Search NASA⌕ Search

SEARCH · Search NASA

Results for “limiting techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Resolve survey photometry and volume-limited calibration of the photometric gas fractions technique

We present custom-processed ultraviolet, optical, and near-infrared photometry for the REsolved Spectroscopy of a Local VolumE (RESOLVE) survey, a volume-limited census of stellar, gas, and dynamical mass within two subvolumes of the nearby universe (RESOLVE-A and RESOLVE-B). RESOLVE is complete down to baryonic mass ∼10{sup 9.1−9.3} M{sub ⊙}, probing the upper end of the dwarf galaxy regime. In contrast to standard pipeline photometry (e.g., SDSS), our photometry uses optimal background subtraction, avoids suppressing color gradients, and employs multiple flux extrapolation routines to estimate systematic errors. With these improvements, we measure brighter magnitudes, larger radii, bluer colors, and a real increase in scatter around the red sequence. Combining stellar mass estimates based on our optimized photometry with the nearly complete H i mass census for RESOLVE-A, we create new z = 0 volume-limited calibrations of the photometric gas fractions (PGF) technique, which predicts gas-to-stellar mass ratios (G/S) from galaxy colors and optional additional parameters. We analyze G/S-color residuals versus potential third parameters, finding that axial ratio is the best independent and physically meaningful third parameter. We define a “modified color” from planar fits to G/S as a function of both color and axial ratio. In the complete galaxy population, upper limits on G/S bias linear and planar fits. We therefore model the entire PGF probability density field, enabling iterative statistical modeling of upper limits and prediction of full G/S probability distributions for individual galaxies. These distributions have two-component structure in the red color regime. Finally, we use the RESOLVE-B 21 cm census to test several PGF calibrations, finding that most systematically under- or overestimate gas masses, but the full probability density method performs well.

79 ASTRONOMY AND ASTROPHYSICS↗

Criticality hazard identification technique for development of safe operating limits and restrictions - 14367

Canadian Nuclear Laboratories' (CNL) National Research Universal (NRU) reactor located at Chalk River Laboratories (CRL) first attained criticality in 1957. Outside of the reactor core, the safe handling and storage of fissile material including experimental fuel components is required to support NRU's ongoing missions of research and medical isotope production [1]. Management of this fissionable material relies heavily on experienced operating staff, who perform work in accordance with a defined set of limits and restrictions as laid out in a Criticality Safety Document (CSD). Historically, the development of CSDs has relied heavily upon criticality safety analysts to gain sufficient knowledge about the facility. This has resulted in significant labor costs due to heavy use of computational methods. This paper describes a new approach for CNL to identify potential criticality scenarios, a 'Criticality Hazard Identification' (CHI) technique, developed from traditional process-oriented hazard and operability analysis, to identify and define operating conditions, identify limits and restrictions for the handling of fissionable materials outside of the core. The approach permits thorough evaluation of potential criticality hazards, for both well-understood historical and proposed future activities, by better leveraging the knowledge of operations personnel as well as other subject matter experts. The resulting document provides a detailed record of the various scenarios that were considered. These improvements to the CSD development and documentation process provide an additional benefit in terms of ease of modification to include new or changed activities within the limits and conditions. (authors)

42 ENGINEERING↗

“Development and application of analytical detection techniques for droplet-based microfluidics”-A review

Droplet-based microfluidics has emerged as a powerful platform for high-throughput and low-volume analysis and screening. At present, droplet-based microfluidics is transitioning from the proof-of-concept stage to real-world applications. During this process, analytical detection techniques play indispensable roles for successfully implementing droplet-based chemical or biological assays. Here, we provide an overview of recent developments in analytical techniques for droplet analysis and elucidate the advantages and limitations of each technique. We cover the majority of technology categories, including optical detection, electrical detection, mass spectrometry, and nuclear magnetic resonance spectroscopy. Additionally, we highlight new research areas that have been enabled by these technical advances. Finally, we provide perspectives on both future technological directions and potential enabling applications.

