Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

An Airborne Conical Scanning Millimeter-Wave Imaging Radiometer (CoSMIR)

An airborne Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) for high-altitude observations from the NASA Research Aircraft (ER-2) is discussed. The primary application of the CoSMIR is water vapor profile remote sensing. Four radiometers operating at 50 (three channels), 92, 150, and 183 (three channels) GHz provide spectral coverage identical to nine of the Special Sensor Microwave Imager/Sounder (SSMIS) high-frequency channels. Constant polarization-basis conical and cross-track scanning capabilities are achieved using an elevation-under-azimuth two-axis gimbals.

Piepmeier, J.↗

Application and Design of Satellite Infrared Spectral Imaging Radiometers with Uncooled Microbolometer Array Detectors

Uncooled infrared microbolometer array detectors have application for space borne spectral imaging radiometer of several types to lower size, power and cost and provide improved performance. Other advantages of eliminating cooling requirement are simplified systems, simplified satellite integration and improved reliability. A prototype microbolometer instrument for cloud observations was flown on the STS-85 space shuttle mission. Extensive data were acquired at_km resolution at four thermal infrared wavelength bands. From the 320x280 detector array both spectral and angular information can be used to advantage in cloud retrievals and has been demonstrated. An engineering model Compact Visible and Infrared Imaging Radiometer (COVIR) for small satellite missions has been developed. Application of advanced microbolometer array detectors for three axis stabilized GOES thermal imagers has been studied.

Spinhirne, James↗

TRMM Microwave Radiometer Rain Rate Estimation Method with Convective and Stratiform Discrimination

Tropical Rainfall Measuring Mission (TRMM) Microwave Imager (TMI) radiometer brightness temperature data in the 85 GHz channel (T85) reveal distinct local minima (T85min) in a regional map containing a Mesoscale Convective System (MCS). A map of surface rain rate for that region, deduced from simultaneous measurements made by the Precipitation Radar (PR) on board the TRMM satellite, reveals that these T85min, produced by scattering, correspond to local PR rain maxima. Utilizing the PR rain rate map as a guide, we have developed a TMI algorithm to retrieve convective and stratiform rain. In this algorithm, two parameters are used to classify three kinds of thunderstorms (Cbs) based on the T85 data: a) the magnitude of scattering depression deduced from local T85mi, and b) the mean horizontal gradient of T85 around such minima. Initially, the algorithm is optimized or tuned utilizing the PR and TMI data of a few MCS events. The areal distribution of light (1-10 mm/hr), moderate (10-20 mm/hr), and intense (greater than or equal to 20 mm/hr) rain rates are retrieved on the average with an accuracy of about 15%. Taking advantage of this ability of our retrieval method, one could derive the latent heat input into the atmosphere over the 760 km wide swath of the TMI radiometer in the tropics.

Prabhakara, Cuddapah↗

Global Climate Monitoring with the EOS PM-Platform's Advanced Microwave Scanning Radiometer (AMSR-E)

The Advanced Microwave Scanning 2 Radiometer (AMSR-E) is being built by NASDA to fly on NASA's PM Platform (now called Aqua) in December 2000. This is in addition to a copy of AMSR that will be launched on Japan's ADEOS-II satellite in 2001. The AMSRs improve upon the window frequency radiometer heritage of the SSM/I and SMMR instruments. Major improvements over those instruments include channels spanning the 6.9 GHz to 89 GHz frequency range, and higher spatial resolution from a 1.6 m reflector (AMSR-E) and 2.0 m reflector (ADEOS-II AMSR). The ADEOS-II AMSR also will have 50.3 and 52.8 GHz channels, providing sensitivity to lower tropospheric temperature. NASA funds an AMSR-E Science Team to provide algorithms for the routine production of a number of standard geophysical products. These products will be generated by the AMSR-E Science Investigator-led Processing System (SIPS) at the Global Hydrology Resource Center (GHRC) in Huntsville, Alabama. While there is a separate NASDA-sponsored activity to develop algorithms and produce products from AMSR, as well as a Joint (NASDA-NASA) AMSR Science Team 3 activity, here I will review only the AMSR-E Team's algorithms and how they benefit from the new capabilities that AMSR-E will provide. The US Team's products will be archived at the National Snow and Ice Data Center (NSIDC).

