Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Piezo-Operated Shutter Mechanism Moves 1.5 cm

The figure shows parts of a shutter mechanism designed to satisfy a number of requirements specific to its original intended application as a component of an atomic clock to be flown in outer space. The mechanism may also be suitable for use in laboratory and industrial vacuum systems on Earth for which there are similar requirements. The requirements include the following: a) To alternately close, then open, a 1.5-cm-diameter optical aperture twice per second, with a stroke time of no more than 15 ms, during a total operational lifetime of at least a year; b) To attenuate light by a factor of at least 1012 when in the closed position; c) To generate little or no magnetic field; d) To be capable of withstanding bakeout at a temperature of 200 C to minimize outgassing during subsequent operation in an ultrahigh vacuum; and e) To fit within a diameter of 12 in. (=305 mm) a size limit dictated by the size of an associated magnetic shield. The light-attenuation requirement is satisfied by use of overlapping shutter blades. The closure of the aperture involves, among other things, insertion of a single shutter blade between a pair of shutter blades. The requirement to minimize the magnetic field is satisfied by use of piezoelectric actuators. Because piezoelectric actuators cannot withstand bakeout, they must be mounted outside the vacuum chamber, and, hence, motion must be transmitted from the actuators to the shutter levers via a vacuum-chamber-wall diaphragm.

Glaser, Robert↗

Skin Dosimetry in Breast Teletherapy on a Phantom Anthropomorphic and Anthropometric Phantom

This paper addresses the breast teletherapy dosimetry. The goal is to evaluate and compare absorbed doses in equivalent skin tissue, TE-skin, of an anthropomorphic and anthropometric breast phantom submitted to breast radiotherapy. The methodology involved the reproduction of a set of tomographic images of the phantom; the elaboration of conformational radiotherapy planning in the SOMAVISION and CadPlan (TPS) software; and the synthetic breast irradiation by parallel opposed fields in 3D conformal teletherapy at 6 MV linear accelerator Clinac-2100 C from VARIAN with prescribed dose (PD) of 180 cGy to the target volume (PTV), referent to the glandular tissue. Radiochromic films EBT2 were selected as dosimeters. Two independent calibration processes of films with solid water Gammex 457 plates and water filled box were produced. Curves of optical density (OD) versus absorbed dose were produced. Dosimeters were positioned in the external region of the breast phantom in contact with TE-skin, area of 4.0 cm{sup 2} each. The irradiation process was prepared in duplicate to check the reproducibility of the technique. The radiochromic films were scanned and their response in RGB (Red, Green, Blue) analyzed by the ImageJ software. The optical density was obtained and converted to dose based on the calibration curves. Thus, the spatial dose distribution in the skin was reproduced. The absorbed doses measured on the radiochromic films in TE-skin showed values between upper and lower quadrants at 9 o'clock in the range of 54% of PD, between the upper and lower quadrants 3 o'clock in the range of 72% and 6 o'clock at the lower quadrant in the range of 68 % of PD. The values are ±64% (p <0.05) according to the TPS. It is concluded that the depth dose measured in solid water plates or water box reproduce equivalent dose values for both calibration processes of the radiochromic films. It was observed that the skin received doses ranging from 50% to 78% of the prescribed dose after two parallel opposed irradiation fields. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Real-time Optical Network for Accelerator Control

The timing requirements of a modern accelerator complex call for several features. The first is a system for high precision relative timing among accelerator components. Stabilized fiber links have already been demonstrated to achieve sub-10 femtoseconds relative timing precision. The second is a system for timing distribution of absolute time with sufficient precision to identify a specific RF bucket. The White Rabbit technology is a promising candidate to deliver the absolute time that is linked to the GPS clock. In this study we demonstrated that these two technologies can be combined in a way that the absolute time information can be delivered to the stabilized fiber link system. This was accomplished by researching the design of the stabilized fiber and White Rabbit systems and devising adaptation modules that facilitate co-existence of both systems in the same FPGA environment. We built a prototype system using off-the-shelf products and implemented a proof-of-concept version of the FPGA firmware. The test verified that the White Rabbit features operate correctly under the stabilized fiber system environment. This work demonstrates that turn-key femtosecond timing systems with absolute time information can be built cost effectively and deployed in various accelerator environments. This will lead to many new applications in chemistry, biology and surface dynamics, to name a few.

