Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

DACOM - A rapid, high sensitivity airborne carbon monoxide monitor

A rapid, high sensitivity differential absorption carbon monoxide monitor (DACOM) has been developed to measure CO from an aircraft. The differential absorption measurement is accomplished by rapidly current tuning the wavelength of a PbSSe diode laser across a single 4.7 micron CO absorption line. As the laser wavelength sweeps periodically across the absorption line, the laser beam is amplitude modulated and is then synchronously detected. With this technique a minimum detectable differential transmission of 0.02% is obtained for a 1 second integration time. This performance is equivalent to a CO sensitivity of 5 ppb for a 10 meter absorption path. The techniques used to achieve this high sensitivity will be discussed. In the aircraft installation a 10 meter absorption path is located in the airstream along the fuselage of a C-54 aircraft. During flight tests of DACOM, a sensitivity of 20 ppb for a 1-second integration time has been achieved.

Sachse, G. W.↗

Ellipsometric study of YBa2Cu3O(7-x) laser ablated and co-evaporated films

High temperature superconducting films of YBa2Cu3O(7-x) (YBCO were grown on SrTiO3, LaA1O3, and YSZ substrates using two techniques: excimer laser ablation with in situ annealing and co-evaporation of Y, Cu, and BaF2 with ex-situ annealing. Film thicknesses were typically 5000 A, with predominant c-axis alignment perpendicular to the substrate. Critical temperatures up to Tc(R=O)=90 K were achieved by both techniques. Ellipsometric measurements were taken in the range 1.6 to 4.3 eV using a variable angle spectroscopic ellipsometer. The complex dielectric function of the laser ablated films was reproducible from run to run, and was found to be within 10 percent of that previously reported for (001) oriented single crystals. A dielectric overlayer was observed in these films, with an index of refraction of approximately 1.55 and nearly zero absorption. For the laser ablated films the optical properties were essentially independent of substrate material. The magnitude of the dielectric function obtained for the co-evaported films was much lower than the value reported for single crystals, and was sample dependent.

Alterovitz, S. A.↗

Ellipsometric study of YBa2Cu3O(7-x) laser ablated and co-evaporated films

High temperature superconducting films of YBa2Cu3O(7-x) (YBCO) were grown on SrTiO3, LaAl03, and YSZ substrates using two techniques: excimer laser ablation with in situ annealing and co-evaporation of Y, Cu, and BaF2 with ex-situ annealing. Film thicknesses were typically 5000 A, with predominant c-axis alignment perpendicular to the substrate. Critical temperatures up to Tc(R = 0) = 90 K were achieved by both techniques. Ellipsometric measurements were taken in the range 1.6 to 4.3 eV using a variable angle spectroscopic ellipsometer. The complex dielectric function of the laser ablated films was reproducible from run to run, and was found to be within 10 percent of that previously reported for (001) oriented single crystals. A dielectric overlayer was observed in these films, with an index of refraction of approximately 1.55 and nearly zero absorption. For the laser ablated films the optical properties were essentially independent of substrate material. The magnitude of the dielectric function obtained for the co-evaporated films was much lower than the value reported for single crystals, and was sample dependent.

Alterovitz, S. A.↗

A tunable dual frequency dye laser - dual frequency oscillator design

The pulsed dye laser offers a tunable oscillator, followed by three amplifiers. It is pumped by a dual frequency Nd:YAG laser. Tuning and spectral width are controlled by a holographic network connected to a high power telescope. The modified two wavelength dye laser allows for absorption lidar techniques for remote sensing of the atmosphere. Line switching is achieved by electrooptical commutation. A feasibility experiment was performed with the original oscillator. A model was then built, and tested with different dyes. After a few modifications were made to improve the conversion efficiency, this oscillator was inserted in the laser to check whether the amplifier stages were correctly adjusted.

Abury, Y.↗

Saturation Phenomena in LIF Measurements, Appendix B

Optical saturation is the phenomenon in which the laser-induced rates of absorption and spontaneous emission between two levels, induced by a laser, become comparable to or greater than the spontaneous emission and collision rates connecting these levels. This results in the excited state population N(u) acquiring a value of similar magnitude to that of the ground state, N(e). Under these conditions the observed fluorescence signal, which is proportional to N(u), is no longer linearly dependent on laser intensity I, but increases at a slower rate, and in principle ultimately becomes independent of I. A conceptual picture of optical saturation using a two-level picture is described. This is, however, inadequate for the description of a real experiment involving a molecule, such as OH, for several reasons, which will be explained briefly; these are the multi-level nature of the electronic states and energy transfer among them and effects due to spatial, spectral, and temporal fluctuations in the laser pulse.

