Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear spectral function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

RHESSI TESTS OF QUASI-THERMAL GAMMA-RAY BURST SPECTRAL MODELS

Prompt gamma-ray burst (GRB) spectra evolve on short timescales, suggesting that time-resolved spectral fits may help diagnose the still unknown prompt emission mechanism. We use broadband gamma-ray data from the Ramaty High-Energy Solar Spectroscopic Imager spacecraft to test quasi-thermal models with high signal-to-noise time-resolved spectra of nine bright GRBs. In contrast to results reported in more narrow energy bands, the quality of the fits of quasi-thermal models is poor in relation to fits of the phenomenological Band function. Moreover, the best-fit parameters for the simplest quasi-thermal model, a blackbody plus a nonthermal power law, show significant dependence on the fit band. Models that replace the power law with more complicated nonthermal functions are not robust for the data considered here and decrease the physical relevance of the fit blackbody.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffraction gratings with two-orders-of-magnitude-enhanced dispersion rates for sub-meV resolution soft X-ray spectroscopy

Diffraction gratings with large angular dispersion rates are central to obtaining high spectral resolution in grating spectrometers operating over a broad spectral range from infrared to soft X-ray domains. The greatest challenge is of course to achieve large dispersion rates in the short-wavelength X-ray domain. Here it is shown that crystals in non-coplanar asymmetric X-ray Bragg diffraction can function as high-reflectance broadband soft X-ray diffraction gratings with dispersion rates that are at least two orders of magnitude larger than those that are possible with state-of-the-art man-made gratings. Additionally, this opens new opportunities to design and implement soft X-ray resonant inelastic scattering (RIXS) spectrometers with spectral resolutions that are up to two orders of magnitude higher than what is currently possible, to further advance a very dynamic field of RIXS spectroscopy, and to make it competitive with inelastic neutron scattering. Examples of large-dispersion-rate crystal diffraction gratings operating near the 930 eV L 3 absorption edge in Cu and of the 2.838 keV L 3 -edge in Ru are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Acoustic Emission signal acquired by the microphones placed in the CABRI test device along the fourteen last R.I.A. experiments: an example of reproducible research in nuclear science

The CABRI facility is an experimental nuclear reactor of the French Atomic Energy Commission. It is located at the Cadarache Research Centre in southern France and it is designed to act as a support to the French nuclear infrastructure. The purpose of the new testing programme termed, 'CABRI International Programme' (CIP) is to study the behaviour of PWR-type fuel rods at high burnup, equipped with an 'advanced' cladding, under Reactivity Initiated Accident (RIA) conditions (such as the scenario of a control rod ejection). Within the framework of this programme, piloted and funded by the French Institute of Nuclear Radioprotection and Safety (IRSN), ten tests are to be conducted with a frequency of two tests per year. The LPRE laboratory of the CEA which is in charge of the Preparation, realisation and breakdown of the test results studies the possibility to set up a new test analysis based on the processing of signals coming from sensors placed within the test equipment. During the experimental phase, the behaviour of the fuel element generates acoustic waves which can be detected by two microphones placed upstream and downstream of the test device. Studies showed the interest to realize temporal and spectral analyses on these signals by showing the existence of signatures which can be correlated with physical phenomena as the rod failure or the test shutdown (i.e. scram). The work presented in this article results from the will to consolidate these studies. Since the main phenomenon to be tracked is the fuel rod failure, the aim would be to highlight specific events which would have been precursors of the rod failure in order to use in the future these signals for further interpretation. Such an antecedent works resumption leads to a better understanding of the experimental needs and constitutes a good initial state to prepare the new very fast digital data acquisition systems. Although all the raw data are accessible in the form of text files, analyses and graphics representations were not straightforward to reproduce from the ancient studies since that, on one hand, people who were in charge of the original work left the laboratory and on the other hand because it is not easy when the time passes, even with our own work, to be able to remember the steps of data manipulations and the exact setup: - During the ancient experiments the use of analog data acquisition systems required to digitize tapes to be able to realize computer treatments. That had had for consequence to lose the initial dating. This one must be correctly edited to do temporal comparisons. - Analyses require functions for calculations whose parameters has to be well-known to reach the same results. We thus wished to manage our workflow in the idea that it can be easily reproducible on all the experiments. The object of the work presented in this article was to put in practice this strong bind between the data, treatments and generation of the document in order not to hesitate to do the iteration principle in action. We do not have to be afraid by the data driven analyses. According to the philosophy of the literate programming, the text of the technical document is woven with the computer code that produces all the printed output as tables, graphs for the study eliminating hence the unrealistic cut and paste. This difficulty is not specific to the nuclear domain. For many years, researchers have been worked out solutions to this mundane issue. And, presently, new technologies and high-level programming languages offer us actual answers. We will firstly present the tools applied in our laboratory to implement this workflow, then we will describe the global perception carried out to continue the study of the Acoustic Emission signals recorded by the two microphones during the fourteen last CABRI R.I.A. test.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Forward fitting of experimental data from a NE213 neutron detector installed with the magnetic proton recoil upgraded spectrometer at JET

