Search NASA⌕ Search

SEARCH · Search NASA

Results for “general linear methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Effect of the refractive index on the hawking temperature: an application of the Hamilton-Jacobi method

Hawking radiation of a non-asymptotically flat 4-dimensional spherically symmetric and static dilatonic black hole (BH) via the Hamilton-Jacobi (HJ) method is studied. In addition to the naive coordinates, we use four more different coordinate systems that are well-behaved at the horizon. Except for the isotropic coordinates, direct computation by the HJ method leads to the standard Hawking temperature for all coordinate systems. The isotropic coordinates allow extracting the index of refraction from the Fermat metric. It is explicitly shown that the index of refraction determines the value of the tunneling rate and its natural consequence, the Hawking temperature. The isotropic coordinates in the conventional HJ method produce a wrong result for the temperature of the linear dilaton. Here, we explain how this discrepancy can be resolved by regularizing the integral possessing a pole at the horizon.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine learning models for estimating contamination across different curbside collection strategies

Contaminated recyclables, which are frequently discarded as waste, pose a significant challenge to the implementation of a circular economy. These contaminated recyclables impede the circulation of resources, resulting in higher processing costs at material recovery facilities (MRFs). Over the past few decades, machine learning (ML) models such as linear regression (LR), support vector machine (SVM), and random forest (RF) have evolved to provide new methods for predicting inbound contamination rates in addition to traditional statistical models. In this study, we applied ML models to predict inbound contamination rates using demographic features from 15 counties in the U.S. with different curbside collection strategies. In general, we found that ML models outperformed linear mixed models. Specifically, SVM models had the highest performance (R 2 = 0.75; mean absolute error (MAE) = 0.06), which may be due to their ability to model nonlinear relationships between features and inbound contamination rates. Further, the key predictor was population, with poverty rate being positively correlated and median age negatively correlated with inbound contamination rates. To improve the management of contamination and enhance the implementation of a circular economy, better models are needed to understand and estimate inbound contamination rates as well as identify critical factors in the present and future.

54 ENVIRONMENTAL SCIENCES↗

Deterministic and Monte Carlo Nuclear Data Adjustment Methods [Slides]

For the Bayesian Monte Carlo methodology, a need to understand convergence of the posterior moments as a function of the number of parameter realizations is required. In high-dimensional systems, it can be very costly to sample entire parameter space and perform functional evaluation for every realization. Bayesian Monte Carlo allows one to relax the GLLS approximations of model linearity and prior/posterior PDF shape. The Bayesian Stochastic Collocation Method is a deterministic approach to “sample” the parameter space. It allows one to relax the GLLS approximations of model linearity and posterior PDF shape. Higher-order posterior moments (i.e., skewness, kurtosis, etc.) can be studied through polynomial expansion. Tensor product quadrature scales poorly and can use sparse grid quadrature methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of the MLC on the MRI field distortion of a prototype MRI-linac

