Search NASA⌕ Search

SEARCH · Search NASA

Results for “high resolution detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Progress Towards High-Sensitivity Arrays of Detectors of Sub-mm Radiation Using Superconducting Tunnel Junctions with Integrated Radio Frequency Single-Electron Transistors

For high resolution imaging and spectroscopy in the FIR and submillimeter, space observatories will demand sensitive, fast, compact, low-power detector arrays with 104 pixels and sensitivity less than 10(exp -20) W/Hz(sup 0.5). Antenna-coupled superconducting tunnel junctions with integrated rf single-electron transistor readout amplifiers have the potential for achieving this high level of sensitivity, and can take advantage of an rf multiplexing technique. The device consists of an antenna to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure current through junctions contacting the absorber. We describe optimization of device parameters, and results on fabrication techniques for producing devices with high yield for detector arrays. We also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

Stevenson, T. R.↗

Modeling Charge Collection in Detector Arrays

A detector array charge collection model has been developed for use as an engineering tool to aid in the design of optical sensor missions for operation in the space radiation environment. This model is an enhancement of the prototype array charge collection model that was developed for the Next Generation Space Telescope (NGST) program. The primary enhancements were accounting for drift-assisted diffusion by Monte Carlo modeling techniques and implementing the modeling approaches in a windows-based code. The modeling is concerned with integrated charge collection within discrete pixels in the focal plane array (FPA), with high fidelity spatial resolution. It is applicable to all detector geometries including monolithc charge coupled devices (CCDs), Active Pixel Sensors (APS) and hybrid FPA geometries based on a detector array bump-bonded to a readout integrated circuit (ROIC).

Hardage, Donna↗

Synthetic Foveal Imaging Technology

Synthetic Foveal imaging Technology (SyFT) is an emerging discipline of image capture and image-data processing that offers the prospect of greatly increased capabilities for real-time processing of large, high-resolution images (including mosaic images) for such purposes as automated recognition and tracking of moving objects of interest. SyFT offers a solution to the image-data processing problem arising from the proposed development of gigapixel mosaic focal-plane image-detector assemblies for very wide field-of-view imaging with high resolution for detecting and tracking sparse objects or events within narrow subfields of view. In order to identify and track the objects or events without the means of dynamic adaptation to be afforded by SyFT, it would be necessary to post-process data from an image-data space consisting of terabytes of data. Such post-processing would be time-consuming and, as a consequence, could result in missing significant events that could not be observed at all due to the time evolution of such events or could not be observed at required levels of fidelity without such real-time adaptations as adjusting focal-plane operating conditions or aiming of the focal plane in different directions to track such events. The basic concept of foveal imaging is straightforward: In imitation of a natural eye, a foveal-vision image sensor is designed to offer higher resolution in a small region of interest (ROI) within its field of view. Foveal vision reduces the amount of unwanted information that must be transferred from the image sensor to external image-data-processing circuitry. The aforementioned basic concept is not new in itself: indeed, image sensors based on these concepts have been described in several previous NASA Tech Briefs articles. Active-pixel integrated-circuit image sensors that can be programmed in real time to effect foveal artificial vision on demand are one such example. What is new in SyFT is a synergistic combination of recent advances in foveal imaging, computing, and related fields, along with a generalization of the basic foveal-vision concept to admit a synthetic fovea that is not restricted to one contiguous region of an image.

Hoenk, Michael↗

Demonstration of Energy-Resolved γ-Ray Detection at Room Temperature by the CsPbCl 3 Perovskite Semiconductor

