Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed wind technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Reactive power interconnection requirements for PV and wind plants : recommendations to NERC

Voltage on the North American bulk system is normally regulated by synchronous generators, which typically are provided with voltage schedules by transmission system operators. In the past, variable generation plants were considered very small relative to conventional generating units, and were characteristically either induction generator (wind) or line-commutated inverters (photovoltaic) that have no inherent voltage regulation capability. However, the growing level of penetration of non-traditional renewable generation - especially wind and solar - has led to the need for renewable generation to contribute more significantly to power system voltage control and reactive power capacity. Modern wind-turbine generators, and increasingly PV inverters as well, have considerable dynamic reactive power capability, which can be further enhanced with other reactive support equipment at the plant level to meet interconnection requirements. This report contains a set of recommendations to the North-America Electricity Reliability Corporation (NERC) as part of Task 1-3 (interconnection requirements) of the Integration of Variable Generation Task Force (IVGTF) work plan. The report discusses reactive capability of different generator technologies, reviews existing reactive power standards, and provides specific recommendations to improve existing interconnection standards.

14 SOLAR ENERGY↗

Energy Storage for Power Systems Applications: A Regional Assessment for the Northwest Power Pool (NWPP)

Wind production, which has expanded rapidly in recent years, could be an important element in the future efficient management of the electric power system; however, wind energy generation is uncontrollable and intermittent in nature. Thus, while wind power represents a significant opportunity to the Bonneville Power Administration (BPA), integrating high levels of wind resources into the power system will bring great challenges to generation scheduling and in the provision of ancillary services. This report addresses several key questions in the broader discussion on the integration of renewable energy resources in the Pacific Northwest power grid. More specifically, it addresses the following questions: a) how much total reserve or balancing requirements are necessary to accommodate the simulated expansion of intermittent renewable energy resources during the 2019 time horizon, and b) what are the most cost effective technological solutions for meeting load balancing requirements in the Northwest Power Pool (NWPP).

17 WIND ENERGY↗

Setting cost targets for zero-emission electricity generation technologies

Clean energy deployment scenarios typically assume a diverse mix of low-emission generation. However, because of historically low natural gas prices and cost reductions for onshore wind and photovoltaic technologies, recent new capacity deployment, especially in the United States, has come largely from these three generation sources. Here, we quantify competitive cost targets for three less-common zero-emission generation technologies -- nuclear, concentrating solar, and offshore wind -- under a range of future conditions. We determine the cost targets based on the technologies' system value, such that technology value equals or exceeds its cost. Using a capacity expansion model that develops system-wide, economically optimal generation scenarios of the United States power sector, we find that nuclear, concentrating solar, and offshore wind would need to attain levelized cost ranges of $53-84/MWh, $65-91/MWh, and $39-77/MWh, respectively, to achieve 1% additional grid penetration. We refer to this metric as the 'required cost,' which is a technology's levelized cost of energy needed to achieve a specific penetration level. Higher penetrations lead to lower required costs as lower-cost generation is displaced. We estimate that to reach 10% penetration, the required cost for nuclear declines to $45-76/MWh. Because of resource variability and increased transmission needs for concentrating solar power and offshore wind, even lower costs are needed to reach higher penetrations: required cost ranges to achieve 10% penetration are estimated to be $30-56/MWh and $18-40/MWh for these two technologies respectively. Our analysis informs research and development priorities and the design of policies supporting clean technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nano-ADEPT Aeroloads Wind Tunnel Test

A wind tunnel test of the Adaptable Deployable Entry and Placement Technology (ADEPT) was conducted in April 2015 at the US Army's 7 by10 Foot Wind Tunnel located at NASA Ames Research Center. Key geometric features of the fabric test article were a 0.7 meter deployed base diameter, a 70 degree half-angle forebody cone angle, eight ribs, and a nose-to-base radius ratio of 0.7. The primary objective of this wind tunnel test was to obtain static deflected shape and pressure distributions while varying pretension at dynamic pressures and angles of attack relevant to entry conditions at Earth, Mars, and Venus. Other objectives included obtaining aerodynamic force and moment data and determining the presence and magnitude of any dynamic aeroelastic behavior (buzz/flutter) in the fabric trailing edge. All instrumentation systems worked as planned and a rich data set was obtained. This paper describes the test articles, instrumentation systems, data products, and test results. Four notable conclusions are drawn. First, test data support adopting a pre-tension lower bound of 10 foot pounds per inch for Nano-ADEPT mission applications in order to minimize the impact of static deflection. Second, test results indicate that the fabric conditioning process needs to be reevaluated. Third, no flutter/buzz of the fabric was observed for any test condition and should also not occur at hypersonic speeds. Fourth, translating one of the gores caused ADEPT to generate lift without the need for a center of gravity offset. At hypersonic speeds, the lift generated by actuating ADEPT gores could be used for vehicle control.