Spencer, Roy W.↗

Solar-Reflectance-Based Calibration of Spectral Radiometers

A method by which to calibrate a spectral radiometer using the sun as the illumination source is discussed. Solar-based calibrations eliminate several uncertainties associated with applying a lamp-based calibration to field measurements. The procedure requires only a calibrated reflectance panel, relatively low aerosol optical depth, and measurements of atmospheric transmittance. Further, a solar-reflectance-based calibration (SRBC), by eliminating the need for extraterrestrial irradiance spectra, reduces calibration uncertainty to approximately 2.2% across the solar-reflective spectrum, significantly reducing uncertainty in measurements used to deduce the optical properties of a system illuminated by the sun (e.g., sky radiance). The procedure is very suitable for on-site calibration of long-term field instruments, thereby reducing the logistics and costs associated with transporting a radiometer to a calibration facility.

Cattrall, Christopher↗

Combined Radiometer-Radar Microphysical Profile Estimations with Emphasis on High Frequency Brightness Temperature Observations

Information about the vertical microphysical cloud structure is useful in many modeling and predictive practices. Radiometers and radars are used to observe hydrometeor properties. This paper describes an iterative retrieval algorithm that combines the use of airborne active and wideband (10 to 340 GHz) passive observations to estimate the vertical content and particle size distributions of liquid and frozen hydrometeors. The physically-based retrieval algorithm relies on the high frequencies (greater than 89 GHz) to provide details on the frozen hydrometeors. Neglecting the high frequencies yielded acceptable estimates of the liquid profiles, but the ice profiles were poorly retrieved. Airborne radar and radiometer observations from the third Convection and Moisture EXperiment (CAMEX-3) were used in the retrieval algorithm as constraints. Nadir profiles were estimated for a minute each of flight time (approximately 12.5 km along track) from an anvil, convection, and quasi- stratiform rain. The complex structure of the frozen hydrometeors required the most iterations for convergence for the anvil cloud type. The wideband observations were found to more than double the estimated frozen hydrometeor content as compared to retrievals using only 90-GHz and below. The convective and quasi-stratiform quickly reached convergence (minimized difference between observations and calculations using the estimated profiles). A qualitative validation using coincident in situ CAMEX-3 observations shows that the retrieved particle size distributions are well corroborated with independent measurements.

Gail Skofronick-Jackson↗

Numerical Filtering of Spurious Transients in a Satellite Scanning Radiometer: Application to CERES

The Clouds and Earth Radiant Energy System (CERES) scanning, radiometer was designed to provide high accuracy measurements of the radiances from the earth. Calibration testing of the instruments showed the presence of all undesired slow transient in the measurements of all channels at 1% to 2% of the signal. Analysis of the data showed that the transient consists of a single linear mode. The characteristic time of this mode is 0.3 to 0.4 s and is much greater than that the 8-10-ms response time of the detector, so that it is well separated from the detector response. A numerical filter was designed for the removal of this transient from the measurements. Results show no trace remaining of the transient after application of the numerical filter. The characterization of the slow mode on the basis of ground calibration data is discussed and flight results are shown for the CERES instruments aboard the Tropical Rainfall Measurement Mission and Terra spacecraft. The primary influence of the slow mode is in the calibration of the instrument and the in-flight validation of the calibration. This method may be applicable to other radiometers that are striving for high accuracy and encounter a slow spurious mode regardless of the underlying physics.

Smith, G. Louis↗

Comparative Analysis of Radiometer Systems Using Non-Stationary Processes

Radiometers require periodic calibration to correct for instabilities in the receiver response. Various calibration techniques exist that minimize the effect of instabilities in the receivers. The optimal technique depends upon many parameters. Some parameters are constrained by the particular application and others can be chosen in the system design. For example, the measurement uncertainty may be reduced to the limits of the resolution of the measurement (sensitivity) if periodic absolute calibration can be performed with sufficient frequency. However if the period between calibrations is long, a reference-differencing technique, i.e. Dicke-type design, can yield better performance. The measurement uncertainty not only depends upon the detection scheme but also on the number of pixels between calibrations, the integration time per pixel, integration time per calibration reference measurement, calibration reference temperature, and the brightness temperature of what is being measured. The best scheme for reducing the measurement uncertainty also depends, in large part, on the stability of the receiver electronics. In this presentation a framework for evaluating calibration schemes for a wide range of system architectures is presented. Two methods for treating receiver non-stationarity are compared with radiometer measurements.

