At least 397 records · Page 22

Solar tests of aperture plate materials for solar thermal dish collectors

If a malfunction occurs in a solar thermal point-focus distributed receiver power plant while a concentrator is pointed at the sun, motion of the concentrator may stop. As the sun moves relative to the earth, the spot of concentrated sunlight then slowly walks off the receiver aperture, across the receiver face plate, and perhaps across adjacent portions of the concentrator. Intense local heating by the concentrated sunlight may damage or destroy these parts. The behavior of various materials under conditions simulating walk-off of a parabolic dish solar collector were evaluated. Each test consisted of exposure to concentrated sunlight at a peak flux density of about 7000 kW/square meter for 15 minutes. Types of materials tested included graphite, silicon carbide, silica, various silicates, alumina, zirconia, aluminum, copper, steel, and polytetrafluoroethylene. The only material that neither cracked nor melted was grade G-90 graphite. Grade CS graphite, a lower cost commercial grade, cracked half-way across, but did not fall apart. Both of these grades are medium-grain extruded graphites. A graphite cloth (graphitized polyacrylonitrile) showed fair performance when tested as a single thin ply; it might be useful as a multi-ply assembly. High purity slipcast silica showed some promise also.

Jaffe, L. D.↗

Integrated FHR technology development: Tritium management, materials testing, salt chemistry control, thermal hydraulics and neutronics, associated benchmarking and commercial basis

This report summarizes the results of a 3-year Integrated Research Project (IRP) sponsored by the U.S. Department of Energy to address major technical challenges in the development of the Fluoride-salt-cooled High-temperature Reactor (FHR). The IRP universities included the Massachusetts Institute of Technology (MIT), the University of California at Berkeley (UCB), the University of Wisconsin (UW), and the University of New Mexico (UNM). The FHR is a new reactor concept less than 20 years old that combines (1) a clean fluoride salt coolant, (2) the graphite-matrix coated-particle fuel originally developed for High- Temperature Gas-Cooled Reactors and (3) passive decay heat removal systems from sodium fast reactors. The base-line design is a pebble-bed FHR that delivers heat between 600 to 700°C with a 7 Li 2 BeF 4 (flibe) salt coolant to the power cycle or industrial users. The Executive Summary describes what was accomplished and summarizes major conclusions. The main report contains stand-alone sections in each major area of work. Highlights are summarized below. Tritium. The coolant salt produces tritium necessitating understanding and control of tritium. Experimental work included measuring hydrogen uptake on carbon, tritium uptake during irradiation of graphite in 700°C salt and the permeability of tritium through metals with and without coatings. An FHR systems model was developed to predict tritium behavior and enable design of tritium control systems. The leading candidate for tritium removal from the flibe salt is carbon bed outside the reactor core. Thermal hydraulics and Neutronics. A 10-meter high FHR integral effects test facility, using Dowtherm A®, has been built and used to simulate the integral response of a representative FHR to improve understanding of FHR thermal hydraulics and validate thermal hydraulics codes used for the FHR. Neutronic analysis included code-to-code benchmarking, multiphysics modeling, uncertainty analysis for nuclear data uncertainties and shielding analysis. Twisted-tube heat exchangers were examined that may provide significant cost reductions because of their improved heat-transfer performance with liquid salts. The impacts on safety and design caused by uncertainties in physical properties of the salt were assessed with recommendations on where added physical property measurements are needed. Work began on understanding radiative heat transfer that becomes important in salt systems at higher temperatures. Materials. Static corrosion tests were conducted on graphite and materials in 700°C salt -- both in the UW laboratory and in the MIT reactor. In addition to static corrosion testing, a circulating salt corrosion loop was built and is operating. Methods to measure salt properties including redox were developed. The presence of carbon increases corrosion. With good redox control, the evidence indicates stainless steel can be used as a material of construction. Benchmarking. An additional series of workshops where held to enable benchmarking and comparison of results between different investigators. Commercialization. The FHR delivers higher average-temperature (~650°C) heat to the power cycle or industry than other reactors. This enables power cycles with lower-cost heat storage for variable electricity to the grid while the reactor operates at base-load -- providing a major competitive advantage by maximizing revenue from electricity sales. In October, 2016, a new startup company named Kairos Power was formed, and opened its first office in Jack London Square, Oakland, California, in January 2017. Kairos Power exists largely due to the work that was accomplished by this IRP and the previous DOE-funded FHR IRP that performed research on FHR technology from 2012 to 2015. In September, 2018, as this IRP is concluding, Kairos Power was staffed at 60 full time employees, working to develop technology derived from this IRP. Many of these employees worked with the IRP before joining Kairos Power 1 (https://kairospower.com). Other students and researchers from this IRP have joined other startup companies, including the Terrapower Molten Chloride Fast Reactor and the Terrestrial Energy development efforts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The efficiency calibration of the DSS-24 34-meter beam-waveguide antenna