Source record↗

A Compact Ti:Sapphire Laser With its Third Harmonic Generation (THG) for an Airborne Ozone Differential Absorption Lidar (DIAL) Transmitter

A compact and high-pulse-energy Ti:Sapphire laser with its Third Harmonic Generation (THG) has been developed for an airborne ozone differential absorption lidar (DIAL) to study the distributions and concentrations of the ozone throughout the troposphere. The Ti:Sapphire laser, pumped by a frequency-doubled Nd:YAG laser and seeded by a single mode diode laser, is operated either at 867 nm or at 900 nm with a pulse repetition frequency of 20 Hz. High energy laser pulses (more than 110 mJ/pulse) at 867 nm or 900 nm with a desired beam quality have been achieved and utilized to generate its third harmonic at 289nm or 300nm, which are on-line and off-line wavelengths of an airborne ozone DIAL. After being experimentally compared with Beta-Barium Borate (beta - BaB2O4 or BBO) nonlinear crystals, two Lithium Triborate (LBO) crystals (5 x 5 x 20 cu mm) are selected for the Third Harmonic Generation (THG). In this paper, we report the Ti:Sapphire laser at 900 nm and its third harmonic at 300 nm. The desired high ultraviolet (UV) output pulse energy is more than 30 mJ at 300 nm and the energy conversion efficiency from 900 nm to 300 nm is 30%.

Chen, Songsheng↗

Atmospheric transmission of CO2 laser radiation with application to laser Doppler systems

The molecular absorption coefficients of carbon dioxide, water vapor, and nitrous oxide are calculated at the P16, P18, P20, P22, and P24 lines of the CO2 laser for temperatures from 200 to 300 K and for pressures from 100 to 1100 mb. The temperature variation of the continuum absorption coefficient of water vapor is taken into account semi-empirically from Burch's data. The total absorption coefficient from the present calculations falls within + or - 20 percent of the results of McClatchey and Selby. The transmission loss which the CO2 pulsed laser Doppler system experiences was calculated for flight test conditions for the five P-lines. The total transmission loss is approximately 7 percent higher at the P16 line and 10 percent lower at the P24 line compared to the P20 line. Comparison of the CO2 laser with HF and DF laser transmission reveals the P2(8) line at 3.8 micrometers of the DF laser is much better from the transmission point of view for altitudes below 10 km.

Murty, S. S. R.↗

Residual infrared absorption in Ti:Al2O3 crystals

The performance of Ti:Al2O3 lasers is impaired generally by an infrared absorption that occurs in the laser output wavelength region. On the basis of data for as-grown and annealed samples cut from Ti:Al2O3 crystals grown by the vertical-gradient-freeze (VGF) technique, we previously proposed that the residual absorption is due to Ti(3+) to Ti(4+) pairs. In this report, we present additional data that confirm this ion-pair model for the residual absorption, which can be attributed to excitation of the 3d electron of the Ti(3+) ion perturbed by the Coulomb field of the neighboring Ti(4+) ion and/or an associated Al vacancy.

Source record↗

Calibrating Laser Gas Measurements by Use of Natural CO2

An improved method of calibration has been devised for instruments that utilize tunable lasers to measure the absorption spectra of atmospheric gases in order to determine the relative abundances of the gases. In this method, CO2 in the atmosphere is used as a natural calibration standard. Unlike in one prior calibration method, it is not necessary to perform calibration measurements in advance of use of the instrument and to risk deterioration of accuracy with time during use. Unlike in another prior calibration method, it is not necessary to include a calibration gas standard (and the attendant additional hardware) in the instrument and to interrupt the acquisition of atmospheric data to perform calibration measurements. In the operation of an instrument of this type, the beam from a tunable diode laser or a tunable quantum-cascade laser is directed along a path through the atmosphere, the laser is made to scan in wavelength over an infrared spectral region that contains one or two absorption spectral lines of a gas of interest, and the transmission (and, thereby, the absorption) of the beam is measured. The concentration of the gas of interest can then be calculated from the observed depth of the absorption line(s), given the temperature, pressure, and path length. CO2 is nearly ideal as a natural calibration gas for the following reasons: CO2 has numerous rotation/vibration infrared spectral lines, many of which are near absorption lines of other gases. The concentration of CO2 relative to the concentrations of the major constituents of the atmosphere is well known and varies slowly and by a small enough amount to be considered constant for calibration in the present context. Hence, absorption-spectral measurements of the concentrations of gases of interest can be normalized to the concentrations of CO2. Because at least one CO2 calibration line is present in every spectral scan of the laser during absorption measurements, the atmospheric CO2 serves continuously as a calibration standard for every measurement point. Figure 1 depicts simulated spectral transmission measurements in a wavenumber range that contains two absorption lines of N2O and one of CO2. The simulations were performed for two different upper-atmospheric pressures for an airborne instrument that has a path length of 80 m. The relative abundance of CO2 in air was assumed to be 360 parts per million by volume (approximately its natural level in terrestrial air). In applying the present method to measurements like these, one could average the signals from the two N2O absorption lines and normalize their magnitudes to that of the CO2 absorption line. Other gases with which this calibration method can be used include H2O, CH4, CO, NO, NO2, HOCl, C2H2, NH3, O3, and HCN. One can also take advantage of this method to eliminate an atmospheric-pressure gauge and thereby reduce the mass of the instrument: The atmospheric pressure can be calculated from the temperature, the known relative abundance of CO2, and the concentration of CO2 as measured by spectral absorption. Natural CO2 levels on Mars provide an ideal calibration standard. Figure 2 shows a second example of the application of this method to Mars atmospheric gas measurements. For sticky gases like H2O, the method is particularly powerful, since water is notoriously difficult to handle at low concentrations in pre-flight calibration procedures.

