Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel array detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A new technique to characterize CT scanner bow-tie filter attenuation and applications in human cadaver dosimetry simulations

Purpose: To present a noninvasive technique for directly measuring the CT bow-tie filter attenuation with a linear array x-ray detector. Methods: A scintillator based x-ray detector of 384 pixels, 307 mm active length, and fast data acquisition (model X-Scan 0.8c4-307, Detection Technology, FI-91100 Ii, Finland) was used to simultaneously detect radiation levels across a scan field-of-view. The sampling time was as short as 0.24 ms. To measure the body bow-tie attenuation on a GE Lightspeed Pro 16 CT scanner, the x-ray tube was parked at the 12 o’clock position, and the detector was centered in the scan field at the isocenter height. Two radiation exposures were made with and without the bow-tie in the beam path. Each readout signal was corrected for the detector background offset and signal-level related nonlinear gain, and the ratio of the two exposures gave the bow-tie attenuation. The results were used in the GEANT4 based simulations of the point doses measured using six thimble chambers placed in a human cadaver with abdomen/pelvis CT scans at 100 or 120 kV, helical pitch at 1.375, constant or variable tube current, and distinct x-ray tube starting angles. Results: Absolute attenuation was measured with the body bow-tie scanned at 80–140 kV. For 24 doses measured in six organs of the cadaver, the median or maximum difference between the simulation results and the measurements on the CT scanner was 8.9% or 25.9%, respectively. Conclusions: The described method allows fast and accurate bow-tie filter characterization.

60 APPLIED LIFE SCIENCES↗

IRAC test report. Gallium doped silicon band 2: Read noise and dark current

A direct readout infrared detector array, a candidate for the Space Infrared Telescope Facility (SIRTF) Infrared Array Camera (IRAC), has been tested. The array has a detector surface of gallium doped silicon, bump bonded to a 58x62 pixel MOSFET multiplexer on a separate chip. Although this chip and system do not meet all the SIRTF requirements, the critically important read noise is within a factor of 3 of the requirement. Significant accomplishments of this study include: (1) development of a low noise correlated double sampling readout system with a readout noise of 127 to 164 electrons (based on the detector integrator capacitance of 0.1 pF); (2) measurement of the readout noise of the detector itself, ranging from 123 to 214 electrons with bias only (best to worst pixel), and 256 to 424 electrons with full clocking in normal operation at 5.4 K where dark current is small. Thirty percent smaller read noises are obtained at a temperature of 15K; (3) measurement of the detector response versus integration time, showing significant nonlinear behavior for large signals, well below the saturation level; and (4) development of a custom computer interface and suitable software for collection, analysis and display of data.

Lamb, Gerald↗

Initial On-Orbit Spatial Resolution Characterization of OrbView-3 Panchromatic Images

Characterization was conducted under the Memorandum of Understanding among Orbital Sciences Corp., ORBIMAGE, Inc., and NASA Applied Sciences Directorate. Acquired five OrbView-3 panchromatic images of the permanent Stennis Space Center edge targets painted on a concrete surface. Each image is available at two processing levels: Georaw and Basic. Georaw is an intermediate image in which individual pixels are aligned by a nominal shift in the along-scan direction to adjust for the staggered layout of the panchromatic detectors along the focal plane array. Georaw images are engineering data and are not delivered to customers. The Basic product includes a cubic interpolation to align the pixels better along the focal plane and to correct for sensor artifacts, such as smile and attitude smoothing. This product retains satellite geometry - no rectification is performed. Processing of the characterized images did not include image sharpening, which is applied by default to OrbView-3 image products delivered by ORBIMAGE to customers. Edge responses were extracted from images of tilted edges in two directions: along-scan and cross-scan. Each edge response was approximated with a superposition of three sigmoidal functions through a nonlinear least-squares curve-fitting. Line Spread Functions (LSF) were derived by differentiation of the analytical approximation. Modulation Transfer Functions (MTF) were obtained after applying the discrete Fourier transform to the LSF.

