Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Experimental studies of the separated flow over a NASA GA(W)-1 airfoil

The separated flow over the 17-percent-thick blunt-trailing-edge NASA GA(W)-1 airfoil is investigated experimentally at angles of attack 10.3-18.4 deg and velocities up to 92 m/sec in the 1.09 x 0.76 x 1.22-m working section of a closed-circuit wind tunnel, with typical Reynolds numbers of the order 4 x 10 to the 6th. The results are presented graphically and characterized. Separated-flow velocity profiles and skin-friction distributions are obtained, and the boundary-layer integral properties are shown to be in good agreement with the separation criteria of Sandborn and Kline (1961). The chordwise development of the mean velocity is reduced to a universal curve, and some similarity is found in the outer-region velocity profiles downstream of the separation.

Mehta, J. M.↗

Shock-implanted noble gases. II - Additional experimental studies and recognition in naturally shocked terrestrial materials

The process by which ambient gases can be implanted into silicates by shocks was investigated by analyzing the noble-gas content of several experimentally and naturally shocked silicate samples. The retentivity of shock-implanted gas during stepwise heating in the laboratory was defined in terms of two parameters, namely, the activation energy for diffusion and the extraction temperature at which 50 percent of the gas is released, both of which correlate with the shock pressure. The experiments indicate that, with increasing shock pressure, gas implantation occurs through an increasing production of microcracks/defects in the silicate lattice. The degree of annealing of these defects control the degree of diffusive loss of implanted gas.

Bogard, Donald↗

Experimental study of boundary layer transition on a heated flat plate

A detailed investigation to the document momentum and thermal development of boundary layers undergoing natural transition on a heated flat plate was performed. Experimental results of both overall and conditionally sampled characteristics of laminar, transitional, and low Reynolds number turbulent boundary layers are presented. Measurements were done in a low-speed, closed-loop wind tunnel with a freestream velocity of 100 ft/s and zero pressure gradient over a range of freestream turbulence intensities from 0.4 to 6 percent. The distributions of skin friction, heat transfer rate, and Reynolds shear stress were all consistent with previously published data. Reynolds analogy factors for momentum thickness Reynolds number, Re(sub theta) less than 2300 were found to be well predicted by laminar and turbulent correlations which accounted for an unheated starting length and uniform heat flux. A small dependence of turbulence results on the freestream turbulence intensity was observed.

Sohn, K. H.↗

Experimental study of boundary layer transition on a heated flat plate

A detailed investigation to the document momentum and thermal development of boundary layers undergoing natural transition on a heated flat plate was performed. Experimental results of both overall and conditionally sampled characteristics of laminar, transitional, and low Reynolds number turbulent boundary layers are presented. Measurements were done in a low-speed, closed-loop wind tunnel with a freestream velocity of 100 ft/s and zero pressure gradient over a range of freestream turbulence intensities from 0.4 to 6 percent. The distributions of skin friction, heat transfer rate, and Reynolds shear stress were all consistent with previously published data. Reynolds analogy factors for momentum thickness Reynolds number, Re(sub theta) less than 2300 were found to be well predicted by laminar and turbulent correlations which accounted for an unheated starting length and uniform heat flux. A small dependence of turbulence results on the freestream turbulence intensity was observed.

Sohn, K. H.↗

Experimental Study of the Low Supersaturation Nucleation in Crystal Growth by Contactless Physical Vapor Transport

The process of the development of the nuclei and of subsequent seeding in 'contactless' physical vapor transport is investigated experimentally. Consecutive stages of the Low Supersaturation Nucleation in 'contactless' geometry for growth of CdTe crystals from the vapor are shown. The effects of the temperature field, geometry of the system, and experimental procedures on the process are presented and discussed. The experimental results are found to be consistent with our earlier numerical modeling results.

Grasza, K.↗

Experimental study of two separating turbulent boundary layers

A detailed study of two strong adverse pressure gradient flows, one with a free-stream velocity of 35 m/sec, at throat (producing a Re sub theta of 27000 at detachment) and another with free-stream velocity of 22 m/sec, at throat (producing a Re sub theta of 19000 at detachment) is presented. In these examples flows separate slowly and reattach very rapidly over a very short distance in a streamwise direction. In the backflow region, there appears to be a semi-logarithmically flat region in the streamwise fluctuating velocity component, u', which spreads over a definite range of y/delta. In power spectra, the flow variables phi sub upsilon upsilon (kappa sub 1 delta)/ -uv bar sub max vs. kappa sub 1 delta forms a unique set of scaling parameters for adverse pressure gradient flows. Experimental results show good agreement with previous studies.

