Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Implications of first neutrino-induced nuclear recoil measurements in direct detection experiments: Probing nonstandard interaction via CE ν NS

PandaX-4T and XENONnT have recently reported the first measurement of nuclear recoils induced by the B 8 solar neutrino flux, through the coherent elastic neutrino-nucleus scattering ( CE ν NS ) channel. As long anticipated, this is an important milestone for dark matter searches as well as for neutrino physics. This measurement means that these detectors have reached exposures such that searches for low mass, ≲ 10 GeV dark matter cannot be analyzed using the background-free paradigm going forward. It also opens a new era for these detectors to be used as neutrino observatories. In this paper we assess the sensitivity of these new measurements to new physics in the neutrino sector. We focus on neutrino nonstandard interactions (NSI) and show that—despite the still moderately low statistical significance of the signals—these data already provide valuable information. We find that limits on NSI from PandaX-4T and XENONnT measurements are comparable to those derived using combined COHERENT CsI and LAr data. Furthermore, they provide sensitivity to pure τ flavor parameters that are not accessible using stopped-pion or reactor sources. With larger exposures and consequently improvements of statistical uncertainties, forthcoming data from these experiments will provide important, novel results for CE ν NS -related physics. Published by the American Physical Society 2025

Sierra, D. Aristizabal↗

Muon capture on Li 6 , C 12 , and O 16 from ab initio nuclear theory

Muon capture on nuclei is one of the most promising probes of the nuclear electroweak current driving the yet-hypothetical neutrinoless double-beta (0νββ) decay. Both processes involve vector and axial-vector currents at finite momentum transfer, q ~ 100 MeV, as well as the induced pseu doscalar and weak-magnetism currents. Comparing measured muon-capture rates with reliable ab initio nuclear-theory predictions could help us validate these currents. To this end, we compute partial muon-capture rates for 6 Li, 12 C and 16 O, feeding the ground and excited states in 6 He, 12 B and 16 N, using ab initio no-core shell model with two- and three-nucleon chiral interactions. Here, we remove the spurious center-of-mass motion by introducing translationally invariant operators and approximate the effect of hadronic two-body currents by Fermi-gas model. We solve the bound-muon wave function from the Dirac wave equations in the Coulomb field created by a finite nucleus. We find that the computed rates to the low-lying states in the final nuclei are in good agreement with the measured counterparts. We highlight sensitivity of some of the transitions to the sub-leading three-nucleon interaction terms. We also compare summed rates to several tens of final states with the measured total capture rates and note that we slightly underestimate the total rate with this simple approach due to limited range of excitation energies

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Active layer depth and soil properties impact specific leaf area variation and ecosystem productivity in a boreal forest

Specific leaf area (SLA, leaf area per unit dry mass) is a key canopy structural characteristic, a measure of photosynthetic capacity, and an important input into many terrestrial process models. Although many studies have examined SLA variation, relatively few data exist from high latitude, climate-sensitive permafrost regions. We measured SLA and soil and topographic properties across a boreal forest permafrost transition, in which dominant tree species changed as permafrost deepened from 54 to >150 cm over 75 m hillslope transects in Caribou-Poker Creeks Research Watershed, Alaska. We characterized both linear and threshold relationships between topographic and edaphic variables and SLA and developed a conceptual model of these relationships. We found that the depth of the soil active layer above permafrost was significantly and positively correlated with SLA for both coniferous and deciduous boreal tree species. Intraspecific SLA variation was associated with a fivefold increase in net primary production, suggesting that changes in active layer depth due to permafrost thaw could strongly influence ecosystem productivity. While this is an exploratory study to begin understanding SLA variation in a non-contiguous permafrost system, our results indicate the need for more extensive evaluation across larger spatial domains. These empirical relationships and associated uncertainty can be incorporated into ecosystem models that use dynamic traits, improving our ability to predict ecosystem-level carbon cycling responses to ongoing climate change.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of the Higgs boson production rate in association with top quarks in final states with electrons, muons, and hadronically decaying tau leptons at $\sqrt{s} =$ 13 TeV