Purpose: To cope with intrafraction tumor motion, integrated MRI-linac systems for real-time image guidance are currently under development. The multileaf collimator (MLC) is a key component in every state-of-the-art radiotherapy treatment system, allowing for accurate field shaping and tumor tracking. This work quantifies the magnetic impact of a widely used MLC on the MRI field homogeneity for such a modality.Methods: The finite element method was employed to model a MRI-linac assembly comprised of a 1.0 T split-bore MRI magnet and the key ferromagnetic components of a Varian Millennium 120 MLC, namely, the leaves and motors. Full 3D magnetic field maps of the system were generated. From these field maps, the peak-to-peak distortion within the MRI imaging volume was evaluated over a 30 cm diameter sphere volume (DSV) around the isocenter and compared to a maximum preshim inhomogeneity of 300 μT. Five parametric studies were performed: (1) The source-to-isocenter distance (SID) was varied from 100 to 200 cm, to span the range of a compact system to that with lower magnetic coupling. (2) The MLC model was changed from leaves only to leaves with motors, to determine the contribution to the total distortion caused by MLC leaves and motors separately. (3) The system was configured in the inline or perpendicular orientation, i.e., the linac treatment beam was oriented parallel or perpendicular to the magnetic field direction. (4) The treatment field size was varied from 0 × 0 to 20×20 cm{sup 2}, to span the range of clinical treatment fields. (5) The coil currents were scaled linearly to produce magnetic field strengths B{sub 0} of 0.5, 1.0, and 1.5 T, to estimate how the MLC impact changes with B{sub 0}.Results: (1) The MLC-induced MRI field distortion fell continuously with increasing SID. (2) MLC leaves and motors were found to contribute to the distortion in approximately equal measure. (3) Due to faster falloff of the fringe field, the field distortion was generally smaller in the perpendicular beam orientation. The peak-to-peak DSV distortion was below 300 μT at SID≥130 cm (perpendicular) and SID≥140 cm (inline) for the 1.0 T design. (4) The simulation of different treatment fields was identified to cause dynamic changes in the field distribution. However, the estimated residual distortion was below 1.2 mm geometric distortion at SID≥120 cm (perpendicular) and SID≥130 cm (inline) for a 10 mT/m frequency-encoding gradient. (5) Due to magnetic saturation of the MLC materials, the field distortion remained constant at B{sub 0}>1.0 T.Conclusions: This work shows that the MRI field distortions caused by the MLC cannot be ignored and must be thoroughly investigated for any MRI-linac system. The numeric distortion values obtained for our 1.0 T magnet may vary for other magnet designs with substantially different fringe fields, however the concept of modest increases in the SID to reduce the distortion to a shimmable level is generally applicable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Signatures of Light Massive Relics on non-linear structure formation

ABSTRACT Cosmologies with Light Massive Relics (LiMRs) as a subdominant component of the dark sector are well-motivated from a particle physics perspective, and can also have implications for the σ8 tension between early and late time probes of clustering. The effects of LiMRs on the cosmic microwave background (CMB) and structure formation on large (linear) scales have been investigated extensively. In this paper, we initiate a systematic study of the effects of LiMRs on smaller, non-linear scales using cosmological N-body simulations; focusing on quantities relevant for photometric galaxy surveys. For most of our study, we use a particular model of non-thermal LiMRs but the methods developed generalizing to a large class of LiMR models – we explicitly demonstrate this by considering the Dodelson–Widrow velocity distribution. We find that, in general, the effects of LiMR on small scales are distinct from those of a ΛCDM universe, even when the value of σ8 is matched between the models. We show that weak lensing measurements around massive clusters, between ∼0.1 h−1Mpc and ∼10 h−1Mpc, should have sufficient signal-to-noise in future surveys to distinguish between ΛCDM and LiMR models that are tuned to fit both CMB data and linear scale clustering data at late times. Furthermore, we find that different LiMR cosmologies indistinguishable by conventional linear probes can be distinguished by non-linear probes if their velocity distributions are sufficiently different. LiMR models can, therefore, be best tested by jointly analyzing the CMB and late-time structure formation on both large and small scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Analytic marginalization of N(z) uncertainties in tomographic galaxy surveys

In this paper, we present a new method to marginalize over uncertainties in redshift distributions, N(z), within tomographic cosmological analyses applicable to current and upcoming photometric galaxy surveys. We allow for arbitrary deviations from the best-guess N(z) governed by a general covariance matrix describing the uncertainty in our knowledge of redshift distributions. In principle, this is marginalization over hundreds or thousands of new parameters describing potential deviations as a function of redshift and tomographic bin. However, by linearly expanding the theory predictions around a fiducial model, this marginalization can be performed analytically, resulting in a modified data covariance matrix that effectively downweights the modes of the data vector that are more sensitive to redshift distribution variations. We showcase this method by applying it to the galaxy clustering measurements from the Hyper Suprime-Cam first data release. We illustrate how to marginalize over sample variance of the calibration sample and a large general systematic uncertainty in photometric estimation methods, and explore the impact of priors imposing smoothness in the redshift distributions.