Nagabushana, K. A.↗

Experimental study of flow reattachment in a single-sided sudden expansion

The reattachment of a fully turbulent, two dimensional, separated shear layer downstream of a single-sided sudden expansion in a planar duct flow was examined experimentally. The importance of changing the structure of the separated shear layer on the reattachment process itself was examined. For all cases, the Reynolds number based on step height was greater than 20,000, the expansion ratio was 5/3, and the inlet boundary layer was less than one-half step height in thickness. A crucially important phase was the development of a pulsed wall probe for measurement of skin friction in the reattachment region, thus providing an unambiguous definition of the reattachment length. Quantitative features of reattachment - including streamwise development of the mean and fluctuating velocity field, pressure rise, and skin friction - were found to be similar for all cases studied when scaled by the reattachment length. A definition of the reattachment zone is proposed.

Westphal, R. V.↗

Towards Principled Experimental Study of Autonomous Mobile Robots

We review the current state of research in autonomous mobile robots and conclude that there is an inadequate basis for predicting the reliability and behavior of robots operating in unengineered environments. We present a new approach to the study of autonomous mobile robot performance based on formal statistical analysis of independently reproducible experiments conducted on real robots. Simulators serve as models rather than experimental surrogates. We demonstrate three new results: 1) Two commonly used performance metrics (time and distance) are not as well correlated as is often tacitly assumed. 2) The probability distributions of these performance metrics are exponential rather than normal, and 3) a modular, object-oriented simulation accurately predicts the behavior of the real robot in a statistically significant manner.

Object-Oriented Simulation↗

Ground effect for V/STOL aircraft configurations and its simulation in the wind tunnel. Part 2: Experimental studies

Wind tunnel tests on a finite, knee-blowing-flapped wing and on a direct jet lift configuration were performed in a 30 x 42 inch wind tunnel. The objectives of these tests were, in experimental order:(1) to obtain definitive fixed-versus-moving ground comparisons on a powered, high-lift finite wing and on a lifting jet configuration as a function of model height and lift, (2) to understand the flow mechanism which lead to observed differences between moving and fixed-ground results, (3) to discover whether the above effects of a moving ground plane can be simulated by tangential-blowing boundary layer control at the wind tunnel floor, and (4) to check the form and the numerical constants for the wall jet blowing equation derived theoretically in Part I of this report. This relates wall jet blowing quantities to model lift coefficient.

Hackett, J. E.↗

Experimental study of boundary layer transition with elevated freestream turbulence on a heated flat plate

A detailed investigation to document momentum and thermal development of boundary layers undergoing natural transition on a heated flat plate was performed. Experimental results of both overall and conditionally sampled characteristics of laminar, transitional, and low Reynolds number turbulent boundary layers are presented. Measurements were acquired in a low-speed, closed-loop wind tunnel with a freestream velocity of 100 ft/s and zero pressure gradient over a range of freestream turbulence intensities (TI) from 0.4 to 6 percent. The distributions of skin friction, heat transfer rate and Reynolds shear stress were all consistent with previously published data. Reynolds analogy factors for R(sub theta) is less than 2300 were found to be well predicted by laminar and turbulent correlations which accounted for an unheated starting length. The measured laminar value of Reynolds analogy factor was as much as 53 percent higher than the Pr(sup -2/3). A small dependence of turbulent results on TI was observed. Conditional sampling performed in the transitional boundary layer indicated the existence of a near-wall drop in intermittency, pronounced at certain low intermittencies, which is consistent with the cross-sectional shape of turbulent spots observed by others. Non-turbulent intervals were observed to possess large magnitudes of near-wall unsteadiness and turbulent intervals had peak values as much as 50 percent higher than were measured at fully turbulent stations. Non-turbulent and turbulent profiles in transitional boundary layers cannot be simply treated as Blasius and fully turbulent profiles, respectively. The boundary layer spectra indicate predicted selective amplification of T-S waves for TI is approximately 0.4 percent. However, for TI is approximately 0.8 and 1.1 percent, T-S waves are localized very near the wall and do not play a dominant role in transition process.

Sohn, Ki-Hyeon↗

Experimental Study of Torsional Column Failure

Thirty-three 24ST aluminum-alloy 2- by 2- by 0.10-inch channels, with lengths ranging from 10 to 90 inches were tested at Stanford University in compression to obtain an experimental verification of the theoretical formulas for torsional failure developed by Eugene E. Lundquist of the N.A.C.A. The observed critical loads and twist-axis locations were sufficiently close to the values obtained from the formulas to establish the substantial validity of the latter. The differences between observed and computed results were small enough to be accounted for by small and mostly unavoidable differences between actual test conditions and those assumed in deriving the formulas. Some data were obtained from the shorter specimens regarding the growth of the buckles that resulted in local buckling failure.

