Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Ultrafast all-optical diffraction switching using semiconductor metasurfaces

Ultrafast all-optical switching using Mie resonant metasurfaces requires both on-demand tunability of the wavefront of the light and ultrafast time response. However, devising a switching mechanism that has a high contrast between its “on” and “off” states without compromising speed is challenging. Here, we report the design of a tunable Mie resonant metasurface that achieves this behavior. Our approach utilizes a diffractive array of semiconductor resonators that support both dipolar and quadrupolar Mie resonances. By balancing the strengths of the dipole and quadrupole resonances, we can suppress radiation into the first diffraction order, thus creating a clearly delineated “off”-state at the operating wavelength. Then, we use optical injection of free- carriers to spectrally shift the multipoles and rebalance the multipole strengths, thereby enabling radiation into the diffraction order—all on an ultrafast timescale. We demonstrate ultrafast off-to-on switching with I on /I off ≈ 5 modulation of the diffracted intensity and ultrafast on-to-off switching with Ion/Ioff ≈ 9 modulation. Furthermore, both switches exhibit a fast τ tr ≈ 2.7 ps relaxation time at 215 μJ cm -2 pump fluence. Further, we show that for higher fluences, the temporal response of the metasurface is governed by thermo-optic effects. This combination of multipole engineering with lattice diffraction opens design pathways for tunable metasurface-based integrated devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Entropy-mode-driven gas optics

We propose a class of gaseous diffractive optical elements created by imprinting an entropy mode in a gas. Previous approaches to gaseous diffractive optics have relied on the simultaneous excitation of a standing acoustic wave and an entropy mode to produce one-dimensional periodic structures. However, the presence of acoustic oscillations in the gas imposes stringent constraints on some of the operational parameters of these optical elements, such as their lifetime and diffraction angle. Here, in this work, we introduce an approach that eliminates the acoustic mode, relying solely on the entropy mode. This enables control of the lifetime and temporal profile of gaseous optical elements, and also allows the creation of arbitrary structures with greater contrast, including nonperiodic patterns such as chirped gratings or lenses. This approach should allow operation over a wider parameter space, including larger diffraction angles and compatibility with laser pulse durations ranging from femtoseconds to microseconds.

Optics and optical instruments↗

Simultaneous imaging and diffraction in the dynamic diamond anvil cell

The ability to visualize a sample undergoing a pressure-induced phase transition allows for the determination of kinetic parameters, such as the nucleation and growth rates of the high-pressure phase. For samples that are opaque to visible light (such as metallic systems), it is necessary to rely on x-ray imaging methods for sample visualization. Here, we present an experimental platform developed at beamline P02.2 at the PETRA III synchrotron radiation source, which is capable of performing simultaneous x-ray imaging and diffraction of samples that are dynamically compressed in piezo-driven diamond anvil cells. This setup utilizes a partially coherent monochromatic x-ray beam to perform lensless phase contrast imaging, which can be carried out using either a parallel- or focused-beam configuration. The capabilities of this platform are illustrated by experiments on dynamically compressed Ga and Ar. Melting and solidification were identified based on the observation of solid/liquid phase boundaries in the x-ray images and corresponding changes in the x-ray diffraction patterns collected during the transition, with significant edge enhancement observed in the x-ray images collected using the focused-beam. These results highlight the suitability of this technique for a variety of purposes, including melt curve determination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synchrotron X-ray diffraction of pyrolusite (MnO 2 ) and rutile (TiO 2 ) during heating to ~1000 °C

To compare thermal expansion behaviors in isomorphic structures with different redox behaviors, we separately heated pyrolusite (Mn 4+ O 2 ) and rutile (Ti 4+ O 2 ) powders from 25 to ~1000 °C at a rate of 0.05 °C/s at ambient pressure and analyzed them using synchrotron X-ray diffraction and Rietveld refinement. The pyrolusite exhibited two reduction-induced phase decompositions. Between 531 and 583 °C, pyrolusite decomposed to bixbyite (Mn 3+ 2 O 3 ), and between 972 and 998 °C, bixbyite decomposed to hausmannite (Mn 2+ Mn 3+ 2 O 4 ). The rutile experienced no phase decompositions or transitions over this same temperature interval. The refined bond lengths and angles for pyrolusite showed that the Mn 4+ coordination octahedron became more distorted near the phase decomposition to bixbyite due to the approach of two coordinating oxygen atoms. The 3d electrons of each Mn 4+ ion in pyrolusite make π bonds with the 2p electrons of the surrounding O 2- ions, whereas the Ti 4+ of rutile has no 3d electrons. Thus, π bonding between octahedral Mn 4+ and the surrounding O 2- anions increases the strength of the Mn–O bonds of pyrolusite relative to the Ti–O bonds of rutile. However, we observed a small decrease in O–O distances in pyrolusite before the decomposition, suggesting that at high temperature, increased π bonding between adjacent O anions precedes the release of O 2 and the reduction of Mn 4+ to Mn 3+ . Analogous behavior was observed for bixbyite before its reductive phase decomposition to hausmannite. In contrast, no anomalous changes in the O–O distances occurred for rutile. Our X-ray diffraction analyses provided accurate thermal expansion coefficients for these materials over a broader temperature range than reported in previous studies. The Mn–O bond lengths in pyrolusite were shorter and stronger than the Ti–O bonds of rutile; for example, at 60 °C, bond distances in pyrolusite refined to 1.8854(6) Å whereas the bond lengths of rutile were 1.9575(4) Å. Accordingly, the axial and volumetric thermal expansion coefficients refined for rutile were greater than those for pyrolusite. Further, the axial coefficients of thermal expansion (CTE) for pyrolusite were 96% (a-axis) and 69% (c-axis) of the corresponding values for rutile, and the volumetric CTE for pyrolusite was 85% of that for rutile.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quasi-optical beam tracing module development for millimeter-wave high-wavenumber collective scattering on the NSTX-U and EAST tokamaks