In this paper, we present the results obtained from the data analysis of neutron spectra measured with a NE213 liquid scintillator at JET. We calculated the neutron response matrix of the instrument combining MCNPX simulations, a generic proton light output function measured with another detector and the fit of data from ohmic pulses. For the analysis, we selected a set of pulses with neutral beam injection heating (NBI) only and we applied a forward fitting procedure of modeled spectral components to extract the fraction of thermal neutron emission. The results showed the same trend of the ones obtained with the dedicated spectrometer TOFOR, even though the values from the NE213 analysis were systematically higher. This discrepancy is probably due to the different lines of sight of the two spectrometers (tangential for the NE213, vertical for TOFOR). The uncertainties on the thermal fraction estimates were from 4 to 7 times higher than the ones from the TOFOR analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Monte Carlo study of dilute neutron matter at finite temperatures

We report results of fully nonperturbative, path integral Monte Carlo calculations for dilute neutron matter. The neutron-neutron interaction in the s channel is parameterized by the scattering length and the effective range. We calculate the energy and the chemical potential as a function of temperature at density {rho}=0.003 fm{sup -3}. The critical temperature T{sub c} for the superfluid-normal phase transition is estimated from the finite size scaling of the condensate fraction. At low temperatures we extract the spectral weight function A(p,{omega}) from the imaginary time propagator using the methods of maximum entropy and singular value decomposition. We determine the quasiparticle spectrum, which can be accurately parameterized by three parameters: an effective mass m{sup *}, a mean-field potential U, and a gap {Delta}. Large values of {Delta}/T{sub c} indicate that the system is not a BCS-type superfluid at low temperatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lead Slowing-Down Spectrometry Time Spectral Analysis for Spent Fuel Assay: FY11 Status Report

Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) from next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration, of which PNNL is a part, to study the feasibility of Lead Slowing Down Spectroscopy (LSDS). This technique is an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today's confirmatory assay methods. This document is a progress report for FY2011 PNNL analysis and algorithm development. Progress made by PNNL in FY2011 continues to indicate the promise of LSDS analysis and algorithms applied to used fuel. PNNL developed an empirical model based on calibration of the LSDS to responses generated from well-characterized used fuel. The empirical model, which accounts for self-shielding effects using empirical basis vectors calculated from the singular value decomposition (SVD) of a matrix containing the true self-shielding functions of the used fuel assembly models. The potential for the direct and independent assay of the sum of the masses of 239Pu and 241Pu to within approximately 3% over a wide used fuel parameter space was demonstrated. Also, in FY2011, PNNL continued to develop an analytical model. Such efforts included the addition of six more non-fissile absorbers in the analytical shielding function and the non-uniformity of the neutron flux across the LSDS assay chamber. A hybrid analytical-empirical approach was developed to determine the mass of total Pu (sum of the masses of 239Pu, 240Pu, and 241Pu), which is an important quantity in safeguards. Results using this hybrid method were of approximately the same accuracy as the pure empirical approach. In addition, total Pu with much better accuracy with the hybrid approach than the pure analytical approach. In FY2012, PNNL will continue efforts to optimize its empirical model and minimize its reliance on calibration data. In addition, PNNL will continue to develop an analytical model, considering effects such as neutron-scattering in the fuel and cladding, as well as neutrons streaming through gaps between fuel pins in the fuel assembly.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparative DFT Computational Studies with Experimental Investigations for Novel Synthesized Fluorescent Pyrazoline Derivatives