The detection of gamma-rays at room temperature with high-energy resolution using semiconductors is one of the most challenging applications. The presence of even the smallest amount of defects is sufficient to kill the signal generated from gamma-rays which makes the availability of semiconductors detectors a rarity. Lead halide perovskite semiconductors exhibit unusually high defect tolerance leading to outstanding and unique optoelectronic properties and are poised to strongly impact applications in photoelectric conversion/detection. Here we demonstrate for the first time that large size single crystals of the all-inorganic perovskite CsPbCl 3 semiconductor can function as a high-performance detector for gamma-ray nuclear radiation at room temperature. CsPbCl 3 is a wide-gap semiconductor with a bandgap of 3.03 eV and possesses a high effective atomic number of 69.8. We identified the two distinct phase transitions in CsPbCl 3 , from cubic (Pm-3m) to tetragonal (P4/mbm) at 325 K and finally to orthorhombic (Pbnm) at 316 K. Despite crystal twinning induced by phase transitions, CsPbCl 3 crystals in detector grade can be obtained with high electrical resistivity of similar to 1.7 X 10 9 Ω∙cm. The crystals were grown from the melt with volume over several cubic centimeters and have a low thermal conductivity of 0.6 W m -1 K -1 . The mobilities for electron and hole carriers were determined to similar to 30 cm 2 /(V s). Using photoemission yield spectroscopy in air (PYSA), we determined the valence band maximum at 5.66 +/- 0.05 eV. Under gamma-ray exposure, our Schottky-type planar CsPbCl 3 detector achieved an excellent energy resolution (similar to 16% at 122 keV) accompanied by a high figure-of-merit hole mobility-lifetime product (3.2 x 10 -4 cm 2 /V) and a long hole lifetime (16 mu s). The results demonstrate considerable defect tolerance of CsPbCl 3 and suggest its strong potential for gamma-radiation and X-ray detection at room temperature and above.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Energy X-Ray Diffraction Microscopy in Materials Science

High-energy diffraction microscopy (HEDM) is an implementation of three-dimensional X-ray diffraction microscopy. HEDM yields maps of internal crystal orientation fields, strain states, grain shapes and locations as well as intragranular orientation distributions, and grain boundary character. Because it is nondestructive in hard materials, notably metals and ceramics, HEDM has been used to study responses of these materials to external fields including high temperature and mechanical loading. Currently available sources and detectors lead to a spatial resolution of ~1 μm and an orientation resolution of <0.1°. With the penetration characteristic of high energies ( E ≥ 50 keV), sample cross-section dimensions of ~1 mm can be studied in materials containing elements across much of the Periodic Table. This review describes hardware and software associated with HEDM as well as examples of applications. Overall, these applications include studies of grain growth, recrystallization, texture development, orientation gradients, deformation twinning, annealing twinning, plastic deformation, and additive manufacturing. We also describe relationships to other X-ray-based methods as well as prospects for further development.

36 MATERIALS SCIENCE↗

Imaging Based Detector with Efficient Scintillators for Neutron Diffraction Measurements

The Anger Camera developed by the detector group at the Oak Ridge National Laboratory was utilized for the present work for its unique advantage of employing multiple modules to obtain large active measurement area for detecting diffracted/scattered thermal neutrons. Considering the relatively small flux associated with diffracted/scattered neutrons, suitable efficiency with high spatial resolution is a requirement for utilizing two-dimensional imaging detectors. The potential to implement pulse shape (in addition to pulse height) discrimination-based scintillators further enhances the ability to detect diffracted neutrons with improved signal to noise ratio. In this paper, initial results associated with 6Li glass-based scintillator will be presented. The authors explored the feasibility of using this system to detect and quantify diffraction peaks and peak shifts at the Neutron Residual Stress Facility (NRSF2), High Flux Isotope Reactor (HFIR) in the Oak Ridge National Laboratory (ORNL). Suitable camera mounting and shielding had to be developed. Reference measurements using polycrystalline powders with known atomic planar spacing will be discussed along with measurement settings associated with expected resolution for peak shift measurements. Initial results are promising and demonstrate that a suitable scintillation-based neutron detecting system is viable for residual stress-based diffraction measurements. Small area detectors are also feasible with suitable consideration to scattering volume and distance to detector.

Seals, Matthew↗

A space qualified thermal imaging system using a Pt Si detector array

EDO Corporation, Barnes Engineering Division designed and constructed a high resolution thermal imaging system on contract to Lockheed for use in the SDI Star Lab. This employs a Pt Si CCD array which is sensitive in the spectral range of 3 to 5 microns. Star Lab will be flown in the Shuttle bay and consists basically of a large, reflecting, tracking telescope with associated sensors and electronics. The thermal imaging system is designed to operate in the focal plane of this telescope. The configuration of the system is illustrated. The telescope provides a collimated beam output which is focussed onto the detector array by a silicon objective lens. The detector array subtends a field of view of 1.6 degrees x 1.22 degrees. A beam switching mirror permits bypassing the large telescope to give a field of 4 degrees x 3 degrees. Two 8 position filter wheels are provided, and background radiation is minimized by Narcissus mirrors. The detector is cooled with a Joule-Thompson cryostat fed from a high pressure supply tank. This was selected instead of a more convenient closed-cycle system because of concern with vibration. The latter may couple into the extremely critical Starlab tracking telescope. The electronics produce a digitized video signal for recording. Offset and responsivity correction factors are stored for all pixels and these corrections are made to the digitized output in real time.

