Search NASA⌕ Search

SEARCH · Search NASA

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Ligand effect on switching the rate-determining step of water oxidation in atomically precise metal nanoclusters

The ligand effects of atomically precise metal nanoclusters on electrocatalysis kinetics have been rarely revealed. Herein, we employ atomically precise Au 25 nanoclusters with different ligands (i.e., para-mercaptobenzoic acid, 6-mercaptohexanoic acid, and homocysteine) as paradigm electrocatalysts to demonstrate oxygen evolution reaction rate-determining step switching through ligand engineering. Au 25 nanoclusters capped by para-mercaptobenzoic acid exhibit a better performance with nearly 4 times higher than that of Au 25 NCs capped by other two ligands. We deduce that para-mercaptobenzoic acid with a stronger electron-withdrawing ability establishes more partial positive charges on Au(I) (i.e., active sites) for facilitating feasible adsorption of OH – in alkaline media. X-ray photo-electron spectroscopy and theoretical study indicate a profound electron transfer from Au(I) to para-mercaptobenzoic acid. The Tafel slope and in situ Raman spectroscopy suggest different ligands trigger different rate-determining step for these Au 25 nanoclusters. The mechanistic insights reported here can add to the acceptance of atomically precise metal nanoclusters as effective electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomically precise engineering of spin–orbit polarons in a kagome magnetic Weyl semimetal

Atomically precise defect engineering is essential to manipulate the properties of emerging topological quantum materials for practical quantum applications. However, this remains challenging due to the obstacles in modifying the typically complex crystal lattice with atomic precision. Here, we report the atomically precise engineering of the vacancy-localized spin–orbit polarons in a kagome magnetic Weyl semimetal Co 3 Sn 2 S 2 , using scanning tunneling microscope. We achieve the step-by-step repair of the selected vacancies, leading to the formation of artificial sulfur vacancies with elaborate geometry. We find that that the bound states localized around these vacancies undergo a symmetry dependent energy shift towards Fermi level with increasing vacancy size. As the vacancy size increases, the localized magnetic moments of spin–orbit polarons become tunable and eventually become itinerantly negative due to spin–orbit coupling in the kagome flat band. These findings provide a platform for engineering atomic quantum states in topological quantum materials at the atomic scale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TEMImageNet training library and AtomSegNet deep-learning models for high-precision atom segmentation, localization, denoising, and deblurring of atomic-resolution images

Abstract Atom segmentation and localization, noise reduction and deblurring of atomic-resolution scanning transmission electron microscopy (STEM) images with high precision and robustness is a challenging task. Although several conventional algorithms, such has thresholding, edge detection and clustering, can achieve reasonable performance in some predefined sceneries, they tend to fail when interferences from the background are strong and unpredictable. Particularly, for atomic-resolution STEM images, so far there is no well-established algorithm that is robust enough to segment or detect all atomic columns when there is large thickness variation in a recorded image. Herein, we report the development of a training library and a deep learning method that can perform robust and precise atom segmentation, localization, denoising, and super-resolution processing of experimental images. Despite using simulated images as training datasets, the deep-learning model can self-adapt to experimental STEM images and shows outstanding performance in atom detection and localization in challenging contrast conditions and the precision consistently outperforms the state-of-the-art two-dimensional Gaussian fit method. Taking a step further, we have deployed our deep-learning models to a desktop app with a graphical user interface and the app is free and open-source. We have also built a TEM ImageNet project website for easy browsing and downloading of the training data.

25 ENERGY STORAGE↗

Data-driven distillation and precision prognosis in traumatic brain injury with interpretable machine learning

Traumatic brain injury (TBI) affects how the brain functions in the short and long term. Resulting patient outcomes across physical, cognitive, and psychological domains are complex and often difficult to predict. Major challenges to developing personalized treatment for TBI include distilling large quantities of complex data and increasing the precision with which patient outcome prediction (prognoses) can be rendered. We developed and applied interpretable machine learning methods to TBI patient data. We show that complex data describing TBI patients' intake characteristics and outcome phenotypes can be distilled to smaller sets of clinically interpretable latent factors. We demonstrate that 19 clusters of TBI outcomes can be predicted from intake data, a ~ 6× improvement in precision over clinical standards. Finally, we show that 36% of the outcome variance across patients can be predicted. These results demonstrate the importance of interpretable machine learning applied to deeply characterized patients for data-driven distillation and precision prognosis.

