Magnetron R&D toward the Amplitude Modulation Control for SRF Accelerator

The scheme of using a high efficiency magnetron to drive a superconducting radio frequency (SRF) accelerator cavity needs not only the injection phase locking but also the amplitude modulation to compensate the cavity's microphomics caused cavity voltage change and the beam loading variation. To be able to do a fast and efficient modulation, the magnetron's magnetic field has to be trimmed by an external coil to compensate the frequency pushing effect due to the anode current change [1]. A low eddy current magnetron body has been designed and built [2]. This paper will present the analytical prediction, simulation and experimental results on the 2.45 GHz magnetron test stand with the modulation frequency up to 1 kHz. In addition, the progresses on the injection lock to a copper cavity, new 1497 MHz magnetron prototype, 13 kW high power magnetron test stand development and newly built low level RF (LLRF) controller for the amplitude modulation will be reported.

Rimmer, Robert A.↗

Optimal Recursive Digital Filters for Active Bending Stabilization

In the design of flight control systems for large flexible boosters, it is common practice to utilize active feedback control of the first lateral structural bending mode so as to suppress transients and reduce gust loading. Typically, active stabilization or phase stabilization is achieved by carefully shaping the loop transfer function in the frequency domain via the use of compensating filters combined with the frequency response characteristics of the nozzle/actuator system. In this paper we present a new approach for parameterizing and determining optimal low-order recursive linear digital filters so as to satisfy phase shaping constraints for bending and sloshing dynamics while simultaneously maximizing attenuation in other frequency bands of interest, e.g. near higher frequency parasitic structural modes. By parameterizing the filter directly in the z-plane with certain restrictions, the search space of candidate filter designs that satisfy the constraints is restricted to stable, minimum phase recursive low-pass filters with well-conditioned coefficients. Combined with optimal output feedback blending from multiple rate gyros, the present approach enables rapid and robust parametrization of autopilot bending filters to attain flight control performance objectives. Numerical results are presented that illustrate the application of the present technique to the development of rate gyro filters for an exploration-class multi-engined space launch vehicle.

Orr, Jeb S.↗

Short-term exposure to elevated suspended sediment increases oxygen uptake of gilled larval Eastern Hellbender ( Cryptobranchus alleganiensis ) salamanders

Freshwater ecosystems are increasingly impacted by anthropogenic elevated levels of suspended sediment that may negatively affect aquatic organisms, including salamanders. Although increasing fine sediment in streams has been suggested as a reason for population declines, to date no study has empirically assessed the effect of suspended sediment on gilled larval Eastern Hellbenders (Cryptobranchus alleganiensis (Sonnini de Manoncourt and Latreille, 1801)), a critical life-history stage and a species of conservation concern. We used custom respirometers to elucidate effects of suspended sediments on larval Eastern Hellbender oxygen uptake in trials conducted in situ in Georgia (USA) streams. Mean oxygen uptake increased and was significantly higher in trials when larval salamanders were exposed to suspended sediment (mean = 5.06 mg O 2 /L for 800 mg/L of sediment treatment vs. 2.25 mg O 2 /L for 0.00 mg/L of sediment control). This may indicate elevated physiological stress in response to short-term exposure to suspended sediments. Qualitatively, individuals in both groups exhibited rocking behavior in response to low oxygen (hypoxia), albeit at different frequencies (sediment exposure = 7.6 rocks/min and control = 2.1 rocks/min). Larval salamanders may be able to temporarily compensate for low oxygen through increased rocking behavior when high suspended sediment loads are present, with future respirometry research needed.

hypoxia↗

AH-1G flight vibration correlation using NASTRAN and the C81 rotor/airframe coupled analysis

Analytical results are presented bearing on the accuracy of state-of-the-art NASTRAN FEM modeling techniques and rotor/airframe coupling methods for the prediction of flight vibrations; these results have been studied by NASA and industry experts in order to ensure scientific control of the analysis/correlation exercise. The rotor loads predicted by the dynamically coupled rotor/airframe analysis showed good agreement between calculated and experimental blade loads, as did the predominant excitation frequency vibration levels predicted by NASTRAN.

Dompka, R. V.↗

Pulsatile Fluid Shear in Bone Remodeling

The objective of this investigation was to elucidate the sensitivity to transients in fluid shear stress in bone remodeling. Bone remodeling is clearly a function of the local mechanical environment which includes interstitial fluid flow. Traditionally, load-induced remodeling has been associated with low frequency (1-2 Hz) signals attributed to normal locomotion. McLeod and Rubin, however, demonstrated in vivo remodeling events associated with high frequency (15-30 Hz) loading. Likewise, other in vivo studies demonstrated that slowly applied strains did not trigger remodeling events. We therefore hypothesized that the mechanosensitive pathways which control bone maintenance and remodeling are differentially sensitive to varying rates of applied fluid shear stress.