A Python3-based beam tracing code utilizing Quasi-Optics has been developed to track both incident and receiving beams in high-k collective millimeter wave scattering systems within magnetic fusion plasmas. In contrast to existing ray tracing codes that solely consider refraction, this beam tracing code incorporates diffraction phenomena, providing a more comprehensive calculation. Here, this enhanced capability allows for a more accurate calculation of the scattering volume and spatial resolution in high-k collective scattering systems, crucial for evaluating system performance and facilitating data analysis. Unlike Geometrical Optics, Quasi-Optics employs the complex eikonal method, representing a Gaussian beam as a collection of coupled rays to accurately preserve diffraction characteristics. The developed code is intended for application in NSTX-Upgrade and EAST high-k beam tracing analyses, targeting frequencies of 693 GHz and 270 GHz, respectively. The high-k system's primary objective is the observation of electron-scale instabilities. Employing a symplectic integrator, the code ensures numerical accuracy, assessed through the conservation of the Hamiltonian. With its precision and efficiency, the code facilitates rapid inter-shot analyses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structure and properties of densified silica glass: characterizing the order within disorder

The broken symmetry in the atomic-scale ordering of glassy versus crystalline solids leads to a daunting challenge to provide suitable metrics for describing the order within disorder, especially on length scales beyond the nearest neighbor that are characterized by rich structural complexity. Here, we address this challenge for silica, a canonical network-forming glass, by using hot versus cold compression to (i) systematically increase the structural ordering after densification and (ii) prepare two glasses with the same high-density but contrasting structures. The structure was measured by high-energy X-ray and neutron diffraction, and atomistic models were generated that reproduce the experimental results. The vibrational and thermodynamic properties of the glasses were probed by using inelastic neutron scattering and calorimetry, respectively. Traditional measures of amorphous structures show relatively subtle changes upon compacting the glass. The method of persistent homology identifies, however, distinct features in the network topology that change as the initially open structure of the glass is collapsed. The results for the same high-density glasses show that the nature of structural disorder does impact the heat capacity and boson peak in the low-frequency dynamical spectra. Densification is discussed in terms of the loss of locally favored tetrahedral structures comprising oxygen-decorated SiSi 4<:sub> tetrahedra.

36 MATERIALS SCIENCE↗

In situ X-ray ptychography imaging of high-temperature CO{sub 2} acceptor particle agglomerates

Imaging nanoparticles under relevant reaction conditions of high temperature and gas pressure is difficult because conventional imaging techniques, like transmission electron microscopy, cannot be used. Here we demonstrate that the coherent diffractive imaging technique of X-ray ptychography can be used for in situ phase contrast imaging in structure studies at atmospheric pressure and elevated temperatures. Lithium zirconate, a candidate CO{sub 2} capture material, was studied at a pressure of one atmosphere in air and in CO{sub 2}, at temperatures exceeding 600 °C. Images with a spatial resolution better than 200 nm were retrieved, and possibilities for improving the experiment are described.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intermixing in Cu/Ni multilayers induced by cold rolling