60 APPLIED LIFE SCIENCES↗

Precise determination of the sigma pole location from a dispersive analysis

We review how the use of recent precise data on kaon decays together with forward dispersion relations (FDR) and Roy's equations allow us to determine the sigma resonance pole position very precisely, by using only experimental input. In addition, we present preliminary results for a modified set of Roy-like equations with only one subtraction, that show a remarkable improvement in the precision around the {sigma} region. For practical applications, these results are shown to be very well approximated by a very simple conformal expansion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision in Strontium Isotope Measurements by Laser Ablation Assisted Resonance Ionization Mass Spectrometry

We have investigated the precision of strontium isotope analysis by Laser Ablation-assisted Resonance Ionization Mass Spectrometry(LA-RIMS). We have confirmed that the mass discrimination effect on the {sup 87}Sr/{sup 86}Sr measurement was reduced by the internal correction method. For the present system, the precision of the isotope ratio of {sup 87}Sr/{sup 86}Sr has been estimated to be 0.6%(1{sigma}). The precision has been limited by the fluctuations with a time scale of less than 10 s.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision Fast Ion Beam Laser Spectroscopy of Ar{sup +}

Absolute measurements of spectral lines of Ar{sup +} ions using collinear and anticollinear geometries were performed. To provide a precise reference for the laser wavelength, iodine saturation spectroscopy was applied. The precision of this reference is effected by observing the beat node between the spectroscopy laser and the corresponding mode of a femtosecond laser frequency comb. Laser-induced fluorescence allowed to perform precision frequency measurements of an Ar{sup +} transition in collinear and anticollinear geometries simultaneously; then an exact relativistic formula for the absolute transition frequency V{sub 0} = {radical}(V{sub c}V{sub a}) was used. In this geometry the influence of ion source instabilities due to pressure and anode voltage fluctuations was minimized. The result is v{sub 0} = 485,573,619.7(3) MHz, which corresponds to {delta}v/v = 6*10{sup -10}. This represents an improvement of two orders of magnitude over the previous NIST published value.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Q{sub weak}{sup p} Experiment A Test for Physics Beyond the Standard Model via a Precision Measurement of the Proton Weak Charge

The Qweak collaboration is currently preparing a measurement of the proton's weak charge Q{sub w}{sup p} = (1-4 sin{sup 2} {theta}{sub w}) at the Thomas Jefferson National Accelerator Facility (TJNAF). The experiment has been designed to produce a 4.1% measurement of the weak charge, via a 2.5% measurement of the parity violating asymmetry in the number of elastically scattered 1 GeV electrons from protons, at forward angles. At the proposed precision, the experiment would produce a 0.3% measurement of the weak mixing angle at a momentum transfer of {approx_equal}0.16 GeV, making it the most precise stand alone measurement of the weak mixing angle at low momentum transfer. In combination with other parity measurements, Qweak will also provide a high precision determination of the weak charges of the up and down quarks. Our proposed measurement of Q{sub w}{sup 2} will be performed with significantly smaller statistical and systematic errors than existing low Q{sup 2} data. Any significant deviation from the Standard Model prediction at low momentum transfer (Q{sup 2}) would be a signal of new physics, whereas agreement would place new and significant constraints on possible Standard Model extensions. The experiment is currently being prepared for installation, beginning in late 2009, and data taking beginning in mid 2010.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Precision Time Delay Control with Continuous Phase Shifter for Pump-Probe Experiments Using Synchrotron Radiation Pulses