47 OTHER INSTRUMENTATION↗

Middle Atmosphere Program. Handbook for MAP, volume 19

This MAP handbook is concerned with rocket techniques and instrumentation as they are currently employed in the middle atmosphere. It is composed of nine chapters, written by experts on rocket experiments. The emphasis is on measurement techniques rather than results, although results are incorporated wherever they provide examples which illustrate the measurement features. The chapters first cover techniques relating to measurements of neutral dynamics and chemistry, then measurements of the various intermittent and excessive radiation sources which effect the middle atmospheric environment, and finally measurements of the plasma environment including electric fields. The weighting toward plasma related parameters is not accidental, but reflects both the historical headstart given by early development of radio wave and probe techniques to measure electron density, and by the relatively limited number of techniques available for neutral atmospheric measurements.

Goldberg, R. A.↗

Cosmic Ray Energy Determination by the Reduced-Opening Angle Method

Accurate measurement of the primary galactic cosmic ray species energy dependence in the regime beyond approx. 500 GeV/a is difficult due to the low flux and the limitations of energy measurement techniques. However, such observations are essential to resolve several questions of current interest such as: Is the enrichment of heavy species (Z greater that or equal to 6) cosmic rays first reported at higher energies by the proton satellite' and then later at lower energies real? The results from a previous deployment of the reduced opening angle technique are inconclusive but the authors do point to limitations in the previous techniques. Another intriguing puzzle is the energy dependence of silicon cosmic rays. Two independent experiments using different experimental techniques indicate that silicon is under-abundant. At present the observation is limited by statistics; it could still be a three sigma fluctuation. However, if confirmed the current models of acceleration and propagation which are species independent are seriously inadequate. To progress further the species and energy dependence must be accurately measured in a manner that is free from systematic uncertainty. In this report we show that the reduced opening angle method offers a simple and relatively inexpensive method to answer these questions. First we present the physics of the reduced opening angle and indicate the expected energy and charge resolution. The proposed detector design is then presented followed by the expected performance. Where ever possible simple phenomenological expressions that allow 'back of the envelope' estimates are given. More details are presented in the appendices. The limit of the energy resolution and the expected event rates for iron cosmic rays are calculated. Salient points are summarized in the conclusions.

Smith, Arthur E.↗

On the derivation of empirical limits on the helium abundance in coronal holes below 1.5 solar radius

We present a simple technique describing how limits on the helium abundance, alpha, defined as the ratio of helium to proton number density, can be inferred from measurements of the electron density and temperature below 1.5 solar radius. As an illustration, we apply this technique to two different data sets: emission-line intensities in the extreme ultraviolet (EUV) and white-light observations, both measured in polar coronal holes. For the EUV data, the temperature gradient is derived from line intensity ratios, and the density gradient is replaced by the gradient of the line intensity. The lower limit on alpha derived from these data is 0.2-0.3 at 1 solar radius and drops very sharply to interplanetary values of a few percent below 1.06 solar radius. The white-light observations yield density gradients in the inner corona beyond 1.25 solar radius but do not have corresponding temperature gradients. In this case we consider an isothermal atmosphere, and derive an upper limit of 0.2 for alpha. These examples are used to illustrate how this technique could be applicable to the more extensive data to be obtained with the upcoming SOHO mission. Although only ranges on alpha can be derived, the application of the technique to data currently available merely points to the fact that alpha can be significantly large in the inner corona.