Nile, Alfred S↗

Analytical and Experimental Study of Near-Threshold Interactions Between Crack Closure Mechanisms

The results of an analytical closure model that considers contributions and interactions between plasticity-, roughness-, and oxide-induced crack closure mechanisms are presented and compared with experimental data. The analytical model is shown to provide a good description of the combined influences of crack roughness, oxide debris, and plasticity in the near-threshold regime. Furthermore, analytical results indicate that closure mechanisms interact in a non-linear manner such that the total amount of closure is not the sum of closure contributions for each mechanism.

Newman, John A.↗

Passive Energy-Saving Solutions for Clothes Dryers: A Modeling and Experimental Study for Improved Efficiency and Affordability

Dryers are integral appliances in modern households, yet their significant power consumption remains a critical challenge for reducing energy bills and upgrades. This work presents the outcomes of a comprehensive investigation aimed at lowering the operating energy costs of the dryer through modeling and experimental approaches. Specifically, the objectives of this research are twofold: (1) to reduce energy consumption without negatively impacting drying performance or time; and (2) to ensure affordability by developing retrofittable solutions characterized by low cost and a quick payback period. These strategies promise universal applicability to all dryer categories, encompassing both gas and electric models, by tackling core issues such as unnecessary heat loss and excess energy supply, both prevalent across dryer designs. Our methodology combines robust modeling frameworks and experimental validation to target energy efficiency improvements through three primary pathways: (1) effective heat loss management using ultralow-cost insulation materials tailored for dryer systems; (2) heat management across the drying cycle, facilitated by passive heat transfer mechanisms, and (3) optimization of heat supply to the load to ensure precise energy delivery, minimizing waste. These innovations are designed to seamlessly integrate with existing dryer configurations, providing a scalable and retrofittable solution that ensures affordability without requiring substantial redesigns or expensive components. Using these methods, the study demonstrates improvement opportunities in dryer energy consumption while maintaining the desired performance. The modeling component utilizes computational simulations to evaluate the thermal and energy performance of these innovations under varied operational conditions, providing foundational insights for experimental design. By addressing critical areas such as heat loss, energy recovery, and supply optimization, this work proposes impactful solutions for lowering the energy costs in domestic clothes dryers. The ultralow-cost, retrofittable nature of the proposed strategies ensures widespread adoption potential across diverse dryer categories, making significant strides toward affordable household energy practices.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

An analytical and experimental study of sound propagation and attenuation in variable-area ducts

The performance of sound suppression techniques in ducts that produce refraction effects due to axial velocity gradients was evaluated. A computer code based on the method of multiple scales was used to calculate the influence of axial variations due to slow changes in the cross-sectional area as well as transverse gradients due to the wall boundary layers. An attempt was made to verify the analytical model through direct comparison of experimental and computational results and the analytical determination of the influence of axial gradients on optimum liner properties. However, the analytical studies were unable to examine the influence of non-parallel ducts on the optimum linear conditions. For liner properties not close to optimum, the analytical predictions and the experimental measurements were compared. The circumferential variations of pressure amplitudes and phases at several axial positions were examined in straight and variable-area ducts, hard-wall and lined sections with and without a mean flow. Reasonable agreement between the theoretical and experimental results was obtained.

Nayfeh, A. H.↗

NdPO 4 solubility and aqueous Neodymium speciation in supercritical fluids: An experimental study at 500–700 °C and 1.7 kbar

