At least 397 records · Page 22

Exploring the Atmosphere of Uranus with Small Next-generation Atmospheric Probe (SNAP)

In-situ atmospheric exploration of giant planets is a top priority of the planetary science community and NASA. The Galileo Probe a Jupiter made the first and only in-situ composition measurements of the atmosphere. Most importantly, the noble gas and isotopic ratio can be made only through in-situ measurements, and the Galileo Probe measurements must be followed up by similar measurements at Saturn, Uranus, and Neptune. In addition, abundances of condensable cloud-forming species are also needed to measure the vertical distribution of those molecules to provide ground-truths measurements for remote-sensing measurements. My talk will focus on the Small Next-generation Atmospheric Probe (SNAP) design developed in partnership by Hampton University and NASA Langley Research Center to enable delivery of multiple probes. Using SNAP as a reference design, I will also discuss key instrument trades and the state of the art in the atmospheric composition instruments.

Kunio Sayanagi↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Gravity Poppers: Hopping Probes for the Internal Mapping of Small Solar System Bodies

This paper presents the results of NIAC Phase I study into the feasibility of a novel mission architecture for highresolution gravity science on small Solar System bodies. The “Gravity Poppers” mission concept (see Fig. 1) consists of a swarm of small, minimalistic probes that are deployed from a mother spacecraft to the surface of a small body and which periodically and randomly hop around the surface. By tracking the ballistic sub-orbital trajectories of this hopping swarm, a very high resolution gravity field can be measured, which can then be used to answer a number of scientific questions of interest regarding the interior mass distribution of the body. This paper describes the three core focus areas of our study to demonstrate concept feasibility: (1) the design of hopping probes to be small, simple, robust, and “visible” to a distant spacecraft, (2) the tracking strategy for detecting and estimating the trajectories of a large number of ballistic probes, and (3) the algorithmic framework by which such measurements can be used to estimate the body’s gravity field. Our results suggest the ability to estimate the gravity field of a 500m asteroid beyond degree-and-order 40 through days to weeks of optical tracking of several LED-strobing probes, with a mass of only 200 g each. Collectively, this study demonstrates that the high-resolution gravity mapping of small body interiors is technically possible, economically feasible, and would enable a compelling set of science objectives aligned with NASA’s goals in planetary science, planetary defense, and future interests in resource prospecting.

McMahon, Jay↗

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill↗

Analysis of Hot-Wire Probe Ice Water Content Measurements in High Ice Water Content Conditions

During the 2022 High Ice Water Content (HIWC) Flight Campaign, ice water content (IWC) measurements were made at various locations on the NASA DC-8 Airborne Science Laboratory using the Isokinetic Probe Version 2 (IKP2), Ice Crystal Detectors (ICD), and Robust Probe. Correlations of a wing mounted ICD to IKP2 were made to determine the collision/retention efficiency of the ICD total water content (TWC) element in glaciated conditions. Similarly, correlations of a nose mounted ICD near the pitot probes were made to the IKP2 and to the wing-mounted ICD to estimate the ice concentration factor near the DC-8 pitot probes. Results from the 2022 flight campaign were compared to results from the HIWC RADAR II flight campaign in 2018. There was an apparent reduction in the ICD TWC collision/retention efficiency during the 2022 flight campaign. Although reasons for this discrepancy were explored, more analyses are needed to fully understand the causes. However, it was concluded that an estimated ice concentration factor at the nose of 2.5 was consistent between the two flight campaigns. Additionally, a correlation model was developed to relate measurements from a Nose ICD to freestream IWC as measured by the IKP2 to support IWC measurements from the 2022 Convective Processes Experiment - Cabo Verde (CPEX-CV) flight campaign.

