Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Method and system for training dynamic nonlinear adaptive filters which have embedded memory

Described herein is a method and system for training nonlinear adaptive filters (or neural networks) which have embedded memory. Such memory can arise in a multi-layer finite impulse response (FIR) architecture, or an infinite impulse response (IIR) architecture. We focus on filter architectures with separate linear dynamic components and static nonlinear components. Such filters can be structured so as to restrict their degrees of computational freedom based on a priori knowledge about the dynamic operation to be emulated. The method is detailed for an FIR architecture which consists of linear FIR filters together with nonlinear generalized single layer subnets. For the IIR case, we extend the methodology to a general nonlinear architecture which uses feedback. For these dynamic architectures, we describe how one can apply optimization techniques which make updates closer to the Newton direction than those of a steepest descent method, such as backpropagation. We detail a novel adaptive modified Gauss-Newton optimization technique, which uses an adaptive learning rate to determine both the magnitude and direction of update steps. For a wide range of adaptive filtering applications, the new training algorithm converges faster and to a smaller value of cost than both steepest-descent methods such as backpropagation-through-time, and standard quasi-Newton methods. We apply the algorithm to modeling the inverse of a nonlinear dynamic tracking system 5, as well as a nonlinear amplifier 6.

Rabinowitz, Matthew↗

Method for providing a polarization filter for processing synthetic aperture radar image data

A polarization filter can maximize the signal-to-noise ratio of a polarimetric SAR and help discriminate between targets or enhance image features, e.g., enhance contract between different types of target. The method disclosed is based on the Stokes matrix/Stokes vector representation, so the targets of interest can be extended targets, and the method can also be applied to the case of bistatic polarimetric radars.

Dubois, Pascale C.↗

A windowed mean trajectory approximation for condensed phase dynamics

We propose a trajectory-based quasi-classical method for approximating dynamics in condensed phase systems. Building upon the previously developed optimized mean trajectory approximation that has been used to compute linear and nonlinear spectra, we borrow some ideas from filtering trajectory methods to obtain a novel semiclassical method for the dynamical propagation of density matrices. This new approximation is tested rigorously against standard multistate electronic models, spin-boson models, and models of the Fenna–Matthews–Olson complex. For dissipative systems, the current method is significantly better or as good as many other semiclassical methods available, especially at low temperatures and for off-diagonal density matrix elements, whereas for scattering models, the current method bears similar limitations as mean-field propagation schemes. All results are tested against the numerically exact hierarchical equations of motion method. In conclusion, the new method shows excellent agreement across various parameter regimes with numerically exact results, highlighting the robustness and accuracy of our approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Role of Scale and Model Bias in ADAPT's Photospheric Estimation

The Air Force Assimilative Photospheric flux Transport model (ADAPT), is a magnetic flux propagation based on Worden-Harvey (WH) model. ADAPT would be used to provide a global photospheric map of the Earth. A data assimilation method based on the Ensemble Kalman Filter (EnKF), a method of Monte Carlo approximation tied with Kalman filtering, is used in calculating the ADAPT models.

58 GEOSCIENCES↗

Method for providing a polarization filter for processing synthetic aperture radar image data

A polarization filter can maximize the signal-to-noise ratio of a polarimetric synthetic aperture radar (SAR) and help discriminate between targets or enhance image features, e.g., enhance contrast between different types of target. The method disclosed is based on the Stokes matrix/ Stokes vector representation, so the targets of interest can be extended targets, and the method can also be applied to the case of bistatic polarimetric radars.

Dubois, Pascale C.↗

SU-F-J-28: Development of a New Imaging Filter to Remove the Shadows From the Carbon Fiber Grid Table Top

Purpose: For the image guided radiation therapy (IGRT), the shadows caused by the construction of the treatment couch top adversely affect the visual evaluation. Therefore, we developed the new imaging filter in order to remove the shadows. The performance of the new filter was evaluated using the clinical images. Methods: The new filter was composed of the band-pass filter (BPF) weighted by the k factor and the low-pass filter (LPF). In the frequency region, the stop bandwidth were 8.3×10{sup 3} mm{sup −1} on u direction and 11.1×10{sup 3} mm{sup −1} on v direction for the BPF, and the pass bandwidth were 8.3×10{sup 3} mm{sup −1} on u direction and 11.1×10{sup 3} mm{sup −1} on v direction for the LPF. After adding the filter, the shadows from the carbon fiber grid table top (CFGTT, Varian) on the kV-image was removed. To check the filter effect, we compared the clinical images, which are thorax and thoracoabdominal region, with to without the filter. The subjective evaluation tests was performed by adapting a three-point scale (agree, neither agree nor disagree, disagree) about the 15 persons in the department of radiation oncology. Results: We succeeded in removing all shadows of CFGTT using the new filter. This filter is very useful shown by the results of the subjective evaluation having the 23/30 persons agreed to the filtered clinical images. Conclusion: We concluded that the proposed method was useful tool for the IGRT and the new filter leads to improvement of the accuracy of radiation therapy.

