Search NASA⌕ Search

SEARCH · Search NASA

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Information, entropy and fidelity in visual communication

This paper presents an assessment of visual communication that integrates the critical limiting factors of image gathering and display with the digital processing that is used to code and restore images. The approach focuses on two mathematical criteria, information and fidelity, and on their relationships to the entropy of the encoded data and to the visual quality of the restored image.

Huck, Friedrich O.↗

Combining image-processing and image compression schemes

An investigation into the combining of image-processing schemes, specifically an image enhancement scheme, with existing compression schemes is discussed. Results are presented on the pyramid coding scheme, the subband coding scheme, and progressive transmission. Encouraging results are demonstrated for the combination of image enhancement and pyramid image coding schemes, especially at low bit rates. Adding the enhancement scheme to progressive image transmission allows enhanced visual perception at low resolutions. In addition, further progressing of the transmitted images, such as edge detection schemes, can gain from the added image resolution via the enhancement.

Greenspan, H.↗

A high quality image compression scheme for real-time applications

Many image compression or coding techniques have been developed to reduce the amount of bits of information needed to represent digital images. Among these, Vector Quantization (VQ) seems to have the edge; its theoretical distortion is lower than that of other block coding techniques at comparable bit rates. However, the application of Vector Quantization remains limited due to its high computational complexity. Presently, it is limited to low to medium quality image compression. In this paper it is shown that VQ can be mapped onto VLSI implementation via systolic type architecture, making real time application possible. In addition, it is shown that using multistage or cascade VQ high quality images can be obtained at very low bit rates for real time applications while using smaller codebooks than is necessary in single stage VQ. Examples of processed images are presented.

Ramamoorthy, P. A.↗

Deep learning for lipid droplet recognition in quantitative phase images

This library of Python code is used for performing semantic segmentation of images using 6 different machine learning methods. Five of the methods are implemented entirely within the scikit-learn framework. The Convolutional Neural Network (CNN) method requires Keras with a TensorFlow backend and generally uses a different set of scripts in order to perform the complete training and evaluation.

Sheneman, Lucas↗

Stereo-DIC Challenge 1.0 – Rigid Body Motion of a Complex Shape

Background Stereo-DIC is a widely used optical measurement technique that provides a dense full-field 3D measurement of the shape, displacement, and strain of a solid sample. When compared with 2D-DIC, Stereo-DIC provides greater flexibility and expands its use beyond flat, planar specimens. Furthermore, the widespread availability of commercial systems has led to the adoption of the technique throughout industry, academia, and government research labs. Objective Even though some research has been done to understand the effects of different experimental and stereo-DIC parameters, no reference is available to benchmark and compare the performance of current stereo-DIC algorithms to each other. Methods This paper provides the description and analysis of a carefully controlled 3D experiment and associated images used to compare the results from five subset based DIC software packages. Both the images and analysis codes used in this paper to compare the results are described here and are available for download and use for continued research. Results We show that over a very large range of motion, the 3D errors are very small, less than 80μm over a travel of ±20 mm out-of-plane and ±20 mm in-plane. While all codes performed similarly, there are important differences noted in the paper. Conclusion The image sets and results comparison software are hosted by the International DIC Society (www.iDICs.org) and are freely available for download and analysis for comparison with results in this paper. Furthermore, it is hoped that this set of images can be used for future research in improving stereo-DIC by future authors.

Algorithms comparison↗

Recovery of reflectance from imaging spectrometer measured radiance using a radiative transfer code

Radiance data were acquired over part of the Clark Mountain Range, California in 1990 by the Airborne Visible Infrared Imaging Spectrometer (AVIRIS). From these calibrated radiance data, the lateral distribution of water vapor in precipitable mm was recovered through analysis of the 940 nm water absorption. Surface pressure height was calculated from the 760 nm oxygen absorption band in the AVIRIS data. Surface slopes are estimated from relative elevations derived from the equivalent water vapor elevation for a standard atmosphere. Atmospheric optical depths measured at the Mountain Pass site in these data are extended to the entire region and varied based on the calculated surface pressure elevation. These parameters, derived from every AVIRIS spatial element, are used to constrain the LOWTRAN 7 radiative transfer code for the recovery of surface reflectance. Once transformed to reflectance, the imaging spectrometer data may be analyzed quantitatively for determination of surface composition, and compared with reflectance measurements acquired from different locations, times, and instruments.