The rate for Higgs (${\mathrm{H}} $) bosons production in association with either one (${\mathrm{t}} {\mathrm{H}} $) or two (${\mathrm{t}} {{\overline{{{\mathrm{t}}}}}} {\mathrm{H}} $) top quarks is measured in final states containing multiple electrons, muons, or tau leptons decaying to hadrons and a neutrino, using proton–proton collisions recorded at a center-of-mass energy of $13\,\text {Te}\text {V} $ by the CMS experiment. The analyzed data correspond to an integrated luminosity of 137$\,\text {fb}^{-1}$. The analysis is aimed at events that contain ${\mathrm{H}} \rightarrow {\mathrm{W}} {\mathrm{W}} $, ${\mathrm{H}} \rightarrow {\tau } {\tau } $, or ${\mathrm{H}} \rightarrow {\mathrm{Z}} {\mathrm{Z}} $ decays and each of the top quark(s) decays either to lepton+jets or all-jet channels. Sensitivity to signal is maximized by including ten signatures in the analysis, depending on the lepton multiplicity. The separation among ${\mathrm{t}} {\mathrm{H}} $, ${\mathrm{t}} {{\overline{{{\mathrm{t}}}}}} {\mathrm{H}} $, and the backgrounds is enhanced through machine-learning techniques and matrix-element methods. The measured production rates for the ${\mathrm{t}} {{\overline{{{\mathrm{t}}}}}} {\mathrm{H}} $ and ${\mathrm{t}} {\mathrm{H}} $ signals correspond to $0.92 \pm 0.19\,\text {(stat)} ^{+0.17}_{-0.13}\,\text {(syst)} $ and $5.7 \pm 2.7\,\text {(stat)} \pm 3.0\,\text {(syst)} $ of their respective standard model (SM) expectations. The corresponding observed (expected) significance amounts to 4.7 (5.2) standard deviations for ${\mathrm{t}} {{\overline{{{\mathrm{t}}}}}} {\mathrm{H}} $, and to 1.4 (0.3) for ${\mathrm{t}} {\mathrm{H}} $ production. Assuming that the Higgs boson coupling to the tau lepton is equal in strength to its expectation in the SM, the coupling $y_{{\mathrm{t}}}$ of the Higgs boson to the top quark divided by its SM expectation, $\kappa _{{\mathrm{t}}}=y_{{\mathrm{t}}}/y_{{\mathrm{t}}}^{\mathrm {SM}}$, is constrained to be within $-0.9< \kappa _{{\mathrm{t}}}< -0.7$ or $0.7< \kappa _{{\mathrm{t}}}< 1.1$, at 95% confidence level. This result is the most sensitive measurement of the ${\mathrm{t}} {{\overline{{{\mathrm{t}}}}}} {\mathrm{H}} $ production rate to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of sensitivity analysis in DYMOND/Dakota to fuel cycle transition scenarios

The ability to perform sensitivity analysis has been enabled for the nuclear fuel cycle simulator DYMOND through its coupling with the design and analysis toolkit Dakota. To test and demonstrate these new capabilities, a transition scenario and multi-parameter study were devised. The transition scenario represents a partial transition from the US nuclear fleet to a closed fuel cycle with small modular LWRs and fast reactors fueled by reprocessed used nuclear fuel. Four uncertain parameters in this transition were studied – start date of reprocessing, total reprocessing capacity, the nuclear energy demand growth, and the rate at which the fast reactors are deployed – with respect to their impact on four response metrics. The responses – total natural uranium consumed, maximum annual enrichment capacity required, total disposed mass, and total cost of the nuclear fuel cycle – were chosen based on measures known to be of interest in transition scenarios and to be significantly impacted by the varying parameters. Furthermore, analysis of this study was performed both from the direct sampling and through surrogate models developed in Dakota to calculate the global sensitivity measures Sobol’ indices. This example application of this new capability showed that the most consequential parameter to most metrics was the share of new build capacity that is fast reactors. However, for the cost metric, the scaling factor of the energy demand growth was significant and had synergistic behavior with the fast reactor new build share.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigating Fission Reaction Rate Ratio Sensitivities [Abstract]

