Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscopic analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Chemical and structural studies of 'Brownlee' particles

Several techniques were applied to the study of small particles (around 10 microns) collected in the upper atmosphere by U-2 aircraft. The major element chemistry of roughly 1/3 of the particles is similar to that of chondritic meteorites, although considerable variation of element ratios is observed from particle to particle, and even within a given particle. All particles of 'chondritic' composition are polycrystalline aggregates. About half have fully re-entrant structures; the remaining ones have more compact structures ranging from platey to spherical morphologies. Micro-crystallites with various internal structures are observed in the size range from less than 100 A to several microns. Although tracks are clearly observed in transmission electron microscope examination of terrestrial analog crystals, no tracks of solar flare origin have yet been identified in the U-2 particles. Induced fission track analysis of one aggregate shows that the U concentration is less than 15 ppbm, lending support to the extraterrestrial origin hypothesis.

Flynn, G. J.↗

Mechanical properties testing of candidate polymer matrix materials for use in high performance composites

The mechanical properties of four candidate neat resin systems for use in graphite/epoxy composites are characterized. This includes tensile and shear stiffnesses and strengths, coefficients of thermal and moisture expansion, and fracture toughness. Tests are conducted on specimens in the dry state and moisture-saturated, at temperatures of 23C, 82C and 121C. The neat resins tested are Hexcel HX-1504, Narmco 5245-C, American Cyanamid CYCOM 907, and Union Carbide ERX-4901A (MDA). Results are compared with those obtained for four other epoxy resins tested in a prior program, i.e., Hercules 3502, 2220-1, and 2220-3, and Ciba-Geigy Fibredux 914, as well as with available Hercules 3501-6 data. Scanning electron microscopic examination of fracture surfaces is performed to permit the correlation of observed failure modes with the environmental test conditions. A finite element micromechanics analysis is used to predict unidirectional composite response under various test conditions, using the measured neat resin properties as input data.

Zimmerman, R. S.↗

Exploration of the Eltanin Impact Area (Bellingshausen Sea): Expedition ANT XVIII5a

The impact of the Eltanin asteroid into the Bellingshausen Sea (2.15 Ma) is the only known impact in a deep-ocean (approx. 5 km) basin. On 26 March 2001, the FS Polarstern returned to the impact area during expedition ANT XVIII/5a. Over a period of 14 days, this region was explored by detailed bathymetric mapping, acoustic profiling of sediment deposits, and direct sampling with 18 piston cores and four gravity cores. Preliminary shipboard examination of microfossils showed that sixteen of the piston cores and three gravity cores contained sediments at least as old as the impact event and have a high probability of containing a record of the disturbances caused by the impact. During the expedition, portions of eleven piston cores were opened for preliminary examination of the impact deposits. Visual examination of cores and microscopic identification of suspect impact melt particles were were used to identify ejecta and X-ray radiographs of the opened core segments permitted analysis of sediment structures. Impact deposits were found in nine of the eleven opened cores, and a similar success rate is anticipated in the seven cores remaining to be opened. These preliminary observations indicate that the highest concentrations of meteoritic ejecta and the largest particle sizes appear to occur in the region north of the San Martin seamounts. Recovered debris includes cm-sized melt rocks and a 2.5 cm meteorite. This expedition has confirmed the presence of high concentrations of meteoritic ejecta across a region at least as large as 10(exp 5) sq km. Quantitative analyses of ejecta distribution within this region will require further study, but previous estimates of 1 km for the minimum diameter of the Eltanin asteroid, appear safe.

Gersonde, Rainer↗

Water on Mars: Evidence from MER Mission Results

The Viking and the Mars Exploration Rover missions observed that the surface of Mars is encrusted by a thinly cemented layer, or "duricrust". Elemental analyzes at five sites on Mars show that these soils have sulfur content and chlorine content consistent with the presence of sulfates and halides as mineral cements. The soil is highly enriched in the salt-forming elements compared with rock. Analysis of the soil cementation indicates some features which may be evidence of liquid water. At both MER sites, duricrust textures revealed by the Microscopic Imager show features including the presence of fine sand-sized grains, some of which may be aggregates of fine silt and clay, surrounded by a pervasive light colored material that is associated with microtubular structures and networks of microfractures. Stereo views of undisturbed duricrust surfaces reveal rugged microrelief between 2-3 mm and minimal loose material. Comparisons of microscopic images of duricrust soils obtain before and after placement of the Mossbauer spectrometer indicate differing degrees of compaction and cementation. Two models of a transient water hypothesis are offered, a "top down" hypothesis that emphasizes the surface deposition of frost, melting and downward migration of liquid water and a "bottom up" alternative that proposes the presence of interstitial ice/brine, with the upward capillary migration of liquid water. The viability of both of these models ultimately hinges on the availability of seasonally transient liquid water for brief periods.

