Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Micro-Tubular Fuel Cells

Micro-tubular fuel cells that would operate at power levels on the order of hundreds of watts or less are under development as alternatives to batteries in numerous products - portable power tools, cellular telephones, laptop computers, portable television receivers, and small robotic vehicles, to name a few examples. Micro-tubular fuel cells exploit advances in the art of proton-exchange-membrane fuel cells. The main advantage of the micro-tubular fuel cells over the plate-and-frame fuel cells would be higher power densities: Whereas the mass and volume power densities of low-pressure hydrogen-and-oxygen-fuel plate-and-frame fuel cells designed to operate in the targeted power range are typically less than 0.1 W/g and 0.1 kW/L, micro-tubular fuel cells are expected to reach power densities much greater than 1 W/g and 1 kW/L. Because of their higher power densities, micro-tubular fuel cells would be better for powering portable equipment, and would be better suited to applications in which there are requirements for modularity to simplify maintenance or to facilitate scaling to higher power levels. The development of PEMFCs has conventionally focused on producing large stacks of cells that operate at typical power levels >5 kW. The usual approach taken to developing lower-power PEMFCs for applications like those listed above has been to simply shrink the basic plate-and-frame configuration to smaller dimensions. A conventional plate-and-frame fuel cell contains a membrane/electrode assembly in the form of a flat membrane with electrodes of the same active area bonded to both faces. In order to provide reactants to both electrodes, bipolar plates that contain flow passages are placed on both electrodes. The mass and volume overhead of the bipolar plates amounts to about 75 percent of the total mass and volume of a fuel-cell stack. Removing these bipolar plates in the micro-tubular fuel cell significantly increases the power density.

Kimble, Michael C.↗

Heat-transfer and pressure measurements on a simulated elevon deflected 30 deg near flight conditions at Mach 7

Heat transfer rates and pressures were obtained on an elevon plate (deflected 30 deg) and a flat plate upstream of the elevon in an 8 foot high-temperature structures tunnel. The flight Reynolds number and flight total enthalpy for altitudes of 26.8 km and 28.7 km at Mach seven were duplicated. The heat transfer and pressure data were used to establish heating and pressure loads. The measured heating was compared with several theoretical predictions, and the closest agreement obtained with a Schultz-Grunow reference enthalpy method of calculation.

Johnson, C. B.↗

Experimental program to determine long term characteristics of the MDE pressure transducers

The pressure cell sensors developed for the Pioneer 10/G meteoroid detection experiments (MDE) were investigated to enhance their application and their potential as a sensor in other MDE applications. Their Paschen characteristics were also investigated, and the effects of variations in geometry, Ni-63 platings (for initial ionizations) and sealing pressures were determined. The effects of extensive pre-flight testing and proton and heavy ion space radiation were investigated. Flight-quality pressure panels/cells were committed to long term testing to demonstrate their suitability for the Pioneer 10/G Missions.

Parker, C. D.↗

Crossflow instability control on a swept-wing: Preliminary studies

The pressure distribution on a swept wing causes the streamlines at the edge of the boundary layer to be curved. This pressure gradient normal to the external streamline creates a velocity component normal to the external streamline within the boundary layer which is referred to as the crossflow velocity. Because the crossflow velocity profile perpendicular to the wing surface has an inflection point, the profile is unstable. The stationary instability mode takes the form of crossflow vortices. Under these conditions, the boundary layer on the wing is extremely unstable and transition to turbulent flow takes place much closer to the leading edge of the wing than it would on an unswept wing. Higher skin friction drag is associated with turbulent flow, and so better aircraft performance could be obtained if the crossflow could be eliminated One method of controlling crossflow that is being investigated is boundary-layer suction. An extensive airfoil suction experiment in the 8 feet Transonic Pressure Tunnel (TPT) at NASA Langley Research Center will begin late in 1994. Because of the size, complexity, and expense associated with this test, a number of 'risk-reduction' tests are currently being conducted. The 20 x 28 in. Shear Flow Control Tunnel at NASA Langley is being used for some of these tests. Prior to the summer of 1994, a flat plate with a swept leading edge was installed in the 20 x 28 in. tunnel, with a displacement body mounted on the tunnel ceiling that created a pressure distribution on the plate similar to the pressure distribution on a swept wing. The flow over the plate was investigated during the summer of 1994 using a laser Doppler velocimeter (LDV) system. The LDV measurements indicated the possible presence of multiple disturbance modes, a rarely-seen phenomena since, in most tests, one disturbance mode dominates. The possible existence of multiple disturbance modes in the flat plate boundary layer, however, means that the flow in the 20 x 28 in. tunnel is of interest itself, and will be investigated more thoroughly in the future. With a view to these investigations, the boundary layer traverse mechanism in the 20 x 28 in. tunnel was modified to improve its performance, and strain gauges were mounted on the traverse in order to monitor its deflection during a test. Other preliminary work conducted in the 20 x 28 in. tunnel included the use of an infrared camera system. Previous work with this system showed that transition indeed could be detected, but the signal produced by the crossflow vortices was too weak to be detected. It was hoped that spraying the flat plate with naphthalene would augment the heat transfer associated with the crossflow vortices so that they would show up in a IR image; however, experiments showed that this would not work. Another set of tests was conducted in the 20 x 28 in. tunnel to determine the tripping requirements for a set of airfoil-shaped struts that will be used in the 8 feet TPT experiment. Since the Reynolds number associated with these struts is small, a laminar boundary layer would separate early, causing large fluctuations in the flow field. A turbulent boundary layer would remain attached further back, but tripping from laminar to turbulent flow at low Reynolds number is very difficult. However, trip strip configurations were found that should effectively trip the boundary layer at the required conditions. Currently underway is an investigation of the data acquisition requirements for the 8 feet TPT experiment, with the purpose of the finding the minimum amount of data needed to characterize sufficiently the swept-wing boundary layer. This study is being conducted using a numerically generated data set.