Racette, Paul↗

The Airborne Conical Scanning Millimeter-Wave Imaging Radiometer (CoSMIR)

Results of the first science flight of the airborne Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) for high-altitude observations from the NASA ER-2 is discussed. Imagery collected from the flight demonstrates CoSMIR's unique conical/cross-track imaging mode and provides comparison of CoSMIR measurements to those of the Special Sensor Microwave/Temperature-2 (SSM/T-2) satellite radiometer.

Piepmeier, J. R.↗

Calibration Design and Assessment of the Airborne Conical Scanning Millimeterwave Imaging Radiometer (CoSMIR)

The airborne Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) will provide measurements useful for atmospheric studies and satellite calibration and validation (cal/val). Designed to match the tropospheric sounding channels of the Defense Meteorological Satellite Program QMSP) Special Sensor Microwave Imager/Sounder (SSMIS), the CoSMIR consists of four radiometers operating at 50-54 (3 channels - 50.3, 52.8, and 53.6), 91.655 (dual polarization), 150.0, and 193.31 (3 channels 11, 13, and 16.6) GHz. The design of CoSMIR was primarily driven by its intended initial use as an SSMIS cal/val sensor. In particular, three design features were directly affected by this requirement: frequency planning, calibration target design, and the mechanical gimbals. An initial calibration assessment of CoSMIR was performed to determine any needed improvements. We used a combination of laboratory and field measurements to do this. Laboratory measurements included comparisons to a liquid nitrogen standard, IF amplifier and diode linearity tests, LO leakage and reflection testing, and antenna to calibration target coupling tests. Results of these tests will be reported. We also performed a satellite underflight under DM SP F-15 and have compared CoSMIR imagery to SSM/T-2 and SSM/I imagery. Additional information is included in the original extended abstract.

Piepmeier, J. R.↗

The Use of Transfer Radiometers in Validating the Visible through Shortwave Infrared Calibrations of Radiance Sources Used by Instruments in NASA's Earth Observing System

The detection and study of climate change over a time frame of decades requires successive generations of satellite, airborne, and ground-based instrumentation carefully calibrated against a common radiance scale. In NASA s Earth Observing System (EOS) program, the pre-launch radiometric calibration of these instruments in the wavelength region from 400 nm to 2500 nm is accomplished using internally illuminated integrating spheres and diffuse reflectance panels illuminated by irradiance standard lamps. Since 1995, the EOS Calibration Program operating within the EOS Project Science Office (PSO) has enlisted the expertise of national standards laboratories and government and university metrology laboratories in an effort to validate the radiance scales assigned to sphere and panel radiance sources by EOS instrument calibration facilities. This state-of-the-art program has been accomplished using ultra-stable transfer radiometers independently calibrated by the above participating institutions. In ten comparisons since February 1995, the agreement between the radiance measurements of the transfer radiometers is plus or minus 1.80% at 411 nm, plus or minus 1.31% at 552.5 nm, plus or minus 1.32% at 868.0 nm, plus or minus 2.54% at 1622nm, and plus or minus 2.81% at 2200nm (sigma =1).

Butler, James J.↗

Design Study of a Synthetic Thinned Aperture Radiometer for Hurricane Impact Prediction

The principle accomplishments involve a conceptual design of an airborne Hurricane Imaging (microwave) Radiometer (HiRad) instrument for use in operational hurricane surveillance. The basis of the HiRad design is the Stepped Frequency Microwave Radiometer (SFMR) that has successfully measured surface wind speed and rain rate in hurricanes from the NOAA Hurricane Research Division s P-3 aircraft. Unlike the SFMR that views only at nadir, the HiRad provides wide-swath measurements between +/- 45 deg. in incidence angle with a spot-beam spatial resolution of approximately 1-3 km. The system operates at four equally spaced frequency channels that cover a range between 4 GHz and 6 GHz. The final report consists of two parts. Part 1 is a reprint of a conference proceeding presented at the 2002 International Geoscience and Remote Sensing Symposium and authored by the principle members of the HiRad design team. Part 2 is a summary of the MMIC receiver design developed to support the HiRad sensor.