Landis, Geoffrey A.↗

Modeling a Miniaturized Scanning Electron Microscope Focusing Column - Lessons Learned in Electron Optics Simulation

This presentation discusses work done to assess the design of a focusing column in a miniaturized Scanning Electron Microscope (SEM) developed at the NASA Marshall Space Flight Center (MSFC) for use in-situ on the Moon-in particular for mineralogical analysis. The MSFC beam column design uses purely electrostatic fields for focusing, because of the severe constraints on mass and electrical power consumption imposed by the goals of lunar exploration and of spaceflight in general. The resolution of an SEM ultimately depends on the size of the focused spot of the scanning beam probe, for which the stated goal here is a diameter of 10 nanometers. Optical aberrations are the main challenge to this performance goal, because they blur the ideal geometrical optical image of the electron source, effectively widening the ideal spot size of the beam probe. In the present work the optical aberrations of the mini SEM focusing column were assessed using direct tracing of non-paraxial rays, as opposed to mathematical estimates of aberrations based on paraxial ray-traces. The geometrical ray-tracing employed here is completely analogous to ray-tracing as conventionally understood in the realm of photon optics, with the major difference being that in electron optics the lens is simply a smoothly varying electric field in vacuum, formed by precisely machined electrodes. Ray-tracing in this context, therefore, relies upon a model of the electrostatic field inside the focusing column to provide the mathematical description of the "lens" being traced. This work relied fundamentally on the boundary element method (BEM) for this electric field model. In carrying out this research the authors discovered that higher accuracy in the field model was essential if aberrations were to be reliably assessed using direct ray-tracing. This led to some work in testing alternative techniques for modeling the electrostatic field. Ultimately, the necessary accuracy was attained using a BEM/Fourier series hybrid approach. The presentation will give background remarks about the MSFC mini Lunar SEM concept and electron optics modeling, followed by a description of the alternate field modeling techniques that were tried, along with their incorporation into a ray-trace simulation. Next, the validation of this simulation against commercially available software will be discussed using an example lens as a test case. Then, the efficacy of aberration assessment using direct ray-tracing will be demonstrated, using this same validation case. The discussion will include practical error checks of the field solution. Finally, the ray-trace assessment of the MSFC mini Lunar SEM concept will be shown and discussed. The authors believe this presentation will be of general interest to practitioners of modeling and simulation, as well as those with a general optics background. Because electron optics and photon optics share many basic concepts (e.g., lenses, images, aberrations, etc.), the appeal of this presentation need not be restricted to just those interested in charged particle optics.

Modeling Miniaturizing Scanning↗

Surveys of ISS Returned Hardware for MMOD Impacts

Since February 2001, the Hypervelocity Impact Technology (HVIT) group at the Johnson Space Center in Houston has performed 26 post-flight inspections on space exposed hardware that have been returned from the International Space Station. Data on 1,024 observations of MMOD damage have been collected from these inspections. Survey documentation typically includes impact feature location and size measurements as well as microscopic photography (25-200x). Sampling of impacts sites for projectile residue was performed for the largest features. Results of Scanning Electron Microscopy (SEM) analysis to discern impactor source is included in the database. This paper will summarize the post-flight MMOD inspections, and focus on two inspections in particular: (1) Pressurized Mating Adapter-2 (PMA-2) cover returned in 2015 after 1.6 years exposure with 26 observed damages, and (2) Airlock shield panels returned in 2010 after 8.7 years exposure with 58 MMOD damages. Feature sizes from the observed data are compared to predictions using the Bumper risk assessment code.

