Search NASA⌕ Search

SEARCH · Search NASA

Results for “intact samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Hypervelocity impact survivability experiments for carbonaceous impactors

We performed a series of hypervelocity impact experiments using carbon-bearing impactors (diamond, graphite, fullerenes, phthalic acid crystals, and Murchison meteorite) into Al plate at velocities between 4.2 and 6.1 km/s. These tests were made to do the following: (1) determine the survivability of carbon forms and organize molecules in low hypervelocity impact; (2) characterize carbonaceous impactor residues; and (3) determine whether or not fullerenes could form from carbonaceous impactors, under our experimental conditions, or survive as impactors. An analytical protocol of field emission SEM imagery, SEM-EDX, laser Raman spectroscopy, single and 2-stage laser mass spectrometry, and laser induced fluorescence (LIF) found the following: (1) diamonds did not survive impact at 4.8 km/s, but were transformed into various forms of disordered graphite; (2) intact, well-ordered graphite impactors did survive impact at 5.9 km/sec, but were only found in the crater bottom centers; the degree of impact-induced disorder in the graphite increases outward (walls, rims, ejecta); (3) phthalic acid crystals were destroyed on impact (at 4.2 km/s, although a large proportion of phthalic acid molecules did survive impact); (4) fullerenes did not form as products of carbonaceous impactors (5.9 - 6.1 km/s, fullerene impactor molecules mostly survived impact at 5.9 km/s; and (5) two Murchison meteorite samples (launched at 4.8 and 5.9 km/s) show preservation of some higher mass polycyclic aromatic hydrocarbons (PAHs) compared with the non-impacted sample. Each impactor type shows unique impactor residue morphologies produced at a given impact velocity. An expanded methodology is presented to announce relatively new analytical techniques together with innovative modifications to other methods that can be used to characterize small impact residues in LDEF craters, in addition to other acquired extraterrestrial samples.

Bunch, T. E.↗

Chemical and Thermodynamic Constraints on the Thermal Evolution of Eucrites

Vesta is the only differentiated asteroid with a nearly intact crust, making it the candidate for studying early planetary differentiation. It is commonly thought that the howardite, eucrite, and diogenite (HED) clan of meteorites derive from Vesta, and thus the study of HEDs is important for understanding the evolution of primitive bodies in the early solar system [1]. Of particular interest are the unusual trace element abundances in Stannern group eucrites, which have been interpreted as partial melting and melt contamination events that occurred on the parent body during thermal metamorphism[2]. However, some samples that contain evidence of high temperature metamorphism, such as Elephant Moraine (EET) 90020, have anomalous REE patterns that have been interpret-ed multiple ways. For example [3] concluded that the loss of small degrees of partial melt depleted the sample in LREEs while [4] concluded that subsolidus diffusion better explained why depletion of only some highly incompatible elements is observed. The heterogeneous nature of this sample makes reconstructing its petrologic history challenging. Here, we conduct further petrographic and chemical studies on polished thin sections of EET 90020 and compare results to previous studies [3-5]. Additionally, we combine chemical analyses with thermodynamic models in order to refine the constraints on the post-crystallization thermal history of EET 90020. We additionally include studies of Graves Nunataks (GRA) 98098, which also contains evidence of high temperature metamorphism and anomalous geochemical signatures, as well as evidence of solid state diffusion at lower temperatures [6].

Gorce, Jennifer S.↗

Microchannel gel electrophoretic separation systems and methods for preparing and using

A micro-analytical platform for performing electrophoresis-based immunoassays was developed by integrating photopolymerized cross-linked polyacrylamide gels within a microfluidic device. The microfluidic immunoassays are performed by gel electrophoretic separation and quantifying analyte concentration based upon conventional polyacrylamide gel electrophoresis (PAGE). To retain biological activity of proteins and maintain intact immune complexes, native PAGE conditions were employed. Both direct (non-competitive) and competitive immunoassay formats are demonstrated in microchips for detecting toxins and biomarkers (cytokines, c-reactive protein) in bodily fluids (serum, saliva, oral fluids). Further, a description of gradient gels fabrication is included, in an effort to describe methods we have developed for further optimization of on-chip PAGE immunoassays. The described chip-based PAGE immunoassay method enables immunoassays that are fast (minutes) and require very small amounts of sample (less than a few microliters). Use of microfabricated chips as a platform enables integration, parallel assays, automation and development of portable devices.

