Equilibrium K-, L-, and M-shell ionizations and charge-state distribution of sulfur projectiles passing through solid targets

In the present work, an alternative approach for the evaluation of the equilibrium K-, L-, and M-shell ionizations and the mean charge state q for projectiles passing through various targets has been proposed. The approach is based on measured K x-ray energy shifts and line intensity ratios and utilizes the theoretical analysis of projectile spectra using multiconfiguration Dirac-Fock calculations. It was applied for the satellite and hypersatellite K lines in the x-ray spectra emitted by sulfur projectiles passing with energies of 9.6-122 MeV through carbon, aluminium, titanium, and iron targets, recorded by a Si(Li) detector. It was found that only in the high projectile energy region there was significant dependence of mean equilibrium K-shell ionization on the target atomic number. The equilibrium L-shell ionization rises with the increase of sulfur energy until 32 MeV, but for higher energies the changes are very weak. The equilibrium M-shell ionization changes very weakly for low projectile energy while for higher energies this ionization is practically constant. For each target, the estimated value of q rises with the increase of the sulfur energy value. The dependence of the sulfur charge state on the target atomic number was discussed by taking into account the cross sections for ionization, decay, and electron capture processes. The data were compared with the experimental data measured by other authors and with the predictions of Shima's and Schiwietz and Grande's semiempirical formulas. The presented good agreement points out that this alternative approach delivers quantitative results.

74 ATOMIC AND MOLECULAR PHYSICS↗

Connecting field ionization to photoionization via 17- and 36-GHz microwave fields

Here we present experimental results connecting field ionization to photoionization in Li Rydberg atoms obtained with 17- and 36-GHz microwave fields. At a low principal quantum number n, where the microwave frequency {omega} is much lower than the classical, or Kepler frequency, {omega}{sub K}=1/n{sup 3}, microwave ionization occurs by field ionization, at E=1/9n{sup 4}. When the microwave frequency exceeds the Kepler frequency, {omega}>1/n{sup 3}, the field required for ionization is independent of n and given by E=2.4{omega}{sup 5/3}, in agreement with dynamic localization models, which cross over to a Fermi's Golden Rule approach at the photoionization limit. A surprising aspect of our results is that when {omega}{approx_equal}1/2n{sup 2}, the one- and multiphoton ionization rates are similar, and even at the lowest microwave powers, all are 10 times lower than the perturbation theory rate calculated for single-photon ionization. Further, we show that when the Rydberg atoms are excited in the presence of the microwave field, the probability of an atom's being bound at the end of the microwave pulse passes smoothly across the limit. This microwave stimulated recombination to bound Rydberg states can be well described by a simple classical model. More generally, these results suggest that the problem of a Rydberg atom coupled to a high-frequency microwave field is similar to the problem of interchannel internal coupling in multilimit atoms, a problem well described by quantum defect theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Angle-resolved and internuclear-separation-resolved measurements of the ionization rate of the B state of I{sub 2} by strong laser fields

Angle-resolved and internuclear-separation-resolved measurements of the single ionization rate of neutral I{sub 2} have been obtained. By launching a wave packet in the B {sup 3}{Pi}{sub u}{sup +} state (B state) of I{sub 2} with a 50-fs tunable pump pulse we can measure the ionization rate as a function of internuclear separation as the wave packet evolves in the B state. Moreover, since the ground to B-state optical transition dipole moment is parallel to the internuclear axis, the B-state subpopulation of the I{sub 2} thermal ensemble will have a high degree of alignment, allowing for angular measurements. The B state shows the well-known effect of enhanced ionization at a critical separation, R{sub c}, with an enhancement factor of 22 when the ionizing field is polarized along the internuclear axis and the enhanced ionization decreases when the angle between the field and the axis increases from 0 deg. to 90 deg., finally disappearing at 90 deg. These results on the enhanced ionization of the B state of I{sub 2} give the most precise determination of R{sub c} for any molecule and agree extremely well with the prediction from a simple model of electron localization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-IeP2-11: Measurement of Equilibrium Doses in Computed Tomography: Comparative Study of Ionization and Solid-State Dosimeters

