Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Identification of hydrothermal alteration assemblages using airborne imaging spectrometer data

Airborne Imaging Spectrometer (AIS) data, field and laboratory spectra and samples for X-ray diffraction analysis were collected in argillically altered Tertiary volcanic rocks in the Hot Creek Range, Nevada. From laboratory and field spectral measurements in the 2.0 to 2.4 micron range and using a spectroradiometer with a 4 nm sampling interval, the absorption band centers for kaolinite were loacted at 2.172 and 2.215 microns, for montmorillonite at 2.214 micron and for illite at 2.205. Based on these values and the criteria for resolution and separtion of spectral features, a spectral sampling interval of less than 4 nm is necessary to separate the clays. With an AIS spectral sampling interval of 9.3 nm, a spectral matching algorithm is more effective for separating kaolinite, montmorillonite, ad illite in Hot Creek Range than using the location of absorption minima alone.

Feldman, S. C.↗

Interactive imaging and data processing

Image processing method is capable of contrast enhancement, noise filtering, and photometric distortion removal in near real time. System uses digital image integration and digital video recorder as image buffer. Each frame of data is entered into memory; registers provide readout of stored TV frame.

Alsberg, H.↗

TH-E-17A-07: Improved Cine Four-Dimensional Computed Tomography (4D CT) Acquisition and Processing Method

Purpose: Artifacts arising from the 4D CT acquisition and post-processing methods add systematic uncertainty to the treatment planning process. We propose an alternate cine 4D CT acquisition and post-processing method to consistently reduce artifacts, and explore patient parameters indicative of image quality. Methods: In an IRB-approved protocol, 18 patients with primary thoracic malignancies received a standard cine 4D CT acquisition followed by an oversampling 4D CT that doubled the number of images acquired. A second cohort of 10 patients received the clinical 4D CT plus 3 oversampling scans for intra-fraction reproducibility. The clinical acquisitions were processed by the standard phase sorting method. The oversampling acquisitions were processed using Dijkstras algorithm to optimize an artifact metric over available image data. Image quality was evaluated with a one-way mixed ANOVA model using a correlation-based artifact metric calculated from the final 4D CT image sets. Spearman correlations and a linear mixed model tested the association between breathing parameters, patient characteristics, and image quality. Results: The oversampling 4D CT scans reduced artifact presence significantly by 27% and 28%, for the first cohort and second cohort respectively. From cohort 2, the inter-replicate deviation for the oversampling method was within approximately 13% of the cross scan average at the 0.05 significance level. Artifact presence for both clinical and oversampling methods was significantly correlated with breathing period (ρ=0.407, p-value<0.032 clinical, ρ=0.296, p-value<0.041 oversampling). Artifact presence in the oversampling method was significantly correlated with amount of data acquired, (ρ=-0.335, p-value<0.02) indicating decreased artifact presence with increased breathing cycles per scan location. Conclusion: The 4D CT oversampling acquisition with optimized sorting reduced artifact presence significantly and reproducibly compared to the phase-sorted clinical acquisition.

60 APPLIED LIFE SCIENCES↗

The Mariner Venus Mercury flight data subsystem.

The flight data subsystem (FDS) discussed handles both the engineering and scientific measurements performed on the MVM'73. It formats the data into serial data streams, and sends it to the modulation/demodulation subsystem for transmission to earth or to the data storage subsystem for storage on a digital tape recorder. The FDS is controlled by serial digital words, called coded commands, received from the central computer sequencer of from the ground via the modulation/demodulation subsystem. The eight major blocks of the FDS are: power converter, timing and control, engineering data, memory, memory input/output and control, nonimaging data, imaging data, and data output. The FDS incorporates some 4000 components, weighs 17 kg, and uses 35 W of power. General data on the mission and spacecraft are given.

Whitehead, P. B.↗

Planetary Data Systems (PDS) Imaging Node Atlas II

The Planetary Image Atlas (PIA) is a Rich Internet Application (RIA) that serves planetary imaging data to the science community and the general public. PIA also utilizes the USGS Unified Planetary Coordinate system (UPC) and the on-Mars map server. The Atlas was designed to provide the ability to search and filter through greater than 8 million planetary image files. This software is a three-tier Web application that contains a search engine backend (MySQL, JAVA), Web service interface (SOAP) between server and client, and a GWT Google Maps API client front end. This application allows for the search, retrieval, and download of planetary images and associated meta-data from the following missions: 2001 Mars Odyssey, Cassini, Galileo, LCROSS, Lunar Reconnaissance Orbiter, Mars Exploration Rover, Mars Express, Magellan, Mars Global Surveyor, Mars Pathfinder, Mars Reconnaissance Orbiter, MESSENGER, Phoe nix, Viking Lander, Viking Orbiter, and Voyager. The Atlas utilizes the UPC to translate mission-specific coordinate systems into a unified coordinate system, allowing the end user to query across missions of similar targets. If desired, the end user can also use a mission-specific view of the Atlas. The mission-specific views rely on the same code base. This application is a major improvement over the initial version of the Planetary Image Atlas. It is a multi-mission search engine. This tool includes both basic and advanced search capabilities, providing a product search tool to interrogate the collection of planetary images. This tool lets the end user query information about each image, and ignores the data that the user has no interest in. Users can reduce the number of images to look at by defining an area of interest with latitude and longitude ranges.