47 OTHER INSTRUMENTATION↗

Microchannel gel electrophoretic separation systems and methods for preparing and using

A micro-analytical platform for performing electrophoresis-based immunoassays was developed by integrating photopolymerized cross-linked polyacrylamide gels within a microfluidic device. The microfluidic immunoassays are performed by gel electrophoretic separation and quantifying analyte concentration based upon conventional polyacrylamide gel electrophoresis (PAGE). To retain biological activity of proteins and maintain intact immune complexes, native PAGE conditions were employed. Both direct (non-competitive) and competitive immunoassay formats are demonstrated in microchips for detecting toxins and biomarkers (cytokines, c-reactive protein) in bodily fluids (serum, saliva, oral fluids). Further, a description of gradient gels fabrication is included, in an effort to describe methods we have developed for further optimization of on-chip PAGE immunoassays. The described chip-based PAGE immunoassay method enables immunoassays that are fast (minutes) and require very small amounts of sample (less than a few microliters). Use of microfabricated chips as a platform enables integration, parallel assays, automation and development of portable devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging Intact Filamentous Fungi from Spore to Hyphal Tip on the Nanoscale

Previously, the Pacific Northwest National Laboratory was limited by a 3-order of magnitude gap in resolution for direct 2-D and 3-D imaging of chemical, biological, energy and materials science systems. Our imaging instrumentation could directly visualize 3-D ultrastructure without labeling at resolutions less than 10-nanometers or greater than 10-micrometers. To address this gap, we procured and commissioned a Sigray NanoFast Bio-Lambda laboratory-based x-ray nanotomography system. This equipment provides the capability to image through tens of micrometers of organic materials at down to 35-nanometer resolution to bridge the nanoscale to the mesoscale for biological systems, organic polymers, environmental and particulate samples.

47 OTHER INSTRUMENTATION↗

Common helical V1V2 conformations of HIV-1 Envelope expose the α4β7 binding site on intact virions

The α4β7 integrin is a non-essential HIV-1 adhesion receptor, bound by the gp120 V1V2 domain, facilitating rapid viral dissemination into gut-associated lymphoid tissues. Antibodies blocking this interaction early in infection can improve disease outcome, and V1V2-targeted antibodies were correlated with moderate efficacy reported from the RV144 HIV-1 vaccine trial. Monoclonal α4β7-blocking antibodies recognise two slightly different helical V2 conformations, and current structural data suggests their binding sites are occluded in prefusion envelope trimers. Here, we report cocrystal structures of two α4β7-blocking antibodies from an infected donor complexed with scaffolded V1V2 or V2 peptides. Both antibodies recognised the same helix-coil V2 conformation as RV144 antibody CH58, identifying a frequently sampled alternative conformation of full-length V1V2. In the context of Envelope, this α-helical form of V1V2 displays highly exposed α4β7-binding sites, potentially providing a functional role for non-native Envelope on virion or infected cell surfaces in HIV-1 dissemination, pathogenesis, and vaccine design.