Purpose: This study aimed to compare equilibrium doses in computed tomography (CT) obtained from ionization and solid-state dosimeters based on the approach presented in the American Association of Physicists in Medicine Report No. 111. The equilibrium doses were also compared with the CT dose index (CTDI) using a 10-cm pencil-type ionization chamber. Methods: A 0.6-cm{sup 3} ionization chamber (10X6-0.6CT) and a solid-state detector (CT Dose Profiler [CTDP]) were calibrated using 80–130 kVp X-ray beams (44.5–55.8 keV of effective energy) from a radiography X-ray machine against a reference ionization dosimeter. Three 16- or 32-cm diameter polymethyl methacrylate (PMMA) phantoms were assembled consecutively on the CT table to obtain equilibrium doses. The 10X6-0.6CT and CTDP were each placed at the center and peripheral holes (12, 3, 6, and 9 o’clock) of the z-center. Central and mean peripheral equilibrium doses were obtained by scanning with longitudinal translation for a length less than the entire phantom length. CTDIs were also obtained with a 10-cm pencil-type ionization chamber (10X6-0.6CT) by scanning a 16- or 32-cm diameter PMMA phantom with one rotation of the X-ray tube. Results: The difference of calibration coefficients between 80 and 130 kVp was 21.1% for the CTDP and 0.7% for the 10X6-0.6CT. The equilibrium doses were higher than the CTDI. Especially at the peripheral positions and 80 kVp, the 10X6-0.6CT showed higher equilibrium doses than CTDP. However, the relation between the equilibrium dose for the 10X6-0.6CT and the CTDP differed depending on the phantom size, scanner type, measurement position, and selected acquisition parameters. Conclusion: The use of a 10-cm pencil-type ionization chamber causes underestimation of the equilibrium dose. The CTDP has a higher energy dependency than the 10X6-0.6CT. The obtained equilibrium doses are different between the 10X6-0.6CT and the CTDP depending on various conditions. This study was supported by JSPS KAKENHI Grant Number 15K09887.

60 APPLIED LIFE SCIENCES↗

Ionization of a multilevel atom by ultrashort laser pulses

Specific features of ionization of single atoms by laser fields of a near-atomic strength are investigated. Calculations are performed for silver atoms interacting with femtosecond laser pulses with wavelengths {lambda} = 800 nm (Ti:Sapphire) and {lambda} = 1.064 {mu}m (Nd:YAG). The dependences of the probability of ionization and of the form of the photoelectron energy spectra on the field of laser pulses for various values of their duration are considered. It is shown that the behavior of the probability of ionization in the range of subatomic laser pulse fields is in good agreement with the Keldysh formula. However, when the field strength attains values close to the atomic field strength, the discrepancies in these dependences manifested in a decrease in the ionization rate (ionization stabilization effect) or in its increase (accelerated ionization) are observed. These discrepancies are associated with the dependence of the population dynamics of excited discrete energy levels of the atom on the laser pulse field amplitude.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dynamics of ionization processes in high-pressure nitrogen, air, and SF{sub 6} during a subnanosecond breakdown initiated by runaway electrons

The dynamics of ionization processes in high-pressure nitrogen, air, and SF{sub 6} during breakdown of a gap with a nonuniform distribution of the electric field by nanosecond high-voltage pulses was studied experimentally. Measurements of the amplitude and temporal characteristics of a diffuse discharge and its radiation with a subnanosecond time resolution have shown that, at any polarity of the electrode with a small curvature radius, breakdown of the gap occurs via two ionization waves, the first of which is initiated by runaway electrons. For a voltage pulse with an ∼500-ps front, UV radiation from different zones of a diffuse discharge is measured with a subnanosecond time resolution. It is shown that the propagation velocity of the first ionization wave increases after its front has passed one-half of the gap, as well as when the pressure in the discharge chamber is reduced and/or when SF{sub 6} is replaced with air or nitrogen. It is found that, at nitrogen pressures of 0.4 and 0.7 MPa and the positive polarity of the high-voltage electrode with a small curvature radius, the ionization wave forms with a larger (∼30 ps) time delay with respect to applying the voltage pulse to the gap than at the negative polarity. The velocity of the second ionization wave propagating from the plane electrode is measured. In a discharge in nitrogen at a pressure of 0.7 MPa, this velocity is found to be ∼10 cm/ns. It is shown that, as the nitrogen pressure increases to 0.7 MPa, the propagation velocity of the front of the first ionization wave at the positive polarity of the electrode with a small curvature radius becomes lower than that at the negative polarity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-low emittance beam generation using two-color ionization injection in a CO 2 laser-driven plasma accelerator

Ultra-low emittance (tens of nm) beams can be generated in a plasma accelerator using ionization injection of electrons into a wakefield. An all-optical method of beam generation uses two laser pulses of different colors. A long-wavelength drive laser pulse (with a large ponderomotive force and small peak electric field) is used to excite a large wakefield without fully ionizing a gas, and a short-wavelength injection laser pulse (with a small ponderomotive force and large peak electric field), co-propagating and delayed with respect to the pump laser, to ionize a fraction of the remaining bound electrons at a trapped wake phase, generating an electron beam that is accelerated in the wake. The trapping condition, the ionized electron distribution, and the trapped bunch dynamics are discussed. Expressions for the beam transverse emittance, parallel and orthogonal to the ionization laser polarization, are presented. An example is shown using a 10-micron CO 2 laser to drive the wake and a frequency-doubled Ti:Al 2 O 3 laser for ionization injection.

