Search NASA⌕ Search

SEARCH · Search NASA

Results for “reliability engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Validation of IMEP on Alcator C-Mod and JET-ILW ELMy H-mode plasmas

Abstract The recently developed integrated model based on engineering parameters (IMEP) (Luda et al 2020 Nucl. Fusion 61 126048; Luda et al 2021 Nucl. Fusion 60 036023), so far validated on ASDEX Upgrade, has been tested on a database of 3 Alcator C-Mod and 55 JET-ILW ELMy (type I) H-mode stationary phases. The empirical pedestal transport model included in IMEP, consisting now of imposing a fixed value of R < ∇ T e > / T e , t o p = − 82.5 , allows an accurate prediction of the pedestal top temperature (when the pedestal top density is fixed to the experimental measurements) across these three machines with different sizes, when the pedestal is peeling–ballooning (PB) limited. Cases far from the ideal PB boundary, corresponding to high edge Spitzer resistivity, are instead strongly overpredicted by IMEP. A comparison between the predictions of Europed and IMEP for a subset of JET-ILW cases shows that IMEP can more accurately reproduce the experimental pedestal width. This allows IMEP to better capture profile effects on the pedestal stability, and therefore to correctly describe the negative effect of fueling on the pedestal pressure for PB limited cases. A strong correlation between the separatrix density and the fueling rate has been identified for a subset of JET-ILW cases, when taking into account different divertor configurations. Overall, these promising results encourage further developments of integrated models to obtain reliable predictions of pedestal and global confinement using only engineering parameters for present and future machines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A review of human-system interface design issues observed during analog-to-digital and digital-to-digital migrations in U.S. nuclear power plants - 312

The United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program is developing a scientific basis through targeted research and development (R and D) to support the U.S. nuclear power plant (NPP) fleet in extending their existing licensing period and ensuring their long-term reliability, productivity, safety, and security. Over the last several years, human factors engineering (HFE) professionals at the Idaho National Laboratory (INL) have supported the LWRS Advanced Instrumentation, Information, and Control (II and C) System Technologies pathway across several U.S. commercial NPPs in analog-to-digital migrations (i.e., turbine control systems) and digital-to-digital migrations (i.e., Safety Parameter Display System). These efforts have included in-depth human factors evaluation of proposed human-system interface (HSI) design concepts against established U.S. Nuclear Regulatory Commission (NRC) design guidelines from NUREG-0700, Rev 2 to inform subsequent HSI design prior to transitioning into Verification and Validation. This paper discusses some of the overarching design issues observed from these past HFE evaluations. In addition, this work presents some observed challenges such as common tradeoffs utilities are likely to face when introducing new HSI technologies into NPP hybrid control rooms. The primary purpose of this work is to distill these observed design issues into general HSI design guidance that industry can use in early stages of HSI design. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Artificial Intelligence for Power Electronics in Electric Vehicles: Challenges and Opportunities

We report progress in the field of power electronics within electric vehicles has generally been driven by conventional engineering design principles and experiential learning. Power electronics is inherently a multidomain field where semiconductor physics and electrical, thermal, and mechanical design knowledge converge to achieve a practical realization of desired targets in the form of conversion efficiency, power density, and reliability. Due to the promising nature of artificial intelligence in delivering rapid results, engineers are starting to explore the ways in which it can contribute to making power electronics more compact and reliable. Here, we conduct a brief review of the foray of artificial intelligence in three distinct subtechnologies within a power electronics system in the context of electric vehicles: semiconductor devices, power electronics module design and prognostics, and thermal management design. The intent is not to report an exhaustive literature review, but to identify the state of the art and opportunities for artificial intelligence to play a meaningful role in power electronics design from a mechanical and thermal standpoint, as well as to discuss a few promising future research directions.