Frangos, John A.↗

Summary of Research Report

Ten papers, published in various publications, on buckling, and the effects of imperfections on various structures are presented. These papers are: (1) Buckling mode localization in elastic plates due to misplacement in the stiffner location; (2) On vibrational imperfection sensitivity on Augusti's model structure in the vicinity of a non-linear static state; (3) Imperfection sensitivity due to elastic moduli in the Roorda Koiter frame; (4) Buckling mode localization in a multi-span periodic structure with a disorder in a single span; (5) Prediction of natural frequency and buckling load variability due to uncertainty in material properties by convex modeling; (6) Derivation of multi-dimensional ellipsoidal convex model for experimental data; (7) Passive control of buckling deformation via Anderson localization phenomenon; (8)Effect of the thickness and initial im perfection on buckling on composite cylindrical shells: asymptotic analysis and numerical results by BOSOR4 and PANDA2; (9) Worst case estimation of homology design by convex analysis; (10) Buckling of structures with uncertain imperfections - Personal perspective.

Elishakoff, Isaac↗

Preliminary results on noncollocated torque control of space robot actuators

In the Space Station era, more operations will be performed robotically in space in the areas of servicing, assembly, and experiment tending among others. These robots may have various sets of requirements for accuracy, speed, and force generation, but there will be design constraints such as size, mass, and power dissipation limits. For actuation, a leading motor candidate is a dc brushless type, and there are numerous potential drive trains each with its own advantages and disadvantages. This experiment uses a harmonic drive and addresses some inherent limitations, namely its backdriveability and low frequency structural resonances. These effects are controlled and diminished by instrumenting the actuator system with a torque transducer on the output shaft. This noncollocated loop is closed to ensure that the commanded torque is accurately delivered to the manipulator link. The actuator system is modelled and its essential parameters identified. The nonlinear model for simulations will include inertias, gearing, stiction, flexibility, and the effects of output load variations. A linear model is extracted and used for designing the noncollocated torque and position feedback loops. These loops are simulated with the structural frequency encountered in the testbed system. Simulation results are given for various commands in position. The use of torque feedback is demonstrated to yield superior performance in settling time and positioning accuracy. An experimental setup being finished consists of a bench mounted motor and harmonic drive actuator system. A torque transducer and two position encoders, each with sufficient resolution and bandwidth, will provide sensory information. Parameters of the physical system are being identified and matched to analytical predictions. Initial feedback control laws will be incorporated in the bench test equipment and various experiments run to validate the designs. The status of these experiments is given.

Tilley, Scott W.↗

RivGen Controller Performance Raw Data, Igiugig, AK

Contains raw data for operations of Ocean Renewable Power Company (ORPC) RivGen Power System in Igiugig 2015 in Matlab data file format. Two data files capture the data and timestamps for data, including power in, voltage, rotation rate, and velocity. Location, Description, Format, Column 1, Date and time, MM/DD/YYYY, hh:mm:ss, Column 2, DC voltage (after DC filter), VDC, Column 3, DC current into inverters, IDC, Column 4, DC current into secondary resistive load, IDC, Column 5, Power into inverters, kW, Column 6, Power into secondary load, kW, Column 7, Frequency of single phase AC voltage from generator, Hz, Column 8, rotation rate of generator/turbine (rested at 1.1 when stationary), rad/s, Column 9, Velocity Algorithm 2, m/s, Column 10, Velocity Algorithm 3, m/s, Column 11, Rcodes for secondary load, see document "SL Controller PLC Memory", Column 12, Voltage measured between phase A and B, Vll,

16 TIDAL AND WAVE POWER↗

Adaptive Reinforcement Learning (ARL) Control of a Multi-port Resonant Converter in UAV Systems

This study presents an adaptive reinforcement learning (ARL) control framework for a multi-port resonant converter used in hybrid unmanned aerial vehicle (UAV) power systems. The converter integrates high-frequency half-bridge input ports connected to a rectified engine–generator set and a battery energy storage system, along with a semi-bridgeless active rectifier supplying the propulsion load. A deep RL agent is trained to dynamically regulate inter-port phase-shift commands in real time based on flight conditions and load power demand. The ARL controller autonomously identifies phase-shift combinations that maximize conversion efficiency while maintaining stable and coordinated power flow, even under rapidly varying operating scenarios. This data-driven approach eliminates the need for explicit system modeling or extensive manual tuning and enables coordinated control among multiple power ports without inter-port communication. Experimental results validate that the ARL based strategy achieves reliable power sharing and consistently high-efficiency operation across diverse UAV operating conditions.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Structural dynamic and control considerations for Space Station transportation node concepts

