Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy programs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The "Apollo" of Aeronautics: NASA's Aircraft Energy Efficiency Program, 1973-1987

In fall 1975, 10 distinguished United States Senators from the Aeronautical and Space Sciences Committee summoned a group of elite aviation experts to Washington, DC. The Senators were holding hearings regarding the state of the American airline industry, which was struggling in the wake of the 1973 Arab oil embargo and the dramatically increasing cost of fuel. Providing testimony were presidents or vice presidents of United Airlines, Boeing, Pratt & Whitney, and General Electric. Other witnesses included high-ranking officials from the National Aeronautics and Space Administration (NASA), the U.S. Air Force, and the American Institute of Aeronautics and Astronautics. Their Capitol Hill testimony painted a bleak economic picture, described in phrases that included immediate crisis condition, long-range trouble, serious danger, and economic dislocation.

Aircraft↗

Incorporating two-dimensional conduction modeling techniques into an energy simulation program: The EnergyPlus radiant system example

Due to the inherent complexity of multi-dimensional solutions for transient conduction in a multilayered building element, most heat balance-based algorithms assume that conduction occurs only in one dimension—through the building element between the inside and outside environments. Usually, since the length and width of the elements are much greater than the thickness of the element, this is a valid assumption. However, there are some cases such as hydronic radiant slabs where this assumption may not lead to an accurate estimate of the energy consumption of the system. In a hydronic radiant slab, water tubes are embedded in a slab, and hot or chilled water is circulated to meet any heating or cooling loads. The energy consumption of such a system will depend highly on the temperature of the water being sent to the slab (i.e., produced by the boiler or chiller). The temperature of the water that must be sent to the slab will depend on the spacing of the tubes, the multilayer construction of the building element, and the boundary conditions to which the construction is exposed. Thus, to accurately predict the energy consumption of such a system, a transient two-dimensional heat conduction model must be integrated with a heat balance-based simulation. This paper demonstrates the potential loss of accuracy associated with the one-dimensional radiant system models by providing a comparison of one- and two-dimensional solutions using EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing and Expertise for Marine Energy (TEAMER) Program Support - Numerical Modeling Assistance for iProTech's "PIP" WEC Device: Cooperative Research and Development Final Report, CRADA Number CRD-20-17303

Develop a time-domain, 3 degree of freedom numerical model of IProTech's PIP device, including power take-off (PTO), that can be used to develop control algorithms and establish a baseline technology performance level (TPL). This is important to IProTech because having a good numerical model allows IProTech to optimize design and control algorithms on an ongoing basis. A baseline TPL enables the PIP technology to be benchmarked against other wave energy converter (WEC) concepts, providing (i) justification (or not) for investment in wave tank model testing, (ii) identifying optimum design parameters and control algorithms for the test model, (iii) specifying test conditions and (iv) interpreting wave tank test results. An accredited WEC-Sim model of the PIP device is an essential tool for further development of the technology. 1) The development of numerical models of the PIP concept will enable iProTech to evaluate the potential performance of this concept, and to investigate how sensitive the device is to different variables within the system (e.g. hydraulic components, geometry dimensions, etc.) 2) The numerical models were developed with WEC-Sim and PTO-Sim -- the de-facto industry standard WEC numerical modeling tools. A detailed model of the system's hydraulic circuit was developed with PTO-Sim. However, WEC-Sim is based on linear hydrodynamics and has several limitations; validation against high fidelity models/physical scale models would help to build confidence in the results.

16 TIDAL AND WAVE POWER↗

The DOE photovoltaics program

As part of the National Solar Energy program, the US Department of Energy is now engaged in the development of technically feasible, low cost candidate component and system technologies to the point where technical readiness can be demonstrated by 1982. The overall strategy is to pursue parallel options that continue to show promise of meeting the program goals, thus increasing the probability that at least one technology will be successful. Included in technology development are both flat plate solar collectors and concentrator solar collectors, as well as the balance of system components, such as structures, power conditioning, power controls, protection, and storage. Generally, these last items are common to both flat plate and concentrator systems, but otherwise there is considerable disparity in design philosophy, photovoltaic cell requirements, and possible applications between the two systems. Objectives for research activities at NASA Lewis for stand alone applications, and at Sandia Laboratories where intermediate load center applications are addressed, are highlighted as well as college projects directed by Oak Ridge National Laboratory, and international applications managed by the Solar Energy Research Institute. Joint DOD/DOE effects for military applications are also summarized.

Ferber, R. R.↗

Keys to the House: Unlocking Residential Savings With Program Models for Home Energy Upgrades

After more than 40 years of effort, energy efficiency program administrators and associated contractors still find it challenging to penetrate the home retrofit market, especially at levels commensurate with state and federal goals for energy savings and emissions reductions. Residential retrofit programs further have not coalesced around a reliably successful model. They still vary in design, implementation and performance, and they remain among the more difficult and costly options for acquiring savings in the residential sector. If programs are to contribute fully to meeting resource and policy objectives, administrators need to understand what program elements are key to acquiring residential savings as cost effectively as possible. To that end, the U.S. Department of Energy (DOE) sponsored a comprehensive review and analysis of home energy upgrade programs with proven track records, focusing on those with robustly verified savings and constituting good examples for replication. The study team reviewed evaluations for the period 2010 to 2014 for 134 programs that are funded by customers of investor-owned utilities. All are programs that promote multi-measure retrofits or major system upgrades. We paid particular attention to useful design and implementation features, costs, and savings for nearly 30 programs with rigorous evaluations of performance. This meta-analysis describes program models and implementation strategies for (1) direct install retrofits; (2) heating, ventilating and air-conditioning (HVAC) replacement and early retirement; and (3) comprehensive, whole-home retrofits. We analyze costs and impacts of these program models, in terms of both energy savings and emissions avoided. These program models can be useful guides as states consider expanding their strategies for acquiring energy savings as a resource and for emissions reductions. We also discuss the challenges of using evaluations to create program models that can be confidently applied in multiple jurisdictions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Early Performance Results for Massachusetts Homes in the National Grid Pilot Deep Energy Retrofit Program