33 ADVANCED PROPULSION SYSTEMS↗

Missile Captive Carry Monitoring using a Capacitive MEMS Accelerometer

Military missiles are exposed to many sources of mechanical vibration that can affect system reliability, safety, and mission effectiveness. One of the most significant exposures to vibration occurs when the missile is being carried by an aviation platform, which is a condition known as captive carry. If the duration of captive carry exposure could be recorded during the missile’s service life, several advantages could be realized. Missiles that have been exposed to durations outside the design envelop could be flagged or screened for maintenance or inspection; lightly exposed missiles could be selected for critical mission applications; and missile allocation to missions could be based on prior use to avoid overuse. The U. S. Army Aviation and Missile Research Development and Engineering Center (AMRDEC) has been developing health monitoring systems to assess and improve reliability of missiles during storage and field exposures. Under the direction of AMRDEC staff, engineers at the Pacific Northwest National Laboratory have developed a Captive Carry Health Monitor (CCHM) for the HELLFIRE II missile. The CCHM is an embedded usage monitoring device installed on the outer skin of the HELLFIRE II missile to record the cumulative hours the host missile has been in captive carry mode and thereby assess the overall health of the missile. This paper provides an overview of the CCHM electrical and package design, describes field testing and data analysis techniques used to identify captive carry, and discusses the potential application of missile health and usage data for real-time reliability analysis and fleet management.

47 OTHER INSTRUMENTATION↗

Application of Robotics in Decommissioning and Decontamination - 12536

Decommissioning and dismantling of nuclear facilities is a significant challenge worldwide and one which is growing in size as more plants reach the end of their operational lives. The strategy chosen for individual projects varies from the hands-on approach with significant manual intervention using traditional demolition equipment at one extreme to bespoke highly engineered robotic solutions at the other. The degree of manual intervention is limited by the hazards and risks involved, and in some plants are unacceptable. Robotic remote engineering is often viewed as more expensive and less reliable than manual approaches, with significant lead times and capital expenditure. However, advances in robotics and automation in other industries offer potential benefits for future decommissioning activities, with the high probability of reducing worker exposure and other safety risks as well as reducing the schedule and costs required to complete these activities. Some nuclear decommissioning tasks and facility environments are so hazardous that they can only be accomplished by exclusive use of robotic and remote intervention. Less hazardous tasks can be accomplished by manual intervention and the use of PPE. However, PPE greatly decreases worker productivity and still exposes the worker to both risk and dose making remote operation preferable to achieve ALARP. Before remote operations can be widely accepted and deployed, there are some economic and technological challenges that must be addressed. These challenges will require long term investment commitments in order for technology to be: - Specifically developed for nuclear applications; - At a sufficient TRL for practical deployment; - Readily available as a COTS. Tremendous opportunities exist to reduce cost and schedule and improve safety in D and D activities through the use of robotic and/or tele-operated systems. - Increasing the level of remote intervention reduces the risk and dose to an operator. Better environmental information identifies hazards, which can be assessed, managed and mitigated. - Tele-autonomous control in a congested unstructured environment is more reliable compared to a human operator. Advances in Human Machine Interfaces contribute to reliability and task optimization. Use of standardized dexterous manipulators and COTS, including standardized communication protocols reduces project time scales. - The technologies identified, if developed to a sufficient TRL would all contribute to cost reductions. Additionally, optimizing a project's position on a Remote Intervention Scale, a Bespoke Equipment Scale and a Tele-autonomy Scale would provide cost reductions from the start of a project. Of the technologies identified, tele-autonomy is arguably the most significant, because this would provide a fundamental positive change for robotic control in the nuclear industry. The challenge for technology developers is to develop versatile robotic technology that can be economically deployed to a wide range of future D and D projects and industrial sectors. The challenge for facility owners and project managers is to partner with the developers to provide accurate systems requirements and an open and receptive environment for testing and deployment. To facilitate this development and deployment effort, the NNL and DOE have initiated discussions to explore a collaborative R and D program that would accelerate development and support the optimum utilization of resources. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

R&D to Ensure a Scientific Basis for Qualification Tests and Standards (Final Report: FY19-FY22)

This is the final technical report for the FY19-FY21 research program "R&D to Ensure a Scientific Basis for Qualification Tests and Standards." This research was performed because project return on investment in a photovoltaic (PV) system depends increasingly on maintaining high energy yields, and the system lifetime is a major factor in levelized cost of electricity (LCOE). Thus, the rate of PV deployment and the success of these assets depends upon reliable long-term power generation. This program advances PV module reliability of commercial products through identification of reliability needs, characterization that provides scientific understanding of targeted degradation mechanisms, and translation of those data into practical and predictive test protocols and standards. This report describes program scope, results, milestones, and accomplishments over the three-year period of performance.