Green, Robert O.↗

Rethinking skip connections in Spiking Neural Networks with Time-To-First-Spike coding

Time-To-First-Spike (TTFS) coding in Spiking Neural Networks (SNNs) offers significant advantages in terms of energy efficiency, closely mimicking the behavior of biological neurons. In this work, we delve into the role of skip connections, a widely used concept in Artificial Neural Networks (ANNs), within the domain of SNNs with TTFS coding. Our focus is on two distinct types of skip connection architectures: (1) addition-based skip connections, and (2) concatenation-based skip connections. We find that addition-based skip connections introduce an additional delay in terms of spike timing. On the other hand, concatenation-based skip connections circumvent this delay but produce time gaps between after-convolution and skip connection paths, thereby restricting the effective mixing of information from these two paths. To mitigate these issues, we propose a novel approach involving a learnable delay for skip connections in the concatenation-based skip connection architecture. This approach successfully bridges the time gap between the convolutional and skip branches, facilitating improved information mixing. We conduct experiments on public datasets including MNIST and Fashion-MNIST, illustrating the advantage of the skip connection in TTFS coding architectures. Additionally, we demonstrate the applicability of TTFS coding on beyond image recognition tasks and extend it to scientific machine-learning tasks, broadening the potential uses of SNNs.

97 MATHEMATICS AND COMPUTING↗

Infrared imaging - A validation technique for computational fluid dynamics codes used in STOVL applications

The need for a validation technique for computational fluid dynamics (CFD) codes in STOVL applications has led to research efforts to apply infrared thermal imaging techniques to visualize gaseous flow fields. Specifically, a heated, free-jet test facility was constructed. The gaseous flow field of the jet exhaust was characterized using an infrared imaging technique in the 2 to 5.6 micron wavelength band as well as conventional pitot tube and thermocouple methods. These infrared images are compared to computer-generated images using the equations of radiative exchange based on the temperature distribution in the jet exhaust measured with the thermocouple traverses. Temperature and velocity measurement techniques, infrared imaging, and the computer model of the infrared imaging technique are presented and discussed. From the study, it is concluded that infrared imaging techniques coupled with the radiative exchange equations applied to CFD models are a valid method to qualitatively verify CFD codes used in STOVL applications.

Hardman, R. R.↗

Method and System for Producing Images of an Object

A method and system are provided to produce images of an object. A receiving station is positioned in view of a range-coded signal emitting satellite and the object. The receiving station is sensitive to direct transmission of the range-coded signal and reflections of the range-coded signal from the object. Both range from the receiving station to the object and a Doppler frequency shift history between the receiving station and the object is determined using the direct transmission and reflections of the range-coded signal. An image is formed using the two-dimensional record provided by the range and the Doppler frequency shift history.

Katzberg, Stephen J.↗

Methods for increasing the sensitivity of gamma-ray imagers

Methods are presented that increase the position resolution and granularity of double sided segmented semiconductor detectors. These methods increase the imaging resolution capability of such detectors, either used as Compton cameras, or as position sensitive radiation detectors in imagers such as SPECT, PET, coded apertures, multi-pinhole imagers, or other spatial or temporal modulated imagers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systems for increasing the sensitivity of gamma-ray imagers

Systems that increase the position resolution and granularity of double sided segmented semiconductor detectors are provided. These systems increase the imaging resolution capability of such detectors, either used as Compton cameras, or as position sensitive radiation detectors in imagers such as SPECT, PET, coded apertures, multi-pinhole imagers, or other spatial or temporal modulated imagers.

47 OTHER INSTRUMENTATION↗

Demonstration of object location, classification, and characterization by developed deep learning dust ablation trail analysis code package using plasma jets

Based on deep learning, a Dust Ablation Trail Analysis (DATA) code package is developed to detect dust ablation trails in tokamaks, which is intended to analyze a large amount data of tokamak dusts. To validate and benchmark the DATA code package, 2440 plasma jet images are exploited for the training and test of the deep learning DATA code package, since plasma jets resemble the shape and size of dust ablation clouds in tokamaks. After being trained by 1920 plasma jet images, the DATA code package is able to locate 100% plasma jets, classify plasma jets with the accuracy of >99.9%, and output image skeleton information for classified plasma jets. The DATA code package trained by the plasma jet images is also used to analyze the dust ablation trails captured in the Experimental Advanced Superconducting (EAST) tokamak with the satisfactory performance, further verifying its applicability in the fusion dust ablation investigation. Based on its excellent performance presented here, it is demonstrated that our DATA code package is able to automatically identify and analyze dust ablation trails in tokamaks, which can be used for further detailed investigations, such as the three-dimensional reconstruction of dusts and their ablation trails.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Orthogonal spatial coding with stimulated parametric down-conversion