59 BASIC BIOLOGICAL SCIENCES↗

Cytoskeletal organization in microtentacles

Microtentacles are thin, flexible cell protrusions that have recently been described and whose presence enhances efficient attachment of circulating cells. They are found on circulating tumor cells and can be induced on a wide range of breast cancer cell lines, where they are promoted by factors that either stabilize microtubules or destabilize the actin cytoskeleton. Evidence suggests that they are relevant to the metastatic spread of cancer, so understanding their structure and formation may lead to useful therapies. Microtentacles are formed by microtubules and contain vimentin intermediate filaments, but beyond this, there is little information about their ultrastructure. We have used electron microscopy of high pressure frozen sections and tomography of cryo-prepared intact cells, along with super resolution fluorescence microscopy, to provide the first ultrastructural insights into microtubule and intermediate filament arrangement within microtentacles. By scanning electron microscopy it was seen that microtentacles form within minutes of addition of drugs that stabilize microtubules and destabilize actin filaments. Mature microtentacles were found to be well below one micrometer in diameter, tapering gradually to below 100 nm at the distal ends. They also contained frequent branches and bulges suggestive of heterogeneous internal structure. Super resolution fluorescence microscopy and examination of sectioned samples showed that the microtubules and intermediate filaments can occupy different areas within the microtentacles, rather than interacting intimately as had been expected. Cryo-electron tomography of thin regions of microtentacles revealed densely packed microtubules and absence of intermediate filaments. The number of microtubules ranged from several dozen in some areas to just a few in the thinnest regions, with none of the regular arrangement found in axonemes. Improved understanding of the mechanism of microtentacle formation, as well as the resultant structure, will be valuable in developing therapies against metastasis, if the hypothesized role of microtentacles in metastasis is confirmed. This work provides a significant step in this direction. - Highlights: • Microtentacles can form within minutes of the addition of inducing drugs. Microtentacle diameters are in the range of a tenth of a micrometer. • Microtubules are clearly resolved in microtentacles by cryo-electron tomography. • There is little microtubule-intermediate filament interaction in drug-induced microtentacles.

60 APPLIED LIFE SCIENCES↗

Use of an ocular wound chamber for the prevention of exposure keratopathy in a guinea pig model

Abstract Current therapies available to treat and heal ocular surface injuries and periocular burns are frequently inadequate, costly, and labor intensive. To address these limitations, we have employed a flexible, semitransparent ocular wound chamber (OWC) to provide protection as well as a watertight seal to allow for the constant delivery of therapeutics to the ocular surface and surrounding periocular tissue. This study demonstrates the safety and utilization of the OWC on uninjured eyes and in our exposure keratopathy model. For initial safety studies ( N = 3 per group), the eyelids remained intact and the eye uninjured. A blepharotomy ( N = 6 per group) was performed to remove the upper and lower eyelids surrounding the left (OS) eye to create our exposure keratopathy model. Right (OD) eyes served as uninjured controls in all studies. Following OWC placement, 0.5 mL HPMC gel or balanced saline solution (BSS) was injected into the chamber. Animals were monitored daily and fully assessed via white light, fluorescein, and OCT imaging at least through 72 hours post OWC placement. In studies that included a blepharotomy, skin samples were analyzed by multiplex cytokine analysis. Results of safety experiments revealed no significant differences between treatment groups in corneal thickness, fluorescein staining, OCT imaging, or histological eye or skin sections when compared to control eyes. In our exposure keratopathy model, OWC treated eyes showed significantly less fluorescein uptake and also were found to have significantly lower levels of cytokines IL‐13 and IL‐5 in skin samples. These results demonstrate for the first time that treatment using the OWC device is not only safe, but significantly protects against blepharotomy‐induced exposure keratopathy. As a whole, this study advances our overall efforts to develop a feasible solution to treat ocular surface injuries, infections, and periocular burns.

