detailed profiles is needed. Method and technique on the reduction process and analysis is also presented. Guidelines used in selecting the pairs of profiles were established to insure a valid and representative data base. Sigma-U values for 3.5 hr at 12 km altitude show 8 percent increase from the transition case to the winter case and 18 percent decrease from the transition case to the summer case. Sigma-Values for 3.5 hr at 12 km altitude shows 12 percent increase from the transition case to the winter case and 17 percent decrease from the transition case to the summer case. A special feature of the 7- and 10.5-hr cases is that sigma-V increases by as much as 30 percent from the transition to the winter profiles. This large increase does not appear in the sigma-U data. Comparisons of the calculated values of 3.5 hr standard deviations of U and V with actual component deviations measured during space shuttle launch conditions confirm that the statistical values are representative.

Hill, C. K.↗

Final Report for Transmission of Information by Acoustic Communication along Metal Pathways in Nuclear Facilities

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall. A viable candidate for acoustic communication channel is a chemical volume control system (CVCS) stainless steel pipe, which penetrates through the containment building wall. A laboratory bench-scale system consisting of a nuclear grade CVCS-like pipe and ultrasonic transducers was assembled for a preliminary communication system analysis. Because of low bandwidth and spectral dispersion of ultrasonic transducers, on off keying (OOK) protocol was chosen for data communication. Operation of the acoustic communication during normal and post-accident conditions involves data transmission on the CVCS pipe, which according to literature guidelines, will be at 50°C and 150°C, respectively. Preliminary communication system development was performed using paintbrush PZT transducers capable of continuous operation at temperatures up to 80°C. Next, high-temperature LiNbO 3 acoustic transducers, originally developed for flow metering applications of EBRII reactor at Argonne, were utilized to develop a high-temperature acoustic communication system. A Gaussian pulse shape filter was introduced to suppress ringing and thus reduce inter-symbol interference. This resulted in enhancement of data transmission bitrate. Heating tapes, temperature controllers, and thermal insulation were installed on the laboratory pipe to study acoustic communication at elevated temperature. This included development of custom insertion heating elements for controlling temperature at pipe ends. Demonstrations of communication at high temperature included transmission of images and text files. Main achievements thus far include demonstration of transmission of 90KB image at the bitrate of 10Kbps with bit error rate smaller than 10 -3 across the pipe heated to 50°C and 150°C. Final phase of project development involved investigating strategies for deployment of the ultrasonic communication system in a representative environment. Mechanisms Engineering Test Loop (METL) facility at ANL was chosen as a viable candidate for communication system demonstration. Analysis of piping manifolds at METL has shown that in a typical scenario, ultrasonic signals have to be transmitted over straight and bent piping sections. This report describes preliminary studies on transmission of information with ultrasonic shear waves across bent piping sections. A test article consisting of a stainless steel pipe bent at 90° was developed for laboratory analysis of ultrasonic signal transmission. The bent piping test article developed by welding two straight pipes to an elbow. For consistency, the diameter and wall thickness of the bent pipe is the same as that of the straight pipe utilized in prior studies. COMSOL computer simulations were performed to study ultrasonic refracted shear wave coupling and transmission across bent piping. Preliminary evaluations of ultrasonic shear wave transmission were conducted with piezoelectric (PZT) and LiNbO 3 transducers, with the signals recorded with previously developed LabView interface. Preliminary results have shown significant dispersion of transmitted signals, most likely due to reflections and scattering by piping welds. Signal distortion compensation algorithm based on time reversal modulation (TRM) was initially investigated for transmission through solids, and demonstrated for signals transmitted over the bent pipe. Using TRM, it was shown that communication bitrates of 100Kbps were achievable, in principle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Recommended approach to sofware development

A set of guideline for an organized, disciplined approach to software development, based on data collected and studied for 46 flight dynamics software development projects. Methods and practices for each phase of a software development life cycle that starts with requirements analysis and ends with acceptance testing are described; maintenance and operation is not addressed. For each defined life cycle phase, guidelines for the development process and its management, and the products produced and their reviews are presented.

Mcgarry, F. E.↗

Tradeoffs in Prameter Values for Optional Performance

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall. A viable candidate for acoustic communication channel is a chemical volume control system (CVCS) stainless steel pipe, which penetrates through the containment building wall. A laboratory bench-scale system consisting of a nuclear grade CVCS-like pipe and ultrasonic transducers was assembled for a preliminary communication system analysis. Because of low bandwidth and spectral dispersion of ultrasonic transducers, on off keying (OOK) protocol was chosen for data communication. Operation of the acoustic communication during normal and post-accident conditions involves data transmission on the CVCS pipe, which according to literature guidelines, will be at 50°C and 150°C, respectively, In general, continuous operation of most commercial ultrasonic transducers above 50°C is challenging because of transducer material incompatibility with high temperature. High-temperature LiNbO 3 acoustic transducers, originally developed for flow metering applications of EBRII reactor at Argonne, were utilized to develop a high-temperature acoustic communication system. A Gaussian pulse shape filter was introduced to suppress ringing and thus reduce inter-symbol interference. This resulted in enhancement of data transmission bitrate. Heating tapes, temperature controllers, and thermal insulation were installed on the laboratory pipe to study acoustic communication at elevated temperature. This included development of custom insertion heating elements for controlling temperature at pipe ends. Demonstrations of communication at high temperature included transmission of images and text files. Main achievements thus far include demonstration of transmission of 90KB image at the bitrate of 10Kbps with bit error rate smaller than 10 -3 across the pipe heated to 50°C and 150⁰C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