Orthogonal optical coding is widely used in classical multi-user communication networks. Using the phase conjugation property of stimulated parametric down-conversion, we extend the current time-domain orthogonal optical coding scheme to the spatial domain to encode and decode image information. In this process, the idler beam inherits the complex conjugate of the field information encoded in the seed beam. An encoding phase mask introduced onto the input seed beam blurs the image transferred to the idler. The original image is restored by passing the coded transferred image through a corrective phase mask placed in the momentum space of the idler beam. We expect that this scheme can also inspire new techniques in secure image transmission, aberration cancellation, and frequency conversion imaging.

Xu, Yang↗

Model-Based Least Squares Reconstruction of Coded Source Neutron Radiographs: Integrating the ORNL HFIR CG1D Source Model

At the present, neutron sources cannot be fabricated small and powerful enough in order to achieve high resolution radiography while maintaining an adequate flux. One solution is to employ computational imaging techniques such as a Magnified Coded Source Imaging (CSI) system. A coded-mask is placed between the neutron source and the object. The system resolution is increased by reducing the size of the mask holes and the flux is increased by increasing the size of the coded-mask and/or the number of holes. One limitation of such system is that the resolution of current state-of-the-art scintillator-based detectors caps around 50um. To overcome this challenge, the coded-mask and object are magnified by making the distance from the coded-mask to the object much smaller than the distance from object to detector. In previous work, we have shown via synthetic experiments that our least squares method outperforms other methods in image quality and reconstruction precision because of the modeling of the CSI system components. However, the validation experiments were limited to simplistic neutron sources. In this work, we aim to model the flux distribution of a real neutron source and incorporate such a model in our least squares computational system. We provide a full description of the methodology used to characterize the neutron source and validate the method with synthetic experiments.

Coded Apertures↗

Solid-State Photomultiplier Development for Radiation Detection

We are pursuing the sensitivity of back-thinned silicon (BT Si) with the gain of an SSPM (Baker 2011). Working in collaboration with Radiation Monitoring Devices, Inc., we are designing and fabricating prototype devices. Our original idea spurred from hybrid designs of advanced image sensors that use the sensitivity of BT Si that is then bump bonded to a CMOS readout device. As shown in the graph below (right), the BT Si has a far superior quantum efficiency (QE) than the standard photocathode response available in photomultiplier tubes (PMTs). Collecting as many scintillation photons as possible is the first objective. There has been major concern that the prototype could not deliver the ~105 electronic gain of a PMT. However, recently developed SSPMs do provide the electronic gain needed. We are now pursuing the design of a BTSSPM. With a smaller footprint, the SSPM can potentially lead to a simple, compact deployment package. Because the SSPM can be pixelated and tiled, we foresee developing an imaging detector. Pinhole imaging of radiation sources is a well-exercised technology. Our implementation of the coded aperture (Marks 2010) imager provides a high throughput pinhole imager. We intend to apply miniature coded apertures to minimal pixel count SSPMs to evaluate image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.