Hyde, James↗

XRF Characterization of MMOD Impact Damage

Introduction The Hypervelocity Impact Technology (HVIT) Group at the NASA Johnson Space Center (JSC) has performed over 150 post flight MMOD inspections on returned space-ex-posed hardware and collected over 1,600 samples. Determination of the impactor source typically requires an analysis of the projectile residue in the damage feature. At this time, about 20% of the samples have been processed. Types of Samples Samples in the HVIT group collection can be classified into two types. Indirect (non-destructive) samples are produced when a pliable material (e.g., adhesive tape or dental mold) is inserted into an impact feature. With this type of sampling technique, crater material and (hopefully) projectile residue material is embedded in the sample media and can detected using further chemical characterizing techniques. Direct (destructive) sampling involves the in-tact extraction of material from the spacecraft and is done in a manner that the entire impact feature can be excised intact. This technique provides the greatest chance of successfully determining impactor source due to the entirety of the projectile remnants being present within the collected sample. Updated Projectile Residue Detection Techniques Previous assessments of projectile provenance have involved the use of samples that are first mounted in epoxy, sectioned to expose the crater interior, imaged with a scanning electron microscope (SEM), then any observed impactor residue was then analyzed using an energy dispersive spectrometer (EDS). This technique, while proven, may be supplemented with other types of elemental analysis techniques that can observe major element chemistry, in order to improve throughput of sample analysis. The Astromaterials Research and Exploration Science (ARES) Division at JSC, for example, operates a Bruker M4 Tornado micro-X-Ray fluorescence (XRF) spectrometer, capable of creating elemental maps of areas around these small impact features in a couple of hours, with a spot size <20 μm. The potential advantage with this technique lies in sample preparation, as no polishing or conductive coatings are needed. Early trials attempted to deter-mine impactor composition by collecting spectra from intact samples by aiming the X-Rays directly into the impact feature, but the signal:noise ratio was too low for confident material identification. Sample preparation for XRF then relies on sectioning the samples parallel to the impactor trajectory in order to expose the largest area of subsurface damage possible, thus maximizing the signal from any small impactor remnants. Complementary to the use of XRF for sample analysis, ARES also houses a Nikon XTH 320 micro-X-Ray computed tomography (XCT). This instrument can be used to create 3D visualizations of impact damage for the determination of crater volumes and dimensions, as well as for the determination of the best place to section each sample for the subsequent XRF analysis.

J L Hyde↗

Sedimentological Investigations of the Martian Surface using the Mars 2001 Robotic Arm Camera and MECA Optical Microscope

The first microscopic sedimentological studies of the Martian surface will commence with the landing of the Mars Polar Lander (MPL) December 3, 1999. The Robotic Arm Camera (RAC) has a resolution of 25 um/p which will permit detailed micromorphological analysis of surface and subsurface materials. The Robotic Ann will be able to dig up to 50 cm below the surface. The walls of the trench will also be inspected by RAC to look for evidence of stratigraphic and / or sedimentological relationships. The 2001 Mars Lander will build upon and expand the sedimentological research begun by the RAC on MPL. This will be accomplished by: (1) Macroscopic (dm to cm): Descent Imager, Pancam, RAC; (2) Microscopic (mm to um RAC, MECA Optical Microscope (Figure 2), AFM This paper will focus on investigations that can be conducted by the RAC and MECA Optical Microscope.

Rice, J. W., Jr.↗

A study of microstructural characteristics of Ni-based superalloys at high temperatures

The microstructural characteristics of the Ni-based superalloy MAR-M246(Hf) which is used in manufacturing the components of the Space Shuttle's main engine have been studied. These superalloys need optimal heat treatment to get the best results. To find the optimum heat treatment the technique of differential thermal analysis and the optical photomicrographs are being planned to be utilized. In the first phase, the existing experimental equipment like cutting, grinding/polishing machines and metallurgical microscope have been set up to cut/polish and take the photomicrographs. In the beginning of this year an order was placed for the Leitz Mettalux-3 microscope with a hot stage for in-situ observation of the superalloy samples. The hot stage was tested for the first time, alloying the thermocouple with the Tantulum heating element and has not been installed finally by the supplier. A Perkin Elmer Differential Thermal Analyzer (DTA 1700) was procured in the first year of the project. Samples of MAR-M246(Hf), MAR-M247, Waspaloy, Udimet-41, CMSX-2 and CMSX-3 (polycrystalline and single crystals) have been studied using differential thermal analyzer.

Lal, R. B.↗

Atomic Oxygen (ATOX) simulation of Teflon FEP and Kapton H surfaces using a high intensity, low energy, mass selected, ion beam facility