Holt, Andrew W.↗

LONG-TERM TECHNETIUM INTERACTIONS WITH REDUCING CEMENTITIOUS MATERIALS

Technetium is among the key risk drivers at the Saltstone Facility. The way that it is immobilized in this cementitious waste form is by converting its highly mobile Tc(VII) form to a much less mobile Tc(IV) form through reduction by the cement's blast furnace slag. This report includes a review of published data and experimental results dealing with Tc leaching from Portland cement waste forms. The objectives for the literature study were to document previous reports of Tc interactions with slag-containing cementitious materials. The objectives for the laboratory study were to measure Tc-saltstone Kd values under reducing conditions. From the literature it was concluded: (1) Spectroscopic evidence showed that when Tc(IV) in a slag-cement was exposed to an oxidizing environment, it will convert to the more mobile Tc(VII) species within a short time frame, 2.5 years. (2) SRS saltstone will reduce Tc(VII) in the absence of NaS or sodium dithionite in a reducing atmosphere. (3) Only trace concentrations of atmospheric oxygen (30 to 60 ppm O{sub 2}; Eh 120 mV) at the high pH levels of cementitious systems is required to maintain Tc as Tc(VII). (4) Experimental conditions must be responsible for wide variability of measured K{sub d} values, such that they are either very low, {approx}1 mL/g, or they are very high {approx}1000 mL/g, suggesting that Tc(VII) or Tc(IV) dominate the systems. Much of this variability appears to be the result of experimental conditions, especially direct controls of oxygen contact with the sample. (5) A field study conducted at SRS in the 1980s indicated that a slag-saltstone immobilized Tc for 2.5 years. Below background concentrations of Tc leached out of the slag-containing saltstone, whereas Tc leached out of the slag-free saltstone at the rate of nitrate loss. One possible explanation for the immobilization of Tc in this study was that the slag-saltstone maintained reducing conditions within the core of the 55-gallon sample, whereas in the small-scale lab experiments, where samples were crushed to <1mm, oxygen diffused through the particles and reoxidize the slag during the contact period. (6) Present site specific reduction capacity value of 820 {micro}eq/g is in the realm of literature values that were either measured or theoretically estimated based on thermodynamic calculations. (7) Almond and Kaplan (2011) measured desorption K{sub d} values from a Vault 4 saltstone core sample. Desorption leaching tests were conducted in a glovebag maintained at 30 to 60 ppm O2. A ground olive-colored saltstone sample, as compared to black monolith sample, was used in this study, indicating the sample had been exposed to O2, which is likely the cause for the lower then anticipated Kd value measured, 139 mL/g. Tc adsorption experiments were conducted under reducing conditions (<0.5 ppm O{sub 2}(g) -585 mV, 2% H{sub 2}, pH 11.66) and obtained K{sub d} values of {approx}1000 mL/g in a saltstone formulated with 45% slag (nominal concentration) and a K{sub d} of 10,000 mL/g when the saltstone contained 95% slag. The K{sub d} values logarithmically increased from 1 day to 56 days, with little sorption generally occurring in the first eight days. Steady state had not been achieved during the initial 56 days. However, the slag-free cement control samples also had K{sub d} values near 1000 mL/g and extremely low redox conditions, due to the 2% H{sub 2} atmosphere. A key concept that this literature review and the experimental results provide is that Tc immobilization is dependent on experimental conditions, specifically, the available oxygen that can oxidize technetium in a portland cement or saltstone-like monolith. The shrinking core model used in the saltstone performance assessment describes the existence of an oxidized outer layer of concrete surrounding a shrinking core of reducing intact saltstone. A sharp boundary between the two zones moves slowly inward, resulting in oxidation of Tc(IV). This work largely reinforced our conceptual model of the shrinking core model, but more importantly provided clarity regarding process kinetics, mechanisms, and input values for future detailed modeling. The shrinking core model in itself is devoid of geochemical mechanisms. This study provided more geochemical detail to this conceptual numerical model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Trace Explosives Signatures from World War II Unexploded Undersea Ordnance

Trace explosives signatures of TNT and DNT have been extracted from multiple sediment samples adjacent to unexploded undersea ordnance at Halifax Harbor, Canada. The ordnance was hurled into the harbor during a massive explosion some 50 years earlier, in 1945 after World War II had ended. Laboratory sediment extractions were made using the solid-phase microextraction (SPME) method in seawater and detection using the Reversal Electron Attachment Detection (READ) technique and, in the case of DNT, a commercial gas chromatograph/mass spectrometer (GC/MS). Results show that, after more than 50 years in the environment, ordnance that appeared to be physically intact gave good explosives signatures at the parts per billion level, whereas ordnance that had been cracked open during the explosion gave no signatures at the 10 parts per trillion sensitivity level. These measurements appear to provide the first reported data of explosives signatures from undersea unexploded ordnance.

Darrach, M. R.↗

Activation of intact bacteria and bacterial fragments mixed with agar as cloud droplets and ice crystals in cloud chamber experiments

