Search NASA⌕ Search

SEARCH · Search NASA

Results for “load changes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Purpose, Design, and Analysis of the NSTX-U Centerstack Casing Lateral Support Shims

The National Spherical Torus Experiment Upgrade (NSTX-U) centerstack casing surrounds the central magnet core of NSTXU. It provides the inner vacuum boundary of the plasma chamber and supports the radially inboard plasma facing components lining the plasma chamber. The casing is supported like a cantilever, fixed at the lower flange by a connection to the TF Bundle through a G-10 ring. It is flexibly supported at the top by bellows, and insulated shims intended to react the largest part of the inventory of the disruption loads at the upper support, thereby protecting the upper and lower connections from excessive loads. A large part of the qualification of the casing and tiles requires addressing and quantifying disruption loads. These have been estimated based on extensions of the behavior of NSTX during its run period roughly 15 years ago. Structural qualification of the Upgrade used these estimates of the loading as input to calculations to demonstrate adequacy for a “most probable” disruption. The estimates are included in a requirements document to guide conservative design of all components loaded by disruptions. However, the changes made for the upgrade made the extrapolation of disruption behavior uncertain. Disruptions include axisymmetric loading from axisymmetric currents induced in the vessel shells. In addition, more complex currents called Halo currents are a result of plasma poloidal currents impinging on the casing. The halo currents add another layer of uncertain behavior and net lateral loading to the casing. As a result, NSTX-U is equipped with a number of instruments intended to assess the nature and severity of disruptions. The casing shims are required for lateral support of the casing, but these have also been converted to load cells to provide another measure of the magnitude of symmetric and asymmetric loading. Some of the logic in the development of the requirements document are presented. Electromagnetic analysis of axisymmetric and halo loading is described. Global simulations of the casing transient dynamic response, and local analysis and testing of the shim/load cell are included. The shim load cells and other instrumentation will be an important guide in planning NSTX-U experiments beyond its next run period expected in late 2026 or early 2027.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cost Analysis of Simple Phase Change Material-Enhanced Building Envelopes in Southern U.S. Climates

Traditional thermal designs of building envelope assemblies are based on static energy flows, yet building envelopes are subject to varying environmental conditions. This mismatch between the steady-state principles and their dynamic operation can decrease thermal efficiency. Design work supporting the development of low-energy houses showed that conventional insulations may not always be the most cost effective solution to improvement envelope thermal performance. PCM-enhanced building envelopes that simultaneously reduce the total cooling loads and shift the peak-hour loads are the focus of this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Analysis of Simple Phase Change Material-Enhanced Building Envelopes in Southern U.S. Climates

Traditional thermal designs of building envelope assemblies are based on static energy flows, yet building envelopes are subject to varying environmental conditions. This mismatch between the steady-state principles and their dynamic operation can decrease thermal efficiency. Design work supporting the development of low-energy houses showed that conventional insulations may not always be the most cost effective solution to improvement envelope thermal performance. PCM-enhanced building envelopes that simultaneously reduce the total cooling loads and shift the peak-hour loads are the focus of this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANALYSIS OF DISTRIBUTION FEEDER LOSSES DUE TO ADDITION OF DISTRIBUTED PHOTOVOLTAIC GENERATORS

Distributed generators (DG) are small scale power supplying sources owned by customers or utilities and scattered throughout the power system distribution network. Distributed generation can be both renewable and non-renewable. Addition of distributed generation is primarily to increase feeder capacity and to provide peak load reduction. However, this addition comes with several impacts on the distribution feeder. Several studies have shown that addition of DG leads to reduction of feeder loss. However, most of these studies have considered lumped load and distributed load models to analyze the effects on system losses, where the dynamic variation of load due to seasonal changes is ignored. It is very important for utilities to minimize the losses under all scenarios to decrease revenue losses, promote efficient asset utilization, and therefore, increase feeder capacity. This paper will investigate an IEEE 13-node feeder populated with photovoltaic generators on detailed residential houses with water heater, Heating Ventilation and Air conditioning (HVAC) units, lights, and other plug and convenience loads. An analysis of losses for different power system components, such as transformers, underground and overhead lines, and triplex lines, will be performed. The analysis will utilize different seasons and different solar penetration levels (15%, 30%).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