In 2009, National Grid started a DER pilot program that offered technical support and financial incentives to qualified Massachusetts homeowners who planned and successfully completed a retrofit that incorporated the performance requirements and goals of the National Grid DER measures package. This DER measures package, developed through collaboration with Building Science Corporation (BSC), includes specific thermal and airtightness goals for the enclosure components as well as health, safety, durability, and indoor air quality requirements. By providing measures that can be included with common renovation activities such as roof replacement, window replacement, re-siding, basement remediation, and remodeling, this DER measures package is expected to have widespread application for existing homes in the New England area. The post-retrofit performance and cost ranges provided by this research project can provide concrete input for homeowners who are considering a DER. Field test data available for air tightness measured using blower door test. House 1 - Address Belchertown, MA 01007, Notes: Energy Savings: 75%, Company: Clark House 2-1 and 2 - Address (1) Brownsberger, MA 02478 and (2) Belmont, MA 02478, Notes Energy Savings: 73%, Company: Brownsberger House 3 - Address Millbury, MA 01527, Notes Energy Savings: 31%, Company: Tweedly House 4 - Address Milton, MA 02186 Notes Energy Savings: 42%, Company: Koh House 5 - Address Quincy, MA 02169, Notes Energy Savings: 57%, Company: Hall House 6-1 and 2 - Address Arlington, MA 02476, Notes Energy Savings: 55%, Company: Venable-Hwang House 7 - Address Newton, MA 02459, Notes Energy Savings: 42%, Company: Lavine House 8-1, 2, and 3 - Address Jamaica Plain, MA 02130, Notes Energy Savings: 43%, Company: Buhs House 9 - Address Northampton, MA 01060, Notes Energy Savings: 49%, Company: Wick House 10 - Address Lancaster, MA 01523, Notes Energy Savings: 40%, Company: Habitat for Humanity of North Central Massachusetts House 11 - Address Brookline, MA 02445, Notes Energy Savings: 27%, Company: Aquiline House 12 - Address Westford, MA 01886, Notes Energy Savings: 30%, Company: Atkins House 13 - Address Gloucester, MA 01930, Notes Energy Savings: 35%, Company: Cunningham

airtightness↗

Nuclear Energy Infrastructure Database Fitness and Suitability Review

In 2014, the Deputy Assistant Secretary for Science and Technology Innovation (NE-4) initiated the Nuclear Energy-Infrastructure Management Project by tasking the Nuclear Science User Facilities (NSUF) to create a searchable and interactive database of all pertinent NE supported or related infrastructure. This database will be used for analyses to establish needs, redundancies, efficiencies, distributions, etc. in order to best understand the utility of NE’s infrastructure and inform the content of the infrastructure calls. The NSUF developed the database by utilizing data and policy direction from a wide variety of reports from the Department of Energy, the National Research Council, the International Atomic Energy Agency and various other federal and civilian resources. The NEID contains data on 802 R&D instruments housed in 377 facilities at 84 institutions in the US and abroad. A Database Review Panel (DRP) was formed to review and provide advice on the development, implementation and utilization of the NEID. The panel is comprised of five members with expertise in nuclear energy-associated research. It was intended that they represent the major constituencies associated with nuclear energy research: academia, industry, research reactor, national laboratory, and Department of Energy program management. The Nuclear Energy Infrastructure Database Review Panel concludes that the NSUF has succeeded in creating a capability and infrastructure database that identifies and documents the major nuclear energy research and development capabilities across the DOE complex. The effort to maintain and expand the database will be ongoing. Detailed information on many facilities must be gathered from associated institutions added to complete the database. The data must be validated and kept current to capture facility and instrumentation status as well as to cover new acquisitions and retirements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Appliances

This study characterizes and assesses the appliances used in commercial buildings. The primary objectives of this study were to document the energy consumed by commercial appliances and identify research, development and demonstration (RD&D) opportunities for efficiency improvements, excluding product categories such as HVAC, building lighting, refrigeration equipment, and distributed generation systems. The study included equipment descriptions, characteristics of the equipment’s market, national energy consumption, estimates of technical potential for energy-saving technologies, and recommendations for U.S. Department of Energy programs that can promote energy savings in commercial appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oppenheimer Science and Energy Leadership Program (OSELP) Simulation and Computation at LANL [Slides]

Simulation and Computation plays a pivotal role in maintaining confidence in the stockpile as the approach to underwrite that confidence has changed. The need for resolution and fidelity at scale drives our need for increased computing capability. DOE/NNSA Advanced Simulation and Computing (ASC) program provides the computational surrogate for testing. ASC provides simulation-based confidence in the U.S. stockpile.

97 MATHEMATICS AND COMPUTING↗

Oppenheimer Science and Energy Leadership Program (OSELP) Software and Computing Strategy for the Future of Weapons Physics Applications [Slides]

Mission drivers at the national level are evolving to accommodate a broadening landscape. The U.S. faces a rapidly evolving, threat-based environment with an associated expansion of national-level priorities. Priorities continue to include all aspects of sustaining the existing, aging stockpile. Now, however, we must also include consideration of options for a future deterrent, including efficacy of the deterrent against new threats (threat assessment and response), capability needs associated with new materials and modern manufacturing and production processes, and efficiency requirements for a modern workflow for weapons design. Executing this complex strategy will come with challenges. We must execute our current mission, while we prepare for future missions and an increasingly uncertain future.

42 ENGINEERING↗