A high intensity (greater than 10(exp 15) ions/sq cm) low energy (down to 5 eV) mass selected ion beam (MSIB) facility was used to study the effects of ATOX on two polymers commonly used for space applications (Kapton H and Teflon FEP). The polymers were exposed to O(+) and Ne(+) fluences on 10(exp 15) - 10(exp 19) ions/sq cm, using 30eV ions. A variety of analytical methods were used to analyze the eroded surfaces including: (1) atomic force microscopy (AFM) for morphology measurements; (2) total mass loss measurements using a microbalance; (3) surface chemical composition using x-ray photoelectron spectroscopy (XPS), and (4) residual gas analysis (RGA) of the released gases during bombardment. The relative significance of the collisional and chemical degradation processes was evaluated by comparing the effects of Ne(+) and O(+) bombardment. For 30 eV ions it was found that the Kapton is eroded via chemical mechanisms while Teflon FEP is eroded via collisional mechanisms. AFM analysis was found very powerful in revealing the evolution of the damage from its initial atomic scale (roughness of approx. 1 nm) to its final microscopic scale (roughness greater than 1 micron). Both the surface morphology and the average roughness of the bombarded surfaces (averaged over 1 micron x 1 micron images by the system's computer) were determined for each sample. For 30 eV a non linear increase of the Kapton roughness with the O(+) fluence was discovered (a slow increase rate for fluences phi less than 5 x 10(exp 17) O(+)/sq cm, and a rapid increase rate for phi greater than 5 x 10(exp 17) O(+)/sq cm). Comparative studies on the same materials exposed to RF and DC oxygen plasmas indicate that the specific details of the erosion depend on the simulation facility emphasizing the advantages of the ion beam facility.

Vered, R.↗

High-Fidelity Micromechanics Model Developed for the Response of Multiphase Materials

A new high-fidelity micromechanics model has been developed under funding from the NASA Glenn Research Center for predicting the response of multiphase materials with arbitrary periodic microstructures. The model's analytical framework is based on the homogenization technique, but the method of solution for the local displacement and stress fields borrows concepts previously employed in constructing the higher order theory for functionally graded materials. The resulting closed-form macroscopic and microscopic constitutive equations, valid for both uniaxial and multiaxial loading of periodic materials with elastic and inelastic constitutive phases, can be incorporated into a structural analysis computer code. Consequently, this model now provides an alternative, accurate method.

Aboudi, Jacob↗

SIMS chemical analysis of extended impacts on the leading and trailing edges of LDEF experiment AO187-2

The Long Duration Exposure Facility (LDEF) Experiment AO187-2 consisted of 237 capture cells, 120 on the leading edge and 117 on the trailing edge. Each cell was made of polished Ge plates covered with 2.5 micron thick mylar foil at 200 microns from the Ge. Although all leading edge cells and 105 trailing edge cells had lost their plastic covers during flight, optical and electron microscope examination revealed extended impacts in bare cells from either edge that apparently were produced by high velocity projectiles while the plastic foils were still in place. Detailed optical scanning yielded 53 extended impacts on 100 bare cells from the trailing edge that were selected for SIMS chemical analysis. Lateral multi-element ion probe profiles were obtained on 40 of these impacts. Material that can be attributed to the incoming projectiles was found in all analyzed extended compact features and most seem to be associated with cosmic dust particles. However, LDEF deposits are systematically enriched in the refractory elements Al, Ca, and Ti relative to Mg and Fe when compared to IDP's collected in the stratosphere and to chondritic compositions. These differences are most likely due to elemental fractionation effects during the high velocity impact but real differences between interplanetary particles captured on LDEF and stratospheric IDP's cannot be excluded. Recently we extended our studies to cells from the leading edge and the covered cells from the trailing edge. The 12 covered cells contain 20 extended impact candidates. Ion probe analysis of 3 yielded results similar to those obtained for impacts on the bare cells from the trailing edge. Optical scanning of the bare leading edge cell also reveals many extended impacts (42 on 22 cells scanned to date), demonstrating that the cover foils remained intact at least for some time. However, SIMS analysis showed elements that can reasonably be attributed to micrometeoroids in only 2 out of 11 impacts. Eight impacts have residues dominated by Al and one dominated by Ti, indicating a preponderance of orbital debris in leading edge impacts.

Amari, S.↗

Edge-defined film-fed growth of thin silicon sheets

Finite element analysis was used on two length scales to understand crystal growth of thin silicon sheets. Thermal-capillary models of entire ribbon growth systems were developed. Microscopic modeling of morphological structure of melt/solid interfaces beyond the point of linear instability was carried out. The application to silicon system is discussed.