Stanboli, Alice↗

A concept for a future ground control data set for image correction

Strips of ground control can be established with current and future satellite sensors. These can provide precise and reliable geometric references for locating and correcting satellite image data and to support temporal image registration. This paper briefly describes the concept and approach for implementing this data base called a Ground Control Strip, and recommends additional work. The advent of new solid state imaging systems, in particular the linear array detectors (pushbroom sensors), make this new concept particularly attractive and practical.

Bernstein, R.↗

Automatic mineral map generation procedure from imaging spectrometer data

An airborne imaging spectrometer collected data for 128 wave length channels covering from near to short wavelength infrared across a 320 m swath, to help obtain a mineral map of an area based on reflectance spectral signatures of the area. Minerals have distinctive crystal structures and chemical contents which can be identified by their light absorption characteristics, and an optimized automatic mineral map generation procedure for imaging spectrometer data was developed. The procedure generates two types of mineral maps, a mineral distribution map showing spatial layout of various minerals and a mineral composition map showing the percentage composition of a selected mineral.

Lee, M.↗

An operational method for estimating signal to noise ratios from data acquired with imaging spectrometers

A method, using the concept of local means and local standard deviations of small imaging blocks and using a box counting procedure, has been developed for unsupervised estimation of the average signal to noise ratios of images in which the noise is additive. The method has been applied to simulated images with Gaussian noise, to images acquired with the Airborne Visible Infrared Imaging Spectrometer and with the Geophysical and Environmental Research Imaging Spectrometer. The method is compared with other techniques for estimating signal to noise ratios from imaging data. It is believed that the method is generally applicable to images having many small homogeneous blocks. Because the method does not take into account interband effects, it is not appropriate to use the method to estimate signal to noise ratios from images having nonnegligible interband radiometric calibration errors at spatial scales less than or equal to the size of the small imaging blocks used in the noise estimation.

Gao, Bo-Cai↗

SU-F-J-201: Validation Study of Proton Radiography Against CT Data for Quantitative Imaging of Anatomical Changes in Head and Neck Patients

Purpose: In clinical pencil-beam-scanned (PBS) proton therapy, the advantage of the characteristic sharp dose fall-off after the Bragg Peak (BP) becomes a disadvantage if the BP positions of a plan’s constituent pencil beams are shifted, eg.due to anatomical changes. Thus, for fractionated PBS proton therapy, accurate knowledge of the water equivalent path length (WEPL) of the traversed anatomy is critical. In this work we investigate the feasibility of using 2D proton range maps (proton radiography, PR) with the active-scanning gantry at PSI. Methods: We simulated our approach using Monte Carlo methods (MC) to simulate proton beam interactions in patients using clinical imaging data. We selected six head and neck cases having significant anatomical changes detected in per-treatment CTs.PRs (two at 0°/90°) were generated from MC simulations of low-dose pencil beams at 230MeV. Each beam’s residual depth-dose was propagated through the patient geometry (from CT) and detected on exiting the patient anatomy in an ideal depth-resolved detector (eg. range telescope). Firstly, to validate the technique, proton radiographs were compared to the ground truth, which was the WEPL from ray-tracing in the patient CT at the pencil beam location. Secondly, WEPL difference maps (per-treatment – planning imaging timepoints) were then generated to locate the anatomical changes, both in the CT (ground truth) and in the PRs. Binomial classification was performed to evaluate the efficacy of the technique relative to CT. Results: Over the projections simulated over all six patients, 70%, 79% and 95% of the grid points agreed with the ground truth proton range to within ±0.5%, ±1%, and ±3% respectively. The sensitivity, specificity, precision and accuracy were high (mean±1σ, 83±8%, 87±13%, 95±10%, 83±7% respectively). Conclusion: We show that proton-based radiographic images can accurately monitor patient positioning and in vivo range verification, while providing equivalent WEPL information to a CT scan, with the advantage of a much lower imaging dose.

60 APPLIED LIFE SCIENCES↗

Adaptive Bandwidth Compression For Moving Images

Data compressed in images with fast motion and expanded when motion slows. Proposed data-compression scheme adapts transmission rate for moving image to speed of motion of image. Laser rangefinder measures speed of target. Adaptive sampler determines required resolution of target image on basis of measured speed and provides decommutator at control station with more or fewer partial image fields per unit time. When monitor displays maximum number of fields simultaneously, resolution is highest.