Bridges, David H.↗

Computational Non-Destructive Evaluation Improving Ultrasonic Interrogation of Complex Geometry Composite Parts

Finite element simulation was employed in modeling the ultrasound (UT) pressure pulse propagation through a coupled liquid-composite medium to reproduce experimental data. From the simulation point of view, the proposed approach is challenging when there is a large simulation domain. For example, it is shown that a sub-micron wavelength of an ultrasonic wave requires a mesh size of several microns and this in turn requires significant computational resources, as well as special care in modeling. Some of the simulation results are presented considering that such modeling should reproduce experimental data for a healthy and faulty composite structure with complex geometry. Many possible experimental setups are simulated to demonstrate the non-destructive testing technique. This setup includes the generation of pressure pulse propagating through the tested composite plate and possible scattering by discontinuities (area of different impedance) that may be present in the panel. This scattered pulse together with the baseline pressure pulse generates a signature on the probe element which can be used to locate the position of defects in the structures.

modeling↗

Effects of pressure waves

Two parameters, side on overpressure and side on impulse loads, and their application to the determination of structural damage to buildings and vehicles in the vicinity of an explosion are investigated. Special consideration was given to what constitutes damage and what level of damage is acceptable. Solutions were sorted through the examination of glass breakage, curve fit to bomb damage, overturning of marginal structures (buses, trucks, mobile homes) subject to toppling, and initiation of yielding in either beam or plate structural components. Three different empirical pressure versus impulse diagrams were presented - the first is for minor structural damage involving wrenched joints and partitions, the second is for major damage structural damage with load bearing members at least partially destroyed, and the third is for 50% to 75% of the building demolished. General guidelines were obtained from the results when the accurate structural details are unknown.

Source record↗

Comparison of aerogrids and punched plates for smoothing flow from short annular diffusers

Scale model tests were conducted to evaluate the effectiveness of aerogrids and punched plates in producing flat velocity profiles downstream of short diffusers as would be used between the compressor and combustor of advanced aircraft engines. The diffuser had an area ratio of 4.17 and a length-to-inlet-height ratio of 2.07. The aerogrids tested were plates containing 1123 contoured venturis in parallel with geometric blockages of 83, 74, and 61 percent, respectively. The punched plates contained 1123 sharp-edged orifices with blockages of 58 and 30 percent. The results show that aerogrids, with higher effective blockage for the same pressure loss, are more effective flow-smoothing devices than the punched plates. Also, the overall pressure loss decreases and the exit velocity profile becomes flatter as either type of grid is moved closer to the diffuser exit plane.