79 ASTRONOMY AND ASTROPHYSICS↗

GREAT3 results - I. Systematic errors in shear estimation and the impact of real galaxy morphology

The study present first results from the third GRavitational lEnsing Accuracy Testing (GREAT3) challenge, the third in a sequence of challenges for testing methods of inferring weak gravitational lensing shear distortions from simulated galaxy images. GREAT3 was divided into experiments to test three specific questions, and included simulated space- and ground-based data with constant or cosmologically varying shear fields. The simplest (control) experiment included parametric galaxies with a realistic distribution of signal-to-noise, size, and ellipticity, and a complex point spread function (PSF). The other experiments tested the additional impact of realistic galaxy morphology, multiple exposure imaging, and the uncertainty about a spatially varying PSF; the last two questions will be explored in Paper II. The 24 participating teams competed to estimate lensing shears to within systematic error tolerances for upcoming Stage-IV dark energy surveys, making 1525 submissions overall. GREAT3 saw considerable variety and innovation in the types of methods applied. Several teams now meet or exceed the targets in many of the tests conducted (to within the statistical errors). We conclude that the presence of realistic galaxy morphology in simulations changes shear calibration biases by ~1 per cent for a wide range of methods. Other effects such as truncation biases due to finite galaxy postage stamps, and the impact of galaxy type as measured by the Sérsic index, are quantified for the first time. Our results generalize previous studies regarding sensitivities to galaxy size and signal-to-noise, and to PSF properties such as seeing and defocus. Almost all methods’ results support the simple model in which additive shear biases depend linearly on PSF ellipticity.

79 ASTRONOMY AND ASTROPHYSICS↗

A review of pressure anisotropy caused by electron trapping in collisionless plasma, and its implications for magnetic reconnection

From spacecraft data, it is evident that electron pressure anisotropy develops in collisionless plasmas. This is in contrast to the results of theoretical investigations, which suggest this anisotropy should be limited. Common for such theoretical studies is that the effects of electron trapping are not included; simply speaking, electron trapping is a non-linear effect and is, therefore, eliminated when utilizing the standard methods for linearizing the underlying kinetic equations. Here, we review our recent work on the anisotropy that develops when retaining the effects of electron trapping. A general analytic model is derived for the electron guiding center distribution f(v{sub ∥},v{sub ⊥}) of an expanding flux tube. The model is consistent with anisotropic distributions observed by spacecraft, and is applied as a fluid closure yielding anisotropic equations of state for the parallel and perpendicular components (relative to the local magnetic field direction) of the electron pressure. In the context of reconnection, the new closure accounts for the strong pressure anisotropy that develops in the reconnection regions. It is shown that for generic reconnection in a collisionless plasma nearly all thermal electrons are trapped, and dominate the properties of the electron fluid. A new numerical code is developed implementing the anisotropic closure within the standard two-fluid framework. The code accurately reproduces the detailed structure of the reconnection region observed in fully kinetic simulations. These results emphasize the important role of pressure anisotropy for the reconnection process. In particular, for reconnection geometries characterized by small values of the normalized upstream electron pressure, β{sub e∞}, the pressure anisotropy becomes large with p{sub ∥}≫p{sub ⊥} and strong parallel electric fields develop in conjunction with this anisotropy. The parallel electric fields can be sustained over large spatial scales and, therefore, become important for electron acceleration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical Solution of the Steady-State Network Flow Equations for a Non-Ideal Gas

Herein we formulate a steady-state network flow problem for non-ideal gas that relates injection rates and nodal pressures in the network to flows in pipes. For this problem, we present and prove a theorem on uniqueness of generalized solution for a broad class of non-ideal pressure-density relations that satisfy a monotonicity property. Further, we develop a Newton-Raphson algorithm for numerical solution of the steady-state problem, which is made possible by a systematic non-dimensionalization of the equations. The developed algorithm has been extensively tested on benchmark instances and shown to converge robustly to a generalized solution. Previous results [1]-[4], indicate that the steady-state network flow equations for an ideal gas are difficult to solve by the Newton-Raphson method because of its extreme sensitivity to the initial guess. In contrast, we find that non-dimensionalization of the steady-state problem is key to robust convergence of the Newton-Raphson method. We identify criteria based on the uniqueness of solutions under which the existence of a non-physical generalized solution found by a non-linear solver implies non-existence of a physical solution, i.e., infeasibility of the problem. Finally, we compare pressure and flow solutions based on ideal and non-ideal equations of state to demonstrate the need to apply the latter in practice. The solver developed in this article is open-source and is made available for both the academic and research communities as well as the industry.