43 PARTICLE ACCELERATORS↗

Characterization of a Distributed Plasma Ionization Source (DPIS) for Ion Mobility Spectrometry and Mass Spectrometry

A recently developed atmospheric pressure ionization source, a distributed plasma ionization source (DPIS), was characterized and compared to commonly used atmospheric pressure ionization sources with both mass spectrometry and ion mobility spectrometry. The source consisted of two electrodes of different sizes separated by a thin dielectric. Application of a high RF voltage across the electrodes generated plasma in air yielding both positive and negative ions depending on the polarity of the applied potential. These reactant ions subsequently ionized the analyte vapors. The reactant ions generated were similar to those created in a conventional point-to-plane corona discharge ion source. The positive reactant ions generated by the source were mass identified as being solvated protons of general formula (H2O)nH+ with (H2O)2H+ as the most abundant reactant ion. The negative reactant ions produced were mass identified primarily as CO3-, NO3-, NO2-, O3- and O2- of various relative intensities. The predominant ion and relative ion ratios varied depending upon source construction and supporting gas flow rates. A few compounds including drugs, explosives and environmental pollutants were selected to evaluate the new ionization source. The source was operated continuously for several months and although deterioration was observed visually, the source continued to produce ions at a rate similar that of the initial conditions. The results indicated that the DPIS may have a longer operating life than a conventional corona discharge.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Orientation-dependent enhanced ionization in acetylene revealed by ultrafast cross-polarized pulse pairs

We investigate the orientation dependence of enhanced ionization (EI) during strong-field-driven nuclear motion in acetylene (C 2 ⁢H 2 ). Here, we both initiate and probe molecular dynamics in acetylene with intense 6-fs cross-polarized pulse pairs, separated by a variable delay. Following multiple ionization by the first pulse, acetylene undergoes simultaneous elongation of the carbon-carbon and carbon-hydrogen bonds, enabling further ionization by the second pulse and the formation of a very highly charged state, [C 2 ⁢H 2 ] 6+ . At small interpulse delays (< 20 fs), this enhancement occurs when the molecule is aligned to the probe pulse. Conversely, at large delays (> 40 fs), formation of [C 2 ⁢H 2 ] 6+ occurs when the molecule is aligned to the pump pulse. By analyzing the polarization and time dependence of sequentially ionized [C 2 ⁢H 2 ] 6+ , we resolve two transient alignments that both contribute to a large increase in the multiple ionization yield. In conclusion, this cross-polarized pulse pair scheme uniquely enables selective probing of deeply bound orbitals, providing new insights on orientation-dependent EI in highly charged hydrocarbons.

Atomic & molecular clusters↗

Two-photon above-threshold ionization of helium

Multiphoton ionization provides a clear window into the nature of electron correlations in the helium atom. In the present study, the final-state energy range extends up to the region near the N = 2 and N = 3 ionization thresholds, where two-photon ionization proceeds via continuum intermediate states above the lowest threshold. Our calculations are performed using multichannel quantum defect theory (MQDT) and the streamlined R-matrix method. The sum and integration over all intermediate states in the two-photon ionization amplitude is evaluated using the inhomogeneous R-matrix method developed by Robicheaux and Gao. The seamless connection of that method with MQDT allows us to present high-resolution spectra of the final-state Rydberg resonances. Our analysis classifies the resonances above the N = 2 threshold in terms of their group theory quantum numbers. Furthermore, their dominant decay channels are found to obey the previously conjectured propensity rule far more weakly for these even-parity states than was observed for the odd-parity states relevant to single-photon ionization.