Habbal, Shadia Rifai↗

Towards an integrated materials characterization toolbox

The material characterization toolbox has recently experienced a number of parallel revolutionary advances, foreshadowing a time in the near future when material scientists can quantify material structure evolution across spatial and temporal space simultaneously. This will provide insight to reaction dynamics in four-dimensions, spanning multiple orders of magnitude in both temporal and spatial space. This study presents the authors’ viewpoint on the material characterization field, reviewing its recent past, evaluating its present capabilities, and proposing directions for its future development. Electron microscopy; atom probe tomography; x-ray, neutron and electron tomography; serial sectioning tomography; and diffraction-based analysis methods are reviewed, and opportunities for their future development are highlighted. Advances in surface probemicroscopy have been reviewed recently and, therefore, are not included [D.A.Bonnell et al.: Rev.Modern Phys. in Review]. In this study particular attention is paid to studies that have pioneered the synergetic use of multiple techniques to provide complementary views of a single structure or process; several of these studies represent the stateof- the-art in characterization and suggest a trajectory for the continued development of the field. Based on this review, a set of grand challenges for characterization science is identified, including suggestions for instrumentation advances, scientific problems in microstructure analysis, and complex structure evolution problems involving material damage. The future of microstructural characterization is proposed to be one not only where individual techniques are pushed to their limits, but where the community devises strategies of technique synergy to address complex multiscale problems in materials science and engineering.

characterization↗

Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits

Breath analysis, a promising new field of medicine and medical instrumentation, potentially offers noninvasive, real-time, and point-of-care (POC) disease diagnostics and metabolic status monitoring. Numerous breath biomarkers have been detected and quantified so far by using the GC-MS technique. Recent advances in laser spectroscopic techniques and laser sources have driven breath analysis to new heights, moving from laboratory research to commercial reality. Laser spectroscopic detection techniques not only have high-sensitivity and high-selectivity, as equivalently offered by the MS-based techniques, but also have the advantageous features of near real-time response, low instrument costs, and POC function. Of the approximately 35 established breath biomarkers, such as acetone, ammonia, carbon dioxide, ethane, methane, and nitric oxide, 14 species in exhaled human breath have been analyzed by high-sensitivity laser spectroscopic techniques, namely, tunable diode laser absorption spectroscopy (TDLAS), cavity ringdown spectroscopy (CRDS), integrated cavity output spectroscopy (ICOS), cavity enhanced absorption spectroscopy (CEAS), cavity leak-out spectroscopy (CALOS), photoacoustic spectroscopy (PAS), quartz-enhanced photoacoustic spectroscopy (QEPAS), and optical frequency comb cavity-enhanced absorption spectroscopy (OFC-CEAS). Spectral fingerprints of the measured biomarkers span from the UV to the mid-IR spectral regions and the detection limits achieved by the laser techniques range from parts per million to parts per billion levels. Sensors using the laser spectroscopic techniques for a few breath biomarkers, e.g., carbon dioxide, nitric oxide, etc. are commercially available. This review presents an update on the latest developments in laser-based breath analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Properties of vapor-deposited and solution-processed targets for laser-driven inertial confinement fusion experiments

Targets for low-adiabat direct-drive-implosion experiments on OMEGA must meet rigorous specifications and tight tolerances on the diameter, wall thickness, wall-thickness uniformity, and presence of surface features. Of these, restrictions on the size and number of defects (bumps and depressions) on the surface are the most challenging. The properties of targets that are made using vapor-deposition and solution-based microencapsulation techniques are reviewed. Targets were characterized using confocal microscopy, bright- and dark-field microscopy, atomic force microscopy, electron microscopy, and interferometry. Each technique has merits and limitations, and a combination of these techniques is necessary to adequately characterize a target. The main limitation with the glow-discharge polymerization (GDP) method for making targets is that it produces hundreds of domes with a lateral dimension of 0.7–2 μm. Polishing these targets reduces the size of some but not all domes, but it adds scratches and grooves to the surface. Solution-made polystyrene shells lack the dome features of GDP targets but have hundreds of submicrometer-size voids throughout the wall of the target; a few of these voids can be as large as ∼12 μm at the surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noninvasive Synchrotron-Based X-ray Raman Scattering Discriminates Carbonaceous Compounds in Ancient and Historical Materials [ In situ synchrotron-based X-Ray Raman scattering discriminates carbonaceous compounds in ancient and historical materials]