Repeated cold rolling was performed on multilayers of Cu60/Ni40 and Cu40/Ni60 foil arrays to study the details of driven atomic scale interfacial mixing. With increasing deformation, there is a significant layer refinement down to the nm level that leads to the formation of a solid solution phase from the elemental end members. Intriguingly, the composition of the solid solution is revealed by an oscillation in the composition profile across the multilayers, which is different from the smoothly varying profile due to thermally activated diffusion. During the reaction, Cu mixed into Ni preferentially compared to Ni mixing into Cu, which is also in contrast to the thermal diffusion behavior. This is confirmed by observations from X-ray diffraction, electron energy loss spectrum and atom probe tomography. The diffusion coefficient induced by cold rolling is estimated as 1.7 × 10{sup −17} m{sup 2}/s, which cannot be attributed to any thermal effect. The effective temperature due to the deformation induced mixing is estimated as 1093 K and an intrinsic diffusivity d{sub b}, which quantifies the tendency towards equilibrium in the absence of thermal diffusion, is estimated as 6.38 × 10{sup −18} m{sup 2}/s. The fraction of the solid solution phase formed is illustrated by examining the layer thickness distribution and is described by using an error function representation. The evolution of mixing in the solid solution phase is described by a simplified sinusoid model, in which the amplitude decays with increased deformation level. The promoted diffusion coefficient could be related to the effective temperature concept, but the establishment of an oscillation in the composition profile is a characteristic behavior that develops due to deformation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic Precursor of the Pressure-Induced Superconductivity in Fe-Ladder Compounds

We studied the pressure effects on the antiferromagentic orders in iron-based ladder compounds CsFe$_2$Se$_3$ and BaFe$_2$S$_3$ using single crytal neutron diffraction technique. With identical crystal structure and similar magnetic structures, the two compounds exhibit highly contrasting magnetic behaviors under moderate external pressures. In CsFe$_2$Se$_3$ the ladders are brought much closer to each other by pressure, but the stripe-type of magnetic order shows no observable change. Furthermore, the stripe order in BaFe$_2$S$_3$, undergoes a quantum phase transition where an abrupt increase of $N\acute{e}el$ temperature by more than 50$\%$ occurs at about 1 GPa, accompanied by a jump in ordered moment. Finally, with its spin structure unchanged, BaFe$_2$S$_3$ enters an enhanced magnetic phase that bears the characteristics of an orbital selective Mott phase, which is the true herald for superconductivity emerging at higher pressures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The local post-perovskite structure and its temperature dependence : atom-pair distances in CalrO{sub 3} revealed through analysis of the total x-ray scattering at high temperatures.

The temperature-dependent post-perovskite structure model of MgSiO{sub 3} is reinvestigated through analysis of the atom-pair distances observed experimentally via Fourier transformation of X-ray diffraction and diffuse scattering, the total X-ray scattering, from CaIrO{sub 3}. In contrast to the results of a previous Rietveld structure refinement, which shows a negative or null thermal expansion of Ir-O and Ca-O bond lengths within the average long-range structure, visual inspection of these atom-pair distances in the pair-distribution function, in addition to structure models fitted through least-squares refinement to this local-structure data, strongly suggests that these distances between atom pairs increase with temperature. The average long-range structure of CaIrO{sub 3}, visible from Rietveld structure refinement, is distinct from the short-range structure ({le} 18 {angstrom}) at all of the temperatures examined in this study (325-1114 K) and is reproduced in structure models fitted to the pair-distribution function extending to sufficiently long atom-pair distances ({ge} 50 {angstrom}). While previous data obtained with Rietveld structure refinement show the iridium coordination octahedra to distort with increasing temperature, models of the short-range structure demonstrate that these polyhedra instead reduce distortion and rotate in a manner similar to that occurring in the perovskite structure.

36 MATERIALS SCIENCE↗

HCIT Broadband Contrast Performance Sensitivity Studies

One of the important milestones of the TPF Coronagraph project is to demonstrate the ability to predict the performance sensitivities of the system at levels consistent with exo-planet detection requirement. We want to gain some general understanding about the potentials and the limitations of the current single-Deformable-Mirror (DM) High-contrast imaging testbed (HCIT) system through modeling and simulations. Specifically, we want to understand the effects of some common errors on the EFC-based control of e-field over a half dark-hole region and broadband contrast. Investigated errors include: (1) Absorbing particles on a flat-mirror (2) Defects on the Occulter surface (3) Dead actuators on the DM. We also investigated the effects of control bandwidth on the broadband contrast. We used a MACOS-based simulation algorithm which (1) combines a ray trace, diffraction model, & a broadband wavefront control algorithm (2) is capable of performing full three-dimensional near-field diffraction analysis

exoplanets↗

ExEP: Initial super-Nyquist wavefront control experiments in the Decadal Survey Testbed

In order to characterize exoplanets around nearby stars, upcoming and proposed space telescopes are being designed with high contrast coronagraph instruments. Coronagraphs are generally designed to suppress only a single, on-axis star, but there are numerous binary star systems within our observational range. Multi-star wavefront correction (MSWC) is a technique that uses deformable mirror(s) to simultaneously suppress light from more than one star to create a high contrast dark zone in the image. MSWC has already been well demonstrated in simulation and in air-based testbeds. In this paper, we describe our prepatory vacuum experiments in the Decadal Survey Testbed (DST) at the Jet Propulsion Laboratory. First we implemented super-Nyquist wavefront control (SNWC, a critical component of MSWC), and then we proceeded to simultaneous sub- and super-Nyquist control. With our existing calibration methods, SNWC reached a contrast of $8.6{\times}10^{-9}$ in a 10\% bandpass around a first-order diffraction spot; calibration improvements are needed to improve model agreement for higher-order spots. We have also implemented changes to our software (the open-source package FALCO) required for MSWC, and identified the necessary changes in hardware. Here we report our best SNWC lab results and our plans for implementing MSWC during a future set of experiments.