This paper discusses the results of two studies which investigated the expected low frequency dynamic characteristics of conceptual Mars and lunar transportation nodes. Both concepts are based on evolution of the assembly-complete Space Station Freedom configuration by the addition of keels, booms, and modules. Finite-element models of the concepts were developed and a set of undamped modes and frequencies was computed below 2 Hz for each concept. The modes were used as basis vectors for modal analyses describing the dynamic response of the structures to typical reboost maneuvers. The reboost maneuvers had fairly complex loading characteristics since the reaction control system (RCS) jets used for the maneuvers were off-modulated to control pitch and yaw attitude. Interaction of the dynamic response of the structure with the closed-loop attitude control system is investigated for both concepts. The elastic response in the solar dynamic region is investigated to evaluate the severity of the dynamic environment, since the solar dynamic systems have stringent sunpointing requirements which must be maintained during the reboost maneuver.

Cooper, Paul A.↗

Flashlamp drive system for a high-energy 10–100 kHz pulse-burst Nd:YAG laser

We present the design of the flashlamp drive system for the NG100 laser, a 1 J/pulse, 10–100 kHz, pulse-burst Nd:YAG laser system being developed for application in a Thomson scattering plasma diagnostic. This flashlamp drive system is under active development, with a prototype now being constructed. The flashlamp drive system is modular, with each module capable of driving a series pair of linear flashlamps. Each drive module contains and is controlled by a dedicated Analog Regulator Controller. Thus each module is independently operable and controllable. This modular approach imposes no intrinsic limit to the number of modules that may be applied to drive the flashlamp pairs in a laser system. Each flashlamp drive module has a switch-regulated topology. An 1800 V main capacitor bank provides 25 kJ of energy storage, while a lower voltage output capacitor bank provides filtering and the initial energy delivered to the flashlamps at the start of the drive pulse. The main bank is recharged after each flashlamp drive pulse. As energy is drawn from the output bank by the flashlamps, an IGBT switching regulator feeds current from the main bank through an inductor to replenish the output capacitor bank. The rate of replenishment is feedback-controlled to maintain a regulated supply of power to the flashlamp load, with a setpoint range of 0.07 to 1.65 MW. An Analog Regulator Controller produces two-state variable pulse width feedback switching of the regulator IGBT. The switching frequency is ≤ 20 kHz, dynamically adjusted to limit ripple of the flashlamp power to ±3% statistical standard deviation of mean. For development or troubleshooting, each module is operable independent of the laser digital control system (microcontroller and FPGA).

Plasma diagnostics - interferometry↗

A Novel AC to AC Wireless Power Transfer System for EV Charging Applications

In this paper, a novel ac to ac wireless power transfer (WPT) system is introduced for electric vehicle (EV) charging applications to reduce cost and design complexity. The presented wireless power transfer concept achieves unity power factor (UPF) on the grid-side by using a hybrid frequency ac / ac converter without an additional converter stage and closed loop control compared to the conventional systems. Due to inherent merit of the proposed ac / ac converter, ac input with 60 Hz grid frequency can be directly transferred to the load by superimposing with high frequency switching signal through the wireless coils. To validate the theoretical analysis of the proposed WPT system, the experimental results of the proposed converter are provided for 650 W output power by using 6 inches air gap between the couplers with the input of 110 VRMS ac source. The system overall efficiency is measured 89 % achieving 0.99 power factor (PF) and 1.5 % current total harmonic distortion (THD).

Asa, Erdem↗

A Comfort Model Simplification for Tight Integration with Grid Service Optimizations

Localized generation, storage, and intelligent power electronics are increasingly being integrated into building. The excess storage, thermal, and generation capacity can be used to develop new markets for ancillary services such as peak reduction, voltage and frequency support, or load flattening. Widespread participation in these markets will make the power grid more resilient. However, widespread participation in these markets will require a simple and intuitive control over the excess capacity by the building occupants. Most importantly for adopting these technologies, participation in these markets should not require sacrificing occupant comfort. Many of the proposed control and optimization technologies for supplying the ancillary services do not explicitly incorporate occupant comfort into their models and when they do, generally utilize a rigid constraint on the indoor air temperature set a priori. This reduces flexibility in using excess thermal capacity. It also cannot take into account uncertainties in local factors that affect thermal comfort such as clothing insulation or relative humidity. In this paper we present and justify some assumptions that simplify the standard predictors of thermal comfort. We also develop a regression model of the thermal comfort that is linear with respect to the indoor air temperature. Next we develop the concept of thermal comfort variation that eliminates the dependence of the thermal comfort on uncertain thermal comfort factors. Then, we present a quadratic program utilizing the thermal comfort variation in both the objective function and as a constraint. Finally, we show the results of a time-of-use cost optimization that utilizes the simplified thermal comfort model.

