Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument

The application of fluorescent crystal media in wide-range X-ray detectors provides an opportunity to directly image the spatial distribution of ultra intense X-ray beams including investigation of the focal spot of free-electron lasers. Here the capabilities of the micro- and nano-focusing X-ray refractive optics available at the High Energy Density instrument of the European XFEL are reported, as measured in situ by means of a LiF fluorescent detector placed into and around the beam caustic. The intensity distribution of the beam focused down to several hundred nanometers was imaged at 9 keV photon energy. A deviation from the parabolic surface in a stack of nanofocusing Be compound refractive lenses (CRLs) was found to affect the resulting intensity distribution within the beam. Comparison of experimental patterns in the far field with patterns calculated for different CRL lens imperfections allowed the overall inhomogeneity in the CRL stack to be estimated. The precise determination of the focal spot size and shape on a sub-micrometer level is essential for a number of high energy density studies requiring either a pin-size backlighting spot or extreme intensities for X-ray heating.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

U.S. Electronic Neutron Generator Use in Research and Academia – A Survey [Slides]

This is a slide deck intended for use at the upcoming IAEA workshop "EVT2002488 Consultancy Meeting on Industrial Applications of Nucleonic Control Systems based on Neutrons from sealed sources and generators". This slide deck provides a survey of U.S. commercial neutron generator technology, including manufacturers, and a few examples of use in academia, and some prior research at INL. All data and figures in this presentation are either publicly available (note citations) or are INL materials that have been previously release through STISM for public presentations or papers.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Electronic Bottleneck Suppression in Next‐Generation Networks with Integrated Photonic Digital‐to‐Analog Converters

Digital‐to‐analog converters (DAC) are indispensable functional units in signal processing instrumentation and wide‐band telecommunication links for both civil and military applications. As photonic systems are capable of high data throughput and low latency, an increasingly found system limitation stems from the required domain crossing such as digital to analog and electronic to optical. A photonic DAC implementation, in contrast, enables a seamless signal conversion with respect to both energy efficiency and short signal delay, often requiring bulky discrete optical components and electric–optic transformation, hence introducing inefficiencies. Herein, a novel coherent parallel photonic DAC concept along with a 4‐bit experimental prototype capable of performing this DAC without optic–electric–optic domain crossing is introduced. This new paradigm guarantees a linear intensity weighting among bits when operating at high sampling rates (50 GHz), featuring an exceptional sampling efficiency (> 100 GS ) and small footprint (≈1 mm 2 ) in an 8‐bit implementation. Importantly, this photonic DAC enables seamless interfaces of next‐generation data processing hardware with high relevance in data centers, task‐specific compute accelerators such as neuromorphic engines, and network edge processing applications.

Meng, Jiawei↗

Toward Å-fs-meV Resolution in Electron Microscopy: Systematic Simulation of the Temporal Spread of Single-Electron Packets

Though efforts to improve the temporal resolution of transmission electron microscopes (TEMs) have waxed and waned for decades, with relatively recent advances routinely reaching sub-picosecond scales, fundamental and practical challenges have hindered the advance of combined Å-fs-meV resolutions, particularly for core-loss spectroscopy and real-space imaging. This is due in no small part to the complexity of the approach required to access timescales upon which electrons, atoms, molecules, and materials first begin to respond and transform – attoseconds to picoseconds. Here we present part of a larger effort devoted to systematically mapping the instrument parameter space of a TEM modified to reach ultrafast timescales. With General Particle Tracer, we studied the statistical temporal distributions of single-electron packets as a function of various fs pulsed-laser parameters and electron-gun configurations and fields for the exact architecture and dimensions of a Thermo Fisher Tecnai Femto ultrafast electron microscope. We focused on easily-adjustable parameters, such as laser pulse duration, laser spot size, photon energy, Wehnelt aperture diameter, and photocathode size. In addition to establishing trends and dispersion behaviors, we identify regimes within which packet duration can be 100s of fs and approach the 300-fs laser limit employed here. Overall, the results provide a detailed picture of the temporal behavior of single-electron packets in the Tecnai Femto gun region, forming the initial contribution of a larger effort.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theories derived from Haissinski equation and their applications to electron storage rings

