Search NASA⌕ Search

SEARCH · Search NASA

Results for “media”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Derivation of A Representative Elementary Volume (REV) for Upscaled Two-Phase Flow in Porous Media

Relative permeability plays an important role in the upscaling of multiphase flow in porous media from the pore scale to the Darcy scale. The entire concept of relative permeability is contingent on the existence of a representative elementary volume (REV). As we move to smaller samples to measure relative permeability, such as with digital core analysis, the concept of a classical REV has become increasingly unlikely when using the conventional approach to defining a representative volume. The “‘conventional”’ understanding of an REV is that a large enough volume must be considered such that spatial variability averages out. In digital rock methods, such as pore-scale simulations based on micro-computed tomography (CT) images, the domain size is typically 2 to 4 mm. This is approximately the length scale of a single-phase flow REV using the classic REV approach. However, the single-phase perspective does not consider the complex dynamics and fluctuations often observed in multiphase flow systems, even at centimeter-scale experiments and/or simulations. A fundamental question is, therefore, whether the domain size commonly used in digital rock simulations can provide a consistent energy budget such that the concept of relative permeability exists. Based on first principles, relative permeability accounts for the rate of energy dissipated in a stationary process. If the dynamics are fluctuating, the energy dissipated can vary but will average out over a long enough timescale. The key to determining the validity of the relative permeability is the timescale of the measurement, not the spatial scale. The conventional REV theory assumes that spatial, temporal, and ensemble averages are equivalent in an ergodic system, but it does not provide a way to test this assumption. We provide a formal way to identify the timescale where the relative permeability accurately captures energy dissipation as a way to validate relative permeability measurements and quantitatively assess their accuracy. This result will be tested for a practical SCAL test, determining how long a flow experiment needs to be run to accurately characterize the rate of energy dissipation by the flow. The outcome will be a best practice guide for the determination of relative permeability from core-scale experiments and/or digital core simulations that ensure the energy budget is fully accounted for in the relative permeability coefficient.

Mcclure, James [Virginia Tech, Blacksburg]↗

Recovering the effects of subgrid heterogeneity in simulations of radionuclide transport through fractured media

Groundwater flow and contaminant transport through fractured media can be simulated using Discrete Fracture Network (DFN) models which provide a natural description of structural heterogeneity. However, this approach is computationally expensive, with the large number of intersecting fractures necessitated by many real-world applications requiring modeling simplifications to be made for calculations to be tractable. Upscaling methods commonly used for this purpose can result in some loss of local-scale variability in the groundwater flow velocity field, resulting in underestimation of particle travel times, transport resistance and retention in transport calculations. In this paper, a transport downscaling algorithm to recover the transport effects of heterogeneity is tested on a synthetic Brittle Fault Zone model, motivated by the problem of large safety assessment calculations for geological repositories of spent nuclear fuel. We show that the variability in the local-scale velocity field which is lost by upscaling can be recovered by sampling from a library of DFN transport paths, accurately reproducing DFN transport statistic distributions and radionuclide breakthrough curves in an upscaled model.

54 ENVIRONMENTAL SCIENCES↗

Techno-Economic Analysis of a Concentrating Solar Power Plant Using Redox-Active Metal Oxides as Heat Transfer Fluid and Storage Media

We present results for a one-dimensional quasi-steady-state thermodynamic model developed for a 111.7 MW e concentrating solar power (CSP) system using a redox-active metal oxide as the heat storage media and heat transfer agent integrated with a combined cycle air Brayton power block. In the energy charging and discharging processes, the metal oxide CaAl 0.2 Mn 0.8 O 2.9-δ (CAM28) undergoes a reversible, high temperature redox cycle including an endothermic oxygen-releasing reaction and exothermic oxygen-incorporation reaction. Concentrated solar radiation heats the redox-active oxide particles under partial vacuum to drive the reduction extent deeper for increased energy density at a fixed temperature, thereby increasing storage capacity while limiting the required on sun temperature. Direct counter-current contact of the reduced particles with compressed air from the Brayton compressor releases stored chemical and sensible energy, heating the air to 1,200°C at the turbine inlet while cooling and reoxidizing the particles. The cool oxidized particles recirculate through the solar receiver subsystem for another cycle of heating and reduction (oxygen release). We applied the techno-economic model to 1) size components, 2) examine intraday operation with varying solar insolation, 3) estimate annual performance characteristics over a simulated year, 4) estimate the levelized cost of electricity (LCOE), and 5) perform sensitivity analyses to evaluate factors that affect performance and cost. Simulations use hourly solar radiation data from Barstow, California to assess the performance of a 111.7 MW e system with solar multiples (SMs) varying from 1.2 to 2.4 and storage capacities of 6–14 h. The baseline system with 6 h storage and SM of 1.8 has a capacity factor of 54.2%, an increase from 32.3% capacity factor with no storage, and an average annual energy efficiency of 20.6%. Calculations show a system with an output of 710 GWh e net electricity per year, 12 h storage, and SM of 2.4 to have an installed cost of $329 million, and an LCOE of 5.98 ¢/kWh e . This value meets the U.S. Department of Energy’s SunShot 2020 target of 6.0 ¢/kWh e ( U. S Department of Energy, 2012 ), but falls just shy of the 5.0 ¢/kWh e 2030 CSP target for dispatchable electricity ( U. S Department of Energy, 2017 ). The cost and performance results are minimally sensitive to most design parameters. However, a one-point change in the weighted annual cost of capital from 8 to 7% (better understood as a 12.5% change) translates directly to an 11% decrease (0.66 ¢/kWhe) in the LCOE.