Reaction rate ratios are a measurable parameter for reactor and criticality applications. A number of foil irradiations and fission chamber measurements have been performed for critical assemblies at Los Alamos National Laboratory starting in the 1950’s including (i) Godiva, a bare HEU spherical assembly; (ii) Flattop-25, a spherical assembly consisting of an HEU core and a natural uranium reflector; (iii) Jezebel, a bare 239 Pu assembly; and (iv) Flattop-Pu, a spherical assembly consisting of a 239Pu core and a natural uranium reflector. Fission ratio data for 238 U(n,f)/ 235 U(n,f), 237 Np(n,f)/ 235 U(n,f), 233 U(n,f)/ 235 U(n,f) and 239 Pu(n,f)/ 235 U(n,f) were obtained and reported. The EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) project at Los Alamos National Laboratory (LANL) aims to constrain nuclear data by using a suite of measurement types beyond k-effective. Recent investigations include the use of pulsed spheres for nuclear data validation and other measurement methods of interest. One focus of the work is to determine if other methods are complimentary to the critical experiments utilized for nuclear data validation. It is anticipated the investigations will help inform methods that may be utilized in machine learning algorithms for nuclear validation. In order to use a measurement type for nuclear validation, it is necessary to obtain cross-section sensitivities for parameters. This work looks at reaction rate ratio sensitivities with SENSMG and Monte Carlo N-Particle R Code Version 6.21.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On negative induced polarization in frequency domain measurements

SUMMARY Induced polarization (IP) has been widely used to non-invasively characterize electrical conduction and polarization in the subsurface resulting from an applied electric field. Earth materials exhibit a lossy capacitance defined by a negative intrinsic phase in frequency-domain IP (FDIP) or a positive intrinsic chargeability in time-domain IP (TDIP). However, error-free positive apparent phase or negative apparent chargeability (i.e. negative IP effects) can occur in IP measurements over heterogeneous media. While negative IP effects in TDIP data sets have been discussed, no studies have addressed this topic in detail for FDIP measurements. We describe theory and numerical modelling to explain the origin of negative IP effects in FDIP measurements. A positive apparent phase may occur when a relatively high polarizability feature falls into negative sensitivity zones of complex resistivity measurements. The polarity of the apparent phase is determined by the distribution of subsurface intrinsic phase and resistivity, with the resistivity impacting the apparent phase polarity via its control on the sensitivity distribution. A physical explanation for the occurrence of positive apparent phase data is provided by an electric circuit model representing a four-electrode measurement. We also show that the apparent phase polarity will be frequency dependent when resistivity changes significantly with frequency (i.e. in the presence of significant IP effects). Consequently, negative IP effects manifest themselves in the shape of apparent phase spectra recorded with multifrequency (spectral IP) data sets. Our results imply that positive apparent phase measurements should be anticipated and should be retained during inversion and interpretation of single frequency and spectral IP data sets.

Geochemistry & Geophysics↗

Validation of MARS-F modeling of plasma response to RMPs using internal measurements on DIII-D

The linear resistive plasma response model is validated against the plasma internal measurement data from DIII-D edge-localized mode (ELM) control experiments with applied resonant magnetic perturbation (RMP). Considered are DIII-D discharges where the n = 1, 2, and 3 (n is the toroidal mode number) RMP field was applied. Experimental data for the plasma boundary displacement, as well as the three-dimensional (3D) pressure perturbation in the edge pedestal region, are deduced from the vertical Thomson scattering (TS) system and the horizontal charge exchange recombination (CER) system on DIII-D. The linear response model produces results that are in reasonable quantitative agreement with the DIII-D internal measurements. The plasma boundary displacement of up to 15 mm is modeled, with the pedestal pressure perturbation reaching 3 kPa. As an important insight, the larger plasma displacement measured by the vertical TS system, as compared to that measured by the horizontal CER system, is due to the contribution from the tangential component of the plasma displacement to the former. This mixing of displacement components is also found to influence the sensitivity of the CER measurement comparisons. The results of this study provide further confidence in the linear resistive plasma response model for analyzing ELM control experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

β -Nuclear-Recoil Correlation from $^6$$\mathrm{He}$ Decay in a Laser Trap

Here, we report the first precise measurement of a β-recoil correlation from a radioactive noble gas ( 6 He) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield |C T /C A | 2 ≤ 0.022 (90% confidence limit, C.L.). On the other hand, for left-handed neutrinos the limits are 0.007 < C T /C A < 0.111 (90% C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the microchannel plate used for recoil ion detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Undercooling minimization in ultrasound coupled DTA measurements of molten salts

