Search NASA⌕ Search

SEARCH · Search NASA

Results for “photon counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Imaging the sun in hard X-rays - Spatial and rotating modulation collimators

Several approaches to imaging hard X-rays emitted from solar flares have been proposed or are planned for the nineties including the spatial modulation collimator (SMC) and the rotating modulation collimator (RMC). A survey of current solar flare theoretical literature indicates the desirability of spatial resolutions down to 1 arcsecond, field of views greater than the full solar disk (i.e., 32 arcminutes), and temporal resolutions down to 1 second. Although the sun typically provides relatively high flux levels, the requirement for 1 second temporal resolution raises the question as to the viability of Fourier telescopes subject to the aforementioned constraints. A basic photon counting, Monte Carlo 'end-to-end' model telescope was employed using the Astronomical Image Processing System (AIPS) for image reconstruction. The resulting solar flare hard X-ray images compared against typical observations indicated that both telescopes show promise for the future.

Campbell, Jonathan W.↗

Micro pulse lidar

An eye safe, compact, solid state lidar for profiling atmospheric cloud and aerosol scattering has been demonstrated. The transmitter of the micropulse lidar is a diode pumped micro-J pulse energy, high repetition rate Nd:YLF laser. Eye safety is obtained through beam expansion. The receiver employs a photon counting solid state Geiger mode avalanche photodiode detector. Data acquisition is by a single card multichannel scaler. Daytime background induced quantum noise is controlled by a narrow receiver field-of-view and a narrow bandwidth temperature controlled interference filter. Dynamic range of the signal is limited by optical geometric signal compression. Signal simulations and initial atmospheric measurements indicate that systems built on the micropulse lidar concept are capable of detecting and profiling all significant cloud and aerosol scattering through the troposphere and into the stratosphere. The intended applications are scientific studies and environmental monitoring which require full time, unattended measurements of the cloud and aerosol height structure.

Spinhirne, James D.↗

High-resolution Y-axis readout for delay-line microchannel anodes

We have devised a method to obtain a high-resolution Y-axis event position determination from microchannel plate delay-line detectors. The method is based on the double-delay-line wedge-wedge charge partition principle of Lampton et al. (1990), where the X axis is read out by a pair of side-by-side delay lines and the Y-axis coordinate is determined by comparing the charges on the two parallel delay lines. However, our new method abandons the common field return path of the two delay lines, and splits them into two adjacent but independent transformer coupled timing circuits having no common ground connection except via the charge-measurement amplifiers. Thus we eliminate the large electrostatic capacitance of the delay lines from the input of the charge-measuring system. Over its limited working field, the spatial resolution in the Y coordinate can easily equal the resolution provided in the X coordinate by the delay line. Applications to extreme and FUV photon-counting spectroscopy are envisioned.

Raffanti, R.↗

Raman-Augmented Stratospheric-Ozone Lidar

Differential-absorption lidar (DIAL) system measures concentration of ozone in stratosphere augmented with subsystem measuring Raman scattering from nitrogen. One of number of DIAL systems used in long-term monitoring of stratospheric ozone. Raman scattering from nitrogen provides data to correct for effects of aerosols. Channels at wavelengths of 332 and 385 nm added to DIAL receiver to measure Raman backscattering from nitrogen molecules in stratosphere. Data-acquisition electronics sample photon counts at a rate of 250 MHz.

Mcdermid, I. Stuart↗

Exploiting the cannibalistic traits of Reed-Solomon codes

In Reed-Solomon codes and all other maximum distance separable codes, there is an intrinsic relationship between the size of the symbols in a codeword and the length of the codeword. Increasing the number of symbols in a codeword to improve the efficiency of the coding system thus requires using a larger set of symbols. However, long Reed-Solomon codes are difficult to implement and many communications or storage systems cannot easily accommodate an increased symbol size, e.g., M-ary frequency shift keying (FSK) and photon-counting pulse-position modulation demand a fixed symbol size. A technique for sharing redundancy among many different Reed-Solomon codewords to achieve the efficiency attainable in long Reed-Solomon codes without increasing the symbol size is described. Techniques both for calculating the performance of these new codes and for determining their encoder and decoder complexities is presented. These complexities are usually found to be substantially lower than conventional Reed-Solomon codes of similar performance.