Rumpf, R. L.↗

Low cost fabrication development for oxide dispersion strengthened alloy vanes

Viable processes were developed for secondary working of oxide dispersion strengthened (ODS) alloys to near-net shapes (NNS) for aircraft turbine vanes. These processes were shown capable of producing required microstructure and properties for vane applications. Material cost savings of 40 to 50% are projected for the NNS process over the current procedures which involve machining from rectangular bar. Additional machining cost savings are projected. Of three secondary working processes evaluated, directional forging and plate bending were determined to be viable NNS processes for ODS vanes. Directional forging was deemed most applicable to high pressure turbine (HPT) vanes with their large thickness variations while plate bending was determined to be most cost effective for low pressure turbine (LPT) vanes because of their limited thickness variations. Since the F101 LPT vane was selected for study in this program, development of plate bending was carried through to establishment of a preliminary process. Preparation of ODS alloy plate for bending was found to be a straight forward process using currently available bar stock, providing that the capability for reheating between roll passes is available. Advanced ODS-NiCrAl and ODS-FeCrAl alloys were utilized on this program. Workability of all alloys was adequate for directional forging and plate bending, but only the ODS-FeCrAl had adequate workability for shaped preform extrustion.

Perkins, R. J.↗

Numerical simulations of supersonic flow through oscillating cascade sections

A finite difference code was developed for modeling inviscid, unsteady supersonic flow by solution of the compressible Euler equations. The code uses a deforming grid technique to capture the motion of the airfoils and can model oscillating cascades with any arbitrary interblade phase angle. A flat plate cascade is analyzed, and results are compared with results from a small perturbation theory. The results show very good agreement for both the unsteady pressure distributions and the integrated force predictions. The reason for using the numerical Euler code over a small perturbation theory is the ability to model real airfoils that have thickness and camber. Sample predictions are presented for a cascade of loaded airfoils and show appreciable differences in the unsteady surface pressure distributions when compared with the flat plate results.

Huff, Dennis L.↗

Evaporative Cooling and Dehumidification Garment for Portable Life Support Systems

This paper describes the design and development of an innovative thermal and humidity control system for future space suits. The system comprises an evaporation cooling and dehumidification garment (ECDG) and a lithium chloride absorber radiator (LCAR). The ECDG absorbs heat and water vapor from inside the suit pressure garment, while the LCAR rejects heat to space without venting water vapor. The ECDG is built from thin, flexible patches with coversheets made of non-porous, water-permeable membranes that -enclose arrays of vapor flow passages. Water vapor from inside the spacesuit diffuses across the water permeable membranes, enters the vapor flow channels, and then flows to the LCAR, thus dehumidifying the internal volume of the space suit pressure garment. Additional water evaporation inside the ECDG provides cooling for sensible heat loads. -The heat released from condensation and absorption in the LCAR is rejected to the environment by thermal radiation. We have assembled lightweight and flexible ECDG pouches from prototypical materials and measured their performance in a series of separate effects tests under well-controlled, prototypical conditions. Sweating hot plate tests at typical space suit pressures show that ECDG pouches can absorb over 60 W/ft of latent heat and 20 W/ft of sensible heat from the pressure garment environment. These results are in good agreement with the predictions of our analysis models.

Izenson, Michael↗

Transitional Bubble in Periodic Flow Phase Shift

One particular characteristic observed in unsteady shear layers is the phase shift relative to the main flow. In attached boundary layers this will have an effect both on the instantaneous skin friction and heat transfer. In separation bubbles the contribution to the drag is dominated by the pressure distribution. However, the most significant effect appears to be the phase shift on the transition process. Unsteady transition behaviour may determine the bursting of the bubble resulting in an un-recoverable full separation. An early analysis of the phase shift was performed by Stokes for the incompressible boundary layer of an oscillating wall and an oscillating main flow. An amplitude overshoot within the shear layer as well as a phase shift were observed that can be attributed to the relatively slow diffusion of viscous stresses compared to the fast change of pressure. Experiments in a low speed facility with the boundary layer of a flat plate were evaluated in respect to phase shift. A pressure distribution similar to that on the suction surface of a turbomachinery aerofoil was superimposed generating a typical transitional separation bubble. A periodically unsteady main flow in the suction type wind tunnel was introduced via a rotating flap downstream of the test section. The experiments covered a range of the three similarity parameters of momentum-loss-thickness Reynolds-number of 92 to 226 and Strouhal-number (reduced frequency) of 0.0001 to 0.0004 at the separation point, and an amplitude range up to 19 %. The free stream turbulence level was less than 1% .Upstream of the separation point the phase shift in the laminar boundary layer does not appear to be affected significantly bay either of the three parameters. The trend perpendicular to the wall is similar to the Stokes analysis. The problem scales well with the wave velocity introduced by Stokes, however, the lag of the main flow near the wall is less than indicated analytically. The separation point comes closest to the Stokes analysis but the phase is still 20 degrees lower at the wall.