A Robust Processing Approach for Producing Highly Loaded Dispersion Fuels

A robust fabrication method, resulting in higher yields, to produce highly loaded U3Si2-Al dispersion fuels for converting research reactors from a high enriched to a low enriched uranium fuel needs to be developed. To reliably produce a highly loaded dispersion fuel, process changes need to be implemented where the traditional approach has experienced challenges and poor yields. The present work describes the key changes needed. Parts of the work were done with uranium silicide and parts were completed with a representative silicide surrogate. The major deviations from traditional fabrication methods are associated with a refinement in particle size distribution, method for compacting to achieve complex shapes, and welding of the aluminum picture frame used to encapsulate the fuel compact. Methods for rolling and arc melting are also discussed. By using the methods described within, fabricating a highly loaded dispersion fuel that can meet stringent fuel homogeneity and geometry requirements at higher yields and lower costs may be possible.

U3Si2, HFIR, dispersion fuel, Uranium, Research Re↗

Societal decisions about climate mitigation will have dramatic impacts on eutrophication in the 21st century

Excessive nitrogen loading leads to degraded water quality that harms human and ecosystem health. Here, we examine the impact of changes in land use and land management for six combinations of socioeconomic pathways (SSPs) and climate outcomes and find that future societal choices will substantially impact riverine nitrogen loading (+54% to -7%) for the continental United States by the end-of-the-century. Regional impacts will be even larger. The increase in nitrogen loading is projected both for high emission pathways with increased food demand and for societal pathways that achieve high climate mitigation through increased biofuel production. Conversely, projected decreases in nitrogen loading are associated with future pathways with low food demand and no climate mitigation efforts. Thus, climate mitigation may have unintended consequences in the form of increased eutrophication, although some pathways suggests that limiting climate change and eutrophication need not be mutually exclusive. We find that changes in cropland, developed land, and fertilizer application rates are all important drivers in explaining the projected changes in nitrogen loading. Climate change–induced precipitation changes will further amplify the projected increase in nitrogen loading or offset the improvement in loading resulting in a net change of +1% to +68% by the end-of-the-century. Globally, vast portions of South, East, and Southeast Asia will also likely experience increased eutrophication by the end-of-the-century due to increased cropland area and agricultural intensification. These findings highlight the need to account for the impact of both societal and climate trends in designing strategies for managing inland and coastal water quality.

54 ENVIRONMENTAL SCIENCES↗

Considerations for Medium-Term Load Forecasting in Morocco

There are many factors that determine how demand for electricity may change over time. Medium-term load forecasting is a subset of load forecasting that focuses on the next year. This presentation summarizes analysis performed by NREL on medium-term load forecasting performed for the Moroccan energy system. This analysis includes hourly regressions and load clustering. This work also describes potential next steps that can be implemented by ONEE to improve this medium-term load forecasting.

54 ENVIRONMENTAL SCIENCES↗

3D pore analysis of gasoline particulate filters using X-ray tomography: impact of coating and ash loading