A novel series of pyrazoline derivatives were synthesized and their spectral properties were characterized via FT-IR, {sup 1}H, and {sup 13}C NMR. The electronic transitions and fluorescence properties were tracked via UV-Vis and emission spectrometry. The density functional theory (DFT) calculations have been also computed to get spot onto the geometry, electronic transitions and spectroscopic properties theoretically that has been compared with the encountered experimental ones. Moreover, the dipole moment, optimized energy, HOMO - LUMO energies and band gaps were calculated for novel candidates pyrazoline derivatives with highly fluorescence quantum yield.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ground electronic state description of thiourea coordination in homoleptic Zn 2+ , Ni 2+ and Co 2+ complexes using sulfur K -edge X-ray absorption spectroscopy

Sulfur K-edge X-ray absorption spectroscopy (XAS) was employed to experimentally characterize the coordinative bond between the thiourea (TU) or thiocarbamide ligand and transition metal (TM) ions Zn 2+ , Co 2+ and Ni 2+ in distorted tetrahedral and octahedral homoleptic coordination environments. Comparisons of XAS spectra of the free TU ligand and [Zn(TU) 4 ] 2+ , [Co(TU) 4 ] 2+ and [Ni(TU) 6 ] 2+ complexes clearly identify spectral features unique to TM 2+ –S(TU) bonding. Quantitative analysis of pre-edge intensities describes the covalency of Ni 2+ —S(TU) and Co 2+ —S(TU) bonding to be at most 21% and 9% as expressed by the S 3p contributions per TM 3d electron hole. Using relevant Ni 2+ complexes with dithiocarbamate and thioether ligands, we evaluated the empirical S 1s → 3p transition dipole integrals developed for S-donor ligands and their dependence on heteroatom substitutions. With the aid of density functional theory-based ground electronic state calculations, we found evidence for the need of using a transition dipole that is dependent on the presence of conjugated heteroatom (N) substitution in these S-donor ligands.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Investigating the effect of characteristic x-rays in cadmium zinc telluride detectors under breast computerized tomography operating conditions

A number of research groups have been investigating the use of dedicated breast computerized tomography (CT). Preliminary results have been encouraging, suggesting an improved visualization of masses on breast CT as compared to conventional mammography. Nonetheless, there are many challenges to overcome before breast CT can become a routine clinical reality. One potential improvement over current breast CT prototypes would be the use of photon counting detectors with cadmium zinc telluride (CZT) (or CdTe) semiconductor material. These detectors can operate at room temperature and provide high detection efficiency and the capability of multi-energy imaging; however, one factor in particular that limits image quality is the emission of characteristic x-rays. In this study, the degradative effects of characteristic x-rays are examined when using a CZT detector under breast CT operating conditions. Monte Carlo simulation software was used to evaluate the effect of characteristic x-rays and the detector element size on spatial and spectral resolution for a CZT detector used under breast CT operating conditions. In particular, lower kVp spectra and thinner CZT thicknesses were studied than that typically used with CZT based conventional CT detectors. In addition, the effect of characteristic x-rays on the accuracy of material decomposition in spectral CT imaging was explored. It was observed that when imaging with 50-60 kVp spectra, the x-ray transmission through CZT was very low for all detector thicknesses studied (0.5–3.0 mm), thus retaining dose efficiency. As expected, characteristic x-ray escape from the detector element of x-ray interaction increased with decreasing detector element size, approaching a 50% escape fraction for a 100 μm size detector element. The detector point spread function was observed to have only minor degradation with detector element size greater than 200 μm and lower kV settings. Characteristic x-rays produced increasing distortion in the spectral response with decreasing detector element size. If not corrected for, this caused a large bias in estimating tissue density parameters for material decomposition. It was also observed that degradation of the spectral response due to characteristic x-rays caused worsening precision in the estimation of tissue density parameters. It was observed that characteristic x-rays do cause some degradation in the spatial and spectral resolution of thin CZT detectors operating under breast CT conditions. These degradations should be manageable with careful selection of the detector element size. Even with the observed spectral distortion from characteristic x-rays, it is still possible to correctly estimate tissue parameters for material decomposition using spectral CT if accurate modeling is used.