Icing↗

Analysis of Hot-Wire Probe Ice Water Content Measurements in High Ice Water Content Conditions

During the 2022 High Ice Water Content (HIWC) Flight Campaign, ice water content (IWC) measurements were made at various locations on the NASA DC-8 Airborne Science Laboratory using the Isokinetic Probe Version 2 (IKP2), Ice Crystal Detectors (ICD), and Robust Probe. Correlations of a wing mounted ICD to IKP2 were made to determine the collision/retention efficiency of the ICD total water content (TWC) element in glaciated conditions. Similarly, correlations of a nose mounted ICD near the pitot probes were made to the IKP2 and to the wing-mounted ICD to estimate the ice concentration factor near the DC-8 pitot probes. Results from the 2022 flight campaign were compared to results from the HIWC RADAR II flight campaign in 2018. There was an apparent reduction in the ICD TWC collision/retention efficiency during the 2022 flight campaign. Although reasons for this discrepancy were explored, more analyses are needed to fully understand the causes. However, it was concluded that an estimated ice concentration factor at the nose of 2.5 was consistent between the two flight campaigns. Additionally, a correlation model was developed to relate measurements from a Nose ICD to freestream IWC as measured by the IKP2 to support IWC measurements from the 2022 Convective Processes Experiment - Cabo Verde (CPEX-CV) flight campaign.

Icing↗

Two plasma probe techniques

Annotated bibliography on two plasma probe techniques using plasma resonance probe, and Langmuir probe

LANGMUIR PROBE↗

The Future of NASA's Deep Space Network and Applications to Planetary Probe Missions

NASA's Deep Space Network (DSN) has been an invaluable tool in the world's exploration of space. It has served the space-faring community for more than 45 years. The DSN has provided a primary communication pathway for planetary probes, either through direct- to-Earth links or through intermediate radio relays. In addition, its radiometric systems are critical to probe navigation and delivery to target. Finally, the radio link can also be used for direct scientific measurement of the target body ('radio science'). This paper will examine the special challenges in supporting planetary probe missions, the future evolution of the DSN and related spacecraft technology, the advantages and disadvantages of radio relay spacecraft, and the use of the DSN radio links for navigation and scientific measurements.

Deep Space Network (DSN)↗

PROcess Based Diagnostics PROBE

Many of the aspects of the climate system that are of the greatest interest (e.g., the sensitivity of the system to external forcings) are emergent properties that arise via the complex interplay between disparate processes. This is also true for climate models most diagnostics are not a function of an isolated portion of source code, but rather are affected by multiple components and procedures. Thus any model-observation mismatch is hard to attribute to any specific piece of code or imperfection in a specific model assumption. An alternative approach is to identify diagnostics that are more closely tied to specific processes -- implying that if a mismatch is found, it should be much easier to identify and address specific algorithmic choices that will improve the simulation. However, this approach requires looking at model output and observational data in a more sophisticated way than the more traditional production of monthly or annual mean quantities. The data must instead be filtered in time and space for examples of the specific process being targeted.We are developing a data analysis environment called PROcess-Based Explorer (PROBE) that seeks to enable efficient and systematic computation of process-based diagnostics on very large sets of data. In this environment, investigators can define arbitrarily complex filters and then seamlessly perform computations in parallel on the filtered output from their model. The same analysis can be performed on additional related data sets (e.g., reanalyses) thereby enabling routine comparisons between model and observational data. PROBE also incorporates workflow technology to automatically update computed diagnostics for subsequent executions of a model. In this presentation, we will discuss the design and current status of PROBE as well as share results from some preliminary use cases.

PROBE↗

Small Next-Generation Atmospheric Probe (SNAP) Concept

We present the Small Next-Generation Atmospheric Probe (SNAP) as a secondary payload concept for future missions to giant planets. As a case study, we examine the advantages, cost and risk of adding SNAP to the future Uranus Orbiter and Probe flag-ship mission; in combination with the missions main probe, SNAP would perform atmospheric in-situ measurements at a second location.