Carbon compounds are ubiquitous and occur in a diversity of chemical forms in many systems including ancient and historic materials ranging from cultural heritage to paleontology. Determining their speciation cannot only provide unique information on their origin but may also elucidate degradation processes. Synchrotron-based X-ray absorption near-edge structure (XANES) spectroscopy at the carbon K-edge (280–350 eV) is a very powerful method to probe carbon speciation. However, the short penetration depth of soft X-rays imposes stringent constraints on sample type, preparation, and analytical environment. A hard X-ray probe such as X-ray Raman scattering (XRS) can overcome many of these difficulties. Here we report the use of XRS at ~6 keV incident energy to collect carbon K-edge XANES data and probe the speciation of organic carbon in several specimens relevant to cultural heritage and natural history. This methodology enables the measurement to be done in a nondestructive way, in air, and provides information that is not compromised by surface contamination by ensuring that the dominant signal contribution is from the bulk of the probed material. Using the backscattering geometry at large photon momentum transfer maximizes the XRS signal at the given X-ray energy and enhances nondipole contributions compared to conventional XANES, thereby augmenting the speciation sensitivity. The capabilities and limitations of the technique are discussed. As a result, we show that despite its small cross section, for a range of systems the XRS method can provide satisfactory signals at realistic experimental conditions. XRS constitutes a powerful complement to FT-IR, Raman, and conventional XANES spectroscopy, overcoming some of the limitations of these techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparative study on the optical limiting properties of different nano spinel ferrites with Z-scan technique

Highlights: ► First report in which the optical limiting properties of five different nano spinel ferrites are compared. ► The obtained nonlinearity fits to a two-photon like absorption process. ► Except for NiFe{sub 2}O{sub 4}, the observed nonlinearity has contributions from excited state absorption. ► A size dependent optical limiting response is obtained. ► Among the investigated ferrites, ZnFe{sub 2}O{sub 4} is found to be a better candidate for the optical limiting applications. -- Abstract: We report the optical limiting properties of five different spinel ferrites, NiFe{sub 2}O{sub 4}, Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4}, ZnFe{sub 2}O{sub 4}, Ni{sub 0.5}Co{sub 0.5}Fe{sub 2}O{sub 4}, and CoFe{sub 2}O{sub 4} with an average particle grain size of 8 nm. The optical limiting properties are investigated using the open aperture Z-scan technique. The obtained nonlinearity fits to a two-photon like absorption process. Except for NiFe{sub 2}O{sub 4}, the observed nonlinearity has contributions from excited state absorption. The optical limiting response is also studied against particle size and the nonlinearity is found to increase with increasing particle size within the range of our investigations. On comparing the optical limiting properties, ZnFe{sub 2}O{sub 4} is found to be a better candidate for the optical limiting applications. To the best of our knowledge, this is the first report where the optical limiting properties of spinel ferrites are compared.

36 MATERIALS SCIENCE↗

A comparison of emissive probe techniques for electric potential measurements in a complex plasma

The major emissive probe techniques are compared to better understand the floating potential of an electron emitting surface in a plasma. An overview of the separation point technique, floating point technique, and inflection point in the limit of zero emission technique is given, addressing how each method works as well as the theoretical basis and limitations of each. It is shown that while the floating point method is the most popular, it is expected to yield a value {approx}1.5T{sub e}/e below the plasma potential due to a virtual cathode forming around the probe. The theoretical predictions were checked with experiments performed in a 2 kW annular Hall thruster plasma (n{sub e} {approx} 10{sup 9}-10{sup 10} cm{sup -3}and T{sub e} {approx} 10-50 eV). The authors find that the floating point method gives a value around 2T{sub e}/e below the inflection point method, which is shown to be a more accurate emissive probe technique than other techniques used in this work for measurements of the plasma potential.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for the Rare Decay $K_L \to \pi^0 \pi^0 \mu^+ \mu^-$