36 MATERIALS SCIENCE↗

( d , n ) proton-transfer reactions on Be 9 , B 11 , C 13 , N 14 , 15 , and F 19 and spectroscopic factors at E d = 16 MeV

The (d,n) reaction has been studied with targets of 9 Be, 11 B, 13 C, 14,15 N, and 19F at E d = 16MeV using a deuterated liquid-scintillator array. Advanced spectral unfolding techniques with accurately measured scintillator response functions were employed to extract neutron energy spectra without the need for long-path neutron time-of-flight. An analysis of the proton-transfer data at forward angles to the ground states of the final nuclei, using finite-range distorted-wave Born approximation analysis with common bound-state, global, and local optical-model parameter sets, yields a set of self-consistent spectroscopic factors. These are compared with the results of several previous time-of-flight measurements, most done many years ago for individual nuclei at lower energy and often analyzed using zero-range transfer codes. In contrast to some of the earlier published data, our data generally compare well with simple shell-model predictions, with little evidence for uniform quenching (reduction from shell-model values) that has previously been reported from analysis of nucleon knock-out reactions. Data for low-lying excited states in 14 N from 13 C(d,n) also is analyzed and spectroscopic information relevant to nuclear astrophysics obtained. Here, a preliminary study of the radioactive ion beam induced reaction 7 Be(d,n), E( 7 Be) = 30MeV was carried out and indicates further improvements are needed for such measurements, which require detection of neutrons with E n < 2MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absolute calibration of optical streak cameras on picosecond time scales using supercontinuum generation

Here we report a new method using high stability, laser-driven supercontinuum generation in a liquid cell to calibrate the absolute photon response of fast optical streak cameras as a function of wavelength when operating at fastest sweep speeds. A stable, pulsed white light source based around the use of self-phase modulation in a salt solution was developed to provide the required brightness on picosecond timescales, enabling streak camera calibration in fully dynamic operation. The measured spectral brightness allowed for absolute photon response calibration over a broad spectral range (425-650nm). Calibrations performed with two Axis Photonique streak cameras using the Photonis P820PSU streak tube demonstrated responses which qualitatively follow the photocathode response. Peak sensitivities were 1 photon/count above background. The absolute dynamic sensitivity is less than the static by up to an order of magnitude. We attribute this to the dynamic response of the phosphor being lower.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurements of D{sub α} spectrum produced by anisotropic fast ions in the gas dynamic trap

Angled injection of eight deuterium beams in gas dynamic trap (GDT) plasmas builds up the population of fast ions with the distribution function, which conserves a high degree of initial anisotropy in space, energy, and pitch angle. Unlike the Maxwellian distribution case, the fast ion plasma component in GDT cannot be exhaustively characterized by the temperature and density. The instrumentation complex to study of fast ions is comprised of motional Stark effect diagnostic, analyzers of charge exchange atoms, and others. The set of numerical codes using for equilibrium modeling is also an important tool of analysis. In the recent campaign of summer 2014, we recorded first signals from the new fast ion D-alpha diagnostic on GDT. This paper presents the diagnostic description and results of pilot measurements. The diagnostic has four lines of sight, distributed across the radius of an axially symmetric plasma column in GDT. In the present setup, a line-integrated optical signal is measured in each channel. In the transverse direction, the spatial resolution is 18 mm. Collected light comes to the grating spectrometer with the low-noise detector based on a charge-coupled device matrix. In the regime of four spectra stacked vertically on the sensor, the effective spectral resolution of measurements is approximately 0.015 nm. Exposure timing is provided by the fast optical ferroelectric crystal shutter, allowing frames of duration down to 70 μs. This number represents the time resolution of measurements. A large dynamic range of the camera permits for a measurement of relatively small light signals produced by fast ions on top of the bright background emission from the bulk plasma. The fast ion emission has a non-Gaussian spectrum featuring the characteristic width of approximately 4 nm, which can be separated from relatively narrow Gaussian lines of D-alpha and H-alpha coming from the plasma periphery, and diagnostic beam emission. The signal to noise ratio varies from approximately ten for the central channel to approximately five for the outermost channel. We used the special set of Monte Carlo codes to fit the measured spectra. The shape of model fit shows a good agreement with the experimental fast ion D-alpha spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Soil Properties and Input Motion on Site Amplification Using Validated Nonlinear Soil Model