Webster, Chris↗

Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space

Measurements of tropospheric CO2 abundance with global-coverage, a few hundred km spatial and monthly temporal resolution are needed to quantify processes that regulate CO2 storage by the land and oceans. The Orbiting Carbon Observatory (OCO) is the first space mission focused on atmospheric CO2 for measuring total column CO, and O2 by detecting the spectral absorption in reflected sunlight. The OCO mission is an essential step, and will yield important new information about atmospheric CO2 distributions. However there are unavoidable limitations imposed by its measurement approach. These include best accuracy only during daytime at moderate to high sun angles, interference by cloud and aerosol scattering, and limited signal from CO2 variability in the lower tropospheric CO2 column. We have been developing a new laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our initial goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft. Our final goal is to develop a space instrument and mission approach for active measurements of the CO2 mixing ratio at the 1-2 ppmv level. Our technique is much less sensitive to cloud and atmospheric scattering conditions and would allow continuous measurements of CO2 mixing ratio in the lower troposphere from orbit over land and ocean surfaces during day and night. Our approach is to use the 1570nm CO2 band and a 3-channel laser absorption spectrometer (i.e. lidar used an altimeter mode), which continuously measures at nadir from a near polar circular orbit. The approach directs the narrow co-aligned laser beams from the instrument's lasers toward nadir, and measures the energy of the laser echoes reflected from land and water surfaces. It uses several tunable fiber laser transmitters which allowing measurement of the extinction from a single selected CO2 absorption line in the 1570 nm band. This band is free from interference from other gases and has temperature insensitive absorption lines. During the measurement the lasers are tuned on- and off- a selected CO2 line near 1572 nm and a selected O2 line near 768 nm in the Oxygen A band at kHz rates. The lasers use tunable diode seed lasers followed by fiber amplifiers, and have spectral widths much narrower than the gas absorption lines. The receiver uses a 1-m diameter telescope and photon counting detectors and measures the background light and energies of the laser echoes from the surface. The extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on and offline surface echo via the differential optical absorption technique. Our technique rapidly alternates between several on-line wavelengths set to the sides of the selected gas absorption lines. It exploits the atmospheric pressure broadening of the lines to weight the measurement sensitivity to the atmospheric column below 5 km. This maximizes sensitivity to CO2 in the boundary layer, where variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column will use an identical approach with an O2 line. Thee laser frequencies are tunable and have narrow (MHz) line widths. In combination with sensitive photon counting detectors these enables much higher spectral resolution and precision than is possible with passive spectrometer. 1aser backscatter profiles are also measured, which permits identifying measurements made to cloud tops and through aerosol layers. The measurement approach using lasers in common-nadir-zenith path allows retrieving CO2 column mixing ratios in the lower troposphere irrespective of sun angle. Pulsed laser signals, time gated receiver and a narrow receiver field-of-view are used to isolate the surface laser echo signals and to exclude photons scattered from clouds and aerosols. Nonetheless, the optical absorption change due to a change of a few ppO2 is small, <1 % which makes achieving the needed measurement sensitivities and stabilities quite challenging. Measurement SNRs and stabilities of >600:1 are needed to estimate CO2 mixing ratio at the 1-2 ppm level. We have calculated characteristics of the technique and have demonstrated aspects of the laser, detector and receiver approaches in th e laboratory We have also measured O2 in an absorption cell, and made C02 measurements over a 400 m long (one way) horizontal path using a sensor breadboard. We will describe these and more details of our approach in the paper.

Abshire, James B.↗

Analytical studies of ultrashort optical pulse propagation in a resonant absorbing medium

Resonant absorption in a laser pulse can be reduced to zero if the trailing part induces stimulated emission and returns the absorbed energy back to the pulse. This kind of effect is called Self-Induced Transparency (SIT). Analytic descriptions of short pulse propagation in a resonant medium, based on Slowly Varying Envelope Approximation (SVEA) and in linear media, have been extended in studies of SIT along two principal directions: First, to improve the SVEA by introducing Short Pulse Approximation (SPA); and second, to consider the effect of nonlinear refractive index.