Molten salts are ionic liquids that are used for the electrolytic pyroprocessing of metals and as heat transfer fluids in very high temperature processes. Recently, halide-based molten salt reactors (MSR) have gained momentum for high density and environmentally responsible electricity generation. The function of these reactors and their fuel cycle depend on a knowledge of the halide salt’s thermodynamic properties [1]. Therefore, high accuracy phase equilibria of MSR relevant base halide and actinide containing salts are needed. Modern thermal analysis of the phase transitions of halide salts is usually done during heating at relatively high scan rates with commercial devices. Normally such measurements are adequate for pure or pseudo-binary salts. However, as the number of components in the mixture increases, accurately resolving the liquidus becomes increasingly difficult. Reversing the scanning mode greatly increases the sensitivity of phase transition measurements but can decrease accuracy due to undercooling [2] — a common occurrence in molten halide systems [3]. This work presents the development of a differential thermal analysis (DTA) cell intended for use in radiological gloveboxes. Non-contact ultrasonic agitation of the halide salt is implemented to limit kinetic limitations on crystallization during cooling to minimize undercooling [4]. Measurements on halide salts are also presented to elucidate the effect of non-contact mixing on undercooling. Reference [1] S. Boyd and C. Taylor, “3 - Chemical fundamentals and applications of molten salts,” in Molten Salt Reactors and Thorium Energy, T. J. Dolan, Ed., Woodhead Publishing, 2017, pp. 29–91. doi: 10.1016/B978-0-08-101126-3.00003-8. [2] K. Nitsch, A. Cihlár, and M. Rodová, “Molten state and supercooling of lead halides,” J. Cryst. Growth, vol. 264, no. 1, pp. 492–498, Mar. 2004, doi: 10.1016/j.jcrysgro.2004.01.011. [3] L. Rycerz, “Practical remarks concerning phase diagrams determination on the basis of differential scanning calorimetry measurements,” J. Therm. Anal. Calorim., vol. 113, no. 1, pp. 231–238, Jul. 2013, doi: 10.1007/s10973-013-3097-0. [4] Md. H. Zahir, S. A. Mohamed, R. Saidur, and F. A. Al-Sulaiman, “Supercooling of phase-change materials and the techniques used to mitigate the phenomenon,” Appl. Energy, vol. 240, pp. 793–817, Apr. 2019, doi: 10.1016/j.apenergy.2019.02.045.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Collimated phase measuring deflectometry

Phase measuring deflectometry has been applied for free-form specular surface metrology, but its measured slope results are sensitive to the depth of sample positioning, which is also called the height-slope ambiguity. The objective of this work is to tackle this height-slope ambiguity problem. The main idea is to introduce collimated camera rays using a telecentric imaging lens and collimated structured-light illumination with a Fourier lens. This setup makes the fringe phases become only sensitive to the surface slopes and insensitive to the depth of the sample positioning. In this way, the slope calculation is theoretically independent of the sample depth. We call this new deflectometry technique Collimated Phase Measuring Deflectometry (CPMD). With our developed CPMD experimental setup, the measurement is insensitive to the depth of sample positioning, e.g., the measured height dispersion is less than 30 nm RMS within a 10 mm depth range when measuring a 50-mm-diameter spherical mirror with a 200 mm radius of curvature. In conclusion, the merits and limitations of the proposed CPMD technique are discussed, revealing its prospects in practical metrology applications and potential future investigations.

36 MATERIALS SCIENCE↗

ECCE sensitivity studies for single hadron transverse single spin asymmetry measurements

Here, we performed feasibility studies for various single transverse spin measurements that are related to the Sivers effect, transversity and the tensor charge, and the Collins fragmentation function. The processes studied include semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The data were obtained in pythia6 and geant4 simulated e+p collisions at 18 GeV on 275 GeV, 18 on 100, 10 on 100, and 5 on 41 that use the ECCE detector configuration. Typical DIS kinematics were selected, most notably Q 2 >1 GeV 2 , and cover the x range from 10 -4 to 1. The single spin asymmetries were extracted as a function of x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton, and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. They are obtained in azimuthal moments in combinations of the azimuthal angles of the hadron transverse momentum and transverse spin of the nucleon relative to the lepton scattering plane. In order to extract asymmetries, the initially unpolarized MonteCarlo was re-weighted in the true kinematic variables, hadron types and parton flavors based on global fits of fixed target SIDIS experiments and e + e – annihilation data. The expected statistical precision of such measurements is extrapolated to 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. Similar neutron information is obtained by comparing the ECCE e+p pseudo-data with the same from the EIC Yellow Report and scaling the corresponding Yellow Report e+ 3 He pseudo-data uncertainties accordingly. The impact on the knowledge of the Sivers functions, transversity and tensor charges, and the Collins function has then been evaluated in the same phenomenological extractions as in the Yellow Report. Finally, the impact is found to be comparable to that obtained with the parametrized Yellow Report detector and shows that the ECCE detector configuration can fulfill the physics goals on these quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imprecise global sensitivity analysis using bayesian multimodel inference and importance sampling