system engineering↗

Building and grid system benefits of demand flexibility and energy efficiency

The global electricity system is undergoing a dramatic transformation. Technology advancements in clean energy generation (e.g., solar photovoltaics and wind) and electrified demand (e.g., transportation and building heating) are providing a cost-competitive pathway to mitigate the urgent and severe consequences associated with a changing climate. In addition, as extreme events continue to increase in frequency and magnitude, solutions are needed for adapting to the current climate. Through energy efficiency and demand flexibility, buildings play a prominent role in meeting these challenges; recently in Joule, a paper by Langevin et al. provides clear insight into the magnitude of buildings’ technical potential.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2015 Standard Scenarios Annual Report: U.S. Electric Sector Scenario Exploration

This report is one of several products resulting from an initial effort to provide a consistent set of technology cost and performance data and to define a conceptual and consistent scenario framework that can be used in the National Renewable Energy Laboratory’s (NREL’s) future analyses. The long-term objective of this effort is to identify a range of possible futures of the U.S. electricity sector in which to consider specific energy system issues through (1) defining a set of prospective scenarios that bound ranges of key technology, market, and policy assumptions and (2) assessing these scenarios in NREL’s market models to understand the range of resulting outcomes, including energy technology deployment and production, energy prices, and carbon dioxide (CO2) emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstration of Grid Services Using Mixed Grid-Forming and Grid-Following Technologies at the Wheatridge Renewable Energy Facility (Final Technical Report)

This Final Technical Report summarizes the analytical, modeling, and engineering work performed to evaluate grid-forming (GFM) inverter capabilities within a large hybrid renewable energy facility. The project focused on assessing the ability of advanced inverter-based resources to provide essential reliability services through coordinated operation of grid-forming (GFM) and grid-following (GFL) technologies. During Budget Period 1, the project developed a comprehensive framework of GFM performance metrics, including angle support, voltage regulation, frequency response, damping behavior, and current-limiting performance. Extensive electromagnetic transient (EMT) studies and hardware-in-the-loop (HIL) testing were conducted to validate GFM behavior under a range of operating conditions, including weak-grid scenarios, voltage disturbances, and multi-resource interactions. The project also established validated modeling approaches, plant-level control integration strategies, commissioning frameworks, and high-speed measurement infrastructure to support future field demonstration. Although the project concluded prior to field demonstration, the results provide a utility-scale foundation for evaluating, modeling, and deploying grid-forming technologies. The methodologies and tools developed contribute to industry understanding of inverter-based resource behavior and support future power system reliability under increasing renewable penetration.

14 SOLAR ENERGY↗

Design Guidelines for Deployable Wind Turbines for Military Operational Energy Applications

This document aims to provide guidance on the design and operation of deployable wind systems that provide maximum value to missions in defense and disaster relief. Common characteristics of these missions are shorter planning and execution time horizons and a global scope of potential locations. Compared to conventional wind turbine applications, defense and disaster response applications place a premium on rapid shipping and installation, short-duration operation (days to months), and quick teardown upon mission completion. Furthermore, defense and disaster response applications are less concerned with cost of energy than conventional wind turbine applications. These factors impart design drivers that depart from the features found in conventional distributed wind turbines, thus necessitating unique design guidance. The supporting information for this guidance comes from available relevant references, technical analyses, and input from industry and military stakeholders. This document is not intended to be a comprehensive, prescriptive design specification. This document is intended to serve as a written record of an ongoing discussion of stakeholders about the best currently available design guidance for deployable wind turbines to help facilitate the effective development and acquisition of technology solutions to support mission success. The document is generally organized to provide high-level, focused guidance in the main body, with more extensive supporting details available in the referenced appendices. Section 2 begins with a brief qualitative description of the design guidelines being considered for the deployable wind turbines. Section 3 provides an overview of the characteristics of the mobile power systems commonly used in U.S. military missions. Section 4 covers current military and industry standards and specifications that are relevant to a deployable wind turbine design. Section 5 presents the deployable turbine design guidelines for the application cases.