43 PARTICLE ACCELERATORS↗

Direct-detection Free-space Laser Transceiver Test-bed

NASA Goddard Space Flight Center is developing a direct-detection free-space laser communications transceiver test bed. The laser transmitter is a master-oscillator power amplifier (MOPA) configuration using a 1060 nm wavelength laser-diode with a two-stage multi-watt Ytterbium fiber amplifier. Dual Mach-Zehnder electro-optic modulators provide an extinction ratio greater than 40 dB. The MOPA design delivered 10-W average power with low-duty-cycle PPM waveforms and achieved 1.7 kW peak power. We use pulse-position modulation format with a pseudo-noise code header to assist clock recovery and frame boundary identification. We are examining the use of low-density-parity-check (LDPC) codes for forward error correction. Our receiver uses an InGaAsP 1 mm diameter photocathode hybrid photomultiplier tube (HPMT) cooled with a thermo-electric cooler. The HPMT has 25% single-photon detection efficiency at 1064 nm wavelength with a dark count rate of 60,000/s at -22 degrees Celsius and a single-photon impulse response of 0.9 ns. We report on progress toward demonstrating a combined laser communications and ranging field experiment.

Krainak, Michael A.↗

High speed radiation tolerant data links

This project was slated to design and develop Rad-Hard IP components for 1Gb/s links and supporting hardware designs such as PLL, SER/DES, pad drivers and receivers and custom protocol hardware for the 1Gb/s channel. Also included in the proposal was a study of a hardened memory to be used as a packet buffer for channel and data concentrator components to meet the 1 Gb/s specification. Over the course of the proposal, technology change and innovation of hardware designs lead us away from the 1 Gb/s goal to contemplate much higher performance link IP which, we believed better met the goals of physics experiments. Note that CERN microelectronics had managed to create a 4.7 Gb/s link designed to drive optical fibers and containing infrastructure for connecting much lower bandwidth front-end devices. Our own work to that point had shown the possibility of constructing a link with much lower power, lower physical overhead but of equivalent performance that could be designed to integrate directly onto the front-end ASIC (ADC and data encoding) designs. Substantial overall power savings and experimental simplicity could be achieved by eliminating data transmission to data concentrators and data concentrators and related hardened buffering themselves, with conversion to optical media at a removed distance from the experiment core. We had already developed and tested Rad-Hard SER/DES components (1Gb in 130nm standard cells) and redundant Pad Drivers/Receivers (3+ Gb/s designed and measured performance), and had a viable 1Gb/s link design based on redundant a stuttered clock receiver and classical PLL, so the basic goals of the proposal had been achieved. Below, in chronological order, are the products and tools we constructed, as well as our tests and publications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

50 Mbps free space direct detection laser diode optical communication system with Q = 4 PPM signaling

A 50 Mbps direct detection optical communication system for use in an intersatellite link was constructed with an AlGaAs laser diode transmitter and a silicon avalanche photodiode photodetector. The system used a Q = 4 PPM format. The receiver consisted of a maximum likelihood PPM detector and a timing recovery subsystem. The PPM slot clock was recovered at the receiver by using a transition detector followed by a PLL. The PPM word clock was recovered by using a second PLL whose input was derived from the presence of back-to-back PPM pulses contained in the received random PPM pulse sequences. The system achieved a bit error rate of 0.000001 at less than 50 detected signal photons/information bit. The receiver was capable of acquiring and maintaining slot and word synchronization for received signal levels greater than 20 photons/information bit, at which the receiver bit error rate was about 0.01.