60 APPLIED LIFE SCIENCES↗

Different methods of reconstructing spectra from filtered x-ray diode measurements

Filtered x-ray diodes, sensitive in different spectral regions, are used to measure the emission spectrum of laser-driven hohlraums at the Omega laser facility in Rochester, NY. Here we present two new methods to reconstruct the emission spectra from the response of the x-ray diodes and compare them to the method currently used to extract a spectrum and a temperature in the hohlraum. We also use simulated spectra to characterize the different methods with respect to uncertainty, emission temperature, and the ability to reconstruct the input spectrum as closely as possible.

07 ISOTOPE AND RADIATION SOURCES↗

CVS Decomposition of 3D Homogeneous Turbulence Using Orthogonal Wavelets

This paper compares the filtering used in Coherent Vortex Simulation (CVS) decomposition with an orthogonal wavelet basis, with the Proper Orthogonal Decomposition (POD) or Fourier filtering. Both methods are applied to a field of Direct Numerical Simulation (DNS) data of 3D forced homogeneous isotropic turbulence at microscale Reynolds number R(sub lambda) = 168. We show that, with only 3%N retained modes, CVS filtering separates the coherent vortex tubes from the incoherent background flow. The latter is structureless, has an equipartition energy spectrum, and has a Gaussian velocity probability distribution function (PDF) and an exponential vorticity PDF. On the other hand, the Fourier basis does not extract the coherent vortex tubes cleanly and leaves organized structures in the residual high wavenumber modes whose PDFs are stretched exponentials for both the velocity and the vorticity.

Farge, Marie↗

Converting a digital filter to its analog equivalent

Two complementary methods for conversion are direct conversion method and inverse of Tustin's method. Required accuracy of filter is achieved using best-matched technique. Both require only direct computations and are simpler and more efficient than conventional iterative systems or methods requiring "ad hoc" filter parameter adjustment.

Lee, J. F. L.↗

Constrained optimization of image restoration filters.

A preprocessing method to correct for image degradation is proposed which can be thought of as a generalization and extension of previous work by Smith (1966) and Stuller (1972). This method accomodates the problem of noncircularly symmetric imaging system point-spread functions, provides for controlled extent of the preprocessing filter to minimize distortion due to transients resulting from truncation errors and edge effects, can be used with various kinds of system noise, and can be readily extended to provide constraint of other system parameters. The analysis relates to a line-scanner system, although it is applicable in principle to many other system configurations.

Riemer, T. E.↗

GEOS-2 C-band radar system project. Spectral analysis as related to C-band radar data analysis

Work performed on spectral analysis of data from the C-band radars tracking GEOS-2 and on the development of a data compaction method for the GEOS-2 C-band radar data is described. The purposes of the spectral analysis study were to determine the optimum data recording and sampling rates for C-band radar data and to determine the optimum method of filtering and smoothing the data. The optimum data recording and sampling rate is defined as the rate which includes an optimum compromise between serial correlation and the effects of frequency folding. The goal in development of a data compaction method was to reduce to a minimum the amount of data stored, while maintaining all of the statistical information content of the non-compacted data. A digital computer program for computing estimates of the power spectral density function of sampled data was used to perform the spectral analysis study.

Source record↗

Rapid Initial-State Preparation for the Quantum Simulation of Strongly Correlated Molecules

Studies on quantum algorithms for ground-state energy estimation often assume perfect ground-state preparation; however, in reality the initial state will have imperfect overlap with the true ground state. Here, we address that problem in two ways: by faster preparation of matrix-product-state (MPS) approximations and by more efficient filtering of the prepared state to find the ground-state energy. We show how to achieve unitary synthesis with a Toffoli complexity about 7 × lower than that in prior work and use that to derive a more efficient MPS-preparation method. For filtering, we present two different approaches: sampling and binary search. For both, we use the theory of window functions to avoid large phase errors and minimize the complexity. We find that the binary-search approach provides better scaling with the overlap at the cost of a larger constant factor, such that it will be preferred for overlaps less than about 0.003 . Finally, we estimate the total resources to perform ground-state energy estimation of Fe - S cluster systems, including the Fe Mo cofactor by estimating the overlap of different MPS initial states with potential ground states of the Fe Mo cofactor using an extrapolation procedure. With a modest MPS bond dimension of 4000 , our procedure produces an estimate of approximately 0.9 overlap squared with a candidate ground state of the Fe Mo cofactor, producing a total resource estimate of 7.3 × 10 10 Toffoli gates; neglecting the search over candidates and assuming the accuracy of the extrapolation, this validates prior estimates that have used perfect ground-state overlap. This presents an example of a practical path to prepare states of high overlap in a challenging-to-compute chemical system. Published by the American Physical Society 2025