As a stationary solution of the Vlasov–Fokker–Planck equation, the Haissinski equation predicts the equilibrium line density of a bunch that circulates in a storage ring for a given wake function. The research in this paper shows that some equations regarding the centroid shift of the bunch, the peak position of the bunch profile, bunch length, and the impedance from the bunch profile can be derived from the Haissinski equation in a self-consistent manner. Specifically, a generalized quadratic equation for potential-well bunch lengthening is derived to accommodate any arbitrary impedance model (that is, the impedance spectrum under consideration can take any form). This expands upon Zotter's cubic equation, which is primarily applicable to inductive impedance. The equations derived in this paper are tested using computed impedance models for some electron storage rings, showing machine-dependent properties of impedance effects. We conclude that these equations can be employed in electron storage rings to effectively bridge the gap between impedance computations and beam-based measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scaling and merging time-resolved pink-beam diffraction with variational inference

Time-resolved x-ray crystallography (TR-X) at synchrotrons and free electron lasers is a promising technique for recording dynamics of molecules at atomic resolution. While experimental methods for TR-X have proliferated and matured, data analysis is often difficult. Extracting small, time-dependent changes in signal is frequently a bottleneck for practitioners. Recent work demonstrated this challenge can be addressed when merging redundant observations by a statistical technique known as variational inference (VI). However, the variational approach to time-resolved data analysis requires identification of successful hyperparameters in order to optimally extract signal. In this case study, we present a successful application of VI to time-resolved changes in an enzyme, DJ-1, upon mixing with a substrate molecule, methylglyoxal. We present a strategy to extract high signal-to-noise changes in electron density from these data. Furthermore, we conduct an ablation study, in which we systematically remove one hyperparameter at a time to demonstrate the impact of each hyperparameter choice on the success of our model. We expect this case study will serve as a practical example for how others may deploy VI in order to analyze their time-resolved diffraction data.

47 OTHER INSTRUMENTATION↗

A 100-Mrad (Si) JFET-based Sensing and Communications System for Extreme Nuclear Instrumentation Environments

Dry cask storage is one of two storage methods approved by the U.S. Nuclear Regulatory Commission for spent fuel after removal from reactor cores. Dry casks consist of a stainless steel canister enclosed in a concrete overpack to contain the hazardous radioactive spent fuel rods and provide radiation shielding. Monitoring spent fuel storage casks is desired to ensure the safe containment of the enclosed spent fuel, but is very difficult due to the related harsh temperature and radiation environment. The sensors and associated electronics to monitor temperature, pressure, and/or radiation need to survive high temperatures and radiation doses for extended time periods. For this reason, there is a severe need for radiation-hardened electrical systems that survive well beyond the existing capabilities of commercially available radiation-rated electronic components, which have primarily been developed for space applications. Junction-gate field-effect transistor (JFET) devices are inherently radiation hardened [exceeding 100 Mrad (Si)]. Additionally, when JFETs are used as building blocks for sensing and communication electronics (i.e., oscillators, amplifiers, filters, and mixers), inherently radiation-hardened circuits can be achieved. To this end, JFET-based radiation-hardened electronics interfacing with cask-embedded sensors capable of driving modulated sensor signals through a stainless steel barrier were designed and tested at a dose rate of approximately 500 krad/h (Si) to beyond a 200-Mrad (Si) total ionizing dose. After 200 Mrad (Si), the sensor and communication circuit signals were correctly decoded at the receiver despite oscillator drift. The results from this experiment demonstrate the potential for creating more complex radiation-hardened JFET-based electrical systems for nuclear environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tunable isolated attosecond X-ray pulses with gigawatt peak power from a free-electron laser

The quantum-mechanical motion of electrons in molecules and solids occurs on the sub-femtosecond timescale. Consequently, the study of ultrafast electronic phenomena requires the generation of laser pulses shorter than 1 fs and of sufficient intensity to interact with their target with high probability. Probing these dynamics with atomic-site specificity requires the extension of sub-femtosecond pulses to the soft X-ray spectral region. Here, we report the generation of isolated soft X-ray attosecond pulses with an X-ray free-electron laser. Our source has a pulse energy that is millions of times larger than any other source of isolated attosecond pulses in the soft X-ray spectral region, with a peak power exceeding 100 GW. This unique combination of high intensity, high photon energy and short pulse duration enables the investigation of electron dynamics with X-ray nonlinear spectroscopy and single-particle imaging, unlocking a path towards a new era of attosecond science.

47 OTHER INSTRUMENTATION↗

Forecasting of in situ electron energy loss spectroscopy

Abstract Forecasting models are a central part of many control systems, where high-consequence decisions must be made on long latency control variables. These models are particularly relevant for emerging artificial intelligence (AI)-guided instrumentation, in which prescriptive knowledge is needed to guide autonomous decision-making. Here we describe the implementation of a long short-term memory model (LSTM) for forecasting in situ electron energy loss spectroscopy (EELS) data, one of the richest analytical probes of materials and chemical systems. We describe key considerations for data collection, preprocessing, training, validation, and benchmarking, showing how this approach can yield powerful predictive insight into order-disorder phase transitions. Finally, we comment on how such a model may integrate with emerging AI-guided instrumentation for powerful high-speed experimentation.