A key aspect in the formation of rare earth elements (REE) deposits is the role of REE transport as aqueous REE complexes in supercritical hydrothermal solutions, where the nature of the aqueous complex is controlled by solution composition, temperature and pressure. Despite chloride being considered as one of the most abundant transporting ligands in magmatic-hydrothermal fluids, experimental investigations on the stability of aqueous REE chloride complexes are scarce above 300 °C. In this study, synthetic NdPO 4 crystals were reacted with non-saline and saline (0, 0.05 and 0.5 mNaCl), acidic (0.01 mHCl) aqueous solutions in a series of solubility experiments conducted at 500–700 °C and 1.7 kbar, where the solubilities were determined using a stable Nd isotope ( 145 Nd isotope spike) dilution technique. NdPO 4 solubility ranges between 28 ppm and 10,858 ppm, where solubility increases with both temperature and salinity. At 500 °C, log mNdPO 4 increases from –3.93 to –1.60 and there is a strong correlation between NdPO 4 solubility and NaCl concentrations (slope of 1.2 ± 0.3), indicating stabilization of the Nd chloride aqueous complexes with a stoichiometry corresponding to NdCl 2+ . At 600 °C, this correlation is weaker (slope of 0.4, log mNdPO 4 increases from –2.63 to –1.88) indicating the stabilization of both Nd chloride and hydroxyl species controlling solubility. At 700 °C, NdPO 4 solubility is largely independent of NaCl concentration indicating that solubility is controlled by Nd hydroxyl complexes, where stoichiometry suggests the neutral Nd(OH) 3 0 species is dominant. The solubility product (Ksp) of NdPO4 is derived from experimental data with the relation: log K sp = -41.81 – 0.057T – 20987/T, with T temperature in Kelvin. Comparison of the measured Nd phosphate solubility to thermodynamic predictions using the available Helgeson-Kirkham-Flowers equation of state parameters for aqueous Nd complexes indicate that predictions are up to three orders of magnitude lower compared to experimental observations. This discrepancy is most pronounced in saline solutions, suggesting that thermodynamic properties of the REE chloride species in supercritical fluids require revision. Numerical simulations of fluid-rock interaction between acidic, saline fluids and a Strange Lake felsic mineral assemblage demonstrates that NdPO 4 solubility predictions from models are four to six orders of magnitude lower than those calculated based on empirical fits from experiments, which suggests that acidic, saline fluids may play an important role in mobilizing large amounts of light REE from 450 to 700 °C.

58 GEOSCIENCES↗

Experimental study on boron distribution and transport at plasma-facing components during impurity powder dropping in the Large Helical Device

Toward real-time wall conditioning, impurity powder dropping experiments with boron powder were performed in the 22nd experimental campaign of the Large Helical Device. To examine the deposition and desorption process of boron, we focus on boron hydride (BH) molecules which presumably populate near plasma-facing components. We performed spatially-resolved spectroscopic measurements of emission by boron ions and BH molecules. From the measurement, we found that BH and B + were concentrated on the divertor viewing chord, which suggest boron deposition in the divertor region. By comparing Hγ emissions with and without boron injection, neutral hydrogen shows uniform reduction in the SOL region, whereas less reduction of neutral hydrogen is confirmed in the divertor region. Although emissions from BH and B + increased linearly, emissions by B0 and B4 + became constant after the middle of the discharge. Continuous reduction of carbon density in the core plasma was confirmed even after B 0 and B 4 + became constant. The results may show reduction of hydrogen recycling and facilitation of impurity gettering by boron in the divertor region and thus effective real-time wall conditioning.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effects of energetic proton bombardment on polymeric materials: Experimental studies and degradation models

This report describes 3 MeV proton bombardment experiments on several polymeric materials of interest to NASA carried out on the Tandem Van De Graff Accelerator at the California Institute of Technology's Kellogg Radiation Laboratory. Model aromatic and aliphatic polymers such as poly(1-vinyl naphthalene) and poly(methyl methacrylate), as well as polymers for near term space applications such as Kapton, Epoxy and Polysulfone, have been included in this study. Chemical and physical characterization of the damage products have been carried out in order to develop a model of the interaction of these polymers with the incident proton beam. The proton bombardment methodology developed at the Jet Propulsion Laboratory and reported here is part of an ongoing study on the effects of space radiation on polymeric materials. The report is intended to provide an overview of the mechanistic, as well as the technical and experimental, issues involved in such work rather than to serve as an exhaustive description of all the results.

Coulter, D. R.↗

Experimental study of pressure and heating rate on a swept cylindrical leading edge resulting from swept shock wave interference

The effects of cylindrical leading edge sweep on surface pressure and heat transfer rate for swept shock wave interference were investigated. Experimental tests were conducted in the Calspan 48-inch Hypersonic Shock Tunnel at a nominal Mach number of 8, nominal unit Reynolds number of 1.5 x 10 to the 6th power per foot, leading edge and incident shock generator sweep angles of 0, 15, and 30 deg, and incident shock generator angle-of-attack fixed at 12.5 deg. Detailed surface pressure and heat transfer rate on the cylindircal leading edge of a swept shock wave interference model were measured at the region of the maximum surface pressure and heat transfer rate. Results show that pressure and heat transfer rate on the cylindrical leading edge of the shock wave interference model were reduced as the sweep was increased over the range of tested parameters. Peak surface pressure and heat transfer rate on the cylinder were about 10 and 30 times the undisturbed flow stagnation point value, respectively, for the 0 deg sweep test. A comparison of the 15 and 30 deg swept results with the 0 deg swept results showed that peak pressure was reduced about 13 percent and 44 percent, respectively, and peak heat transfer rate was reduced about 7 percent and 27 percent, respectively.

Glass, Christopher E.↗