Search NASA⌕ Search

SEARCH · Search NASA

Results for “eigenvalues”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Measuring alpha eigenvalue of a subcritical system by a intense pulsed neutron source

Intense-Pulsed-Neutron-Source (IPNS) technique is a new approach to measure the subcriticality of a reactor system, which has been theoretically analyzed by us while not been verified in experiment in other reference. In INPS technique the reactivity is derived via the system response to a prompt pulsed neutron source. The method utilizes very intense neutron pulses (about 1010 neutrons/pulse) with the duration ranging from 10 ns to 100 ns, which are generated by the dense plasma focus (DPF) device filled with pure DT mixture as the working gas. The neutron pulse in high intensity provides the opportunity to measure the signal using a scintillator and a photo-multiplier tube (PMT) (the intense pulse radiation measure method) with the flight distance of only twenty centimeters. The attenuation of the dense plasma focus device must be faster than the subcritical system so that the attenuation of the system can be researched. In this paper, after a neutron pulse is injected into the subcritical reactor, the subcriticality is determined by measuring the instantaneous characteristics of the leaking reactor neutron. The Monte Carlo analysis shows that, with the linear arrangement of the dense plasma focus, the subcritical system and the detector, the signal-to-noise ratio at the measure point meets the investigate requirement, in which the 14 MeV neutrons are attenuated by the subcritical system. The detector is close with the subcritical system to reduce the influence of the outer background and the spread of time-of-flight of the neutrons. The measure system utilizing gated detection technology is characterized with fast attenuation time and large linear current, the a value obtained with this method is 2.05 μs{sup -1} while the measurements using the {sup 252}Cf stochastic pulsed source method and the Rossi-a method were 2.18μs{sup -1} and 2.16μs{sup -1}.It showed that the measured result obtained with dense plasma focus instantaneous pulsed source is consistent with those obtained with the other two traditional methods. This new method utilized only a single-shot pulse to determine the a value of the reactor system. Therefore, this quick measure method is recommendable. The influence caused by energy response of the detector should been taken into account since the measured result reflects the time behavior of group particle. The influence is discussed preliminarily in this paper. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Unbiased Ratio Estimator for k-Eigenvalue in Monte Carlo Criticality Calculations

In criticality calculations, the effective multiplication factor (k{sub eff}) is an important parameter for reactor analysis. It can be interpreted as the ratio of the neutron production rate to the loss rate in a reactor core. In Monte Carlo (MC) criticality calculations, k{sub eff} is obtained for each active cycle i as: k-i = P{sub i}/L{sub i} for I = 1 to I where P{sub i} and L{sub i} are the production rate and the loss rate at cycle i, respectively, and they are normalized by the nominal source size for cycle. Since all neutron particles in a cycle will be absorbed or leaks out at the end, the loss rate, L{sub i}, can be set as the source rate, which is the unity. Thus, in MCNP5, k{sub i} is simply calculated with P{sub i} by using three conventional estimators; collision, absorption, and track-length estimators. In domain decomposed MC criticality calculations based on the fission and surface source (FSS) iteration method, k{sub i} is calculated by a ratio of P{sub i} and L{sub i}, where both P{sub i} and L{sub i} are random variables, sampled by using the same particle histories. When the numerator and the denominator are correlated, the variance of the ratio can be smaller than that of the numerator. Then, the final estimate of k{sub eff} is provided as the sample mean of k{sub i}, which will be referred as 'simple' ratio estimator in this paper. In Ref., it is shown that this ratio estimator converges faster and fluctuates less than the conventional estimator. A similar ratio estimator is also used in Serpent 2, as an implicit estimate of k{sub eff}. However, this type of 'simple' ratio estimator is biased, which means that the expectation of the ratio is different from the ratio of the expectation of the numerator and that of the denominator. In this paper, an unbiased ratio estimator which was originally derived in the cytometry analysis is introduced to estimate k{sub eff} and is tested on a continuous-energy UO{sub 2} pin-cell problem. In this test problem, it is shown that the variance of the unbiased ratio estimator is smaller than those of the conventional estimators provided by MCNP5, while the simple ratio estimator can be significantly biased when the number of histories per cycle is too small. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SCALE Monte Carlo Eigenvalue Methods and New Advancements

SCALE code system is developed and maintained by Oak Ridge National Laboratory to perform criticality safety, reactor analysis, radiation shielding, and spent fuel characterization for nuclear facilities and transportation/storage package designs. SCALE is a modular code system that includes several codes which use either Monte Carlo or discrete ordinates solution methodologies for solving relevant neutral particle transport equations. This paper describes some of the key capabilities of the Monte Carlo criticality safety codes within the SCALE code system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Eigenvalue Uncoupling of Electrokinetic Flows

We present an approach to uncoupling the pair of transient governing equations used in electrokinetics (i.e., streaming potential and electroosmosis). This approach allows for the solution of two uncoupled "intermediate" equations, then the physical solution is found by recombination of these intermediate potentials through a matrix multiplication. We present numerically stable expressions for the coefficients, and an example showing electrokinetics arising from pumping a fully penetrating well in a confined aquifer, surrounded by insulating aquicludes. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. (SAND2019-8712 A)

Kuhlman, Kristopher L↗

Paradeisos: A perfect hashing algorithm for many-body eigenvalue problems

Here, we describe an essentially perfect hashing algorithm for calculating the position of an element in an ordered list, appropriate for the construction and manipulation of many-body Hamiltonian, sparse matrices. Each element of the list corresponds to an integer value whose binary representation reflects the occupation of single-particle basis states for each element in the many-body Hilbert space. The algorithm replaces conventional methods, such as binary search, for locating the elements of the ordered list, eliminating the need to store the integer representation for each element, without increasing the computational complexity. Combined with the “checkerboard” decomposition of the Hamiltonian matrix for distribution over parallel computing environments, this leads to a substantial savings in aggregate memory. While the algorithm can be applied broadly to many-body, correlated problems, we demonstrate its utility in reducing total memory consumption for a series of fermionic single-band Hubbard model calculations on small clusters with progressively larger Hilbert space dimension.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