Brilliant pulsed x-ray synchrotron radiation (SR) is useful for pump-probe experiment such as time-resolved x-ray diffraction, x-ray absorption fine structure, and x-ray spectroscopy. For laser pump-SR x-ray probe experiments, short pulsed lasers are generally synchronized to the SR master oscillator controlling the voltage for acceleration of electron bunches in an accelerator, and the interval between the laser and the SR pulses is changed around the time scale of target phenomenon. Ideal delay control produces any time delay as keeping the time-precision and pointing-stability of optical pulses at a sample position. We constructed the time delay control module using a continuous phase shifter of radio frequency signal and a frequency divider, which can produce the delayed trigger pulses to the laser without degradation of the time precision and the pointing stability. A picoseconds time-resolved x-ray diffraction experiment was demonstrated at SPring-8 storage ring for fast lattice response by femtosecond pulsed laser irradiation, and suggested the possibility of accurate sound velocity measurement. A delay control unit operating with subpicosecond precision has also been designed for femtosecond pump-probe experiments using a free electron laser at SPring-8 campus.

43 PARTICLE ACCELERATORS↗

Precision linac and laser technologies for nuclear photonics gamma-ray sources

Tunable, high precision gamma-ray sources are under development to enable nuclear photonics, an emerging field of research. This paper focuses on the technological and theoretical challenges related to precision Compton scattering gamma-ray sources. In this scheme, incident laser photons are scattered and Doppler upshifted by a high brightness electron beam to generate tunable and highly collimated gamma-ray pulses. The electron and laser beam parameters can be optimized to achieve the spectral brightness and narrow bandwidth required by nuclear photonics applications. A description of the design of the next generation precision gamma-ray source currently under construction at Lawrence Livermore National Laboratory is presented, along with the underlying motivations. Within this context, high-gradient X-band technology, used in conjunction with fiber-based photocathode drive laser and diode pumped solid-state interaction laser technologies, will be shown to offer optimal performance for high gamma-ray spectral flux, narrow bandwidth applications.

43 PARTICLE ACCELERATORS↗

Progress on precision measurements of inner shell transitions in highly charged ions at an ECR ion source

Inner shell transitions of highly charged ions produced in the plasma of an Electron Cyclotron Resonance Ion Source (ECRIS) were observed the first time by a Double Crystal Spectrometer (DCS). The DCS is a well-used tool in precision x-ray spectroscopy due to its ability of precision wavelength measurement traced back to a relative angle measurement. Because of its requirement for a bright x-ray source the DCS has not been used before in direct measurements of highly charged ions (HCI). Our new precision measurement of inner shell transitions in HCI is not just going to provide new x-ray standards for quantum metrology but can also give information about the plasma in which the ions reside. Ionic temperatures and with that the electron density can be determined by thorough examination of line widths measured with great accuracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigation on focusing characteristics of a He-Ne laser using circular Fresnel zone plate for high-precision alignment of linear accelerators

We experimentally investigate the focusing characteristics of a He-Ne laser at the focal region for the high-precision alignment of long-distance linear accelerators using a circular Fresnel zone plate. The laser wave passing through the Fresnel zone plate having a focal length of 66.7 m propagates for a 268-m-long distance at atmospheric pressure. A new laser-based alignment system using Fresnel zone plates as the alignment targets is discussed. The transverse displacement of the focused spot of the laser is measured as a function of the displacement of the target by a detector installed at the focal point. Systematic studies on the focusing characteristics and alignment precision have been successfully conducted in this experiment. The experimental results are in good agreement with theoretical calculations, and the alignment precision of the target is determined to be less than {+-}30 {mu}m. In this study, we perform a detailed experimental investigation on the laser propagation and focusing characteristics using the circular Fresnel zone plate at the focal region along with theoretical calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superallowed nuclear beta decay: Precision measurements for basic physics