Microwave performance testing of the new Deep Space Station (DSS)-24 34-m-diameter antenna was carried out during the summer of 1994. Efficiency measurements were made at the 8.45 GHz (X-band) and 32-GHz (ka-band) frequencies both at the antenna Cassegrian (f1) and beam-waveguide (f3) focal points. In addition, the antenna f3 efficiencies were measured on the DSS-24 operational 2.295-GHz (S-band) and 8.45-Ghz feeds. This article presents the efficiency determinations as a function of elevation angle along with a corresponding error analysis of the measurements. Peak measured gains and efficiencies are tabulated for all frequencies.

Alvarez, L. S.↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

Multicyclic jet-flap control for alleviation of helicopter blade stresses and fuselage vibration

Results of wind tunnel tests of a 12 meter-diameter-rotor utilizing multicyclic jet-flap control deflection are presented. Analyses of these results are shown, and experimental transfer functions are determined by which optimal control vectors are developed. These vectors are calculated to eliminate specific harmonic bending stresses, minimize rms levels (a measure of the peak-to-peak stresses), or minimize vertical vibratory loads that would be transmitted to the fuselage. Although the specific results and the ideal control vectors presented are for a specific jet-flap driven rotor, the method employed for the analyses is applicable to similar investigations. A discussion of possible alternative methods of multicyclic control by mechanical flaps or nonpropulsive jet-flaps is presented.

Mccloud, J. L., III↗

Multicyclic jet-flap control for alleviation of helicopter blade stresses and fuselage vibration

Results of wind tunnel tests of a 12-meter-diameter rotor utilizing multicyclic jet-flap control deflection are presented. Analyses of these results are shown, and experimental transfer functions are determined by which optimal control vectors are developed. These vectors are calculated to eliminate specific harmonic bending stresses, minimize rms levels (a measure of the peak-to-peak stresses), or minimize vertical vibratory loads that would be transmitted to the fuselage. Although the specific results and the ideal control vectors presented are for a specific jet-flap driven rotor, the method employed for the analyses is applicable to similar investigations. A discussion of possible alternative methods of multicyclic control by mechanical flaps or nonpropulsive jet-flaps is presented.

Mccloud, J. L., III↗

Dynamic calibration of flowmeter

Technique for flowmeters has been developed and tested whereby fluid flows through meter at constant velocity while flowmeter is forced to oscillate relative to fluid.

Herr, R. W.↗

Test-vehicle cycle programmer

Instrument reduces manpower needed for testing electric powered vehicles. Device has dual scale that allows operator to compare actual speed with preprogrammed test speed. Features include large meter, buzzer, packaging to allow ready interchange of memories with different profiles, small size, minimal current drain, and reverse supply voltage protection.

Lesco, D. J.↗

Propagation of sound through the Earth's atmosphere. 1: Measurement of sound absorption in the air: 2: Measurement of ground impedance

Parts were fabricated for the acoustic ground impedance meter and the instrument was tested. A rubber hose was used to connect the resonator neck to the chamber in order to suppress vibration from the volume velocity source which caused chatter. An analog to digital converter was successfully hardwired to the computer detection system. The cooling system for the resonant tube was modified to use liquid nitrogen cooling. This produced the required temperature for the tube, but the temperature gradients within each of the four tube sections reached unacceptable levels. Final measurements of the deexcitation of nitrogen by water vapor indicate that the responsible physical process is not the direct vibration-translation energy transfer, but is a vibration-vibration energy transfer.