97 MATHEMATICS AND COMPUTING↗

Cognitive Foundry v. 3.0 (OSS)

The Cognitive Foundry is a unified collection of tools designed for research and applications that use cognitive modeling, machine learning, or pattern recognition. The software library contains design patterns, interface definitions, and default implementations of reusable software components and algorithms designed to support a wide variety of research and development needs. The library contains three main software packages: the Common package that contains basic utilities and linear algebraic methods, the Cognitive Framework package that contains tools to assist in implementing and analyzing theories of cognition, and the Machine Learning package that provides general algorithms and methods for populating Cognitive Framework components from domain-relevant data.

Basilico, Justin↗

SmoQyDQMC.jl: A flexible implementation of determinant quantum Monte Carlo for Hubbard and electron-phonon interactions

We introduce the SmoQyDQMC.jl package, a Julia implementation of the determinant quantum Monte Carlo algorithm. SmoQyDQMC.jl supports generalized tight-binding Hamiltonians with on-site Hubbard and generalized electron-phonon ( e e -ph) interactions, including non-linear e e -ph coupling and anharmonic lattice potentials. Our implementation uses hybrid Monte Carlo methods with exact forces for sampling the phonon fields, enabling efficient simulation of low-energy phonon branches, including acoustic phonons. The SmoQyDQMC.jl package also uses a flexible scripting interface, allowing users to adapt it to different workflows and interface with other software packages in the Julia ecosystem. The code for this package can be downloaded from our GitHub repository at https://github.com/SmoQySuite/SmoQyDQMC.jl or installed using the Julia package manager. The online documentation, including examples, can be obtained from our document page at https://smoqysuite.github.io/SmoQyDQMC.jl/stable/.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Codebase release r0.3 for SmoQyDQMC.jl

We introduce the SmoQyDQMC.jl package, a Julia implementation of the determinant quantum Monte Carlo algorithm. SmoQyDQMC.jl supports generalized tight-binding Hamiltonians with on-site Hubbard and generalized electron-phonon ( e e -ph) interactions, including non-linear e e -ph coupling and anharmonic lattice potentials. Our implementation uses hybrid Monte Carlo methods with exact forces for sampling the phonon fields, enabling efficient simulation of low-energy phonon branches, including acoustic phonons. The SmoQyDQMC.jl package also uses a flexible scripting interface, allowing users to adapt it to different workflows and interface with other software packages in the Julia ecosystem. The code for this package can be downloaded from our GitHub repository at https://github.com/SmoQySuite/SmoQyDQMC.jl or installed using the Julia package manager. The online documentation, including examples, can be obtained from our document page at https://smoqysuite.github.io/SmoQyDQMC.jl/stable/.

Cohen-Stead, Benjamin (ORCID:0000000279156280)↗

Cognitive Foundry v. 3.0 (OSS)

The Cognitive Foundry is a unified collection of tools designed for research and applications that use cognitive modeling, machine learning, or pattern recognition. The software library contains design patterns, interface definitions, and default implementations of reusable software components and algorithms designed to support a wide variety of research and development needs. The library contains three main software packages: the Common package that contains basic utilities and linear algebraic methods, the Cognitive Framework package that contains tools to assist in implementing and analyzing theories of cognition, and the Machine Learning package that provides general algorithms and methods for populating Cognitive Framework components from domain-relevant data.