36 MATERIALS SCIENCE↗

Implementation of a Talbot–Lau x-ray deflectometer diagnostic platform for the OMEGA EP laser

A Talbot–Lau X-ray Deflectometer (TXD) was implemented in the OMEGA EP laser facility to characterize the evolution of an irradiated foil ablation front by mapping electron densities >10 22 cm -3 by means of Moiré deflectometry. The experiment used a short-pulse laser (30–100 J, 10 ps) and a foil copper target as an x-ray backlighter source. In the first experimental tests performed to benchmark the diagnostic platform, grating survival was demonstrated and x-ray backlighter laser parameters that deliver Moiré images were described. Finally, the necessary modifications to accurately probe the ablation front through TXD using the EP-TXD diagnostic platform are discussed.

36 MATERIALS SCIENCE↗

Inverter Reliability Estimation for Advanced Inverter Functionality

In the near future, grid operators are expected to regularly use advanced distributed energy resource (DER) functions, defined in IEEE 1547-2018, to perform a range of grid-support operations. Many of these functions adjust the active and reactive power of the device through commanded or autonomous modes, which will produce new stresses on the grid-interfacing power electronics components, such as DC/AC inverters. In previous work, multiple DER devices were instrumented to evaluate additional component stress under multiple reactive power setpoints. We utilize quasi-static time-series simulations to determine voltage-reactive power mode (volt-var) mission profile of inverters in an active power system. Mission profiles and loss estimates are then combined to estimate the reduction of the useful life of inverters from different reactive power profiles. It was found that the average lifetime reduction was approximately 0.15% for an inverter between standard unity power factor operation and the IEEE 1547 default volt-var curve based on thermal damage due to switching in the power transistors. For an inverter with an expected 20-year lifetime, the 1547 volt-var curve would reduce the expected life of the device by 12 days. This framework for determining an inverter's useful life from experimental and modeling data can be applied to any failure mechanism and advanced inverter operation.

component degradation↗

Snowmass2021 Topical Group Report from AF07: Targets and Sources

For the next multi-megawatt accelerator generation, targets and other beam-intercepting components will face even more severe challenges due to the higher power densities, higher energy, and higher radiation. A comprehensive research and development program must be implemented to address the challenges. International collaborations such as RaDIATE or High Power Targetry Workshop should be leveraged and expanded to accelerate knowledge gain and avoid duplicated efforts. The next generation of high power targets will need novel designs allowing better high heat flux cooling methods, novel materials, advanced simulations, and better instrumentation. Four main R&D tracks were identified and discussed for targets. For electron sources, current state of art and challenges we are facing for key components such as cathodes, guns and injector design for sources R&D are presented for highly polarized electrons and unpolarized high current high brightness beams. For ion sources such as electron cyclotron resonance ion source (ECRIS), laser ion source (LIS), charge breeders, status of development are reviewed, and areas require investment for future R&D are discussed separately. Facilities critical for various source development are recommended.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors II: Application to Calibration Single-Pulse Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. From first principles, we have derived the perturbation to BPM measurements due to this effect. The theoretical framework was used to design an algorithm for signal correction that does not require knowledge of the time history of the magnetic flux being measured. Corrected signals based on that process compared favorably with the know reference signals in a laboratory calibration test sequence.

43 PARTICLE ACCELERATORS↗

Neutral gas analysis for JET DT operation

Neutral gas analysis, the measurement and evaluation of total and partial pressures, is a key technique to study the impact of neutral gas dynamics on retention, recycling and release processes of fuel or impurity species in fusion devices. At JET, the experiment closest to ITER in terms of operating parameters and size, various detectors and techniques for partial pressure and total pressure measurements are deployed together to characterise neutral gas dynamics during and after plasma operation on various toroidal and poloidal locations. An extensive modification of JET's sub-divertor neutral gas diagnostic system aims at retaining and extending established measurement capabilities in the forthcoming Deuterium-Tritium (DT) experiments (DTE2). To achieve DT compatibility, a separation of radiation-sensitive electronics from the sensor and adequate radiation shielding is required, as well as utilisation of a DT compatible differential pumping system with adjustable throughput to account for the strong pressure variation in the sub-divertor region. Finally, the sub-divertor neutral gas diagnostic will be equipped with multiple Residual Gas Analysers (RGAs), utilising quadrupole mass spectrometry and electrostatic ion-trap-principles, all operating with remote electronics located behind the biological radiation shield. These RGAs will record data in a fast selected discrete mass mode during plasma pulses (cycle ~2 s) and will automatically switch back to continuous data recording (cycle ~100 s) afterwards. They will be complemented by a newly improved Penning gauge spectroscopy configuration in particular supporting the He and D 2 separation relevant for DT operation. The distance between these devices and their associated control unit is typically 15m . A newly developed RGA with a cable length of 80 m, compatible with the ITER environment, will also be employed for the first time. Finally, this set-up and its operation in DTE2 will provide vital input to the development of the ITER divertor RGA in the most relevant environment currently available.