Graham, Olin L.↗

Systems and methods for verification and authentication of remote sensing imagery

A system for generating and authenticating remote sensing imagery includes a remote sensing platform. The remote sensing platform includes an imaging sensor and a hardware logic device that is directly coupled to the imaging sensor. The hardware logic device receives image data from the imaging sensor and generates a cryptographic signature based upon the image data. The hardware logic device outputs a signed image that includes the image data and the cryptographic signature. A computing device operated by a downstream user receives the signed image and can determine whether the image data has been modified from its original content based upon the cryptographic signature.

Crosby, Sean Michael↗

Combining S-space and image spatial information for characterization of land-cover elements using AVIRIS data

Imaging spectroscopy data provides information that is both spatially and spectrally rich. However,hyperspectral classification and identification procedures are generally based solely on the spectral data. The S-space concept treats the spectrum as a 'spatial' dimension thereby facilitating the exploration of a relationship between the spectral and spatial image domains. This paper presents the ideas that will be researched as well as some preliminary results.

AVIRIS image spectroscopy↗

BIRP - A way to search through image engineering data

Several hundred thousand images have been returned by planetary missions and by earth-orbiting satellites. Locating specific images for study based on engineering data can be cumbersome and time consuming if done manually. BIRP, a FORTRAN program for small computers, is designed to quickly search through catalogs of image engineering data. A description of the desired images is entered and the BIRP program finds the images meeting the requirements. A videodisk player or microfiche reader may be controlled by BIRP so that images can be viewed immediately after a search. A search through 50,000 images on a single parameter takes less than 1 min on a minicomputer. Data for each parameter is stored in a separate file so that the number of files and thus the storage space required may be varied to fit computers with different storage capacities. Most modern minicomputers with FORTRAN compilers and an 8-bit byte variable type may use BIRP with minor modifications to the program.

Bolef, L. K.↗

Data fusion enhanced multi-modality wellbore integrity inspection system

A downhole multi-modality inspection system includes a first imaging device operable to generate first imaging data and a second imaging device operable to generate second imaging data. The first imaging device includes a first source operable to emit energy of a first modality, and a first detector operable to detect returning energy induced by the emitted energy of the first modality. The second imaging device includes a second source operable to emit energy of a second modality, and a second detector operable to detect returning energy induced by the emitted energy of the second modality. The system further includes a processor configured to receive the first imaging data and the second imaging data, and integrate the first imaging data with the second imaging data into an enhanced data stream. The processor correlates the first imaging data and the second imaging data to provide enhanced data for detecting potential wellbore anomalies.

Kasten, Ansas Matthias↗

Air-To-Air Background Oriented Schlieren Technique

An air-to-air background-oriented Schlieren system and method for measuring and rendering visible density changes in air that cause a refractive index change by an airborne vehicle. A sensor aircraft equipped with a high-speed visible spectrum camera travels at low airspeed on a predetermined route and on a level altitude over a background having consistent contrast and sunlight reflectivity. The target aircraft, traveling on the same predetermined route but at an altitude between the sensor aircraft and the ground (background) passes beneath the sensor aircraft. The camera on the sensor aircraft captures a series of images including a reference image immediately before the target aircraft enters the image frame followed by several data images as the target aircraft passes through the image frame. The data images are processed to calculate density gradients around the target aircraft. These density gradients include shockwaves, vortices, engine exhaust, and wakes. Air density gradients cause a refractive index change in the fluid and a slight distortion in the background pattern of the data image. Image processing that compares the data image to the reference image yields the difference caused by the density gradient.

Heineck, James Thomas↗

Air-to-air background oriented schlieren technique

An air-to-air background-oriented Schlieren system and method for measuring and rendering visible density changes in air that cause a refractive index change by an airborne vehicle. A sensor aircraft equipped with a high-speed visible spectrum camera travels at low airspeed on a predetermined route and on a level altitude over a background having consistent contrast and sunlight reflectivity. The target aircraft, traveling on the same predetermined route but at an altitude between the sensor aircraft and the ground (background) passes beneath the sensor aircraft. The camera on the sensor aircraft captures a series of images including a reference image immediately before the target aircraft enters the image frame followed by several data images as the target aircraft passes through the image frame. The data images are processed to calculate density gradients around the target aircraft. These density gradients include shockwaves, vortices, engine exhaust, and wakes. Air density gradients cause a refractive index change in the fluid and a slight distortion in the background pattern of the data image. Image processing that compares the data image to the reference image yields the difference caused by the density gradient.

Heineck, James Thomas↗