Since particulate emissions control technologies are dependent on filtration technologies, development of porous materials with optimized pore structures is crucial to improve filtration efficiency and pressure drop across filters. Despite increasing attention to 3D measurements of porous materials, there are few reports of pore structure investigations of diesel/gasoline particulate filters (D/GPFs) using 3D visualization techniques. Here, GPF 3D pore structures were examined using X-ray tomography (XRT) to identify the impacts of catalyst coating or ash loading. Voxel resolution of 2.93 mu m made it impossible to distinguish coating or ash materials from the cordierite substrate or to recognize smaller pores than the voxel resolution. However, pores up to 200 mu m, which are responsible for the most pore volume, were successfully analyzed. Coating and ash loading resulted in lowering average pore diameter, total porosity, and open porosity, as the peak density of pore diameter at 60 mu m decreased, while pores below 20 mu m increased. Also, the visualized closed pores, which were homogeneously distributed throughout the bare filter, tended to get larger from inlet to outlet sides and more likely to be on the surface inlet due to coating and ash loading, indicating gas pathways originally existing in open pores were blocked due to coating and ash loading, leading to increased pressure drop. The ash impact was found to be more noticeable on mid and back positions than on front position. In addition, the investigation of areal porosity along the direction of gas flow suggested that while ash penetration could reach the outlet side as noted from increased closed pore population, most ash particles would be contained up to 150 mu m. Lastly, the 2D crosscut microscopic analysis that requires destructive procedures with the limited examination area could provide underestimation of ash penetration, whereas the 3D XRT analysis seems to provide more accurate information of pore structure changes due to ash loading at different locations.

36 MATERIALS SCIENCE↗

Microstructural Evolution and ORR Activity of Nanocolumnar Platinum Thin Films with Different Mass Loadings Grown by High Pressure Sputtering

Nanocolumnar platinum thin films (Pt-TFs) with different Pt mass loadings were grown by high pressure sputtering (HIPS) and investigated as oxygen reduction reaction (ORR) electrocatalysts for polymer electrolyte membrane fuel cell applications. Mass loading was controlled by changing the sputter deposition time. A cauliflower-like columnar microstructure was achieved by depositing the Pt-TFs onto a microporous layer (MPL)-like surface composed of carbon particles in order to mimic catalyst-coated gas diffusion electrodes. Microstructural evolution of HIPS Pt-TFs and their ORR activity were investigated. Electrochemical characterization of the nanocolumnar Pt-TFs was performed by cyclic voltammetry and rotating disk electrode measurements on Pt-TF/MPL-like-layer/glassy-carbon samples in an aqueous perchloric acid electrolyte. The electrochemically active surface area increased from 18 to 39 m 2 g –1 as the Pt mass loading was decreased. Specific activity of the films was similar (~600 μA cm –2 ) for all Pt mass loadings, due to the similar nanoparticle sizes of ~5 nm as observed by transmission electron microscopy and X-ray diffraction. Furthermore, mass activity of the films increased from 0.11 to 0.26 A mg –1 as the Pt mass loading was decreased, which is an indication of the effective Pt utilization and better access through the catalyst layer at lower Pt mass loadings.

08 HYDROGEN↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Closure Device For a Containment Vessel in a Small Gram Quantity Shipping Package

SRNL has been chartered by DOE Environmental Management (DOE-EM) to develop a new Type B shipping package for Small Gram Quantities (SGQ) of radioactive material. Design a containment vessel (CV) closure device that will reduce the operation time and improve the ease-of- use for Operations Personnel. The Containment Vessel (CV) includes a closure lid cap with spring shaft and locking tabs, multiple disc springs, and vessel with integral locking ring. The CV is assembled by aligning the tabs on the lid cap with the openings in the locking ring. Next, the lid cap is pushed down to compress the disc springs. Finally, the lid is rotated 45-degrees to locking location. When released, the tabs are secured against the locking ring. Disc springs (e.g. Belleville washers, coned-disc springs, Belleville spring, etc.) exert axial loads on the mating parts when compressed. The orientation of the disc springs can be configured to change the deflection and axial loads for specific designs. In addition to securing the lid cap to the vessel, the compressed disc springs can be used to apply a load to a containment seal (e.g. o-ring). A prototype of the CV closure was 3D printed to evaluate the locking mechanism design and functionality. A test plan will be developed to evaluate the mechanical properties (i.e. compression forces) and functionality of the CV closure design.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvements to the Simplified Loads Methodology in IEC 61400-2: November 22, 2021 - November 21, 2022