Sun, Xiaoli↗

Dosimetry characterization of a multibeam radiotherapy treatment for age-related macular degeneration

Age-related macular degeneration (ARMD) is a major health problem worldwide. Advanced ARMD, which ultimately leads to profound vision loss, has dry and wet forms, which account for 20% and 80% of cases involving severe vision loss, respectively. A new device and approach for radiation treatment of ARMD has been recently developed by Oraya Therapeutics, Inc. (Newark, CA). The goal of the present study is to provide a initial dosimetry characterization of the proposed radiotherapy treatment via Monte Carlo radiation transport simulation. A 3D eye model including cornea, anterior chamber, lens, orbit, fat, sclera, choroid, retina, vitreous, macula, and optic nerve was carefully designed. The eye model was imported into the MCNPX2.5 Monte Carlo code and radiation transport simulations were undertaken to obtain absorbed doses and dose volume histograms (DVH) to targeted and nontargeted structures within the eye. Three different studies were undertaken to investigate (1) available beam angles that maximized the dose to the macula target tissue, simultaneously minimizing dose to normal tissues, (2) the energy dependency of the DVH for different x-ray energies (80, 100, and 120 kVp), and (3) the optimal focal spot size among options of 0.0, 0.4, 1.0, and 5.5 mm. All results were scaled to give 8 Gy to the macula volume, which is the current treatment requirement. Eight beam treatment angles are currently under investigation. In all eight beam angles, the source-to-target distance is 13 cm, and the polar angle of entry is 30 degree sign from the geometric axis of the eye. The azimuthal angle changes in eight increments of 45 degree sign in a clockwise fashion, such that an azimuthal angle of 0 degree sign corresponds to the 12 o'clock position when viewing the treated eye. Based on considerations of nontarget tissue avoidance, as well as facial-anatomical restrictions on beam delivery, treatment azimuthal angles between 135 degree sign and 225 degree sign would be available for this treatment system (i.e., directly upward and entering the eye from below). At beam directions approaching 225 degree sign and higher, some dose contribution to the optic nerve would result under the assumption that the optic nerve is tilted cranially above the geometric axis in a given patient, a feature not typically seen in past studies. A total treatment dose of 24 Gy would be delivered in three 8 Gy treatments at these selected azimuthal angles. Dose coefficients, defined as the macula radiation absorbed dose per unit air kerma in units of Gy/Gy, were 16% higher for 120 kVp x-ray beams in comparison to those at 80 kVp, thus requiring only 86% of the integrated tube current (mAs) for equivalent dose delivery. When 0.0, 0.4, and 1.0 mm focal spot sizes were used, the dose profiles in the macula are very similar and relatively uniform, whereas a 5.5 mm focal spot size produced a more nonuniform dose profile. The results of this study demonstrate the therapeutic promise of this device and provide important information for further design and clinical implementation for radiotherapy treatments for ARMD.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation-Hard SpaceWire/Gigabit Ethernet-Compatible Transponder