74 ATOMIC AND MOLECULAR PHYSICS↗

Modeling the gain of inner-shell X-ray laser transitions in neon, argon, and copper driven by X-ray free electron laser radiation using photo-ionization and photo-excitation processes

Using an X-ray free electron laser (XFEL) at 960 eV to photo-ionize the 1s electron in neutral neon followed by lasing on the 2p-1s transition in singly-ionized neon, an inner-shell X-ray laser was demonstrated at 849 eV in singly-ionized neon gas several years ago. It took decades to demonstrate this scheme, because it required a very strong X-ray source that could photo-ionize the 1s (K shell) electron in neon on a timescale comparable to the intrinsic Auger lifetime in neon of 2 fs. In this paper, we model the neon inner shell X-ray laser under similar conditions to those used in the XFEL experiments at the SLAC Linac Coherent Light Source (LCLS), and show how we can improve the efficiency of the neon laser and reduce the drive requirements by tuning the XFEL to the 1s-3p transition in neutral neon in order to create gain on the 2p-1s line in neutral neon. We also show how the XFEL could be used to photo-ionize L-shell electrons to drive gain on n = 3–2 transitions in singly-ionized Ar and Cu plasmas. These bright, coherent, and monochromatic X-ray lasers may prove very useful for doing high-resolution spectroscopy and for studying non-linear process in the X-ray regime.

36 MATERIALS SCIENCE↗

Hetero-site Double Core Ionization Energies with Sub-electronvolt Accuracy from Delta-Coupled-Cluster Calculations

Benchmark scalar-relativistic delta-coupled-cluster calculations of hetero-site double core ionization energies of small molecules containing second-row elements are reported. The present study has focused on the high-spin triplet components of two-site double core-ionized states, which are single reference in character and consistent with the use of standard coupledcluster methods. Contributions to computed double core ionization energies from electron-correlation and basis-set effects as well as corrections to the core-valence separation approximation have been analyzed. Furthermore, on the basis of systematic convergence of computational results with respect to these effects, delta-coupled-cluster calculations have been shown to be capable of providing accurate double core ionization energies with remaining errors estimated to be below 0.3 eV, and thus they are recommended for use to facilitate experimental studies of two-site double core-ionized states that are involved in X-ray pump/X-ray probe studies of electronic and molecular dynamics following inner shell ionization or excitation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of Transition Metals in Metal–Organic Frameworks as Nanoporous Ion Emitters for Thermal Ionization Mass Spectrometry

Thermal ionization mass spectroscopy (TIMS) is a powerful analytical technique that allows for precise determination of isotopic ratios. Analysis on low abundance samples, however, can be limited by the ionization efficiency. Following an investigation into a new type of metal-organic hybrid material devised to promote the emission of analyte ions (nano-PIES) and reduce traditional sample loading problems, this work probes the impact that changing the metal in the material has on the ionization of Uranium-238. Being derived from metal-organic frameworks (MOFs), nano-PIEs inherit the tunability of the parent MOFs; the MOF-74 series has been well studied for probing the impact various framework metals (i.e., Mg, Mn, Co, Ni, Cu, Zn, and Cd) have on material properties, and thus, a series of nano-PIEs with different metals were derived from an isoreticular MOF-74 series. In conclusion, trends in ionization efficiency were studied as a function of ionization potential, volatility, and work function of the framework metals as well as the mechanism of ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct measurements of the ionization profile in krypton helicon plasmas

Helicons are efficient plasma sources, capable of producing plasma densities of 10{sup 19} m{sup -3} with only 100 s W of input rf power. There are often steep density gradients in both the neutral density and plasma density, resulting in a fully ionized core a few cm wide surrounded by a weakly ionized plasma. The ionization profile is usually not well known because the neutral density is typically inferred from indirect spectroscopic measurements or from edge pressure gauge measurements. We have developed a two photon absorption laser induced fluorescence (TALIF) diagnostic capable of directly measuring the neutral density profile. We use TALIF in conjunction with a Langmuir probe to measure the ionization fraction profile as a function of driving frequency, magnetic field, and input power. It is found that when the frequency of the driving wave is greater than a critical frequency, f{sub c} Almost-Equal-To 3f{sub lh}, where f{sub lh} is the lower hybrid frequency at the antenna, the ionization fraction is small (0.1%) and the plasma density low (10{sup 17} m{sup -3}). As the axial magnetic field is increased, or, equivalently, the driving frequency decreased, a transition is observed. The plasma density increases by a factor of 10 or more, the plasma density profile becomes strongly peaked, the neutral density profile becomes strongly hollow, and the ionization fraction in the core approaches 100%. Neutral depletion in the core can be caused by a number of mechanisms. We find that in these experiments the depletion is due primarily to plasma pressure and neutral pumping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma effect on fast-electron-impact-ionization from 2p state of hydrogen-like ions