14 SOLAR ENERGY↗

Efficient Reliability Analysis using Generalized Multifidelity Modeling and Explainable Active Learning

To assess the reliability of critical technologies like nuclear plants and infrastructure systems and improve the robustness of design, engineers have to quantify the uncertainties surrounding the system behavior accurately. However, the complexity of the problem can make standard reliability analysis algorithms prohibitively expensive, primarily due to the high computational cost of estimating the system response at each iteration. This cost can be greatly reduced by using multi-fidelity modeling and machine learning to build a surrogate model to replace the expensive response function. We propose a general and robust method for building surrogates from multiple Low Fidelity (LF) models coupled with machine learning to retain accuracy. Our framework first constructs “Corrected Low Fidelity models” (CLFs) by coupling a High Fidelity (HF) model inferred Gaussian Process correction term with each of the LF models. It then uses the correction terms to assign model probabilities to each of these CLFs in an explainable way before using them to assemble the final surrogate. No assumptions are made about the type of the LF models or their correlation with the HF model. The proposed surrogate modeling framework is used within the subset simulation algorithm (a variance-reduced MCMC-based reliability analysis algorithm) for enhanced efficiency. Additionally, an active learning step is added to the algorithm to adaptively decide when the surrogate is not sufficiently accurate, at which point the HF model is called and used to refine the surrogate. Through a frame buckling example, our method is shown to be highly efficient at reducing the expensive HF model calls while accurately estimating the failure probability.

97 MATHEMATICS AND COMPUTING↗

CIE Analysis Process for Engineered Systems

"CIE Analysis Process for Engineered Systems" outlines a comprehensive methodology for integrating Cyber-Informed Engineering (CIE) principles into both new and existing engineered systems. Sponsored by the U.S. Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (DOE CESER), the process aims to achieve cyber-informed decisions by producing functional security requirements for new systems and retrofitting existing systems to mitigate digital risks. The document details a step-by-step approach, including mission and function definition, digital asset awareness, consequence analysis, and mitigation analysis. It emphasizes the importance of documenting mechanical, electrical, programmable, and network components to protect system functions and provides examples and considerations for each step. The ultimate goal is to ensure that engineered systems remain resilient against cyber threats, maintaining safety, performance, and reliability.

42 - ENGINEERING↗

Ensuring operator reliability in digital control rooms - 102

The U.S. fleet of nuclear power plants is aging, and efforts are being made to modernize instrumentation and control systems including integration of digital human-machine interfaces (HMIs) into the control room. Automation and control technologies have advanced since original systems were installed in the plants. This presents unique opportunities and challenges in ensuring the replacements are a benefit to the operators and the overall safe and reliable operation of the plant. We discuss trends we have observed from assisting utilities in their modernization efforts. Automation and evolving control rooms come with their own host of problems that existing human factors and engineering methods fail to capture. Traditional approaches are analytical approaches to ensuring reliability. Here we discuss some of the shortfalls of these traditional approaches as plants become increasingly more complex. We suggest that ensuring reliability for modernized and next generation control room will require expanding the scope of what was traditionally considered human factors as well as exploring novel approaches and methodologies for dealing with complexity and rapidly advancing technology. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Masters Thesis- Criticality Alarm System Design Guide with Accompanying Alarm System Development for the Radioisotope Production Laboratory in Richland, Washington

A detailed instructional manual was created to guide criticality safety engineers through the process of designing a criticality alarm system (CAS) for Department of Energy (DOE) hazard class 1 and 2 facilities. Regulatory and technical requirements were both addressed. A list of design tasks and technical subtasks are thoroughly analyzed to provide concise direction for how to complete the analysis. An example of the application of the design methodology, the Criticality Alarm System developed for the Radioisotope Production Laboratory (RPL) of Richland, Washington is also included. The analysis for RPL utilizes the Monte Carlo code MCNP5 for establishing detector coverage in the facility. Significant improvements to the existing CAS were made that increase the reliability, transparency, and coverage of the system.