Ruf, Christopher S.↗

Radiant Temperature Nulling Radiometer

A self-calibrating nulling radiometer for non-contact temperature measurement of an object, such as a body of water, employs a black body source as a temperature reference, an optomechanical mechanism, e.g., a chopper, to switch back and forth between measuring the temperature of the black body source and that of a test source, and an infrared detection technique. The radiometer functions by measuring radiance of both the test and the reference black body sources; adjusting the temperature of the reference black body so that its radiance is equivalent to the test source; and, measuring the temperature of the reference black body at this point using a precision contact-type temperature sensor, to determine the radiative temperature of the test source. The radiation from both sources is detected by an infrared detector that converts the detected radiation to an electrical signal that is fed with a chopper reference signal to an error signal generator, such as a synchronous detector, that creates a precision rectified signal that is approximately proportional to the difference between the temperature of the reference black body and that of the test infrared source. This error signal is then used in a feedback loop to adjust the reference black body temperature until it equals that of the test source, at which point the error signal is nulled to zero. The chopper mechanism operates at one or more Hertz allowing minimization of l/f noise. It also provides pure chopping between the black body and the test source and allows continuous measurements.

Robert Ryan↗

Nulling Infrared Radiometer for Measuring Temperature

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 ?m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied.

Ryan, Robert↗

Nulling Infrared Radiometer for Measuring Temperature

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied.

Ryan, Robert↗

Development of a Miniature L-band Radiometer for Education Outreach in Remote Sensing

Work performed under this grant developed a 1.4-Mhz radiometer for use in soil moisture remote sensing from space. The resulting instrument was integrated onto HuskySat. HuskySat is a 30-kg nanosatellite built under sponsorship from the Air Force Research Laboratory and NASA. This report consists of the interface document for the radiometer (the Science Payload of HuskySat) as detailed in the vehicle design report.

King, Lyon B.↗

Airborne Sunphotometer and Solar Spectral Flux Radiometer Measurements During INTEX/ITCT 2004

During the period 12 July - 8 August 2004, the NASA Ames 14-channel Airborne Tracking Sunphotometer (MTS-14) and Solar Spectral Flux Radiometer (SSFR) were operated aboard a Jetstream 31 (J31) aircraft and acquired measurements during nineteen science flights (approx. 53 flight hours) over the Gulf of Maine in support of the INTEX-NA (INtercontinental chemical Transport Experiment-North America) and ITCT (Intercontinental Transport and Chemical Transformation of anthropogenic pollution) field studies. In this paper, we will present results from analyses of those data sets. AATS-14 measures the direct solar beam transmission at fourteen discrete wavelengths (354-2138 nm), and provides instantaneous measurements of aerosol optical depth (AOD) spectra and water vapor column content, in addition to vertical profiles of aerosol extinction and water vapor density during suitable aircraft ascents and descents. SSFR consists of separate nadir and zenith viewing hemispheric FOV sensors that yield measurements of up- and downwelling solar irradiance at a spectral resolution of approx. 8-12 nm over the wavelength range 300-1700 nm. The objectives of the J31-based measurements during INTEX/ITCT were to provide AOD data for the evaluation of MODIS (MODerate-resolution Imaging Spectroradiometer) and MISR (Multi-angle Imaging Spectro-Radiometer) AOD retrievals, quantify sea surface spectral albedo (which can contribute the largest uncertainty to satellite aerosol retrievals for low aerosol loading), test closure (consistency) among suborbital results, test chemical-transport models using AOD profiles, and assess regional radiative forcing by combining satellite and suborbital results. Specific J31 flight patterns were designed to achieve these objectives, and they included a mixture of vertical profiles (spiral and ramped ascents and descents) and constant altitude horizontal transects at a variety of altitudes. Additional information is included in the original extended abstract.

Russell, P. B.↗

TOPEX/Poseidon Microwave Radiometer (TMR): 1. Instrument Description and Antenna Temperature Calibration

The TOPEX/Poseidon Microwave Radiometer (TMR) is a 3-frequency radiometer flown on the TOPEX/Poseidon (T/P) satellite in low Earth orbit. It operates at 18, 21 and 37 GHz in a nadir only viewing direction which is co-aligned with the T/P radar altimeters. TMR monitors and corrects for the electrical path delay of the altimeter radar signal due to water vapor and non-precipitating liquid water in the atmosphere. This paper describes the TMR instrument and the radiometric instrument calibration required to derive antenna temperature (T_A) from the raw digital data. T_A precision of 0.4 K is predicted on orbit in all expected thermal environments. T_A accuracy of 0.5-0.6 K is expected following a post-launch field calibration campaign. When uncertainties related to antenna sidelobe corrections are included, this T_A accuracy yields a brightness temperature accuracy of 0.7- 0.8 K...

Ruf, C. S.↗