Plasma effects on the high-energy electron-impact ionization process from 2p orbital of Hydrogen-like ions embedded in weakly coupled plasmas are investigated in the first Born approximation. The plasma screening of the Coulomb interaction between charged particles is represented by the Debye Hückel model. The screening of Coulomb interactions decreases the ionization energies and varies the wave functions for not only the bound orbital but also the continuum; the number of the summation for the angular-momentum states in the generalized oscillator strength densities is reduced with the plasma screening stronger when the ratio of ε/I{sub 2p} (I{sub 2p} is the ionization energy of 2p state and ε is the energy of the continuum electron) is kept, and then the contribution from the lower-angular-momentum states dominates the generalized oscillator strength densities, so the threshold phenomenon in the generalized oscillator strength densities and the double differential cross sections are remarkable: The accessional minima, the outstanding enhancement, and the resonance peaks emerge a certain energy region, whose energy position and width are related to the vicinity between δ and the critical value δ{sub nl}{sup c}, corresponding to the special plasma condition when the bound state |nl just enters the continuum; the multiple virtual-state enhancement and the multiple shape resonances in a certain energy domain also appear in the single differential cross section whenever the plasma screening parameter passes through a critical value δ{sub nl}{sup c}, which is similar to the photo-ionization process but different from it, where the dipole transition only happens, but multi-pole transition will occur in the electron-impact ionization process, so its multiple virtual-state enhancements and the multiple shape resonances appear more frequently than the photo-ionization process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of ionized metal flux in enhanced high power impulse magnetron sputtering discharges

The metal ionized flux fraction and production of double charged metal ions Me{sup 2+} of different materials (Al, Cu, Fe, Ti) by High Power Impulse Magnetron Sputtering (HiPIMS) operated with and without a pre-ionization assistance is compared in the paper. The Electron Cyclotron Wave Resonance (ECWR) discharge was employed as the pre-ionization agent providing a seed of charge in the idle time of HiPIMS pulses. A modified grid-free biased quartz crystal microbalance was used to estimate the metal ionized flux fraction ξ. The energy-resolved mass spectrometry served as a complementary method to distinguish particular ion contributions to the total ionized flux onto the substrate. The ratio between densities of doubly Me{sup 2+} and singly Me{sup +} charged metal ions was determined. It is shown that ECWR assistance enhances Me{sup 2+} production with respect of absorbed rf-power. The ECWR discharge also increases the metal ionized flux fraction of about 30% especially in the region of lower pressures. Further, the suppression of the gas rarefaction effect due to enhanced secondary electron emission of Me{sup 2+} was observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamics of ionization-induced electron injection in the high density regime of laser wakefield acceleration

The dynamics of ionization-induced electron injection in high density (∼1.2 × 10{sup 19} cm{sup −3}) regime of laser wakefield acceleration is investigated by analyzing the betatron X-ray emission. In such high density operation, the laser normalized vector potential exceeds the injection-thresholds of both ionization-injection and self-injection due to self-focusing. In this regime, direct experimental evidence of early on-set of ionization-induced injection into the plasma wave is given by mapping the X-ray emission zone inside the plasma. Particle-In-Cell simulations show that this early on-set of ionization-induced injection, due to its lower trapping threshold, suppresses the trapping of self-injected electrons. A comparative study of the electron and X-ray properties is performed for both self-injection and ionization-induced injection. An increase of X-ray fluence by at least a factor of two is observed in the case of ionization-induced injection due to increased trapped charge compared to self-injection mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ionization and photofragmentation of Ru{sub 3}(CO){sub 12} and Os{sub 3}(CO){sub 12}

In this paper, we use a combination of photoelectron spectroscopy, mass spectrometry, and density functional theory calculations to get a detailed understanding of valence single and double ionization and the subsequent dissociation processes. This is exemplified on benchmark systems, trimetallo-dodecacarbonyls M{sub 3}(CO){sub 12} with M = Ru, Os, where the energy remaining in the molecule after photoionization can be retrieved by measuring the degree of fragmentation of the molecular ion. The intensity of different mass peaks can thus be directly related to ionization cross sections obtained by photoelectron spectroscopy. We find that the M—CO dissociation energy rises as the number of CO ligands decreases due to dissociation. Moreover, ionization of the CO ligands has a higher cross section than that of the metal center for both single and double ionization. After advanced fragmentation, a CO bond can break and the carbon atom remains bonded to the metal core. In addition, we found that the valence ionization cross sections of M{sub 3}(CO){sub 12} are maximal at about 40 eV photon energy thus showing a more pronounced shape resonance than Ru and Os-complexes with a single metal atom center. Finally, an np → nd giant resonance absorption causes a significant increase of the ionization cross section above 50 eV for Ru{sub 3}(CO){sub 12}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