Talan, M.↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Pressure and heating-rate distributions on a corrugated surface in a supersonic turbulent boundary layer

Drag and heating rates on wavy surfaces typical of current corrugated plate designs for thermal protection systems were determined experimentally. Pressure-distribution, heating-rate, and oil-flow tests were conducted in the Langley Unitary Plan wind tunnel at Mach numbers of 2.4 and 4.5 with the corrugated surface exposed to both thick and thin turbulent boundary layers. Tests were conducted with the corrugations at cross-flow angles from 0 deg to 90 deg to the flow. Results show that for cross-flow angles of 30 deg or less, the pressure drag coefficients are less than the local flat-plate skin-friction coefficients and are not significantly affected by Mach number, Reynolds number, or boundary-layer thickness over the ranges investigated. For cross-flow angles greater than 30 deg, the drag coefficients increase significantly with cross-flow angle and moderately with Reynolds number. Increasing the Mach number causes a significant reduction in the pressure drag. The average and peak heating penalties due to the corrugated surface are small for cross-flow angles of 10 deg or less but are significantly higher for the larger cross-flow angles.

Sawyer, J. W.↗

Numerical simulations of supersonic flow through oscillating cascade sections

A finite difference code has been developed for modeling inviscid, unsteady supersonic flow by solution of the compressible Euler equations. The code uses a deforming grid technique to capture the motion of the airfoils and can model oscillating cascades with any arbitrary interblade phase angle. A flat plate cascade is analyzed, and results are compared with results from a small-perturbation theory. The results show very good agreement for both the unsteady pressure distributions and the integrated force predictions. The reason for using the numerical Euler code over a small-perturbation theory is the ability to model 'real' airfoils that have thickness and camber. Sample predictions are presented for a cascade of loaded airfoils and show appreciable differences in the unsteady surface pressure distributions when compared with the flat plate results.

Huff, Dennis L.↗

Unified nonlinear approach to both weak and strong-interaction problems

The numerical results are obtained for heat transfer, skin-friction, and viscous interaction induced pressure for a step-wise accelerated flat plate in hypersonic flow. In the unified approach here the results are presented for both weak and strong-interaction problems without employing any linearization scheme. With the help of the numerical method used in this work an accurate prediction of wall shear can be made for the problems with plate velocity changes of 1% or larger. The obtained results indicate that the transient contribution to the induced pressure for helium is greater than that for air.

Gupta, R. N.↗

Laser shocking of 2024 and 7075 aluminum alloys

The effect of laser generated stress waves on the microstructure, hardness, strength and stress corrosion resistance of 2024 and 7075 aluminum alloys was investigated. Pulsed CO2 and neodymium-glass lasers were used to determine the effect of wavelength and pulse duration on pressure generation and material property changes. No changes in material properties were observed with CO2 laser. The strength and hardness of 2024-T351 and the strength of 7075-T73 aluminum alloys were substantially improved by the stress wave environments generated with the neodymium-glass laser. The mechanical properties of 2024-T851 and 7075-T651 were unchanged by the laser treatment. The correlation of the laser shock data with published results of flyer plate experiments demonstrated that a threshold pressure needed to be exceeded before strengthening and hardening could occur. Peak pressures generated by the pulsed laser source were less than 7.0 GPa which was below the threshold pressure required to change the mechanical properties of 2024-T851 and 7075-T651. Corrosion studies indicated that laser shocking increased the resistance to local attack in 2024-T351 and 7075-T651.

Clauer, A. H.↗

Investigation of radiative interactions in supersonic internal flows

Analyses and numerical procedures are presented to study the radiative interactions of absorbing emitting species in chemically reacting supersonic flow in various ducts. The 2-D time dependent Navier-Stokes equations in conjunction with radiative flux equation are used to study supersonic flows undergoing finite rate chemical reaction in a hydrogen air system. The specific problem considered is the flow of premixed radiating gas between parallel plates. Specific attention was directed toward studying the radiative contribution of H2O, OH, and NO under realistic physical and flow conditions. Results are presented for the radiative flux obtained for different gases and for various combination of these gases. The problem of chemically reacting and radiating flows was solved for the flow of premixed hydrogen-air through a 10 deg compression ramp. Results demonstrate that the radiative interaction increases with an increase in pressure, temperature, amount of participating species, plate spacing, and Mach number. Most of the energy, however, is transferred by convection in the flow direction. In general the results indicate that radiation can have a significant effect on the entire flow field.

Tiwari, Surendra N.↗