Melin, Alexander↗

Effects of higher harmonic control on rotor performance and control loads

An analytical study, based on an advanced Higher Harmonic Control (HHC) analysis for helicopter rotor systems, is carried out to investigate HHC application for rotor performance enhancement. The effects of HHC on stall characteristics of rotor and blade pitch-link loads when the system is configured to suppress vibration are also examined. For vibration control, simulated results indicate that HHC may promote early blade stall. Effects of blade torsion frequencies on HHC performance are moderate, and torsionally stiff blades require less actuator power than torsionally soft blades. For rotor performance improvement, a 3 to 5 percent reduction in rotor shaft power can be achieved with 2 deg of two-per-rev blade pitch control.

Nguyen, Khanh↗

The Rocketdyne Multifunction Tester. Part 2: Operation of a Radial Magnetic Bearing as an Excitation Source

The operation of the magnetic bearing used as an excitation source in the Rocketdyne Multifunction Tester is described. The tester is scheduled for operation during the summer of 1990. The magnetic bearing can be used in two control modes: (1) open loop mode, in which the magnetic bearing operates as a force actuator; and (2) closed loop mode, in which the magnetic bearing provides shaft support. Either control mode can be used to excite the shaft; however, response of the shaft in the two control modes is different due to the alteration of the eigenvalues by closed loop mode operation. A rotordynamic model is developed to predict the frequency response of the tester due to excitation in either control mode. Closed loop mode excitation is shown to be similar to the excitation produced by a rotating eccentricity in a conventional bearing. Predicted frequency response of the tester in the two control modes is compared, and the maximum response is shown to be the same for the two control modes when synchronous unbalance loading is not considered. The analysis shows that the response of this tester is adequate for the extraction of rotordynamic stiffness, damping, and inertia coefficients over a wide range of test article stiffnesses.

Hawkins, L. A.↗

Multiport Control with Partial Power Processing in Solid-State Transformer for PV, Storage, and Fast-Charging Electric Vehicle Integration

This article proposes a multiport control method to enable partial power processing (PPP) in a medium-voltage (MV) multiport solid-state transformer (SST). MV multiport SSTs are promising in integrating low-voltage DC sources or loads such as solar photovoltaic, energy storage, and electric vehicles into smart grids without bulky line-frequency transformers. Compared to voltage-source SST, current-source (CS) SST features single-stage isolated bidirectional AC/AC, AC/DC, or DC/DC conversion using an inductive DC link. For a multiport CS SST, it is revealed in this article that the PPP capability can be enabled through the proposed control without extra hardware, different from the case of voltage-source converters where special hardware architecture is required for the PPP. With the PPP, most power exchange between LV ports is processed by only a fraction of the entire conversion stage, leading to reduced DC-link current, volume, loss, and improved efficiency. The proposed multiport PPP control scheme is analyzed to verify the advantages across a wide voltage and power range against conventional full power processing (FPP) multiport control, using the soft-switching solid-state transformer (S4T) with reduced conduction loss as an example. Comparative experimental results based on a SiC three-port S4T prototype verify the effectiveness of the proposed PPP scheme against the FPP scheme under both steady state and dynamic conditions. Here, the DC-link current reduction is measured to be more than 36%. Significantly, the proposed multiport PPP control scheme is generic and applicable to any hard-switching or soft-switching CS SSTs without extra hardware.

14 SOLAR ENERGY↗

State-Constrained Grid-Forming Inverter Control for Robust Operation of AC Microgrids

The control of grid-forming inverters has become an important problem to achieve high efficiency, reliability, and resilience of the future power grid. The distributed control that utilizes a sparse communication network has been proposed for AC microgrids, in which each DG only has access to the information of a small number of its neighboring DGs, reducing the computational complexity and improving the resiliency to faults and unknown parameters. However, these approaches have not provided a clear analysis of the coupling between active/reactive power injections and the voltage magnitude/frequency or a distributed updating law with a solid theoretical foundation. Additionally, in the existing approaches, tracking the references from the secondary control may violate operational constraints.

Xu, Ying↗