Here, three-dimensional (3-D) nonlinear site response analyses are conducted using finite element models of actual soil profiles from ten nuclear power plant (NPP) sites in the United States to investigate the effects of soil properties and input motions on site amplification. The modeling approach developed in this study combines several novel elements, such as 3-D analysis (including vertical motions), nonlinear inelastic behavior of soil (strain-dependent shear modulus reduction and hysteretic damping), formulation of nonreflecting boundary conditions at the base, and generation of realistic outcrop ground motions for specific sites. All these elements of the modeling approach are first validated using actual data from five earthquakes at three downhole array stations recorded in the Kiban-Kyoshin network (KiK-net), Japan. The same approach is then used to develop site models of ten NPP sites in the United States and corresponding ground motions that are spectrally matched to the site hazard spectra. Eight sets of three-component input motions are used in the study and are categorized on the basis of presence or absence of a near-field pulse in the seed ground motions used for spectral matching. It is found that all sites retain a definite site amplification function regardless of the input motion, provided that the seed motion is spectrally matched to the site hazard spectra. The magnitude of site amplification and frequencies at which they occur depend upon soil properties, particularly the shear wave velocity profile and the constitutive relationship (strain-dependent shear modulus reduction and hysteretic damping) of soil. Amplification of spectral acceleration in the vertical direction (up-down motion) is found to be just as much as, if not more than, the amplification in the horizontal direction. Peak shear strain is found to be about 20% larger for near-field motions compared to far-field motions whereas maximum horizontal site amplification for far-field motions is found to be consistently larger than that of near-field motions, even though the differences between the two remain within the scatter resulting from individual ground motions.

99 GENERAL AND MISCELLANEOUS↗

Nucleon form factors in dispersively improved chiral effective field theory: Scalar form factor

We propose a method for calculating the nucleon form factors (FFs) of $G$-parity-even operators by combining Chiral Effective Field Theory ($\chi$EFT) and dispersion analysis. The FFs are expressed as dispersive integrals over the two-pion cut at $t > 4 M_\pi^2$. The spectral functions are obtained from the elastic unitarity condition and expressed as products of the complex $\pi\pi \rightarrow N\bar N$ partial-wave amplitudes and the timelike pion FF. $\chi$EFT is used to calculate the ratio of the partial-wave amplitudes and the pion FF, which is real and free of $\pi\pi$ rescattering in the $t$-channel ($N/D$ method). The rescattering effects are then incorporated by multiplying with the squared modulus of the empirical pion FF. The procedure results in a marked improvement compared to conventional $\chi$EFT calculations of the spectral functions. We apply the method to the nucleon scalar FF and compute the scalar spectral function, the scalar radius, the $t$-dependent FF, and the Cheng-Dashen discrepancy. Higher-order chiral corrections are estimated through the $\pi N$ low-energy constants. Results are in excellent agreement with dispersion-theoretical calculations. We elaborate several other interesting aspects of our method. The results show proper scaling behavior in the large-$N_c$ limit of QCD because the $\chi$EFT includes $N$ and $\Delta$ intermediate states. The squared modulus of the timelike pion FF required by our method can be extracted from Lattice QCD calculations of vacuum correlation functions of the operator at large Euclidean distances. Our method can be applied to the nucleon FFs of other operators of interest, such as the isovector-vector current, the energy-momentum tensor, and twist-2 QCD operators (moments of generalized parton distributions).