Biological particles, including bacteria and bacterial fragments, have beenof much interest due to the special ability of some to nucleate ice atmodestly supercooled temperatures. This paper presents results from a recentstudy conducted on two strains of cultivated bacteria which suggest thatbacterial fragments mixed with agar, and not whole bacterial cells, serve ascloud condensation nuclei (CCN). Due to the absence of whole bacteria cellsin droplets, they are unable to serve as ice nucleating particles (INPs) inthe immersion mode under the experimental conditions. Experiments wereconducted at the Aerosol Interaction and Dynamics in the Atmosphere (AIDA)cloud chamber at the Karlsruhe Institute of Technology (KIT) by injectingbacteria-containing aerosol samples into the cloud chamber and inducing cloudformation by expansion over a temperature range of -5 to -12 ° C.Cloud droplets and ice crystals were sampled through a pumped counterflowvirtual impactor inlet (PCVI) and their residuals were characterized with asingle particle mass spectrometer (miniSPLAT). The size distribution of theoverall aerosol was bimodal, with a large particle mode composed of intactbacteria and a mode of smaller particles composed of bacterial fragmentsmixed with agar that were present in higher concentrations. Results fromthree expansions with two bacterial strains indicate that the cloud dropletresiduals had virtually the same size distribution as the smaller particlesize mode and had mass spectra that closely matched those of bacterialfragments mixed with agar. The characterization of ice residuals that weresampled through an ice-selecting PCVI (IS-PCVI) also shows that the sameparticles that activate to form cloud droplets, bacteria fragments mixed withagar, were the only particle type observed in ice residuals. These resultsindicate that the unavoidable presence of agar or other growth media inall laboratory studies conducted on cultivated bacteria can greatlyaffect the results and needs to be considered when interpreting CCN and INactivation data.

54 ENVIRONMENTAL SCIENCES↗

Depth profiling analysis of solar wind helium collected in diamond-like carbon film from Genesis

The distribution of solar-wind ions in Genesis mission collectors, as determined by depth profiling analysis, constrains the physics of ion solid interactions involving the solar wind. Thus, they provide an experimental basis for revealing ancient solar activities represented by solar-wind implants in natural samples. We measured the first depth profile of ⁴He in a collector; the shallow implantation (peaking at <20 nm) required us to use sputtered neutral mass spectrometry with post-photoionization by a strong field. The solar wind He fluence calculated using depth profiling is ~8.5 x 10¹⁴ cm⁻². The shape of the solar wind ⁴He depth profile is consistent with TRIM simulations using the observed ⁴He velocity distribution during the Genesis mission. It is therefore likely that all solar-wind elements heavier than H are completely intact in this Genesis collector and, consequently, the solar particle energy distributions for each element can be calculated from their depth profiles. Ancient solar activities and space weathering of solar system objects could be quantitatively reproduced by solar particle implantation profiles.

79 ASTRONOMY AND ASTROPHYSICS↗

Chemical Sensing of Unexploded Ordnance with the Mobile Underwater Survey System (MUDSS)

The ability to sense explosives residues in the marine environment is a critical tool for identification and classification of underwater unexploded ordnance (UXO). Trace explosives signatures of TNT and DNT have been extracted from multiple sediment samples adjacent to unexploded undersea ordnance at Halifax Harbor, Canada. The ordnance was hurled into the harbor during a massive explosion fifty years earlier, in 1945 after World War II had ended. Laboratory sediment extractions were made using the solid-phase microextraction (SPME) method in seawater, and detection using the Reversal Electron Attachment Detection (READ) technique and, in the case of DNT, a commercial gas-chromatography/mass spectrometer (GC/MS). Results show that, after more than 50 years in the environment, ordnance which appeared to be physically intact gave good explosives signatures at the parts-per-billion level, whereas ordnance which had been cracked open during the explosion gave no signatures at the 10 parts-per-trillion sensitivity level. These measurements appear to provide the first reported data of explosives signatures from undersea UXOs.

Darrach, M. R.↗

Genesis Mission Bulk Metallic Glass Solar Wind Collector: Characterization of Return Samples Available for Re-Allocation

The Genesis mission collected solar wind atoms for 28 months with a variety of collectors mounted on a spacecraft. A total of fifteen pure materials were selected as collectors based on engineering and science requirements. One of the materials was the bulk metallic glass (BMG). It was intended for collecting noble gases and solar energetic particles (SEP). This material is an amorphous metal which was custom made by C.C. Hays at the California Institute of Technology. The final glass composition is Zr58.5Nb2.8Cu15.6Ni12.8Al10.3 (in atom percent). The BMG was located on top of the wafer array mechanism and was exposed for the entire time the science canister was open (~28 months). Fortunately, the BMG did not suffer any serious damage and was intact after the Genesis canister’s “hard-landing” into the Utah desert (Fig. 1).