Berry, Dominic W. (ORCID:0000000334461449)↗

Modifying real convolutional codes for protecting digital filtering systems

A novel method is proposed for protecting digital filters from temporary and permanent failures that are not easily detected by conventional fault-tolerant computer design principles, on the basis of the error-detecting properties of real convolutional codes. Erroneous behavior is detected by externally comparing the calculated and regenerated parity samples. Great simplifications are obtainable by modifying the code structure to yield simplified parity channels with finite impulse response structures. A matrix equation involving the original parity values of the code and the polynomial of the digital filter's transfer function is formed, and row manipulations separate this equation into a set of homogeneous equations constraining the modifying scaling coefficients and another set which defines the code parity values' implementation.

Redinbo, G. R.↗

Target Detection via Cognitive Radars Using Change-Point Detection, Learning, and Adaptation

Many radar detection algorithms that assume a stationary environment (clutter) have been proposed and analyzed over the years. However, in practice, changes in the nonstationary environment can perturb the parameters of the clutter distribution, or even alter the clutter distribution family, which can greatly deteriorate the target detection capability. To avoid such potential performance degradation, cognitive radar systems are envisioned which are required to rapidly realize the nonstationarity, accurately learn the new characteristics of the environments, and adaptively update the detector. In this paper, aiming to develop a fully cognitive radar for target detection in nonstationary environments, we propose a unifying framework that integrates (i) change-point detection of clutter distributions by using a data-driven cumulative sum (CUSUM) algorithm and its extended version, (ii) learning/identification of clutter distribution by applying sparse theory and kernel density estimation methods, and (iii) adaptive target detection by automatically modifying the likelihood-ratio test and corresponding detection threshold. Further, with extensive numerical examples, we demonstrate the achieved improvements in detection performance due to the proposed framework in comparison to a nonadaptive case, an adaptive matched filter (AMF) method, and the clairvoyant case. Herein, we also use Wilcoxon rank-sum tests to evaluate the statistical significance of the performance improvements

42 ENGINEERING↗

The Optional VenaTech{sup Trade-Mark-Sign} Convertible{sup Trade-Mark-Sign} Vena Cava Filter: Experimental Study in Sheep

Purpose: Retrieval of optional caval filters may be impaired by filter tilting, migration, fracture, or embedding in the IVC wall. The goal of this experimental study was to evaluate a new optional filter, convertible by unlocking and removing the filter head. Methods: Forty-nine Pre-Alp sheep (average weight, 55 kg) were anesthetized. IVC was catheterized via the right femoral vein (n = 46) or via the internal jugular vein (n = 3) with a 12.9-F sheath. VenaTech{sup Trade-Mark-Sign} Convertible{sup Trade-Mark-Sign} IVC filters were inserted as either permanent filters (n = 14) or as filters to be converted. Conversion was immediately after deployment (n = 19) or delayed after 1, 3, or 6 months (n = 20). Filter delivery, deployment, and conversion with measurement of migration and tilting were evaluated by cavography. Incorporation of the filter's stabilizers and arms in the IVC wall was assessed by gross anatomy. Results: Delivery system insertion, filter release, and immediate conversion were successful in all cases. Delayed conversion was completed in all but one sheep, due to insufficient snare tension. Complimentary balloon-catheter inflation was required in 12 of 20 delayed conversions to achieve filter opening. In all 49 sheep, no thrombosis, migration, or significant tilting occurred. Within 4 weeks of conversion, the filter's stabilizers and arms were incorporated into the IVC wall. Upon removal, the filter head was free of intimal growth. Conclusions: The VenaTech{sup Trade-Mark-Sign} Convertible{sup Trade-Mark-Sign} optional IVC filter was successfully implanted in all sheep with no migration or tilting. Conversion at various dates by filter head removal was feasible in all but one case.