Ettouney, H. M.↗

Notch Sensitivity of Woven Ceramic Matrix Composites Under Tensile Loading: An Experimental, Analytical, and Finite Element Study

The stress concentrations associated with circular notches and subjected to uniform tensile loading in woven ceramic matrix composites (CMCs) have been investigated for high-efficient turbine engine applications. The CMC's were composed of Nicalon silicon carbide woven fabric in SiNC matrix manufactured through polymer impregnation process (PIP). Several combinations of hole diameter/plate width ratios and ply orientations were considered in this study. In the first part, the stress concentrations were calculated measuring strain distributions surrounding the hole using strain gages at different locations of the specimens during the initial portion of the stress-strain curve before any microdamage developed. The stress concentration was also calculated analytically using Lekhnitskii's solution for orthotropic plates. A finite-width correction factor for anisotropic and orthotropic composite plate was considered. The stress distributions surrounding the circular hole of a CMC's plate were further studied using finite element analysis. Both solid and shell elements were considered. The experimental results were compared with both the analytical and finite element solutions. Extensive optical and scanning electron microscopic examinations were carried out for identifying the fracture behavior and failure mechanisms of both the notched and notched specimens. The stress concentration factors (SCF) determined by analytical method overpredicted the experimental results. But the numerical solution underpredicted the experimental SCF. Stress concentration factors are shown to increase with enlarged hole size and the effects of ply orientations on stress concentration factors are observed to be negligible. In all the cases, the crack initiated at the notch edge and propagated along the width towards the edge of the specimens.

Haque, A.↗

Two Years of Chemical Sampling on Meridiani Planum by the Alpha Particle X-Ray Spectrometer Onboard the Mars Exploration Rover Opportunity

For over two terrestrial years, the Mars Exploration Rover Opportunity has been exploring the martian surface at Meridiani Planum using the Athena instrument payload [1], including the Alpha Particle X-Ray Spectrometer (APXS). The APXS has a small sensor head that is mounted on the robotic arm of the rover. The chemistry, mineralogy and morphology of selected samples were investigated by the APXS along with the Moessbauer Spectrometer (MB) and the Microscopic Imager (MI). The Rock Abrasion Tool (RAT) provided the possibility to dust and/or abrade rock surfaces down to several millimeters to expose fresh material for analysis. We report here on APXS data gathered along the nearly 6-kilometers long traverse in craters and plains of Meridiani.

Bruckner, J.↗

Micrometeoroid Impacts on the Hubble Sace Telescope Wide Field and Planetary Camera 2: Ion Beam Analysis of Subtle Impactor Traces

Recognition of origin for particles responsible for impact damage on spacecraft such as the Hubble Space Telescope (HST) relies upon postflight analysis of returned materials. A unique opportunity arose in 2009 with collection of the Wide Field and Planetary Camera 2 (WFPC2) from HST by shuttle mission STS-125. A preliminary optical survey confirmed that there were hundreds of impact features on the radiator surface. Following extensive discussion between NASA, ESA, NHM and IBC, a collaborative research program was initiated, employing scanning electron microscopy (SEM) and ion beam analysis (IBA) to determine the nature of the impacting grains. Even though some WFPC2 impact features are large, and easily seen without the use of a microscope, impactor remnants may be hard to find.

Grime, G. W.↗

Surveys of Returned ISS Hardware for MMMOD Impacts

Since February 2001, the Hypervelocity Impact Technology (HVIT) group at the Johnson Space Center (JSC) in Houston has performed 35 post-flight inspections on space exposed hardware returned from the International Space Station (ISS). Data on 1,188 observations of micrometeoroid and orbital debris (MMOD) damage have been collected from these inspections. Survey documentation typically includes impact feature location and size measurements as well as microscopic photography (25-200x). Sampling of impacts sites for projectile residue was performed for the largest features. Results of energy dispersive X-ray spectroscopic analysis to discern impactor source are included in the database when available. This paper will focus on two inspections, the Pressurized Mating Adapter 2 (PMA-2) cover returned in 2015 after 1.6 years exposure with 26 observed impact features, and two Airlock shield panels returned in 2010 after 8.75 years exposure with 58 MMOD impacts. Feature sizes from the observed data are compared to predictions using the Bumper 3 risk assessment code.

Hyde, J. L.↗

Space Weathering in OSIRIS-REx Samples From Bennu: Impact Melt Deposits

Early analyses of regolith samples from asteroid Bennu delivered by the OSIRIS-REx spacecraft showed a mineralogy dominated by hydrated silicates, sulfides, magnetite, phosphates, and abundant organic matter, in addition to other minor/trace phases. A major objective of the sample analysis campaign is to understand the nature and extent of space weathering processes recorded by returned samples from Bennu. Here we report our preliminary transmission electron microscope (TEM) observations of impact melt deposits on surfaces of Bennu sample particles.

L. P. Keller↗