A radiation-hard transponder was developed utilizing submicron/nanotechnology from IBM. The device consumes low power and has a low fabrication cost. This device utilizes a Plug-and-Play concept, and can be integrated into intra-satellite networks, supporting SpaceWire and Gigabit Ethernet I/O. A space-qualified, 100-pin package also was developed, allowing space-qualified (class K) transponders to be delivered within a six-month time frame. The novel, optical, radiation-tolerant transponder was implemented as a standalone board, containing the transponder ASIC (application specific integrated circuit) and optical module, with an FPGA (field-programmable gate array) friendly parallel interface. It features improved radiation tolerance; high-data-rate, low-power consumption; and advanced functionality. The transponder utilizes a patented current mode logic library of radiation-hardened-by-architecture cells. The transponder was developed, fabricated, and radhard tested up to 1 MRad. It was fabricated using 90-nm CMOS (complementary metal oxide semiconductor) 9 SF process from IBM, and incorporates full BIT circuitry, allowing a loop back test. The low-speed parallel LVCMOS (lowvoltage complementary metal oxide semiconductor) bus is compatible with Actel FPGA. The output LVDS (low-voltage differential signaling) interface operates up to 1.5 Gb/s. Built-in CDR (clock-data recovery) circuitry provides robust synchronization and incorporates two alarm signals such as synch loss and signal loss. The ultra-linear peak detector scheme allows on-line control of the amplitude of the input signal. Power consumption is less than 300 mW. The developed transponder with a 1.25 Gb/s serial data rate incorporates a 10-to-1 serializer with an internal clock multiplication unit and a 10-1 deserializer with internal clock and data recovery block, which can operate with 8B10B encoded signals. Three loop-back test modes are provided to facilitate the built-in-test functionality. The design is based on a proprietary library of differential current switching logic cells implemented in the standard 90-nm CMOS 9SF technology from IBM. The proprietary low-power LVDS physical interface is fully compatible with the SpaceWire standard, and can be directly connected to the SFP MSA (small form factor pluggable Multiple Source Agreement) optical transponder. The low-speed parallel interfaces are fully compatible with the standard 1.8 V CMOS input/output devices. The utilized proprietary annular CMOS layout structures provide TID tolerance above 1.2 MRad. The complete chip consumes less than 150 mW of power from a single 1.8-V positive supply source.

Katzman, Vladimir↗

Optical communication with semiconductor laser diodes

Slot timing recovery in a direct detection optical PPM communication system can be achieved by processing the photodetector waveform with a nonlinear device whose output forms the input to a phase lock group. The choice of a simple transition detector as the nonlinearity is shown to give satisfactory synchronization performance. The rms phase error of the recovered slot clock and the effect of slot timing jitter on the bit error probability were directly measured. The experimental system consisted of an AlGaAs laser diode (lambda = 834 nm) and a silicon avalanche photodiode (APD) photodetector and used Q=4 PPM signaling operated at a source data rate of 25 megabits/second. The mathematical model developed to characterize system performance is shown to be in good agreement with actual performance measurements. The use of the recovered slot clock in the receiver resulted in no degradation in receiver sensitivity compared to a system with perfect slot timing. The system achieved a bit error probability of 10 to the minus 6 power at received signal energies corresponding to an average of less than 60 detected photons per information bit.

Davidson, F.↗

Phase and Pupil Amplitude Recovery for JWST Space-Optics Control

This slide presentation reviews the phase and pupil amplitude recovery for the James Webb Space Telescope (JWST) Near Infrared Camera (NIRCam). It includes views of the Integrated Science Instrument Module (ISIM), the NIRCam, examples of Phase Retrieval Data, Ghost Irradiance, Pupil Amplitude Estimation, Amplitude Retrieval, Initial Plate Scale Estimation using the Modulation Transfer Function (MTF), Pupil Amplitude Estimation vs lambda, Pupil Amplitude Estimation vs. number of Images, Pupil Amplitude Estimation vs Rotation (clocking), and Typical Phase Retrieval Results Also included is information about the phase retrieval approach, Non-Linear Optimization (NLO) Optimized Diversity Functions, and Least Square Error vs. Starting Pupil Amplitude.