Basilico, Justin↗

Technical Note: Modeling a complex micro-multileaf collimator using the standard BEAMnrc distribution

Purpose: The component modules in the standard BEAMnrc distribution may appear to be insufficient to model micro-multileaf collimators that have trifaceted leaf ends and complex leaf profiles. This note indicates, however, that accurate Monte Carlo simulations of radiotherapy beams defined by a complex collimation device can be completed using BEAMnrc's standard VARMLC component module. Methods: That this simple collimator model can produce spatially and dosimetrically accurate microcollimated fields is illustrated using comparisons with ion chamber and film measurements of the dose deposited by square and irregular fields incident on planar, homogeneous water phantoms. Results: Monte Carlo dose calculations for on-axis and off-axis fields are shown to produce good agreement with experimental values, even on close examination of the penumbrae. Conclusions: The use of a VARMLC model of the micro-multileaf collimator, along with a commissioned model of the associated linear accelerator, is therefore recommended as an alternative to the development or use of in-house or third-party component modules for simulating stereotactic radiotherapy and radiosurgery treatments. Simulation parameters for the VARMLC model are provided which should allow other researchers to adapt and use this model to study clinical stereotactic radiotherapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-BRD-06: Robust Dose Calculation in Intensity Modulated Proton Therapy

Purpose: Commissioning data for intensity modulated proton therapy (IMPT) must be post-processed by fits to ad-hoc functions to derive the dose calculation kernel parameters in a treatment planning system (TPS). Whether from experimental measurement or Monte Carlo simulation, the limited and noisy nature of such data makes this task very challenging. We present a method to improve the modeling of the lateral dose distribution of clinical energy proton beams in water to commission an in-house IMPT dose calculation engine. Methods: A linear sum of three Gaussian distribution functions was fitted to the lateral dose data in logarithmic scale. Starting values of fitting solutions were determined from the Generalized Highland Approximation. We exhaustively optimized the combinations of data weights with upper bounds of the fitting solutions to minimize confidence intervals of the fitting solutions while maintaining the coefficient of determination (R{sup 2}). Results: Across all energies, average confidence bounds improved 72.88% [Max: 88.28%, Min: 55.05%] for small angle coulomb scattering, 114.25% [409.13%, 66.72%,] for nuclear scattering, and 68.66% [141.09%, 33.27%] for large angle coulomb scattering, while the coefficients of determination of the fits (R{sup 2}) remained comparable. On average R {sup 2} only changed 0.18% and were very close to 1 (approx. 0.999). Wilcoxon signed rank tests comparing unweighted/unbounded fits with weighted/bounded fits averaged 0.0146 (Max: 0.177, Min: 7.05×10−{sup 7}) for small angle Coulomb, 0.0903 (0.945, 7.05×10−{sup 7}) for nuclear, and 0.254 (0.871, 1.86×10−{sup 6}) for large angle Coulomb scattering. This allows rejection of the null hypothesis for small angle Coulomb scattering at the 0.015 level and nuclear interaction at the 0.1 level. Conclusion: Optimal weights assigned to IMPT lateral dose data minimized fitting to stochastic noise in the tail region. Optimizing the upper bounds of fitting parameters improved the robustness of fitting solutions. Both led to a more physically meaningful dose calculation kernel for the TPS. NIH/NCI K25CA168984, Eagles Cancer Research Career Development, The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, Mayo ASU Seed Grant, and The Kemper Marley Foundation.