Qiao, Zhi (ORCID:0000000233928732)↗

TH-E-18A-01: Developments in Monte Carlo Methods for Medical Imaging

Monte Carlo simulation methods are widely used in medical physics research and are starting to be implemented in clinical applications such as radiation therapy planning systems. Monte Carlo simulations offer the capability to accurately estimate quantities of interest that are challenging to measure experimentally while taking into account the realistic anatomy of an individual patient. Traditionally, practical application of Monte Carlo simulation codes in diagnostic imaging was limited by the need for large computational resources or long execution times. However, recent advancements in high-performance computing hardware, combined with a new generation of Monte Carlo simulation algorithms and novel postprocessing methods, are allowing for the computation of relevant imaging parameters of interest such as patient organ doses and scatter-to-primaryratios in radiographic projections in just a few seconds using affordable computational resources. Programmable Graphics Processing Units (GPUs), for example, provide a convenient, affordable platform for parallelized Monte Carlo executions that yield simulation times on the order of 10{sup 7} xray/ s. Even with GPU acceleration, however, Monte Carlo simulation times can be prohibitive for routine clinical practice. To reduce simulation times further, variance reduction techniques can be used to alter the probabilistic models underlying the x-ray tracking process, resulting in lower variance in the results without biasing the estimates. Other complementary strategies for further reductions in computation time are denoising of the Monte Carlo estimates and estimating (scoring) the quantity of interest at a sparse set of sampling locations (e.g. at a small number of detector pixels in a scatter simulation) followed by interpolation. Beyond reduction of the computational resources required for performing Monte Carlo simulations in medical imaging, the use of accurate representations of patient anatomy is crucial to the virtual generation of medical images and accurate estimation of radiation dose and other imaging parameters. For this, detailed computational phantoms of the patient anatomy must be utilized and implemented within the radiation transport code. Computational phantoms presently come in one of three format types, and in one of four morphometric categories. Format types include stylized (mathematical equation-based), voxel (segmented CT/MR images), and hybrid (NURBS and polygon mesh surfaces). Morphometric categories include reference (small library of phantoms by age at 50th height/weight percentile), patient-dependent (larger library of phantoms at various combinations of height/weight percentiles), patient-sculpted (phantoms altered to match the patient's unique outer body contour), and finally, patient-specific (an exact representation of the patient with respect to both body contour and internal anatomy). The existence and availability of these phantoms represents a very important advance for the simulation of realistic medical imaging applications using Monte Carlo methods. New Monte Carlo simulation codes need to be thoroughly validated before they can be used to perform novel research. Ideally, the validation process would involve comparison of results with those of an experimental measurement, but accurate replication of experimental conditions can be very challenging. It is very common to validate new Monte Carlo simulations by replicating previously published simulation results of similar experiments. This process, however, is commonly problematic due to the lack of sufficient information in the published reports of previous work so as to be able to replicate the simulation in detail. To aid in this process, the AAPM Task Group 195 prepared a report in which six different imaging research experiments commonly performed using Monte Carlo simulations are described and their results provided. The simulation conditions of all six cases are provided in full detail, with all necessary data on material composition, source, geometry, scoring and other parameters provided. The results of these simulations when performed with the four most common publicly available Monte Carlo packages are also provided in tabular form. The Task Group 195 Report will be useful for researchers needing to validate their Monte Carlo work, and for trainees needing to learn Monte Carlo simulation methods. In this symposium we will review the recent advancements in highperformance computing hardware enabling the reduction in computational resources needed for Monte Carlo simulations in medical imaging. We will review variance reduction techniques commonly applied in Monte Carlo simulations of medical imaging systems and present implementation strategies for efficient combination of these techniques with GPU acceleration. Trade-offs involved in Monte Carlo acceleration by means of denoising and “sparse sampling” will be discussed. A method for rapid scatter correction in cone-beam CT (<5 min/scan) will be presented as an illustration of the simulation speeds achievable with optimized Monte Carlo simulations. We will also discuss the development, availability, and capability of the various combinations of computational phantoms for Monte Carlo simulation of medical imaging systems. Finally, we will review some examples of experimental validation of Monte Carlo simulations and will present the AAPM Task Group 195 Report. Learning Objectives: Describe the advances in hardware available for performing Monte Carlo simulations in high performance computing environments. Explain variance reduction, denoising and sparse sampling techniques available for reduction of computational time needed for Monte Carlo simulations of medical imaging. List and compare the computational anthropomorphic phantoms currently available for more accurate assessment of medical imaging parameters in Monte Carlo simulations. Describe experimental methods used for validation of Monte Carlo simulations in medical imaging. Describe the AAPM Task Group 195 Report and its use for validation and teaching of Monte Carlo simulations in medical imaging.

60 APPLIED LIFE SCIENCES↗

Temperature, Pressure, and Infrared Image Survey of an Axisymmetric Heated Exhaust Plume

The focus of this research is to numerically predict an infrared image of a jet engine exhaust plume, given field variables such as temperature, pressure, and exhaust plume constituents as a function of spatial position within the plume, and to compare this predicted image directly with measured data. This work is motivated by the need to validate computational fluid dynamic (CFD) codes through infrared imaging. The technique of reducing the three-dimensional field variable domain to a two-dimensional infrared image invokes the use of an inverse Monte Carlo ray trace algorithm and an infrared band model for exhaust gases. This report describes an experiment in which the above-mentioned field variables were carefully measured. Results from this experiment, namely tables of measured temperature and pressure data, as well as measured infrared images, are given. The inverse Monte Carlo ray trace technique is described. Finally, experimentally obtained infrared images are directly compared to infrared images predicted from the measured field variables.

Nelson, Edward L.↗