Blonski, Slawomir↗

The Primordial Inflation Explorer (PIXIE) Mission

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission to map the absolute intensity and linear polarization of the cosmic microwave background and diffuse astrophysical foregrounds over the full sky from frequencies 30 GHz to 6 THz (I cm to 50 I-tm wavelength). PIXIE uses a polarizing Michelson interferometer with 2.7 K optics to measure the difference spectrum between two orthogonal linear polarizations from two co-aligned beams. Either input can view either the sky or a temperature-controlled absolute reference blackbody calibrator. The multimoded optics and high etendu provide sensitivity comparable to kilo-pixel focal plane arrays, but with greatly expanded frequency coverage while using only 4 detectors total. PIXIE builds on the highly successful COBEIFIRAS design by adding large-area polarization-sensitive detectors whose fully symmetric optics are maintained in thermal equilibrium with the CMB. The highly symmetric nulled design provides redundant rejection of major sources of systematic uncertainty. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r much less than 10(exp -3). PIXIE will also return a rich data set constraining physical processes ranging from Big Bang cosmology, reionization, and large-scale structure to the local interstellar medium. Keywords: cosmic microwave background, polarization, FTS, bolometer

Kogut, Alan J.↗

Towards Energy Scale Calibration and Drift Correction of TES Detectors for Athena X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) comprises a 2376-pixel array of transition edge sensors (TES) read out with time-division multiplexing (TDM). X-IFU will provide spatially resolved, high-resolution spectroscopy (2.5 eV full-width-half-maximum up to 7 keV) over the energy range 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. The energy scale function maps the optimally filtered pulse height, in arbitrary engineering units, to real calibrated energy. Uncertainties in the calibration can result from imperfect fitting of the energy scale between the known calibration points. Furthermore, temporal changes in the TES operating environment, such as heat-sink temperature, magnetic field and bias voltage, can cause significant variations in the detector gain function over time. If not properly corrected, this can result in degradation of the energy resolution, and systematic errors in the absolute energy scale. The non-linear nature of TES detectors, coupled with the possibility of multiple simultaneously occurring sources of drift, can make effective corrections over the full bandpass of the instrument extremely challenging. Athena X-IFU will employ an on-board calibration source that provides known reference x-ray lines. This provides real-time monitoring of the gain stability of the detector system and information that can be used to correct for gain drifts. For X-IFU the baseline approach is to measure a series of calibration curves under different environmental conditions, which bound the expected drifts the instrument is predicted to see over the course of the mission. Using the information from the in-flight calibration source, these energy scale functions can be interpolated to generate a new corrected energy scale as a function of time. In this paper we discuss progress towards demonstrating that the X-IFU energy scale requirements can be met. We present measurements on ~ 200 pixels in a prototype X-IFU array read out with 8-column x 32-row TDM. We use a rotating target source containing 12 fluorescent targets to generate x-ray lines covering the energy range 4 keV (Sc-Kα) to 12 keV (Br-Kα). We present measurements of the non-linear energy scale function and show how variations in heat-sink temperature, TES bias voltage and magnetic field affect the shape of TES energy scale differently and introduce different residual gain errors over the bandpass. We explore different drift correction algorithms that use either a single or multiple referential lines to track and correct the gain from these various sources of drift. In addition to the pulse-height, the DC ‘baseline’ level of the TES can contain information about its bias conditions. Thus, we test a multi-parameter gain correction algorithm that attempts to incorporate both the pulse height and the additional baseline information into the algorithm.

Stephen J Smith↗

A 28 nm multiply-accumulate ASIC architecture for on-chip data compression in MHz frame rate X-ray and electron pixel detectors

Modern X-ray detector systems urgently require compact, efficient, and fast data compression schemes to handle the transmission of big data from pixel arrays, enabling frame rates in the MHz regime. Here, in this work, a data compression ASIC that implements a streaming fixed-length lossy compression scheme is introduced and analyzed, proving the feasibility and benefits of on-chip compression. The compression scheme utilizes a vector matrix product logic, which performs a number of floating-point multiplications, additions, and accumulations. The logic is verified, synthesized, and shown to fit in the area resource available for the X-ray detector under study, which comprises 192 × 168 pixels each of 12-bit width, and having a total area of 20 mm× 20 mm, about 2 mm× 20 mm of which are available for the digital logic. Several system architectures, precisions, and compression ratios ranging from 100 to 250 were analyzed to pave the way for on-chip fixed-length compression (e.g., principal component analysis, singular value decomposition) and data reduction (e.g., azimuthal integration) for X-ray and electron detectors.