Global Sensitivity Analysis (GSA) aims to understand the relative importance of uncertain input variables to model response. Conventional GSA involves calculating sensitivity (Sobol’) indices for a model with known model parameter distributions. However, model parameters are affected by aleatory and epistemic uncertainty, with the latter often caused by lack of data. In this paper, we propose a new framework to quantify uncertainty in probability model-form and model parameters resulting from small datasets and integrate these uncertainties into Sobol’ index estimates. First, the process establishes, through Bayesian multimodel inference, a set of candidate probability models and their associated probabilities. Imprecise Sobol’ indices are calculated from these probability models using an importance sampling reweighting approach. This results in probabilistic Sobol’ indices, whose distribution characterizes uncertainty in the sensitivity resulting from small dataset size. The imprecise Sobol’ indices thus provide a measure of confidence in the sensitivity estimate and, moreover, can be used to inform data collection efforts targeted to minimize the impact of uncertainties. Through an example studying the parameters of a Timoshenko beam, we show that these probabilistic Sobol’ indices converge to the true/deterministic Sobol’ indices as the dataset size increases and hence, distribution-form uncertainty reduces. The approach is then applied to assess the sensitivity of the out-of-plane properties of an E-glass fiber composite material to its constituent properties. This second example illustrates the approach for an important class of materials with wide-ranging applications when data may be lacking for some input parameters.

42 ENGINEERING↗

Uncertainty about the Uncertainty [Slides]

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable result in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates, in comparison to the measurement uncertainty. Range of true values depends on the physics of the experiment, while measurement uncertainty depends on the measurement method (properties of the detector not of the experiment). When data from one–of–a kind experiment are analyzed, only the measurement uncertainty is reported. It gives no information about the range, in which the true values of experiment would spread if the experiment was repeated. A frequently used approximation, that if a physical quantity is measured as a function of time, only measurement of this quantity, produces uncertainty is also in some real experiments fare to strong. Example: In reaction history time measurement uncertainty propagated to alpha dominated under certain conditions over the flux measurement uncertainty propagated to alpha. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation Matrix Calibration of PMU Data-driven State Estimation Using Neural Network

Linear state estimation (LSE) is a phasor measurement unit (PMU) data-based power system state estimation that incorporates a linear measurement model in rectangular coordinates. Due to the high computational efficiency and high observational time-resolution, LSE can act as a supplementary state estimation in a wide-area monitoring system (WAMS). The performance of LSE is relatively sensitive to noises in measurements. Therefore, the estimation accuracy relies heavily on the accuracy of the estimation matrix, which is directly influenced by the measurement weight matrix. This paper proposes two novel calibration method of the estimation matrix using neural networks. One is based on the minimum absolute network loss (ANL), and the other is based on the minimum average squared network loss (ASNL). Both methods are tested and compared with LSE algorithms on the IEEE 14-bus system

neural network↗

Disordered hydrogen adsorption at the three-fold site of W(110)

Hydrogen often forms disordered phases on metals; however, deciphering the atomic-scale behavior requires experimental and modeling techniques that directly probe the short-range order between neighboring hydrogen adsorbates. Here, to address this challenge, we applied direct recoil spectroscopy (DRS) to investigate hydrogen adsorption on the W(110) surface. We show that the recoiled hydrogen flux measured during DRS is sensitive to the short range order of the adsorbed hydrogen. Ordered hydrogen neighbors are much more efficient at dechanneling incident ions along low-index surface channels, strongly suppressing the recoiled hydrogen flux along these directions. By modeling the DRS measurements with molecular dynamics for ordered and disordered hydrogen phases, we find that at a hydrogen surface coverage of approximately Θ = 0.6, the hydrogen adsorbates are bound to three-fold sites in a disordered phase at room temperature. This finding is consistent with transfer-matrix scaling model calculations that suggest the transition to an ordered hydrogen phase occurs at a greater surface coverage of Θ = 0.83.

08 HYDROGEN↗