1=Nc expansion↗

The Quest for the Ultimate Anisotropic Banach Space

We present a new scale U{sub p}{sup t,s} (s<−t<0 and 1≤p<∞) of anisotropic Banach spaces, defined via Paley–Littlewood, on which the transfer operator L{sub g}φ=(g⋅φ)∘T{sup −1} associated to a hyperbolic dynamical system T has good spectral properties. When p=1 and t is an integer, the spaces are analogous to the “geometric” spaces B{sup t,|s+t|} considered by Gouëzel and Liverani (Ergod Theory Dyn Syst 26:189–217, 2006). When p>1 and −1+1/p<s<−t<0<t<1/p, the spaces are somewhat analogous to the geometric spaces considered by Demers and Liverani (Trans Am Math Soc 360:4777–4814, 2008). In addition, just like for the “microlocal” spaces defined by Baladi and Tsujii (Ann Inst Fourier 57:127–154, 2007) (or Faure–Roy–Sjöstrand in Open Math J 1:35–81, 2008), the transfer operator acting on U{sub p}{sup t,s} can be decomposed into L{sub g,b}+L{sub g,c}, where L{sub g,b} has a controlled norm while a suitable power of L{sub g,c} is nuclear. This “nuclear power decomposition” enhances the Lasota–Yorke bounds and makes the spaces U{sub p}{sup t,s} amenable to the kneading approach of Milnor–Thurson (Dynamical Systems (Maryland 1986–1987), Springer, Berlin, 1988) (as revisited by Baladi–Ruelle, Baladi in Dynamical Zeta Functions and Dynamical Determinants for Hyperbolic Maps, Monograph, 2016; Baladi and Ruelle in Ergod Theory Dyn Syst 14:621–632, 1994; Baladi and Ruelle in Invent Math 123:553–574, 1996) to study dynamical determinants and zeta functions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ML-Based Pebble Power Reconstruction for Pebble Bed Reactor Analysis

Pebble power reconstruction has been explored to complement the conventional homogenized modeling approach in pebble bed reactor (PBR) analysis, as detailed heterogeneous geometry calculations are computationally expensive. The random distribution of pebble fuels within the core challenges the application of conventional pin power reconstruction methods. To address this, we introduce a machine learning approach based on the transformer model, composed of encoder and decoder layers, to estimate the flux and power form functions for reconstructing individual pebble neutron fluxes and powers. The homogeneous neutron flux distribution within each spectral zone (SZ) is obtained from finite element solutions of global diffusion or transport calculations. Verification tests demonstrate that the trained transformer model accurately predicts power form functions over a range of conditions, including variations in pebble enrichment, location, type, SZ size, and burnup. In particular, verification using a three-dimensional PBR benchmark with burned pebbles shows good agreement in heterogeneous pebble power distributions between Griffin and Serpent. These results highlight the potential of applying conventional pin power reconstruction approaches to PBR cores with randomly distributed pebbles.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High resolution absorption spectroscopy of exploding wire plasmas using an x-pinch x-ray source and spherically bent crystal

We present here the use of absorption spectroscopy of the continuum radiation from x-pinch-produced point x-ray sources as a diagnostic to investigate the properties of aluminum plasmas created by pulsed power machines. This technique is being developed to determine the charge state, temperature, and density as a function of time and space under conditions that are inaccessible to x-ray emission spectroscopic diagnostics. The apparatus and its characterization are described, and the spectrometer dispersion, magnification, and resolution are calculated and compared with experimental results. Spectral resolution of about 5000 and spatial resolution of about 20 {mu}m are demonstrated. This spectral resolution is the highest available to date in an absorption experiment. The beneficial properties of the x-pinch x-ray source as the backlighter for this diagnostic are the small source size (<5 {mu}m), smooth continuum radiation, and short pulse duration (<0.1 ns). Results from a closely spaced (1 mm) exploding wire pair are shown and the general features are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