Meredith, R. W.↗

Investigation of trailing-edge-flap, spanwise-blowing concepts on an advanced fighter configuration

The aerodynamic effects of spanwise blowing on the trailing edge flap of an advanced fighter aircraft configuration were determined in the 4 by 7 Meter Tunnel. A series of tests were conducted with variations in spanwise-blowing vector angle, nozzle exit area, nozzle location, thrust coefficient, and flap deflection in order to determine a superior configuration for both an underwing cascade concept and an overwing port concept. This screening phase of the testing was conducted at a nominal approach angle of attack from 12 deg to 16 deg; and then the superior configurations were tested over a more complete angle of attack range from 0 deg to 20 deg at tunnel free stream dynamic pressures from 20 to 40 lbf/sq ft at thrust coefficients from 0 to 2.

Paulson, J. W., Jr.↗

Side effects of antimotion sickness drugs

The effects on operational proficiency of the antimotion sickness drugs scopolamine, promethazine and d-amphetamine are tested using a computerized pursuit meter. Proficiency is not significantly affected by oral doses of 0.25 mg or 0.50 mg scopolamine but is descreased by oral or I.M. doses of 25 mg promethazine. The performance decrement associated with 25 mg oral promethazine is prevented when combined with 10 mg oral d-amphetamine. The combination of 25 mg I.M. promethazine, 25 mg oral promethazine and 10 mg d-amphetamine produces less performance decrement than oral or I.M. doses of promethazine alone, though more performance decrement than a placebo. I.M. promethazine is adsorbed slowly and consequently may provoke drowsiness.

Wood, C. D.↗

A study of laminar separation bubble in the concave region of an airfoil using laser velocimetry

Laser velocimetry (LV) was used to study the nature of laminar separation bubbles in the concave region of a 1.83-meter airfoil model which was tested in the NASA Langley Low Turbulence Pressure Tunnel. Three component, coincident data from LV measurements including histograms of particle velocity, mean velocity profiles, turbulence intensity, and Reynolds stresses within the shear layer were used to determine the locations of laminar separation, transition, and turbulent reattachment. boundary-layer parameters determined from velocity profiles were used to compare the results with existing empirical relations for describing the laminar separation bubble.

Mangalam, S. M.↗

Assembly considerations for large reflectors

The technologies developed at LaRC in the area of erectable instructures are discussed. The information is of direct value to the Large Deployable Reflector (LDR) because an option for the LDR backup structure is to assemble it in space. The efforts in this area, which include development of joints, underwater assembly simulation tests, flight assembly/disassembly tests, and fabrication of 5-meter trusses, led to the use of the LaRC concept as the baseline configuration for the Space Station Structure. The Space Station joint is linear in the load and displacement range of interest to Space Station; the ability to manually assemble and disassemble a 45-foot truss structure was demonstrated by astronauts in space as part of the ACCESS Shuttle Flight Experiment. The structure was built in 26 minutes 46 seconds, and involved a total of 500 manipulations of untethered hardware. Also, the correlation of the space experience with the neutral buoyancy simulation was very good. Sections of the proposed 5-meter bay Space Station truss have been built on the ground. Activities at LaRC have included the development of mobile remote manipulator systems (which can traverse the Space Station 5-meter structure), preliminary LDR sun shield concepts, LDR construction scenarios, and activities in robotic assembly of truss-type structures.

Bush, H.↗

Low flow vortex shedding flowmeter for hypergolics/all media

A family of vortex shedding flowmeters for flow measurement of hypergols that requires a long term operation without removal from system lines was further developed. A family of vortex shedding flowmeters without moving parts was designed. The test loop to evaluate the meters for the Freon flow, which simulates the hypergolic fluids, was modified and reconstructed. Preliminary results were obtained on the output frequency characteristics of an 1/2 inch flowmeter as a function of the flow rate.

Thinh, Ngo↗

Experimental apparatus for the study of propellers

The apparatus consists of a universal balance with transmission at variable speeds from 300 to 5,000 rpm and a group directly coupled to the model for speeds of 5 to 30,000 revolutions. This new apparatus was also designed with a torsion meter for measuring the torque. Tests were conducted on the effect of the angle between the propeller axis and the wind direction. The results presented correspond to a first series of tests made without an interposed wing and in which the distance between the plane of the propeller disk and the tail was maintained constant.

Panetti, M↗