Lee, C. T.↗

Uniformity of Ludwieg tube flows

Pressure and speed of sound measurements are used to obtain averaged gas properties in a Ludwieg combustion tube in which the gas is burned just prior to use. Absorption of a laser beam in the exit flow is used to check the predicted temperature uniformity. The burning process and the heat transfer to the cold walls are modeled. Interferograms of Ludwieg tube boundary layers are utilized to develop a new semiempirical boundary layer expression referred to as the integral density thickness, which is then applied to a recently developed linearized analysis of the effects of this layer. Pressure-time histories are determined for a wide range of tube flow Mach number and aspect ratio. Viscous and nonviscous effects are considered. It is shown that although the influence of the integral density thickness on the flow can be large, a modified linear theory can be used to estimate the effects for arbitrary tube flow Mach number and values of the aspect ratio that include cases where the boundary layers have merged.

Russell, D. A.↗

Direct observation of interface instability during crystal growth

The general aim of this investigation was to study interface stability and solute segregation phenomena during crystallization of a model system. Emphasis was to be placed on direct observational studies partly because this offered the possibility at a later stage of performing related experiments under substantially convection-free conditions in the space shuttle. The major achievements described in this report are: (1) the development of a new model system for fundamental studies of crystal growth from the melt and the measurement of a range of material parameters necessary for comparison of experiment with theory. (2) The introduction of a new method of measuring segregation coefficient using absorption of a laser beam by the liquid phase. (3) The comparison of segregation in crystals grown by gradient freezing and by pulling from the melt. (4) The introduction into the theory of solute segregation of an interface field term and comparison with experiment. (5) The introduction of the interface field term into the theories of constitutional supercooling and morphological stability and assessment of its importance.

Tiller, W. A.↗

Advanced smoke meter development survey and analysis

Ideal smoke meter characteristics are determined to provide a basis for evaluation of candidate systems. Five promising techniques are analyzed in detail to evaluate compilance with the practical smoke meter requirements. Four of the smoke measurement concepts are optical methods: Modulated Transmission (MODTRAN), Cross Beam Absorption Counter (CBAC), Laser Induced Incandescence (LIN), and Photoacoustic Spectroscopy (PAS). A rapid response filter instrument called a Taper Element Oscillating Microbalance (TEOM) is also evaluated. For each technique, the theoretical principles are described, the expected performance is determined, and the advantages and disadvantages are discussed The expected performance is evaluated against each of the smoke meter specifications, and the key questions for further study are given. The most promising smoke meter technique analyzed was MODTRAN, which is a variation on a direct transmission measurement. The soot-laden gas is passed through a transmission cell, and the gas pressure is modulated by a speaker.

Pitz, R. W.↗

Mobile lidar system for measurement of water vapor mixing ratio and ozone number density

The Water Vapor Lidar was modified and extended to make differential absorption measurements of ozone. Water vapor measurements make use of a weak molecular scattering process known as Raman scattering. It is characterized by a shift in wavelength of the scattered beam of light relative to the incident one. Some of the energy of the incident photon is converted to vibrational or rotational energy within the molecule leaving the scattered photon shifted to a slightly longer wavelength. When performing water vapor measurements, profiles are acquired of water vapor mixing ratio from near the ground to beyond 7 km every 2 minutes. By forming a color composite image of the individual profiles, the spatial and temporal evolution of water vapor is visible with vertical resolution of 75 to 150m and temporal resolution of 2 minutes. The ozone lidar is intended for use as a cross calibration facility for other stationary ozone lidar systems. The ozone measurement employs the technique known as differential absorption. The backscattered laser radiation from two different wavelengths is measured. Successful measurements of 308 nm returns were made from 80 km with an averaging period of 6 hours. Using these data and a standard atmosphere density curve, an ozone number density profile was made which agrees very well with the standard ozone curve between 20 and 40 km.

Whiteman, D.↗

A conceptual design study for the EOS Lidar Atmospheric Sounder and Altimeter facility

A preliminary design study is presented for the Lidar Atmospheric Sounder and Altimeter (LASA), an active remote sensor for the Earth Observing System. LASA is designed to measure the global vertical distributions of aerosols, cloud top heights, atmospheric trace gases, atmospheric temperature and pressure, and the height of the PBL. The measurements are made using optical radar, differential absorption lidar, and laser altimetry. An experiment proposed for the LASA facility, the EOS Atmospheric Global Lidar Experiment (EAGLE) is described in detail. The EAGLE program is planned to determine aerosol and cloud distributions, water vapor concentrations, and temperature profiles over the troposphere and aerosol distribution over the stratosphere. The measurement techniques, receiver system, and transmitter for the EAGLE program are examined and the conceptual design of the EAGLE experiment and the LASA/EAGLE interface is outlined.

Mauldin, Lemuel E., III↗