Astheimer, Robert W.↗

A comprehensive study of the X-ray structure and spectrum of IC 443

This paper presents the results of a comprehensive study of the X-ray emission from the supernova remnant IC 443, using the solid state spectrometer, IPC, and high-resolution images of the Einstein Observatory, and the medium-energy detector of the HEAO 1 A-2 experiment. A soft X-ray appearance was observed, highly atypical of a supernova remnant in the adiabatic phase, with little correlation between X-ray and optical or radio features. The best-fit models of the low-energy X-ray spectrum of the brightest area of the remnant suggest either that the remnant has not yet attained ionization equilibrium or that the X-rays arise in a multiphase medium. Pronounced soft X-ray spectral differences across the remnant are accounted for by variations in absorption by an intervening molecular cloud. The analysis suggests that, despite the atypical X-ray appearance, the X-ray emission in IC 443 is probably confined to a thin (0.1 pc) shell.

Petre, R.↗

Measurement of the Neutron Magnetic Form Factor at Large Momentum Transfer Using the Super-Bigbite Apparatus in Jefferson Lab Hall-A

The nucleon elastic electromagnetic form factors help us study the electromagnetic structure of the nucleon, benchmark theoretical models, and improve our understanding of non-perturbative quantum chromodynamics and confinement. The Nobel Prize-winning electron-nucleon scattering experiments by Robert Hofstadter and collaborators in the 1950s at Stanford High Energy Physics Lab were the first nucleon form factor measurements performed using leptonic probes. The Super Bigbite Spectrometer (SBS) program at Hall-A of Jefferson Lab represents the latest efforts to measure nucleon form factors. This ambitious program aims to significantly extend the current data set in terms of square momentum transfer (Q2) with high precision. The advent of novel detector technologies, like Gas Electron Multipliers (GEM), which provide excellent position resolution (< 100 ?m) while withstanding high background particle rates (several hundred MHz/cm2) over a large active area, has paved the way for open-geometry, moderate solid angle spectrometers, which are central to all form factor experiments in the SBS program. The first experimental run group in SBS ran successfully between September 2021 and February 2022, collecting data for the measurement of the magnetic form factor of the neutron Gn M at five squared momentum-transfer values: 3.0, 4.5, 7.5, 9.8, and 13.5 (GeV /c)2. This extends the existing high-precision data for Gn M by about a factor of four. The ratio technique was used, which involved the simultaneous measurement of exclusive quasielastic scattering of D(e,e?n)p and D(e,e?p)n from a deuterium target. Pre-preliminary results for D(e,e?n)p and D(e,e?p)n quasi-elastic ratio, and the neutron magnetic form factor Gn M , for Q2 points 3.0, 9.8, and 13.5 (GeV /c)2 are presented.

Mudiyanselage, Anuruddha Rathnayake↗

Uses of continuum radiation in the AXAF calibration

X-ray calibration of the Advanced X-ray Astrophysics Facility (AXAF) observatory at the MSFC X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis.

Kolodziejczak, J. J.↗

Uses of Continuum Radiation in the AXAF Calibration

X-ray calibration of the Advanced X-ray Astrophysics Facility (AXAF) observatory at the MSFC X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis.

Kolodziejczak, J. J.↗

Progress in Using Continuum radiation for AXAF Calibration

X-ray calibration of the AXAF observatory at MSFC's X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis. Further verification of AXAF response models will be presented.