60 APPLIED LIFE SCIENCES↗

Radiochemical Method for Characterization of the Filter Cartridges from the IEA-R1 Reactor - 16324

The filter cartridges used in water purification system of the IEA-R1 research reactor become radioactive waste after the end of their useful life. The characterization of this waste is one step in their management, which aims at identifying and quantifying the radionuclides present, including those known as 'difficult to measure' (DTM) radionuclides. Wastes from nuclear reactors contain fission and activation products and transuranic elements, only few of them emitting gamma radiation measurable by simple gamma spectrometry methods. In routine waste management activities, the concentrations of the DTM can only be estimated by indirect methods such as scaling factors. The method of the scaling factors uses empirically determined proportions between the concentrations of DTM radionuclides and that of easily measurable gamma emitters called key nuclides (KN), to calculate DTM concentrations. Determining the scaling factors for the filter cartridges is a hard task when the number of samples is large, not only because the preparation of samples is difficult but also because the number of radionuclides to analyze is large. If it can be demonstrated that DTM and KN are both distributed evenly in the filters, less samples from each filter are necessary, reducing lab work. The aim of this paper is to present the results of the assessment of homogeneity along the filter cartridges by gamma spectrometry of chemically reduced samples. Five thin slices of five filters were burnt and the ashes quantitatively dissolved and the activity concentration of the solutions determined by gamma spectrometry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploring the Use of Alfven Waves in Magnetometer Calibration at Geosynchronous Orbit

An Alfven wave is a type magnetohydrodynamicwave that travels through a conducting fluid under the influence of a magnetic field. Researchers have successfully calculated offset vectors of magnetometers in interplanetary space by optimizing the offset to maximize certain Alfvenic properties of observed waves (Leinweber, Belcher). If suitable Alfven waves can be found in the magnetosphere at geosynchronous altitude then these techniques could be used to augment the overall calibration plan for magnetometers in this region such as on the GOES spacecraft, possibly increasing the time between regular maneuvers. Calibration maneuvers may be undesirable because they disrupt the activities of other instruments. Various algorithms to calculate an offset using Alfven waves were considered. A new variation of the Davis-Smith method was derived because it can be mathematically shown that the Davis-Smith method tolerates filtered data, which expands potential applications. The variant developed was designed to find only the offset in the plane normal to the main field because the overall direction of Earth's magnetic field rarely changes, and theory suggests the Alfvenic disturbances occur transverse to the main field. Other variations of the Davis-Smith method encounter problems with data containing waves that propagate in mostly the same direction. A searching algorithm was then designed to look for periods of time with potential Alfven waves in GOES 15 data based on parameters requiring that disturbances be normal to the main field and not change field magnitude. Final waves for calculation were hand-selected. These waves produced credible two-dimensional offset vectors when input to the Davis-Smith method. Multiple two-dimensional solutions in different planes can be combined to get a measurement of the complete offset. The resulting three dimensional offset did not show sufficient precision over several years to be used as a primary calibration method, but reflected changes in the offset fairly well, suggesting that the method could be helpful in monitoring trends of the offset vector when maneuvers cannot be used.

calibration↗

Noise reduction in spectral CT: Reducing dose and breaking the trade-off between image noise and energy bin selection

Purpose: Our purpose was to reduce image noise in spectral CT by exploiting data redundancies in the energy domain to allow flexible selection of the number, width, and location of the energy bins. Methods: Using a variety of spectral CT imaging methods, conventional filtered backprojection (FBP) reconstructions were performed and resulting images were compared to those processed using a Local HighlY constrained backPRojection Reconstruction (HYPR-LR) algorithm. The mean and standard deviation of CT numbers were measured within regions of interest (ROIs), and results were compared between FBP and HYPR-LR. For these comparisons, the following spectral CT imaging methods were used:(i) numerical simulations based on a photon-counting, detector-based CT system, (ii) a photon-counting, detector-based micro CT system using rubidium and potassium chloride solutions, (iii) a commercial CT system equipped with integrating detectors utilizing tube potentials of 80, 100, 120, and 140 kV, and (iv) a clinical dual-energy CT examination. The effects of tube energy and energy bin width were evaluated appropriate to each CT system. Results: The mean CT number in each ROI was unchanged between FBP and HYPR-LR images for each of the spectral CT imaging scenarios, irrespective of bin width or tube potential. However, image noise, as represented by the standard deviation of CT numbers in each ROI, was reduced by 36%-76%. In all scenarios, image noise after HYPR-LR algorithm was similar to that of composite images, which used all available photons. No difference in spatial resolution was observed between HYPR-LR processing and FBP. Dual energy patient data processed using HYPR-LR demonstrated reduced noise in the individual, low- and high-energy images, as well as in the material-specific basis images. Conclusions: Noise reduction can be accomplished for spectral CT by exploiting data redundancies in the energy domain. HYPR-LR is a robust method for reducing image noise in a variety of spectral CT imaging systems without losing spatial resolution or CT number accuracy. This method improves the flexibility to select energy bins in the manner that optimizes material identification and separation without paying the penalty of increased image noise or its corollary, increased patient dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