17 WIND ENERGY↗

Some experiences using wind-tunnel models in active control studies

A status report and review of wind tunnel model experimental techniques that have been developed to study and validate the use of active control technology for the minimization of aeroelastic response are presented. Modeling techniques, test procedures, and data analysis methods used in three model studies are described. The studies include flutter mode suppression on a delta-wing model, flutter mode suppression and ride quality control on a 1/30-size model of the B-52 CCV airplane, and an active lift distribution control system on a 1/22 size C-5A model.

Doggett, R. V., Jr.↗

The Evolution of the DARWIN System

DARWIN is a web-based system for presenting the results of wind-tunnel testing and computational model analyses to aerospace designers. DARWIN captures the data, maintains the information, and manages derived knowledge (e.g. visualizations, etc.) of large quantities of aerospace data. In addition, it provides tools and an environment for distributed collaborative engineering. We are currently constructing the third version of the DARWIN software system. DARWN's development history has, in some sense, tracked the development of web applications. The 1995 DARWIN reflected the latest web technologies--CGI scripts, Java applets and a three-layer architecture--available at that time. The 1997 version of DARWIN expanded on this base, making extensive use of a plethora of web technologies, including Java/JavaScript and Dynamic HTML. While more powerful, this multiplicity has proven to be a maintenance and development headache. The year 2000 version of DARWIN will provide a more stable and uniform foundation environment, composed primarily of Java mechanisms. In this paper, we discuss this evolution, comparing the strengths and weaknesses of the various architectural approaches and describing the lessons learned about building complex web applications.

Walton, Joan D.↗

Potential Availability of and Supply Curves for Low-Cost, Dispatch-Constrained Electricity

Among other changes, variable renewable energy (VRE) - primarily wind and solar photovoltaics - is achieving a growing share of total generation. High VRE penetrations may result in an increased level of curtailment and thus suppress the value of additional VRE. This VRE, that either would not be built due to price suppression or would be curtailed, can be considered a resource that we define as low-cost, dispatch-constrained electricity (LDE). LDE could be used for various applications which value low-cost electricity and can operate at reduced capacity factors. Examples include electrolytic hydrogen production and carbon capture. This report provides initial estimates of the quantity and availability of the potential LDE resource in the U.S. under scenarios with high VRE penetrations. It also provides supply curves that can be used in subsequent analysis of the opportunity to use the LDE. We modeled several scenarios using capacity expansion and production cost models for LDE prices ranging from $\$ $0/MWh to $\$ $30/MWh. These LDE prices, coupled with low renewable energy cost assumptions, resulted in VRE penetrations ranging from 48-66% in 2050. The resulting LDE supplies range from 100 - 300 TWh/yr at a price of $\$ $0/MWh to 3,500 - 4,200 TWh/yr at $\$ $30/MWh. Increasing LDE prices increases wind and photovoltaics deployment; however, other generation technology capacities do not decrease equivalently in our models. Thus, additional generation is available but the capacity of traditional dispatchable generation is only reduced slightly. The available LDE is concentrated in the central and southwest U.S. regions because of their high wind and solar resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing the NASA Prediction of Worldwide Energy Resource Web Data Delivery System with Geographic Information System (GIS) Capabilities

Renewable energy technologies are changing the face of the world's energy market. Currently, these technologies are being incorporated within existing structures to increase energy efficiency. Crucial to the success of the emerging renewable market is the availability of accurate, global solar radiation, and meteorology data. This poster traces the history of the development of an effort to distribute data parameters from NASA's research for use in the energy sector applications spanning from renewable energy to energy efficiency. These data may be useful to several renewable energy sectors: solar and wind power generation, agricultural crop modeling, and sustainable buildings.