This thesis describes the search for K L → π 0 π 0 μ + μ - , which was conducted using data collected by the KTeV Experiment at Fermi National Accelerator Laboratory in Batavia, Illinois. Although this decay mode is possible within the Standard Model, it is limited to a very narrow band of phase space. The HyperCP Experiment has recently observed three Σ + → pμ + μ - events within a narrow dimuon mass range of 213.8 MeV/c 2 to 214.8 MeV/c 2 . This suggests that the process could occur via a neutral intermediary particle, Σ + → pX 0 → pμ + μ - , with an X 0 mass of 214.3 MeV/c 2 ± 0.5 MeV/c 2 . Since the X 0 has a light mass and a low interaction probability, then it is most likely a new neutral boson that exists beyond the Standard Model. Recent theoretical predictions suggest that the decay mode K L → π 0 π 0 μ + μ - can also occur via the aforementioned neutral boson: K L → π 0 π 0 X 0 → π 0 π 0 μ + μ - . Therefore, in addition to a Standard Model measurement, the search for K L → π 0 π 0 μ + μ - is also carried out in an effort to address the viability of X 0 in explaining the HyperCP phenomena. Measurement of the upper limits presented in this thesis were performed using blind analysis techniques. The upper limit of the decay K L → π 0 π 0 μ + μ - has been measured in this thesis to be BR(K L → π 0 π 0 μ + μ - ) < 8.63 x 10 -11 at 90% confidence level. In addition, this thesis has measured the upper limit of the decay K L → π 0 π 0 X 0 → π 0 π 0 μ + μ - to be Br(K L → π 0 π 0 X 0 → π 0 π 0 μ + μ - ) < 9.44 x 10 -11 at the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Two biased estimation techniques in linear regression: Application to aircraft

Several ways for detection and assessment of collinearity in measured data are discussed. Because data collinearity usually results in poor least squares estimates, two estimation techniques which can limit a damaging effect of collinearity are presented. These two techniques, the principal components regression and mixed estimation, belong to a class of biased estimation techniques. Detection and assessment of data collinearity and the two biased estimation techniques are demonstrated in two examples using flight test data from longitudinal maneuvers of an experimental aircraft. The eigensystem analysis and parameter variance decomposition appeared to be a promising tool for collinearity evaluation. The biased estimators had far better accuracy than the results from the ordinary least squares technique.

Klein, Vladislav↗

Utilization of Data Augmentation Techniques in Automated Inspection Systems for Defect Detection in Metals With Limited Data

Accurate identification of defects on metal surfaces is of great interest to many industry sectors, such as the automotive and aerospace industries. In contrast to conventional manual inspection techniques, recent automated inspection systems employ deep learning models trained to detect defects rapidly and precisely. The development of these models often requires a substantial image dataset to acquire adequate knowledge of defect features and enhance their predictive accuracy. When data is limited, augmentation techniques are often used to improve the precision and accuracy of defect detection systems. This study examined the prediction performance of two object detection models, namely Faster Region‐based Convolutional Neural Network (Faster R‐CNN) and You Only Look Once version 8 (YOLOv8), to identify dent defects in limited images of cast iron cylinder head surfaces. The original image set contains 46 images with 563 dents. To overcome limited data availability, common image augmentation techniques along with a copy‐paste method were applied. Results show that standard augmentation improved YOLOv8 accuracy by 8.00% and average precision (AP) by 3.00%. On the other hand, the copy‐paste technique achieved a 20.00% increase in accuracy and a 1% increase in AP with just 200 synthetic dents. Furthermore, these results provide support for using the copy‐paste augmentation strategy to enhance defect detection performance, with a limited dataset, contributing to more accurate defect identification in remanufacturing processes.