Gonzalez, C. P.↗

Side-specific effects by cadmium exposure: Apical and basolateral treatment in a coculture model of the blood-air barrier

Cadmium (Cd{sup 2+}) is a widespread environmental pollutant, which is associated with a wide variety of cytotoxic and metabolic effects. Recent studies showed that intoxication with the heavy metal most importantly targets the integrity of the epithelial barrier. In our study, the lung epithelial cell line, NCI H441, was cultured with the endothelial cell line, ISO-HAS-1, as a bilayer on a 24-well HTS-Transwell (registered) filter plate. This coculture model was exposed to various concentrations of CdCl{sub 2}. The transepithelial electrical resistance decreased on the apical side only after treatment with high Cd{sup 2+} concentrations after 48 h. By contrast, a breakdown of TER to less than 5% of baseline could be observed much earlier (after 24 h) when Cd{sup 2+} was administered from the basal side. Observations of cell layer fragmentation and widening of intercellular spaces confirmed the barrier breakdown only for the basolaterally treated samples. Furthermore, the cytotoxicity and release of proinflammatory markers was enhanced if samples were exposed to Cd{sup 2+} from the basal side compared to treatment from the apical side. Moreover, we could demonstrate that a high concentration of Ca{sup 2+} could prevent the barrier-disrupting effect of Cd{sup 2+}. In conclusion, the exposure of Cd{sup 2+} to cocultures of lung cells caused a decrease in TER, major morphological changes, a reduction of cell viability and an increase of cytokine release, but the effects markedly differed between the two modes of exposure. Therefore, our results suggest that intact epithelial TJs may play a major role in protecting the air-blood barrier from inhaled Cd{sup 2+}.

60 APPLIED LIFE SCIENCES↗

Montana Cropland Enrolled Farm Fields Carbon Sequestration Field Sampling, Measurement, Monitoring, and Verification: Application of Visible-Near Infrared Diffuse Reflectance Spectroscopy (VNIR) and Laser-induced Breakdown Spectroscopy (LIBS)

There is growing need for rapid, accurate, and inexpensive methods to measure, and verify soil organic carbon (SOC) change for national greenhouse gas accounting and the development of a soil carbon trading market. Laboratory based soil characterization typically requires significant soil processing, which is time and resource intensive. This severely limits application for large-region soil characterization. Thus, development of rapid and accurate methods for characterizing soils are needed to map soil properties for precision agriculture applications, improve regional and global soil carbon (C) stock and flux estimates and efficiently map sub-surface metal contamination, among others. The greatest gains for efficient soil characterization will come from collecting soil data in situ, thus minimizing soil sample transportation, processing, and lab-based measurement costs. Visible and near-infrared diffuse reflectance spectroscopy (VisNIR) and laser-induced breakdown spectroscopy (LIBS) are two complementary, yet fundamentally different spectroscopic techniques that have the potential to meet this need. These sensors have the potential to be mounted on a soil penetrometer and deployed for rapid soil profile characterization at field and landscape scales. Details of sensor interaction, efficient data management, and appropriate statistical analysis techniques for model calibrations are first needed. In situ or on-the-go VisNIR spectroscopy has been proposed as a rapid and inexpensive tool for intensively mapping soil texture and organic carbon (SOC). While lab-based VisNIR has been established as a viable technique for estimating various soil properties, few experiments have compared the predictive accuracy of on-the-go and lab-based VisNIR. Eight north central Montana wheat fields were intensively interrogated using on-the-go and lab-based VisNIR. Lab-based spectral data consistently provided more accurate predictions than on-the-go data. However, neither in situ nor lab-based spectroscopy yielded even semi-quantitative SOC predictions. There was little SOC variability to explain across the eight fields, and on-the-go VisNIR was not able to capture the subtle SOC variability in these Montana soils. With more variation in soil clay content compared to SOC, both lab and on-the-go VisNIR showed better explanatory power. There are several potential explanations for poor on-the-go predictive accuracy: soil heterogeneity, field moisture, consistent sample presentation, and a difference between the spatial support of on-the-go measurements and soil samples collected for laboratory analyses. Though the current configuration of a commercially available on-the-go VisNIR system allows for rapid field scanning, on-the-go soil processing (i.e. drying, crushing, and sieving) could improve soil carbon predictions. Laser-induced breakdown spectroscopy (LIBS) is an emerging elemental analysis technology with the potential to provide rapid, accurate and precise analysis of soil constituents, such as carbon, in situ across landscapes. The research team evaluated the accuracy of LIBS for measuring soil profile carbon in field-moist, intact soil cores simulating conditions that might be encountered by a probe-mounted LIBS instrument measuring soil profile carbon in situ. Over the course of three experiments, more than120 intact soil cores from eight north central Montana wheat fields and the Washington State University (WSU) Cook Agronomy Farm near Pullman, WA were interrogated with LIBS for rapid total carbon (TC), inorganic carbon (IC), and SOC determination. Partial least squares regression models were derived and independently validated at field- and regional scales. Researchers obtained the best LIBS validation predictions for IC followed by TC and SOC. Laser-induced breakdown spectroscopy is fundamentally an elemental analysis technique, yet LIBS PLS2 models appeared to discriminate IC from TC. Regression coefficients from initial models suggested a reliance upon stoichiometric relationships between carbon (247.8 nm) and other elements related to total and inorganic carbon in the soil matrix [Ca (210.2 nm, 211.3 nm, and 220.9 nm), Mg (279.55-280.4 nm, 285.26 nm), and Si (251.6 nm, 288.1 nm)]. Expanding the LIBS spectral range to capture emissions from a broader range of elements related to soil organic matter was explored using two spectrometer systems to improve SOC predictions. Results for increasing the spectral range of LIBS to the full 200-800 nm found modest gains in prediction accuracy for IC, but no gains for predicting TC or SOC. Poor SOC predictions are likely a function of (1) the lack of a consistent/definable molecular composition of SOC, (2) relatively little variation in SOC across field sites, and (3) inorganic carbon constituting the primary form of soil carbon, particularly for Montana soils.