Chandler, William S.↗

Nonlinear evolution of the electromagnetic electron-cyclotron instability in bi-Kappa distributed plasma

This paper presents a numerical study of the linear and nonlinear evolution of the electromagnetic electron-cyclotron (EMEC) instability in a bi-Kappa distributed plasma. Distributions with high energy tails described by the Kappa power-laws are often observed in collision-less plasmas (e.g., solar wind and accelerators), where wave-particle interactions control the plasma thermodynamics and keep the particle distributions out of Maxwellian equilibrium. Under certain conditions, the anisotropic bi-Kappa distribution gives rise to plasma instabilities creating low-frequency EMEC waves in the whistler branch. The instability saturates nonlinearly by reducing the temperature anisotropy until marginal stability is reached. Numerical simulations of the Vlasov-Maxwell system of equations show excellent agreement with the growth-rate and real frequency of the unstable modes predicted by linear theory. The wave-amplitude of the EMEC waves at nonlinear saturation is consistent with magnetic trapping of the electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatially resolved land and grid model of carbon neutrality in China

China has committed to achieve net carbon neutrality by 2060 to combat global climate change, which will require unprecedented deployment of negative emissions technologies, renewable energies (RE), and complementary infrastructure. At terawatt-scale deployment, land use limitations interact with operational and economic features of power systems. To address this, we developed a spatially resolved resource assessment and power systems planning optimization that models a full year of power system operations, sub-provincial RE siting criteria, and transmission connections. Our modeling results show that wind and solar must be expanded to 2,000 to 3,900 GW each, with one plausible pathway leading to 300 GW/yr combined annual additions in 2046 to 2060, a three-fold increase from today. Over 80% of solar and 55% of wind is constructed within 100 km of major load centers when accounting for current policies regarding land use. Large-scale low-carbon systems must balance key trade-offs in land use, RE resource quality, grid integration, and costs. Under more restrictive RE siting policies, at least 740 GW of distributed solar would become economically feasible in regions with high demand, where utility-scale deployment is limited by competition with agricultural land. Effective planning and policy formulation are necessary to achieve China’s climate goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reevaluation of air surveillance station siting

DOE Technical Standard HDBK-1216-2015 (DOE 2015) recommends evaluating air-monitoring station placement using the analytical method developed by Waite. The technique utilizes wind rose and population distribution data in order to determine a weighting factor for each directional sector surrounding a nuclear facility. Based on the available resources (number of stations) and a scaling factor, this weighting factor is used to determine the number of stations recommended to be placed in each sector considered. An assessment utilizing this method was performed in 2003 to evaluate the effectiveness of the existing SRS air-monitoring program. The resulting recommended distribution of air-monitoring stations was then compared to that of the existing site perimeter surveillance program. The assessment demonstrated that the distribution of air-monitoring stations at the time generally agreed with the results obtained using the Waite method; however, at the time new stations were established in Barnwell and in Williston in order to meet requirements of DOE guidance document EH-0173T.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Green Pricing Program Marketing Expenditures: Finding the Right Balance

In practice, it is difficult to determine the optimal amount to spend on marketing and administering a green pricing program. Budgets for marketing and administration of green pricing programs are a function of several factors: the region of the country; the size of the utility service area; the customer base and media markets encompassed within that service area; the point or stage in the lifespan of the program; and certainly, not least, the utility's commitment to and goals for the program. All of these factors vary significantly among programs. This report presents data on programs that have funded both marketing and program administration. The National Renewable Energy Laboratory (NREL) gathers the data annually from utility green pricing program managers. Programs reporting data to NREL spent a median of 18.8% of program revenues on marketing their programs in 2008 and 16.6% in 2007. The smallest utilities (those with less than 25,000 in their eligible customer base) spent 49% of revenues on marketing, significantly more than the overall median. This report addresses the role of renewable energy credit (REC) marketers and start-up costs--and the role of marketing, generally, in achieving program objectives, including expansion of renewable energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Nuclear Role in Electricity Supply: Moving Away from Baseload

The operation of electric power systems has always required consideration of the pattern of demand for electricity, the operating characteristics of the available generators, the capacity and topology of the grid, and a myriad of uncertainties in each of these parameters. Solar, wind, and nuclear generators all have great potential for growth and will eventually be the dominant generating technologies. The dramatic improvements in nuclear plant capacity factors over the last {approx}20 years have resulted in substantially better economic utilization of our most capital-intensive plants, and this high level of economic utilization needs to continue if we want to avoid major increases in long-term cost of electricity generation. The goal to reduce carbon emissions without substantial long-term cost increases in electricity generation sets up a couple technology development goals. We must develop methods to integrate and control different types of primary energy generators; we must investigate options to couple the primary energy sources used for electricity generation to other sectors of the economy; and we must identify the lowest-capital-cost energy storage system options. (authors)

24 POWER TRANSMISSION AND DISTRIBUTION↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