Collins, O.↗

Vacuum ultraviolet instrumentation for solar irradiance and thermospheric airglow

A NASA sounding rocket experiment was developed to study the solar extreme ultraviolet (EUV) spectral irradiance and its effect on the upper atmosphere. Both the solar flux and the terrestrial molecular nitrogen via the Lyman-Birge-Hopfield bands in the far ultraviolet (FUV) were measured remotely from a sounding rocket on October 27, 1992. The rocket experiment also includes EUV instruments from Boston University (Supriya Chakrabarti), but only the National Center for Atmospheric Research (NCAR)/University of Colorado (CU) four solar instruments and one airglow instrument are discussed here. The primary solar EUV instrument is a 1/4 meter Rowland circle EUV spectrograph which has flown on three rockets since 1988 measuring the solar spectral irradiance from 30 to 110 nm with 0.2 nm resolution. Another solar irradiance instrument is an array of six silicon XUV photodiodes, each having different metallic filters coated directly on the photodiodes. This photodiode system provides a spectral coverage from 0.1 to 80 nm with about 15 nm resolution. The other solar irradiance instrument is a silicon avalanche photodiode coupled with pulse height analyzer electronics. This avalanche photodiode package measures the XUV photon energy providing a solar spectrum from 50 to 12,400 eV (25 to 0.1 nm) with an energy resolution of about 50 eV. The fourth solar instrument is an XUV imager that images the sun at 17.5 nm with a spatial resolution of 20 arc-seconds. The airglow spectrograph measures the terrestrial FUV airglow emissions along the horizon from 125 to 160 nm with 0.2 nm spectral resolution. The photon-counting CODACON detectors are used for three of these instruments and consist of coded arrays of anodes behind microchannel plates. The one-dimensional and two-dimensional CODACON detectors were developed at CU by Dr. George Lawrence. The pre-flight and post-flight photometric calibrations were performed at our calibration laboratory and at the Synchrotron Ultraviolet Radiation Facility (SURF) at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland.

Woods, Thomas N.↗

How to squeeze high quantum efficiency and high time resolution out of a SPAD

We address the issue whether Single-Photon Avalanche Diodes (SPADs) can be suitably designed to achieve a trade-off between quantum efficiency and time resolution performance. We briefly recall the physical mechanisms setting the time resolution of avalanche photodiodes operated in single-photon counting, and we give some criteria for the design of SPADs with a quantum efficiency better than l0 percent at 1064 nm together with a time resolution below 50 ps rms.

Lacaita, A.↗

The solid state detector technology for picosecond laser ranging

We developed an all solid state laser ranging detector technology, which makes the goal of millimeter accuracy achievable. Our design and construction philosophy is to combine the techniques of single photon ranging, ultrashort laser pulses, and fast fixed threshold discrimination while avoiding any analog signal processing within the laser ranging chain. The all solid state laser ranging detector package consists of the START detector and the STOP solid state photon counting module. Both the detectors are working in an optically triggered avalanche switching regime. The optical signal is triggering an avalanche current buildup which results in the generation of a uniform, fast risetime output pulse.

Prochazka, Ivan↗

Micro pulse laser radar

An eye safe, compact, solid state lidar for profiling atmospheric cloud and aerosol scattering is disclosed. The transmitter of the micro pulse lidar is a diode pumped micro-J pulse energy, high repetition rate Nd:YLF laser. Eye safety is obtained through beam expansion. The receiver employs a photon counting solid state Geiger mode avalanche photodiode detector. Data acquisition is by a single card multichannel scaler. Daytime background induced quantum noise is controlled by a narrow receiver field-of-view and a narrow bandwidth temperature controlled interference filter. Dynamic range of the signal is limited to optical geometric signal compression. Signal simulations and initial atmospheric measurements indicate that micropulse lider systems are capable of detecting and profiling all significant cloud and aerosol scattering through the troposphere and into the stratosphere. The intended applications are scientific studies and environmental monitoring which require full time, unattended measurements of the cloud and aerosol height structure.

Spinhirne, James D.↗

Engine materials characterization and damage monitoring by using x ray technologies

X ray attenuation measurement systems that are capable of characterizing density variations in monolithic ceramics and damage due to processing and/or mechanical testing in ceramic and intermetallic matrix composites are developed and applied. Noninvasive monitoring of damage accumulation and failure sequences in ceramic matrix composites is used during room-temperature tensile testing. This work resulted in the development of a point-scan digital radiography system and an in situ x ray material testing system. The former is used to characterize silicon carbide and silicon nitride specimens, and the latter is used to image the failure behavior of silicon-carbide-fiber-reinforced, reaction-bonded silicon nitride matrix composites. State-of-the-art x ray computed tomography is investigated to determine its capabilities and limitations in characterizing density variations of subscale engine components (e.g., a silicon carbide rotor, a silicon nitride blade, and a silicon-carbide-fiber-reinforced beta titanium matrix rod, rotor, and ring). Microfocus radiography, conventional radiography, scanning acoustic microscopy, and metallography are used to substantiate the x ray computed tomography findings. Point-scan digital radiography is a viable technique for characterizing density variations in monolithic ceramic specimens. But it is very limited and time consuming in characterizing ceramic matrix composites. Precise x ray attenuation measurements, reflecting minute density variations, are achieved by photon counting and by using microcollimators at the source and the detector. X ray computed tomography is found to be a unique x ray attenuation measurement technique capable of providing cross-sectional spatial density information in monolithic ceramics and metal matrix composites. X ray computed tomography is proven to accelerate generic composite component development. Radiographic evaluation before, during, and after loading shows the effect of preexisting volume flaws on the fracture behavior of composites. Results from one-, three-, five-, and eight-ply ceramic composite specimens show that x ray film radiography can monitor damage accumulation during tensile loading. Matrix cracking, fiber-matrix debonding, fiber bridging, and fiber pullout are imaged throughout the tensile loading of the specimens. In situ film radiography is found to be a practical technique for estimating interfacial shear strength between the silicon carbide fibers and the reaction-bonded silicon nitride matrix. It is concluded that pretest, in situ, and post-test x ray imaging can provide greater understanding of ceramic matrix composite mechanical behavior.