The "Simplified Loads Model" (SLM) of IEC 61400-2 provides a simple methodology to assess the structural integrity of a small wind turbine (SWT). The SLM is unique to the small wind turbine standard. It was included to allow SWT manufacturers with limited resources to undertake integrity checks at a reasonable cost in time and resources and avoid the expense of detailed aeroelastic simulations. Unfortunately, the SLM has gained the reputation of being overly conservative and this has reduced its value to the SWT community and its use in SWT design and certification. Conservatism in design standards is needed but excessive conservatism is not. The aim of this report is to address the principal areas of excess conservatism and recommend changes to the SLM that preserve its simplicity but reduce the excess. The changes for the ultimate loads are consistent with their treatment in aeroelastic modelling for certification and with related codes for wind loading on structures. The recommendations for a new fatigue design load case are also based on aeroelastic simulations, in this case of five SWTs of varying configurations with rated power from 2.4 to 50 kW. It is also pointed out the design load case for yawed operation omits an important term. The recommended inclusion of this term would make the SLM slightly more conservative for this case.

17 WIND ENERGY↗

Potential Roles for Demand Response in High-Growth Electric Systems with Increasing Shares of Renewable Generation

Many countries around the world are experiencing rapid economic development while simultaneously deploying more wind and solar generators. This report explores potential roles for demand response - the modification of electricity load operations to provide grid services - to support these countries' development goals through enhancing grid reliability and assisting with renewable energy integration in the power sector. After reviewing current demand response programs types, which include wholesale and retail market offerings, as well as broader distributed energy resource (DER) aggregation programs, we reflect on the historical trajectory of demand response as a grid resource and on recent findings from renewable integration studies. The reviewed literature suggests that some types of demand response programs are likely to be more supportive of high-economic growth, high-renewable contexts than others. We conclude by outlining best practices for the design of new demand response programs that build on the historical lessons learned and are well suited to accommodate expected future changes in generation and load patterns.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Regenerative Fuel Cell System (Cooperative Research and Development Final Report, CRADA Number CRD-16-635)

Grid energy storage is required to maintain reliable electricity delivery from energy producers to their customers. As electrical loads on the grid change throughout the day, stored energy supplies electricity during increased power demand periods. Further, as more renewable and alternative energy sources are added, energy storage will maximize the usefulness of these technologies. Currently, the United States has over 24.6 GW of grid storage, about 2% of the total electrical production capacity. About 95% of energy storage comes from pumped hydro. However, pumped hydro energy storage is dependent on existing geographic features, making it difficult to integrate with widespread renewable energy sources. As energy demands continue to expand, and more renewable energy (i.e. wind and solar) is added to the grid, new energy storage technologies will be needed that are not dependent on geographic features. Battery technologies can provide energy storage for some applications, but are not economically well-suited for long duration charge/discharges, such as load-leveling of renewable energy. Consequently, development of new energy storage devices will augment the existing grid and reduce the capital investment in construction upgrades. As ever-increasing mandates for renewable energy are implemented, lower-cost energy storage solutions for renewable energy will be necessary to keep electricity costs low for consumers.

13 HYDRO ENERGY↗

Optical based tactile shear and normal load sensor

Various technologies described herein pertain to a tactile sensor that senses normal load and/or shear load. The tactile sensor includes a first layer and an optically transparent layer bonded together. At least a portion of the first layer is made of optically reflective material. The optically transparent layer is made of resilient material (e.g., clear silicone rubber). The tactile sensor includes light emitter/light detector pair(s), which respectively detect either normal load or shear load. Light emitter(s) emit light that traverses through the optically transparent layer and reflects off optically reflective material of the first layer, and light detector(s) detect and measure intensity of reflected light. When a normal load is applied, the optically transparent layer compresses, causing a change in reflected light intensity. When shear load is applied, a boundary between optically reflective material and optically absorptive material is laterally displaced, causing a change in reflected light intensity.

36 MATERIALS SCIENCE↗