Uranus↗

Parker Solar Probe: Four Years of Discoveries at Solar Cycle Minimum

Launched on 12 Aug. 2018, NASA’s Parker Solar Probe had completed 13 of its scheduled 24 orbits around the Sun by Nov. 2022. The mission’s primary science goal is to determine the structure and dynamics of the Sun’s coronal magnetic field, understand how the solar corona and wind are heated and accelerated, and determine what processes accelerate energetic particles. Parker Solar Probe returned a treasure trove of science data that far exceeded quality, significance, and quantity expectations, leading to a significant number of discoveries reported in nearly 700 peer-reviewed publications. The first four years of the 7-year primary mission duration have been mostly during solar minimum conditions with few major solar events. Starting with orbit 8 (i.e., 28 Apr. 2021), Parker flew through the magnetically dominated corona, i.e., sub-Alfvénic solar wind, which is one of the mission’s primary objectives. In this paper, we present an overview of the scientific advances made mainly during the first four years of the Parker Solar Probe mission, which go well beyond the three science objectives that are: (1) Trace the flow of energy that heats and accelerates the solar corona and solar wind; (2) Determine the structure and dynamics of the plasma and magnetic fields at the sources of the solar wind; and (3) Explore mechanisms that accelerate and transport energetic particles.

Sun↗

Movable RF probe eliminates need for calibration in plasma accelerators

Movable RF antenna probe in plasma accelerators continuously maps the RF field both within and beyond the accelerator. It eliminates the need for installing probes in the accelerator walls. The moving RF probe can be used to map the RF electrical field under various accelerator conditions.

Miller, D. B.↗

Vacuum probe sampler removes micron-sized particles from surfaces

Vacuum probe sampler removes micron-sized particles from sensitive surfaces, without damage to the surface. The probe has a critical orifice to ensure an optimum airflow rate that disturbs the boundary layer of air and raises bacteria from the surface into the probe with the moving air stream.

Whitfield, W. J.↗

Concept for a multifunctional oscilloscope probe

Multifunctional oscilloscope probe incorporates required electronic components so that any one of three desired functions /direct, demodulation, or low capitance/ can be switched into the oscilloscope. The probe obviates the need for the three seperate oscilloscope probes previously used in checking electronic equipment.

Stringer, E. J.↗

Dynamics of short pressure probes

Report presents practical information for incorporating particle impact protection features and average total pressure measurement into probe design while optimizing probe transient response. Computer program calculates probe response, based on Bergh-Tijdeman equation.

Englund, D. R.↗

Apollo 14 mission: Failure to achieve docking probe capture latch engagement

Six docking attempts were required in order to successfully achieve capture latch engagement during the transposition and docking phase following translunar injection. After docking, the probe and drogue were examined by the crew. Probe operation appeared normal and radial marks were noted on the drogue. During all subsequent operations, the probe operated properly.

Source record↗

Systems-level study of a nonsurvivable Jupiter turbopause probe. Volume 1: Summary

The design of a space probe to explore the atmosphere of the planet Jupiter is discussed. Five major areas were considered: (1) definition of science requirements, (2) mission evaluation, (3) definition of probe system, (4) definition of spacecraft support requirements, and (5) nonequilibrium flow field analysis for communications blackout evaluation. The overall mission and system design are emphasized. The integration of the various technologies into complete systems designs is described. Results showed that a nonsurvivable turbopause probe mission to Jupiter with adequate data return to meet the science objectives is feasible and practical.

Wiltshire, R. S.↗

Low keV electron probe analysis of silicate minerals for Mg, Al, and Si using pure-element standards

Accurate electron probe values for Mg, Al, and Si in silicate minerals may be obtained with pure-element standards. Analysis must be done at low (6 kV) accelerating potential and for best results, the average atomic number of the sample should be within about plus or minus 1 of the atomic number of the pure-element standard. This last requirement is automatically fulfilled for most common silicate minerals, as their average atomic numbers usually fall within the 11 to 15 range. Examples studied include a wet-chemically analyzed cordierite containing 17.71 weight percent Al, for which a value of 17.6 plus or minus 0.3 percent was obtained with the electron probe, and a hornblende containing 19.15 percent Si, which gave 19.0 plus or minus 0.3 percent using the probe method.

Cunningham, G. G.↗