Baaklini, George Y.↗

Hubble Space Telescope faint object camera instrument handbook (Post-COSTAR), version 5.0

The faint object camera (FOC) is a long-focal-ratio, photon-counting device capable of taking high-resolution two-dimensional images of the sky up to 14 by 14 arc seconds squared in size with pixel dimensions as small as 0.014 by 0.014 arc seconds squared in the 1150 to 6500 A wavelength range. Its performance approaches that of an ideal imaging system at low light levels. The FOC is the only instrument on board the Hubble Space Telescope (HST) to fully use the spatial resolution capabilities of the optical telescope assembly (OTA) and is one of the European Space Agency's contributions to the HST program.

Nota, A.↗

Real lasers and other deformed objects

In this talk we re-examine three important properties of quantum laser systems: (1) photon counting statistics; (2) squeezing; and (3) signal-to-quantum noise ratio. None of these phenomena depends on the choice of hamiltonian; indeed, we analyze them initially without restriction to any specific form of the commutation relations.

Solomon, Allan I.↗

Parametric Amplification For Detecting Weak Optical Signals

Optical-communication receivers of proposed type implement high-sensitivity scheme of optical parametric amplification followed by direct detection for reception of extremely weak signals. Incorporates both optical parametric amplification and direct detection into optimized design enhancing effective signal-to-noise ratios during reception in photon-starved (photon-counting) regime. Eliminates need for complexity of heterodyne detection scheme and partly overcomes limitations imposed on older direct-detection schemes by noise generated in receivers and by limits on quantum efficiencies of photodetectors.

Hemmati, Hamid↗

On a New Detection Scheme for M-ary Orthogonal Coherent State Signal

We propose a new receiver for M-ary orthogonal coherent-state signal. It is shown that the proposed receiver performs better than a photon counting receiver as to signal detection error probability criterion. It is also shown that the error probability of the proposed receiver is almost minimum for the signal.

Yamazaki, Kouichi↗

High Spectral Resolution Lidar Measurements of Multiple Scattering

The University of Wisconsin High Spectral Resolution Lidar (HSRL) provides unambiguous measurements of backscatter cross section, backscatter phase function, depolarization, and optical depth. This is accomplished by dividing the lidar return into separate particulate and molecular contributions. The molecular return is then used as a calibration target. We have modified the HSRL to use an I2 molecular absorption filter to separate aerosol and molecular signals. This allows measurement in dense clouds. Useful profiles extend above the cloud base until the two way optical depth reaches values between 5 and 6; beyond this, photon counting errors become large. In order to observe multiple scattering, the HSRL includes a channel which records the combined aerosol and molecular lidar return simultaneously with the spectrometer channel measurements of optical properties. This paper describes HSRL multiple scattering measurements from both water and ice clouds. These include signal strengths and depolarizations as a function of receiver field of view. All observations include profiles of extinction and backscatter cross sections. Measurements are also compared to predictions of a multiple scattering model based on small angle approximations.

Eloranta, E. W.↗

High Spatial Resolution Investigations of Microchannel Plate Imaging Properties for UV Detectors

Microchannel plate (MCP) photon counting detectors are currently being used with great success on many of the recent NASA/ESA ultraviolet (UV) astrophysics missions that make observations in the 1OO A - 1600 A range. These include HUT, the Wide Field Camera on ROSAT, EUVE, ALEXIS, ORFEUS, and SOHO. These devices have also been chosen to fly on future UV astrophysics missions such as FUSE, FUVITA, IMAGE, and both the HST STIS and Advanced Camera instruments. During the period of this award we have fabricated a dual-chamber vacuum test facility to carry out laboratory testing of detector resolution, image stability and linearity, and flat field performance to enable us to characterize the performance of MCPs and their associated read-out architectures. We have also fabricated and tested a laboratory 'test-bed' delay line detector, which can accommodate MCP's with a wide range of formats and run at high data rates, to continue our studies of MCP image fixed pattern noise, and particularly for new small pore MCP's which have recently come onto the market. These tests were mainly focussed on the assessment of cross delay-line (XDL) and double delay line (DDL) anode read-out schemes, with particular attention being focussed on flat-field and spatial resolution performance.