54 ENVIRONMENTAL SCIENCES↗

The impact of inverse photoemission spectroscopy measurements on regioregular poly(3-hexylthiophene) films

Inverse photoemission spectroscopy (IPES) enables the characterization of the density of states of unoccupied energy states above the Fermi level. However, due to the relatively high electron currents required to achieve useful signal to noise ratios, sample damage is a concern. Regioregular poly(3-hexylthiophene) (rr-P3HT) was used to systematically study the influence of electron radiation during IPES measurements on a prototypical conductive polymer. A series of IPES measurements exposing the samples to a range of electron fluxes was performed. An analysis of the electronic structure and the morphology showed that significant changes occurred in the investigated samples depending on the electron flux. X-ray diffraction results revealed that the root cause of the spectral changes is most likely related to crystallization of the film in an edge-on orientation. This was confirmed by Raman spectroscopy where both the C-C and C=C stretch modes shifted to lower frequencies after 5 IPES scans indicating a more ordered molecular structure. The observation of these stretch modes even after exposure to higher electron flux indicates that the main chemical structure of the P3HT molecules remains mostly intact during the IPES measurements. The absence of significant changes in C 1s and S 2p photoemission core level lines also confirmed this conclusion.

36 MATERIALS SCIENCE↗

The effect of an on-orbit near encounter on the number flux density of micron sized particles

Many materials and techniques have been developed by the authors to sample the flux of particles in Low Earth Orbit (LEO), and through regular insitu sampling of the flux in LEO, the materials and techniques have produced data which complement the data now being amassed by the Long Duration Exposure Facility (LDEF) research activities. Recent flight experiments on STS-32, STS-44, STS-46, and STS-52 have been conducted to develop an understanding of the spatial density as a function of size (mass) for particle sizes 1x10(exp -6) cm and larger. In addition to the enumeration of particle impacts, it was also the intent of these experiments that hypervelocity particles be captured and returned intact. Measurements were performed post-flight to determine the flux density, diameters, and subsequent effects on various optical, thermal control, and structural materials. During the course of the STS-44 mission, the Space Shuttle corrected its altitude by 26 km to evade a spent upper stage. The results of this near encounter suggests that a cloud of micron sized particles exist in the vicinity of the object. Data also suggest that the flux density is nearly two (2) orders of magnitude higher than background flux. A comparison of the number flux density along with microphotographs of the captured particles will be presented for the referenced shuttle flights.

Maag, Carl R.↗