Data compression↗

Wide field and diffraction limited array camera for SIRTF

The Infrared Array Camera for the space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors will be used: Band 1-InSb or Si:In (2-5 microns) 128 x 128 pixels, Band 2-Si:Ga (5-18 microns) 64 x 64 pixels, and Band 3-Si:Sb (18-30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and nondestructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: (1) diffraction-limited resolution from 2-30 microns, (2) use of the maximum unvignetted field of view of SIRTF, (3) simultaneous observations within the three infrared spectral bands, and (4) the capability for broad and narrow bandwidth spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements.

Fazio, G. G.↗

Wide field and diffraction limited array camera for SIRTF

The Infrared Array Camera for the Space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors are being considered: Band 1-InSb or Si:In (2-5 microns) 128 x 128 pixels, Band 2-Si:Ga (5-18 microns) 64 x 64 pixels, and Band 3-Si:Sb (18-30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and nondestructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: (1) diffraction-limited resolution from 2-30 microns, (2) use of the maximum unvignetted field of view of SIRTF, (3) simultaneous observations within the three infrared spectral bands, and (4) the capability for broad and narrow bandwidth spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements.

Fazio, G. G.↗

The HEXITEC Hard X-Ray Pixelated CdTe Imager for Fast Solar Observations

There is an increasing demand in solar and astrophysics for high resolution X-ray spectroscopic imaging. Such observations would present ground breaking opportunities to study the poorly understood high energy processes in our solar system and beyond, such as solar flares, X-ray binaries, and active galactic nuclei. However, such observations require a new breed of solid state detectors sensitive to high energy X-rays with fine independent pixels to sub-sample the point spread function (PSF) of the X-ray optics. For solar observations in particular, they must also be capable of handling very high count rates as photon fluxes from solar flares often cause pile up and saturation in present generation detectors. The Rutherford Appleton Laboratory (RAL) has recently developed a new cadmium telluride (CdTe) detector system, called HEXITEC (High Energy X-ray Imaging Technology). It is an 80 x 80 array of 250 micron independent pixels sensitive in the 2-200 keV band and capable of a high full frame read out rate of 10 kHz. HEXITEC provides the smallest independently read out CdTe pixels currently available, and are well matched to the few arcsecond PSF produced by current and next generation hard X-ray focusing optics. NASA's Goddard and Marshall Space Flight Centers are collaborating with RAL to develop these detectors for use on future space borne hard X-ray focusing telescopes. We show the latest results on HEXITEC's imaging capability, energy resolution, high read out rate, and reveal it to be ideal for such future instruments.

Baumgartner, Wayne H.↗

Novel laser-processed CsI:Tl detector for SPECT

Purpose: The aim of this work is to demonstrate the feasibility of a novel technique for fabrication of high spatial resolution CsI:Tl scintillation detectors for single photon emission computed tomography systems. Methods: The scintillators are fabricated using laser-induced optical barriers technique to create optical microstructures (or optical barriers) inside the CsI:Tl crystal bulk. The laser-processed CsI:Tl crystals are 3, 5, and 10 mm in thickness. In this work, the authors focus on the simplest pattern of optical barriers in that the barriers are created in the crystal bulk to form pixel-like patterns resembling mechanically pixelated scintillators. The monolithic CsI:Tl scintillator samples are fabricated with optical barrier patterns with 1.0 × 1.0 mm{sup 2} and 0.625 × 0.625 mm{sup 2} pixels. Experiments were conducted to characterize the fabricated arrays in terms of pixel separation and energy resolution. A 4 × 4 array of multipixel photon counter was used to collect the scintillation light in all the experiments. Results: The process yield for fabricating the CsI:Tl arrays is 100% with processing time under 50 min. From the flood maps of the fabricated detectors exposed to 122 keV gammas, peak-to-valley (P/V) ratios of greater than 2.3 are calculated. The P/V values suggest that regardless of the crystal thickness, the pixels can be resolved. Conclusions: The results suggest that optical barriers can be considered as a robust alternative to mechanically pixelated arrays and can provide high spatial resolution while maintaining the sensitivity in a high-throughput and cost-effective manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting THz Camera with GaAs‐JFET Cryogenic Readout Electronics