47 OTHER INSTRUMENTATION↗

Characterization of dissipative regions of a N-doped superconducting radio-frequency cavity

We report radio-frequency measurements of quality factors and temperature mapping of a nitrogen doped Nb superconducting RF cavity. Cavity cutouts of hot and cold spots were studied with low temperature scanning tunneling microscopy and spectroscopy, X-ray photoelectron spectroscopy and secondary electron microscopy. Temperature mapping revealed a substantial reduction of the residual resistance upon cooling the cavity with a greater temperature gradient and hysteretic losses at the quench location, pointing to trapped vortices as the dominant source of residual surface resistance. Analysis of the tunneling spectra in the framework of a proximity effect theory shows that hot spots have a reduced pair potential and a wider distribution of the contact resistance between the Nb and the top Nb oxide. Alone, these degraded superconducting properties account for a much weaker excess dissipation as compared with the vortex contribution. Based on the correlation between the quasiparticle density of states and temperature mapping, we suggest that degraded superconducting properties may facilitate vortex nucleation or settling of trapped flux during cooling the cavity through the critical temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preparing Lamellae from Vitreous Biological Samples using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography

Presented here is a protocol for preparing cryo-lamellae from plunge-frozen grids of Plasmodium falciparum-infected human erythrocytes, which could easily be adapted for other biological samples. The basic principles for preparing samples, milling, and viewing lamellae are common to all instruments and the protocol can be followed as a general guide to on-grid cryo-lamella preparation for cryo-electron microscopy (cryoEM) and cryo-electron tomography (cryoET). Electron microscopy grids supporting the cells are plunge-frozen into liquid nitrogen-cooled liquid ethane using a manual or automated plunge freezer, then screened on a light microscope equipped with a cryo-stage. Frozen grids are transferred into a cryo-scanning electron microscope equipped with a focused ion beam (cryoFIB-SEM). Grids are routinely sputter coated prior to milling, which aids dispersal of charge build-up during milling. Alternatively, an e-beam rotary coater can be used to apply a layer of carbon-platinum to the grids, the exact thickness of which can be more precisely controlled. Once inside the cryoFIB-SEM an additional coating of an organoplatinum compound is applied to the surface of the grid via a gas injection system (GIS). This layer protects the front edge of the lamella as it is milled, the integrity of which is critical for achieving uniformly thin lamellae. Regions of interest are identified via SEM and milling is carried out in a step-wise fashion, reducing the current of the ion beam as the lamella reaches electron transparency, in order to avoid excessive heat generation. A grid with multiple lamellae is then transferred to a transmission electron microscope (TEM) under cryogenic conditions for tilt-series acquisition. A robust and contamination-free workflow for lamella preparation is an essential step for downstream techniques, including cellular cryoEM, cryoET, and sub-tomogram averaging. Development of these techniques, especially for lift-out and milling of high-pressure frozen samples, is of high-priority in the field.

59 BASIC BIOLOGICAL SCIENCES↗

Statistical analysis of non-Maxwellian electron distribution functions measured with angularly resolved Thomson scattering

Angularly resolved Thomson scattering is a novel extension of Thomson scattering, enabling the measurement of the electron velocity distribution function over many orders of magnitude. Here, details of the theoretical basis of the technique and the instrument designed for this measurement are described. Angularly resolved Thomson-scattering data from several experiments are shown with descriptions of the corresponding distribution functions. A reduced model describing the distribution function is given and used to perform a Monte Carlo analysis of the uncertainty in the measurements. The electron density and temperature were determined to a precision of 12% and 21%, respectively, on average, while all other parameters defining the distribution function were generally determined to better than 20%. It was found that these uncertainties were primarily due to limited signal to noise and instrumental effects. Furthermore, measurements with this level of precision were sufficient to distinguish between Maxwellian and non-Maxwellian distribution functions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