Bendek, Eduardo↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crystallographic features related to a van der Waals coupling in the layered chalcogenide FePS{sub 3}

We investigated the crystallographic structure of FePS{sub 3} with a layered structure using transmission electron microscopy and powder X-ray diffraction. We found that FePS{sub 3} forms a rotational twin structure with the common axis along the c*-axis. The high-resolution transmission electron microscopy images revealed that the twin boundaries were positioned at the van der Waals gaps between the layers. The narrow bands of dark contrast were observed in the bright-field transmission electron microscopy images below the antiferromagnetic transition temperature, T{sub N} ≈ 120 K. Low-temperature X-ray diffraction showed a lattice distortion; the a- and b-axes shortened and lengthened, respectively, as the temperature decreased below T{sub N.} We propose that the narrow bands of dark contrast observed in the bright-field transmission electron microscopy images are caused by the directional lattice distortion with respect to each micro-twin variant in the antiferromagnetic phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Incommensurate Spiral Spin Order in CaMn 2 Bi 2 Observed via High-Pressure Neutron Diffraction

Here, high-pressure neutron diffraction is employed to investigate the magnetic behavior of CaMn 2 Bi 2 in extreme conditions. In contrast to antiferromagnetic ordering on Mn atoms reported at ambient pressure, our results reveal that at high pressure, incommensurate spiral spin order emerges due to the interplay between magnetism on the Mn atoms and strong spin–orbit coupling on the Bi atoms: sinusoidal spin order is observed at pressures as high as 7.4 GPa. First-principles calculations with a noncollinear spin orientation demonstrate band crossing behavior near the Fermi level as a result of strong hybridization between the d orbitals of Mn and the p orbitals of Bi atoms. Competing antiferromagnetic order is observed at different temperatures in the partially frustrated lattice. Theoretical models have been developed to investigate spin dynamics. This research provides a unique toolbox for conducting experimental and theoretical magnetic and spin dynamics studies of magnetic quantum materials via high-pressure neutron diffraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Apparatus and method for creating a photonic densely-accumulated ray-point

An optical apparatus includes an optical diffraction device configured for diffracting a predetermined wavelength of incident light onto adjacent optical focal points, and a photon detector for detecting a spectral characteristic of the predetermined wavelength. One of the optical focal points is a constructive interference point and the other optical focal point is a destructive interference point. The diffraction device, which may be a micro-zone plate (MZP) of micro-ring gratings or an optical lens, generates a constructive ray point using phase-contrasting of the destructive interference point. The ray point is located between adjacent optical focal points. A method of generating a densely-accumulated ray point includes directing incident light onto the optical diffraction device, diffracting the selected wavelength onto the constructive interference focal point and the destructive interference focal point, and generating the densely-accumulated ray point in a narrow region.

Park, Yeonjoon↗

Potassium tantalate substrates for neutron experiments on antiferromagnetic perovskite films

For the study of antiferromagnetism in thin-film materials, neutron diffraction is a particularly important tool, especially since magnetometry experiments are often complicated by the substrate’s strong diamagnetic contribution. However, the substrate, by necessity, has a lattice parameter that is very similar to that of the film, and in most cases is over 1000 times more massive than the film. Therefore, even weak structural distortions in the substrate crystal may complicate the analysis of magnetic scattering from the film. Here we show that in contrast to most other perovskite substrates (including SrTiO3, LaAlO3, etc.), KTaO3 provides a uniquely appropriate substrate platform for magnetic diffraction experiments on epitaxial oxide films.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantitative Imaging of Single, Unstained Viruses with Coherent X Rays

We report the recording and reconstruction of x-ray diffraction patterns from single, unstained viruses, for the first time. By separating the diffraction pattern of the virus particles from that of their surroundings, we performed quantitative and high-contrast imaging of a single virion. The structure of the viral capsid inside a virion was visualized. This work opens the door for quantitative x-ray imaging of a broad range of specimens from protein machineries and viruses to cellular organelles. Moreover, our experiment is directly transferable to the use of x-ray free electron lasers, and represents an experimental milestone towards the x-ray imaging of large protein complexes.

60 APPLIED LIFE SCIENCES↗