36 MATERIALS SCIENCE↗

Laboratory instrumentation and techniques for characterizing multi-junction solar cells for space applications

Multi-junction solar cells are attractive for space applications because they can be designed to convert a larger fraction of AMO into electrical power at a lower cost than single-junction cells. The performance of multi-junction cells is much more sensitive to the spectral irradiance of the illuminating source than single-junction cells. The design of high efficiency multi-junction cells for space applications requires matching the optoelectronic properties of the junctions to AMO spectral irradiance. Unlike single-junction cells, it is not possible to carry out quantum efficiency measurements using only a monochromatic probe beam and determining the cell short-circuit current assuming linearity of the quantum efficiency. Additionally, current-voltage characteristics can not be calculated from measurements under non-AMO light sources using spectral-correction methods. There are reports in the literature on characterizing the performance of multi junction cells by measuring and convoluting the quantum efficiency of each junction with the spectral irradiance; the technique is of limited value for the characterization of cell performance under AMO power-generating conditions. We report the results of research to develop instrumentation and techniques for characterizing multi junction solar cells for space . An integrated system is described which consists of a standard lamp, spectral radiometer, dual-source solar simulator, and personal computer based current-voltage and quantum efficiency equipment. The spectral radiometer is calibrated regularly using the tungsten-halogen standard lamp which has a calibration based on NIST scales. The solar simulator produces the light bias beam for current-voltage and cell quantum efficiency measurements. The calibrated spectral radiometer is used to 'fit' the spectral irradiance of the dual-source solar simulator to WRL AMO data. The quantum efficiency apparatus includes a monochromatic probe beam for measuring the absolute cell quantum efficiency at various voltage biases, including the voltage bias corresponding to the maximum-power point under AMO light bias. The details of the procedures to 'fit' the spectral irradiance to AMO will be discussed. An assessment of the role of the accuracy of the 'fit' of the spectral irradiance and probe beam intensity on measured cell characteristics will be presented. quantum efficiencies were measured with both spectral light bias and AMO light bias; the measurements show striking differences. Spectral irradiances were convoluted with cell quantum efficiencies to calculate cell currents as function of voltage. The calculated currents compare with measured currents at the 1% level. Measurements on a variety of multi-junction cells will be presented. The dependence of defects in junctions on cell quantum efficiencies measured under light and voltage bias conditions will be presented. Comments will be made on issues related to standards for calibration, and limitations of the instrumentation and techniques. Expeditious development of multi-junction solar cell technology for space presents challenges for cell characterization in the laboratory.

Woodyard, James R.↗

Neutron scattering in photosynthesis research: recent advances and perspectives for testing crop plants

The photosynthetic performance of crop plants under a variety of environmental factors and stress conditions, at the fundamental level, depends largely on the organization and structural flexibility of thylakoid membranes. These highly organized membranes accommodate virtually all protein complexes and additional compounds carrying out the light reactions of photosynthesis. Most regulatory mechanisms fine-tuning the photosynthetic functions affect the organization of thylakoid membranes at different levels of the structural complexity. In order to monitor these reorganizations, non-invasive techniques are of special value. On the mesoscopic scale, small-angle neutron scattering (SANS) has been shown to deliver statistically and spatially averaged information on the periodic organization of the thylakoid membranes in vivo and/or, in isolated thylakoids, under physiologically relevant conditions, without fixation or staining. More importantly, SANS investigations have revealed rapid reversible reorganizations on the timescale of several seconds and minutes. In this paper, we give a short introduction into the basics of SANS technique, advantages and limitations, and briefly overview recent advances and potential applications of this technique in the physiology and biotechnology of crop plants. We also discuss future perspectives of neutron crystallography and different neutron scattering techniques, which are anticipated to become more accessible and of more use in photosynthesis research at new facilities with higher fluxes and innovative instrumentation.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of Flaw Size From Thermographic Data

Simple methods for reducing the pulsed thermographic responses of delaminations tend to overestimate the size of the delamination, since the heat diffuses in the plane parallel to the surface. The result is a temperature profile over the delamination which is larger than the delamination size. A variational approach is presented for reducing the thermographic data to produce an estimated size for a flaw that is much closer to the true size of the delamination. The method is based on an estimate for the thermal response that is a convolution of a Gaussian kernel with the shape of the flaw. The size is determined from both the temporal and spatial thermal response of the exterior surface above the delamination and constraints on the length of the contour surrounding the delamination. Examples of the application of the technique to simulation and experimental data are presented to investigate the limitations of the technique.

Winfree, William P.↗