60 APPLIED LIFE SCIENCES↗

A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac

Purpose: To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for rendering the phase-space data compatible with BEAMnrc/DOSXYZnrc simulation software package is presented. Methods: Monte Carlo (MC) simulations were performed to benchmark the TrueBeam 6 MV FFF phase space data that have been released by the Varian MC Research team. The simulations to benchmark the phase space data were done in three steps. First, the original phase space which was created on a cylindrical surface was converted into a format that was compatible with BEAMnrc. Second, BEAMnrc was used to create field size specific phase spaces located underneath the jaws. Third, doses were calculated with DOSXYZnrc in a water phantom for fields ranging from 1 Multiplication-Sign 1 to 40 Multiplication-Sign 40 cm{sup 2}. Calculated percent depth doses (PDD), transverse profiles, and output factors were compared with measurements for all the fields simulated. After completing the benchmarking study, three stereotactic body radiotherapy (SBRT) VMAT plans created with the Eclipse treatment planning system (TPS) were calculated with Monte Carlo. Ion chamber and film measurements were also performed on these plans. 3D gamma analysis was used to compare Monte Carlo calculation with TPS calculations and with film measurement. Results: For the benchmarking study, MC calculated and measured values agreed within 1% and 1.5% for PDDs and in-field transverse profiles, respectively, for field sizes >1 Multiplication-Sign 1 cm{sup 2}. Agreements in the 80%-20% penumbra widths were better than 2 mm for all the fields that were compared. With the exception of the 1 Multiplication-Sign 1 cm{sup 2} field, the agreement between measured and calculated output factors was within 1%. It is of note that excellent agreement in output factors for all field sizes including highly asymmetric fields was achieved without accounting for backscatter into the beam monitor chamber. For the SBRT VMAT plans, the agreement between Monte Carlo and ion chamber point dose measurements was within 1%. Excellent agreement between Monte Carlo, treatment planning system and Gafchromic film dose distribution was observed with over 99% of the points in the high dose volume passing the 3%, 3 mm gamma test. Conclusions: The authors have presented a method for making the Varian IAEA compliant 6 MV FFF phase space file of the TrueBeam linac compatible with BEAMnrc/DOSXYZnrc. After benchmarking the modified phase space against measurement, they have demonstrated its potential for use in MC based quality assurance of complex delivery techniques.

60 APPLIED LIFE SCIENCES↗

Radiographic stool quantification: an equivalence study of 484 symptomatic and asymptomatic subjects

Purpose: To determine if symptomatic patients referred for radiographic stool quantification have equivalent stool burden to asymptomatic patients. Method: This was an IRB-approved HIPAA-compliant retrospective equivalence cohort study. An a priori equivalence power calculation was performed. Consecutive abdominal radiographs performed in adult outpatients with bloating, constipation, diarrhea, or abdominal pain to assess “fecal loading” [n = 242 (fecal cohort)] were compared to those performed in asymptomatic adult outpatients to assess “renal stones” [n = 242 (renal cohort)]. Radiographs were randomized and reviewed by two blinded independent abdominal radiologists. Exclusion criteria, designed to avoid unblinding, included urinary tract calculi ≥ 0.5 cm, multiple urinary tract calculi, and ureteral stent(s). Readers scored all radiographs (n = 484) for stool burden using validated Leech criteria [scale: 0 (none) to 15 (extreme diffuse)]. Mean Leech scores and 95% confidence intervals were calculated. Multivariable generalized linear modeling was performed to adjust for baseline medication use, age, and gender. The adjusted parameter estimate was used to test for equivalence in the mean difference between cohorts using Schuirmann’s method of two one-sided t-tests. Inter-reader agreement was assessed with intraclass correlation coefficients. Results: Overall mean Leech scores for fecal [6.9 (95% CI 6.7, 7.2)] and renal [7.3 (95% CI 7.1, 7.5)] cohorts were equivalent within a margin of 0.75 (adjusted mean difference: − 0.4 [90% CI − 0.7, − 0.04]; p value = 0.02). Inter-reader agreement was good [ICC: 0.62 (95% CI 0.56, 0.68)]. Conclusion: Radiographic stool quantification produces equivalent results in symptomatic and asymptomatic adults and is of uncertain value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extending Classification Algorithms to Case-Control Studies

Classification is a common technique applied to ’omics data to build predictive models and identify potential markers of biomedical outcomes. Despite the prevalence of case-control studies, the number of classification methods available to analyze data generated by such studies is extremely limited. Conditional logistic regression is the most commonly used technique, but the associated modeling assumptions limit its ability to identify a large class of sufficiently complicated ’omic signatures. We propose a data preprocessing step which generalizes and makes any linear or nonlinear classification algorithm, even those typically not appropriate for matched design data, available to be used to model case-control data and identify relevant biomarkers in these study designs. We demonstrate on simulated case-control data that both the classification and variable selection accuracy of each method is improved after applying this processing step and that the proposed methods are comparable to or outperform existing variable selection methods. Finally, we demonstrate the impact of conditional classification algorithms on a large cohort study of children with islet autoimmunity.

59 BASIC BIOLOGICAL SCIENCES↗