Siegmund, Oswald↗

The Corona of the Young Solar Analog EK Draconis

First coronal microwave and new soft X-ray observations of the very active, near-Zero-Age Main-Sequence (ZAMS) dGOe star EK Dra = HD 129333 show that this analog of the young Sun is more luminous in both emissions than most single M-dwarf flare stars. Variations in the 8.4 GHz flux include modulation with the optically determined rotation period of 2.7 days. This result points to a non-uniform filling of the corona with energetic electrons due to an incomplete coverage of the surface with active regions and a source volume that is not concentric with the star. The radio luminosity varying between log L(sub R) = 13.6 and 14.6 (L(sub R) in erg/s/Hz) shows evidence for unpolarized gyrosynchrotron flares, while strongly polarized flares were absent during the observations. This star is the first young, truly solar-like main sequence G star discovered in microwaves. Having just arrived on the main sequence, it conclusively proves that young, solar-like G stars can maintain very high levels of radio emission after their T Tau phase. The X-ray observations were obtained from the ROSAT All-Sky Survey (RASS). The average X-ray luminosity amounts to log L(sub x) = 29.9 (L(sub x) in erg/s). A Raymond-Smith type plasma model fit yields two plasma components at temperatures of 1.9 and 10 MK, with volume emission measures of 1.2 and 2.5 x 10 (exp 52)/cu cm, respectively. The X-ray light curve is significantly variable, with the photon count rate from the cooler plasma being strongly modulated by the rotation period; the emission from the hotter plasma is only weakly variable. Modeling of the source distribution in the stellar corona yields electron densities of the order of 4 x 10(exp 10)/cu cm or higher for the cool plasma component. It indicates that a considerable portion of EK Dra's high X-ray luminosity is due to high-density plasma rather than large emission volume. Parameters for an X-ray flare indicate an electron density of 1.75 x 10(exp 11)/cu cm and a source height of (1-2) x 10(exp 10) cm, compatible with a few times the scale height of the cooler plasma component.

Gudel, M.↗

Operational processing and cloud boundary detection from micro pulse lidar data

Micro Pulse Lidar (MPL) was developed at NASA Goddard Space Flight Center (GSFC) as the result of research on space-borne lidar techniques. It was designed to provide continuous, unattended observations of all significant atmospheric cloud and aerosol structure with a rugged, compact system design and the benefit of eye safety (Spinhirne 1993). The significant eye safety feature is achieved by using low pulse energies and high pulse repetition rates compared to standard lidar systems. MPL systems use a diode pumped 10 microj, 2500 Hz doubled Nd:YLF laser. In addition, a solid state Geiger mode avalanche photo diode (GAPD) photon counting detector is used allowing for quantum efficiencies approaching 70%. Other design features have previously been noted by Spinhirne (1995). Though a commercially available instrument, with nearly 20 systems operating around the world, the most extensive MPL work has come from those operated by the Atmospheric Radiation Measurement (ARM) (Stokes and Schwartz 1994) program. The diverse ability of the instrument relating to the measurement of basic cloud macrophysical structure and both cloud and aerosol radiative properties well suits the ARM research philosophy. MPL data can be used to yield many parameters including cloud boundary heights to the limit of signal attenuation, cloud scattering cross sections and optical thicknesses, planetary boundary layer heights and aerosol scattering profiles, including those into the stratosphere in nighttime cases (Hlavka et al 1996). System vertical resolution ranges from 30 m to 300 m (i.e. high and low resolution respectively) depending on system design. The lidar research group at GSFC plays an advisory role in the operation, calibration and maintenance of NASA and ARM owned MPL systems. Over the past three years, processing software and system correction techniques have been developed in anticipation of the increasing population of systems amongst the community. Datasets produced by three ARM-owned systems have served as the basis for this development. With two operating at the southern Great Plains Cloud and Radiation Testbed Site (SGP CART) since December 1993 and another at the Manus Island Atmospheric Radiation and Cloud Station (TWP ARCS) location in the tropical western Pacific since February 1997, the ARM archive contains over 4 years of observations. In addition, high resolution systems planning to come on-line at the North Slope, AK CART shortly with another scheduled to follow at the TWP ARCS-II will diversify this archive with more extensive observations.

Campbell, James R.↗