We describe the development of large format array of superconducting tunnel junction detectors that is readout by SONY GaAs‐JFET cryogenic integrated circuits. High quality SIS photon detectors have high dynamic impedance that can be readout by low gate leakage GaAs‐JFET circuits. Our imaging array design, with niobium SIS photon detectors and GaAs‐JFET cryogenics electronics, uses integrating amplifiers, multiplexers and shift‐registers to readout large number of pixels that is similar to CMOS digital cameras. We have designed and fabricated GaAs‐JFET cryogenic integrated circuits, such as AC‐coupled capacitive trans‐impedance amplifier, multiplexers with sample‐and‐holds and shift‐registers, for 32‐channel readout module. The Advanced Technology Center of National Astronomical Observatory of Japan have started extensive development program for large format array of SIS photon detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of large dual-polarized multichroic TES bolometer arrays for CMB measurements with the SPT-3G camera

This paper presents the procedures used by Argonne National Laboratory to fabricate large arrays of multichroic transition-edge sensor (TES) bolometers for cosmic microwave background (CMB) measurements. These detectors will be assembled into the focal plane for the SPT-3G camera, the third generation CMB camera to be installed in the South Pole Telescope. The complete SPT-3G camera will have approximately 2690 pixels, for a total of 16,140 TES bolometric detectors. Each pixel is comprised of a broad-band sinuous antenna coupled to a Nb microstrip line. In-line filters are used to define the different band-passes before the millimeter-wavelength signal is fed to the respective Ti/Au TES bolometers. There are six TES bolometer detectors per pixel, which allow for measurements of three band-passes (95 GHz, 150 GHz and 220 GHz) and two polarizations. The steps involved in the monolithic fabrication of these detector arrays are presented here in detail. Patterns are defined using a combination of stepper and contact lithography. The misalignment between layers is kept below 200 nm. The overall fabrication involves a total of 16 processes, including reactive and magnetron sputtering, reactive ion etching, inductively coupled plasma etching and chemical etching.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detectors based on silicon photomultiplier arrays for medical imaging applications

Silicon photomultipliers (SiPMs) have experienced a fast development and are now employed in different research fields. The availability of 2D arrays that provide information of the interaction position in the detector has had a high interest for medical imaging. Continuous crystals combined with segmented photodetectors can provide higher efficiency than pixellated crystals and very high spatial resolution. The IRIS group at IFIC is working on the development of detector heads based on continuous crystals coupled to SiPM arrays for different applications, including a small animal PET scanner in collaboration with the Univ. of Pisa and INFN Pisa, and a Compton telescope for dose monitoring in hadron therapy. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of CMOS Sensors for HEP with a US-based foundry

We will present a program to establish the first development and manufacturing of HEP-specific sensors monolithically integrated into a standard CMOS process using a US-based foundry. In collaboration with several US universities the project aims to develop Monolithic Active Pixel Sensors (MAPS) designs implemented in the 90 nm technology node, including simple test structures and multi-pixel arrays, and monolithic CMOS sensors with readout integrated circuits, perform detailed characterization of the detector prototypes and quantify their performance for HEP applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of optimized detector/spectrophotometer technology for low background space astronomy missions

This program was directed towards a better understanding of some of the important factors in the performance of infrared detector arrays at low background conditions appropriate for space astronomy. The arrays were manufactured by Aerojet Electrosystems Corporation, Azusa. Two arrays, both bismuth doped silicon, were investigated: an AMCID 32x32 Engineering mosiac Si:Bi accumulation mode charge injection device detector array and a metal oxide semiconductor/field effect transistor (MOS-FET) switched array of 16x32 pixels.

Jones, B.↗

Status of the isophot detector development

ISOPHOT is one of the four focal plane experiments of the European Space Agency's Infrared Space Observatory (ISO). Scheduled for a 1993 launch, it will operate extrinsic silicon and germanium photoconductors at low temperature and low background during the longer than 18 month mission. These detectors cover the wavelength range from 2.5 to 200 microns and are used as single elements and in arrays. A cryogenic preamplifier was developed to read out a total number of 223 detector pixels.

Wolf, J.↗

Detector Modeling and CMB Polarimetry Technology Development at GSFC

Pixel size limits the resolution in the focal plane. This should be accounted for in optical design. Alternatively, this reduces the effective number of independent detectors. Polarization and scattering are intrinsically related, and both are more severe at low pnambda. Future work: Quantification of the pixel cross-coupling- calculate a theoretical covariance matrix to predict performance of future detector arrays.

Chuss, David T.↗

Mosaic-Detector-Based Fluorescence Spectral Imager

A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.

Son, Kyung-Ah↗