Dean, B. H.↗

NASA Tech Briefs, October 2013

Topics include: A Short-Range Distance Sensor with Exceptional Linearity; Miniature Trace Gas Detector Based on Microfabricated Optical Resonators; Commercial Non-Dispersive Infrared Spectroscopy Sensors for Sub-Ambient Carbon Dioxide Detection; Fast, Large-Area, Wide-Bandgap UV Photodetector for Cherenkov Light Detection; Mission Data System Java Edition Version 7; Adaptive Distributed Environment for Procedure Training (ADEPT); LEGEND, a LEO-to-GEO Environment Debris Model; Electronics/Computers; Millimeter-Wave Localizers for Aircraft-to-Aircraft Approach Navigation; Impedance Discontinuity Reduction Between High-Speed Differential Connectors and PCB Interfaces; SpaceCube Version 1.5; High-Pressure Lightweight Thrusters; Non-Magnetic, Tough, Corrosion- and Wear-Resistant Knives From Bulk Metallic Glasses and Composites; Ambient Dried Aerogels; Applications for Gradient Metal Alloys Fabricated Using Additive Manufacturing; Passivation of Flexible YBCO Superconducting Current Lead With Amorphous SiO2 Layer; Propellant-Flow-Actuated Rocket Engine Igniter; Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads; Method to Increase Performance of Foil Bearings Through Passive Thermal Management; Unibody Composite Pressurized Structure; JWST Integrated Science Instrument Module Alignment Optimization Tool; Radar Range Sidelobe Reduction Using Adaptive Pulse Compression Technique; Digitally Calibrated TR Modules Enabling Real-Time Beamforming SweepSAR Architectures; Electro-Optic Time-to-Space Converter for Optical Detector Jitter Mitigation; Partially Transparent Petaled Mask/Occulter for Visible-Range Spectrum; Educational NASA Computational and Scientific Studies (enCOMPASS); Coarse-Grain Bandwidth Estimation Scheme for Large-Scale Network; Detection of Moving Targets Using Soliton Resonance Effect; High-Efficiency Nested Hall Thrusters for Robotic Solar System Exploration; High-Voltage Clock Driver for Photon-Counting CCD Characterization; Development of the Code RITRACKS; and Enabling Microliquid Chromatography by Microbead Packing of Microchannels.

Source record↗

Research on techniques for laser ranging to optical corner reflectors on the moon. Research on laser techniques and single photo-electron detection and timing

Experimental studies using a pulsed LED, Cerenkov source, and a 100 ps laser were made of various photomultipliers and discriminator combinations. In addition, a new type of neodymium-YAG frequency doubled laser was used as the basis for the development of a stable, short pulse, high repetition rate laser system. This laser was then used in conjunction with atomic clocks to study the effect of gravitational potential on elapsed time. Avenues to promote the development of international cooperation in the area of lunar laser ranging were also explored.

Alley, C. O.↗

Provably secure time distribution for the electric grid

We demonstrate a quantum time distribution (QTD) method that combines the precision of optical timing techniques with the integrity of quantum key distribution (QKD). Critical infrastructure is dependent on microprocessor- and programmable logic-based monitoring and control systems. The distribution of timing information across the electric grid is accomplished by GPS signals which are known to be vulnerable to spoofing. We demonstrate a method for synchronizing remote clocks based on the arrival time of photons in a modifed QKD system. This has the advantage that the signal can be veried by examining the quantum states of the photons similar to QKD.

Smith, IV, Amos M↗

Extreme nonlinear response of ultranarrow optical transitions in cavity QED for laser stabilization

We explore the potential of direct spectroscopy of ultranarrow optical transitions of atoms localized in an optical cavity. In contrast to stabilization against a reference cavity, which is the approach currently used for the most highly stabilized lasers, stabilization against an atomic transition does not suffer from Brownian thermal noise. Spectroscopy of ultranarrow optical transitions in a cavity operates in a very highly saturated regime in which nonlinear effects such as bistability play an important role. From the universal behavior of the Jaynes-Cummings model with dissipation, we derive the fundamental limits for laser stabilization using direct spectroscopy of ultranarrow atomic lines. We find that, with current lattice clock experiments, laser linewidths of about 1 mHz can be achieved in principle, and the ultimate limitations of this technique are at the 1 {mu}Hz level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A novel photonic oscillator

We report a novel oscillator for photonic RF systems. This oscillator is capable of generating high-frequency signals up to 70 GHz in both electrical and optical domains and is a special voltage-controlled oscillator with an optical output port. It can be used to make a phase-locked loop (PLL) and perform all functions that a PLL is capable of for photonic systems. It can be synchronized to a reference source by means of optical injection locking, electrical injection locking, and PLL. It can also be self-phase locked and self-injection locked to generate a high-stability photonic RF reference. Its applications include high-frequency reference regeneration and distribution, high-gain frequency multiplication, comb-frequecy and square-wave generation, carrier recovery, and clock recovery. We anticipate that such photonic voltage-controlled oscillators (VCOs) will be as important to photonic RF systems as electrical VCOs are to electrical RF systems.