Gorman, Brandon T.↗

Pore-Scale Analysis of the Permeability Damage and Recovery during Cyclic Freshwater and Brine Injection in Porous Media Containing Non-Swelling Clays

Permeability damage in subsurface porous media caused by clay mobilization is encountered in many engineering applications, such as geothermal energy, water disposal, oil recovery, and underground CO2 storage. During the freshwater injection into rocks containing brine, the sudden decrease in salinity causes native clay fines to detach and clog pore throats, leading to a significant decline in permeability. The clay fines detach due to weakened net-attractive forces binding them to each other and the grain. Past experiments link this permeability damage on the immediate history of the salinity and the direction of flow. To better understand this phenomenon, we conducted pore-scale simulations of cyclic injection of freshwater and brine into sandstone containing Kaolinite clay. Our simulations establish a link between the clay-fine trajectory and the permeability trend observed by Khilar and Fogler (1983). For a uniform clay size of 3 microns, we observe a permeability decline by two orders of magnitude during freshwater injection with respect to brine injection. Increasing salinity and simultaneously reversing flow direction restores the permeability. The permeability restoration upon reversing the brine flow direction is attributed to the unblocking of pore throats in the reverse direction by the movement of the clay particles along the grain surfaces by the hydrodynamic force and the strong net-attractive force under high salinity.

Bhuvankar, Pramod (ORCID:000000027739973X)↗

Data-Driven Reduced-Order Modeling of Convective Heat Transfer in Porous Media

This work presents a data-driven Reduced-Order Model (ROM) for parametric convective heat transfer problems in porous media. The intrusive Proper Orthogonal Decomposition aided Reduced-Basis (POD-RB) technique is employed to reduce the porous medium formulation of the incompressible Reynolds-Averaged Navier–Stokes (RANS) equations coupled with heat transfer. Instead of resolving the exact flow configuration with high fidelity, the porous medium formulation solves a homogenized flow in which the fluid-structure interactions are captured via volumetric flow resistances with nonlinear, semi-empirical friction correlations. A supremizer approach is implemented for the stabilization of the reduced fluid dynamics equations. The reduced nonlinear flow resistances are treated using the Discrete Empirical Interpolation Method (DEIM), while the turbulent eddy viscosity and diffusivity are approximated by adopting a Radial Basis Function (RBF) interpolation-based approach. The proposed method is tested using a 2D numerical model of the Molten Salt Fast Reactor (MSFR), which involves the simulation of both clean and porous medium regions in the same domain. For the steady-state example, five model parameters are considered to be uncertain: the magnitude of the pumping force, the external coolant temperature, the heat transfer coefficient, the thermal expansion coefficient, and the Prandtl number. For transient scenarios, on the other hand, the coastdown-time of the pump is the only uncertain parameter. The results indicate that the POD-RB-ROMs are suitable for the reduction of similar problems. The relative L2 errors are below 3.34% for every field of interest for all cases analyzed, while the speedup factors vary between 54 (transient) and 40,000 (steady-state).

German, Péter (ORCID:0000000307285283)↗

One and Two Dimensional Quantum Lattice Algorithms for Maxwell Equations in Inhomogeneous Scalar Dielectric Media. II: Simulations

Long time quantum lattice algorithm (QLA) simulations are performed for the mul- tiple reflection-transmission of an initial electromagnetic pulse propagating normally to a boundary layer region joining two media of different refractive index. For these one dimensional (1D) sim- ulations, there is excellent agreement between x-, y- and z- representations, as well as very good agreement with nearly all the standard plane wave boundary condition results for reflection and transmission off a dielectric discontinuity. In the QLA simulation, no boundary conditions are im- posed at the continuous, but sharply increasing, dielectic boundary layers. Two dimensional (2D) QLA scattering simulations in the x-z plane are performed for an electromagnetic pulse interacting with a conical dielectric obstacle for the 8-16 qubit model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

One and Two Dimensional Quantum Lattice Algorithms for Maxwell Equations in Inhomogeneous Scalar Dielectric Media I: Theory

A quantum lattice algorithm (QLA) is developed for Maxwell equations in scalar dielectric media using the Riemann-Silberstein representation on a Cartesian grid. For x-dependent and y-dependent dielectric inhomogeneities, the corresponding QLA requires a minimum of 8 qubits/spatial lattice site. This is because the corresponding Pauli spin matrices have off-diagonal components which permit the local collisional entanglement of these qubits. However, z-dependent inhomogeneities require a QLA with a minimum of 16 qubits/lattice site since the Pauli spin matrix σz is diagonal. For 2 dimensional inhomogeneities, one can readily couple the 8-8 qubit schemes for x-y variations. z-x and y-z variations can be treated by either a 16-8 qubit scheme or a 16-16 qubit representation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