For 60 years, superallowed 0{sup +}{yields}0{sup +} nuclear beta decay has been used to probe the weak interaction, currently verifying the conservation of the vector current (CVC) to high precision ({+-}0.01%) and anchoring the most demanding available test of the unitarity of the Cabibbo-Kobayashi-Maskawa (CKM) matrix ({+-}0.06%), a fundamental pillar of the electroweak standard model. Each superallowed transition is characterized by its ft-value, a result obtained from three measured quantities: the total decay energy of the transition, its branching ratio, and the half-life of the parent state. Today's data set is composed of some 150 independent measurements of 13 separate superallowed transitions covering a wide range of parent nuclei from {sup 10}C to {sup 74}Rb. Excellent consistency among the average results for all 13 transitions - a prediction of CVC - also confirms the validity of the small transition-dependent theoretical corrections that have been applied to account for isospin symmetry breaking. With CVC consistency established, the value of the vector coupling constant, G{sub V}, has been extracted from the data and used to determine the top left element of the CKM matrix, V{sub ud}. With this result the top-row unitarity test of the CKM matrix yields the value 0.99995(61), a result that sets a tight limit on possible new physics beyond the standard model. To have any impact on these fundamental weak-interaction tests, any measurement must be made with a precision of 0.1% or better - a substantial experimental challenge well beyond the requirements of most nuclear physics measurements. I overview the current state of the field and outline some of the requirements that need to be met by experimentalists if they aim to make measurements with this high level of precision.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved strain precision with high spatial resolution using nanobeam precession electron diffraction

NanoBeam Electron Diffraction is a simple and efficient technique to measure strain in nanostructures. Here, we show that improved results can be obtained by precessing the electron beam while maintaining a few nanometer probe size, i.e., by doing Nanobeam Precession Electron Diffraction (N-PED). The precession of the beam makes the diffraction spots more uniform and numerous, making N-PED more robust and precise. In N-PED, smaller probe size and better precision are achieved by having diffraction disks instead of diffraction dots. Precision in the strain measurement better than 2 × 10{sup −4} is obtained with a probe size approaching 1 nm in diameter.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Light leptonic new physics at the precision frontier

Precision probes of new physics are often interpreted through their indirect sensitivity to short-distance scales. In this proceedings contribution, we focus on the question of which precision observables, at current sensitivity levels, allow for an interpretation via either short-distance new physics or consistent models of long-distance new physics, weakly coupled to the Standard Model. The electroweak scale is chosen to set the dividing line between these scenarios. In particular, we find that inverse see-saw models of neutrino mass allow for light new physics interpretations of most precision leptonic observables, such as lepton universality, lepton flavor violation, but not for the electron EDM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage

The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software TEMA Motion is used to track the spot which marked the cage surface. Finally, by developing the MATLAB program, a Lissajous’ figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-precision measurement of magnetic penetration depth in superconducting films

We report that the magnetic penetration depth (λ) in thin superconducting films is usually measured by the mutual inductance technique. The accuracy of this method has been limited by uncertainties in the geometry of the solenoids and in the film position and thickness, by parasitic coupling between the coils, etc. Here, we present several improvements in the apparatus and the method. To ensure the precise thickness of the superconducting layer, we engineer the films at atomic level using atomic-layer-by-layer molecular beam epitaxy. In this way, we also eliminate secondary-phase precipitates, grain boundaries, and pinholes that are common with other deposition methods and that artificially increase the field transmission and thus the apparent λ. For better reproducibility, the thermal stability of our closed-cycle cryocooler used to control the temperature of the mutual inductance measurement has been significantly improved by inserting a custom-built thermal conductivity damper. Next, to minimize the uncertainties in the geometry, we fused a pair of small yet precisely wound coils into a single sapphire block machined to a high precision. Lastly, the sample is spring-loaded to exactly the same position with respect to the solenoids. Altogether, we can measure the absolute value of λ with the accuracy better than ±1%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A fused silica Cherenkov radiator for high precision time-of-flight measurement of DT γ and neutron spectra (invited)

A fused silica Cherenkov radiator has been utilized at the National Ignition Facility to provide a new high precision measurement of the time-of-flight spectrum of 14.1 MeV DT fusion neutrons. This detector allows a high precision (<30 ps) co-registered measurement of both a thresholded γ-ray and a neutron spectrum on a single record. Other approaches typically require γ and neutron signals to be co-registered via other diagnostics and/or dedicated timing experiments. Analysis of the co-registered γ and neutron signals allows precise extraction of the mean neutron energy and bulk hot-spot velocity, both of which were not possible with prior scintillator technologies. Initial measurements demonstrate the feasibility of this measurement and indicate that combined detection of neutrons and γ-rays on multiple lines-of-sight should enable the bulk vector velocity of the implosion hot-spot to be determined to ≈5 km/s and reduced uncertainty in the spectral width ≈0.1 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