Yao, X. S.↗

A 250 MHz Level 1 Trigger and Distribution System for the GlueX experiment

The GlueX detector now under construction at Jefferson Lab will search for exotic mesons though photoproduction (10^8 tagged photons per second) on a liquid hydrogen target. A Level 1 hardware trigger design is being developed to reduce total electromagnetic (>200 MHz) and hadronic (>350 kHz) rates to less than 200 kHz. This trigger is dead timeless and operates on a global synchronized 250 MHz clock. The core of the trigger design is based on a custom pipelined flash ADC board that uses a VXS backplane to collect samples from all ADCs in a VME crate. A custom switch-slot board called a Crate Trigger Processor (CTP) processes this data and passes the crate level data via a multi-lane fiber optic link to the Global Trigger Processing Crate (also VXS). Within this crate detector sub-system processor (SSP) boards can accept all individual crate links. The subsystem data are processed and finally passed to global trigger boards (GTP) where the final L1 decision is made. We present details of the trigger design and report some performance results on current prototype systems.

42 ENGINEERING↗

Progress of the LASSO experiment

The LASSO (Later Synchronisation from Stationary Orbit) experiment, designed to demonstrate the feasibility of achieving time synchronization between remote atomic clocks with an accuracy of one nanosecond or better by using laser techniques for the first time is described. The experiment uses groundbased laser stations and the SIRIO-2 geostationary satellite to be launched towards the end of 1981. The qualification of the LASSO on-board equipment is discussed with a brief description of the electrical and optical test equipment used. The progress of the operational organization is included.

Serene, B. E. H.↗

An Updated Model for the Effect of Atmospheric Absorption on Sounding Rockets

A very high-resolution R > 20,000 Far Ultraviolet full-disk, solar spectrograph will be launched in the Spring of 2023. This paper describes the in-flight wavelength calibration techniques and the fortuitous retrieval of Earth’s thermospheric information during the flight. Building and calibration of the Full-sun Ultraviolet Rocket Spectrograph (FURST) is currently underway. The purpose of this instrument is to obtain the highest resolution and most complete Far Ultra-Violet (FUV) spectra of the full disk Sun. This so-called "Sun-as-a-star" spectra will allow direct comparisons between our Sun and other stars measured by the Hubble Space Telescope(HST) and the upcoming James Webb Space Telescope (JWST). The Solar Physics groups at NASA Marshall Space Flight Center (MSFC) and Montana State University (MSU) have been developing the tools and procedures necessary to achieve the high spectral resolution goal. These include, among other things, improved tracking of error propagation, in-situ monitoring of the camera gain with a radioactive Fe-55 source, and the development of a simulated spectral calibration map under a noisy diagnostic-lamp signal. This mapping introduces a clocked CCD in order to obtain sub-pixel spectral resolution and overcome the Nyquist limit by about a factor of 2. Aside from the main purpose of FURST, we have been investigating the effect of absorption in the upper atmosphere at sounding-rocket altitudes (about 100-300 km). We present here an improved model of the optical depth caused by the thermospheric Oxygen cross-section and H and O self-absorption. This data-based model uses concentric spherical shells to account for the curvature of the Earth’s atmosphere and refraction. Using these calculations, we present the anticipated effect on the signal received by FURST, how that signal changes over the course of the flight-path These absorption peaks would provide wavelength fiducials at line-center that might add to in-flight calibration of the instrument. Many studies have found ways to correct for these so-called "Telluric" lines. However, it may be that these lines can in fact be a useful tool to further improve our calibration, rather than simply a nuisance to be corrected for! Finally, we discuss the inversion problem: how we could take actual flight data and back-out the atmospheric data (such as density and temperature) from any such sounding rocket flight that shows evidence of atmospheric absorption.

Nicolas Donders↗