Kolodziejczak, J. J.↗

High Spatial Resolution Thermal Satellite Technologies

This document in the form of viewslides, reviews various low-cost alternatives to high spatial resolution thermal satellite technologies. There exists no follow-on to Landsat 7 or ASTER high spatial resolution thermal systems. This document reviews the results of the investigation in to the use of new technologies to create a low-cost useful alternative. Three suggested technologies are examined. 1. Conventional microbolometer pushbroom modes offers potential for low cost Landsat Data Continuity Mission (LDCM) thermal or ASTER capability with at least 60-120 ground sampling distance (GSD). 2. Backscanning could produce MultiSpectral Thermal Imager performance without cooled detectors. 3. Cooled detector could produce hyperspectral thermal class system or extremely high spatial resolution class instrument.

Ryan, Robert↗

Performance of neutron spectrum unfolding using deuterated liquid scintillator

The performance of the maximum likelihood expectation maximization method for unfolding neutron energy spectra using deuterated liquid scintillator is evaluated for future utilization with rare isotope beams. High-resolution neutron energy spectra as well as the detector response matrix were measured at the Edwards Accelerator Laboratory at Ohio University. Maximum-likelihood expectation maximization (MLEM) unfolded neutron spectra are compared with spectra from neutron time-of-flight. In conclusion, the effects of the MLEM stopping criteria and spectrum statistics are also investigated.

47 OTHER INSTRUMENTATION↗

Evaluation of the absolute single-photon detection efficiency of HRPPD

Pixelated High Rate Picosecond Photon Detectors (HRPPDs) by Incom Inc. are promising photosensors for use in Ring Imaging CHerenkov (RICH) detectors, where a high gain, sub-mm position resolution and sub-100ps timing resolution are required in a single photon mode. Quantum Efficiency (QE) has been measured for the first batch of EIC HRPPDs both by Incom and EIC research groups at Jefferson Lab and Brookhaven Lab, with peak values at ∼365 nm typically exceeding 30%. Furthermore, in this study, we present a first direct measurement of Photon Detection Efficiency being equal to (17.1 ± 0.1 [stat] ± 0.3 [sys])% at 398.6 nm, for a pixel near the center of HRPPD, in a photoelectron pulse counting mode using a picosecond diode laser. HRPPD QE at the same spot and at the same wavelength was evaluated to be (24.4 ± 0.1 [stat] ± 0.3 [sys])%, leading to a Collection Efficiency estimate of (70.3 ± 1.6)%, which is consistent with the expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Difficult Measurements of Materials Systems at Cryogenic Temperatures: Cryo-EELS and Cryo-4D-STEM

Scanning/transmission electron microscopy (S/TEM) in materials science has traditionally been accomplished at room temperature due to their solid state in this temperature range and relative insensitivity to radiolysis damage. Cooling to cryogenic temperatures tended to introduce instabilities such as vibration and drift and can lead to the buildup of carbon contamination or ice reducing contrast. The need to expand TEM experimental techniques into new fields such as quantum and battery materials led to new efforts to reduce these instabilities while achieving temperatures at or well below liquid nitrogen (77 K). Further, developments in detector and spectrometer technology brought new capabilities for high resolution electron energy loss spectroscopy (EELS) and scanning nanodiffraction (4D-STEM). These experimental modalities can require even tighter controls of drift, vibration, and exposure time. Here this presentation will discuss accomplishing difficult experiments at cryogenic temperatures in honor of the late Dr. Lena Kourkoutis who inspired and led many such experiments.

36 MATERIALS SCIENCE↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

Solving challenges in QCD 3D partonic distributions

The superior luminosity and high polarization of CEBAF, combined with the high resolution and excellent particle identification capabilities of its detectors, as well as the ability for multidimensional and multiparticle detection using polarized targets, make Jefferson Lab uniquely positioned to disentangle the genuine intrinsic transverse structure of hadrons encoded in 3D partonic distributions—particularly in the kinematic regime dominated by valence quarks. The inclusion of Jefferson Lab data on semi-inclusive and hard exclusive hadron production has the potential to dramatically advance our understanding of non-perturbative QCD dynamics. Although a wealth of data from various Jefferson Lab experiments is already available, its incorporation into phenomenological studies has been slow, and a significant portion of data from other leptoproduction experiments is still missing from global fits. In this contribution, we discuss the existing challenges and outline a path forward for improving the analysis of low center-of-mass electroproduction experiments in general, and Jefferson Lab data in particular.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