42 ENGINEERING↗

Exploring the potential of hydrogen in decarbonizing China's light-duty vehicle market

The Chinese government has pledged to achieve overall carbon neutrality by 2060. Currently, the transportation sector contributes to about 10% of total greenhouse gas (GHG) emissions in China. Hence, China has created a well-defined energy vehicle development strategy to reduce GHG emissions from the transportation sector, further expanding into hydrogen vehicle technologies. In this study, the Transportation Energy Analysis Model (TEAM) investigates the potential of hydrogen internal combustion engine vehicles (H2- ICEVs) and fuel cell vehicles (FCEVs) as a reliable pathway towards the government's aspiration of carbon neutrality in the transportation sector. According to TEAM, by adopting FCEVs and H2-ICEVs in the vehicle market, hydrogen demand could reach 25% of the total light-duty transportation energy demand in 2050. Consequently, this will lead to an annual reduction of more than 35 million tons GHG compared to only counting on the electrification pathway in the decarbonization task. Besides, FCEVs would take longer to penetrate the light-duty vehicle market compared to H2-ICEVs, as the current fuel cell technology still requires much improvement to attain a competitive vehicle cost of production.

Life cycle analysis↗

Upgrades of edge, divertor and scrape-off layer diagnostics of W7-X for OP1.2

In this work, Wendelstein 7-X (W7-X) is the world’s largest superconducting nuclear fusion experiment of the optimized stellarator type. In the first Operation Phase (OP1.1) helium and hydrogen plasmas were studied in limiter configuration. The heating energy was limited to 4 MJ and the main purpose of that campaign was the integral commissioning of the machine and diagnostics, which was achieved very successfully. Already from the beginning a comprehensive set of diagnostics was available to study the plasma. On the path towards high-power, high-performance plasmas, W7-X will be stepwise upgraded from an inertially cooled (OP1.2, limited to 80 MJ) to an actively cooled island divertor (OP2, 10 MW steady-state plasma operation). The machine is prepared for OP1.2 with 10 inertially cooled divertor units, and the experimental campaign has started recently.The paper describes a subset of diagnostics which will be available for OP1.2 to study the plasma edge, divertor and scrape-off layer physics including those already available for OP1.1, plus modifications, upgrades and new systems. In conclusion, the focus of this summary will be on technical and engineering aspects, like feasibility and assembly but also on reliability, thermal loads and shielding against magnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Factors controlling injection-induced rupture of intersecting faults during geological sequestration of CO 2

This study addresses coupled multiphase fluid flow and geomechanics effects on potential fault activation associated with subsurface CO 2 injection around intersecting faults. An enhanced fault-representation model is used to capture geomechanical responses of two intersecting faults with finite length during CO 2 injection. The faults are embedded in a strike-slip stress regime of a caprock-reservoir-basement system with the faults represented by zero-thickness interfaces with adjacent finite-thickness damage zones. A sensitivity analysis is conducted to study the effect of fault permeability, slip-weakening behavior, well location relative to the orientation of faults, and well placement (the number and location of injection wells). Five metrics (pressure, CO 2 plume, shear state on the fault, as well as shear displacement and stress path at selected fault monitoring points) are selected to assess CO 2 migration and reactivation of intersecting faults. The results show that induced ruptures are favored by low permeability faults due to high pressure buildup and by slip-weakening behavior resulting from fault strength reduction. The location of one injection well relative to fault orientation determines the magnitude of changes in effective normal stress and shear stress, affecting the location of induced ruptures. Well placement (two injection wells used in the paper) dominates pressure diffusion around the intersection and tips of faults. This redistributes changes in effective normal stress caused by each injection well, influencing the spatial distribution of ruptures along faults. A larger injection volume induces far-field ruptures that are controlled by stress transfer within the injection layer. The findings presented here can provide valuable insights into engineering operations for a long-term, safe, and reliable geologic CO 2 storage.

Fault permeability↗

Engineering aspects of microwave diagnostics in ITER

Microwave diagnostics have potential to provide localized measurement of the electron density (ne) and temperature (Te) with good spatial (a few cm) and temporal (< 1 ms) resolutions through all phases of ITER. Development of these diagnostics is a major challenge because of severe environment, strict engineering requirements, safety issues and the need for high reliability in the measurements. Most of the diagnostic components that are placed in a high radiation environment are expected to operate in this environment for a period at least until the next planned maintenance session. This paper will cover the conceptual design of microwave diagnostics and their interface with vacuum vessel and port plugs. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Requirements Document for the Redesign of the DIM-based Diagnostics Transport and Handling System at the National Ignition Facility (NIF)

The National Ignition Facility (NIF, Figure 1) is the world’s leading user research facility for inertial confinement fusion. Diagnostic instruments that collect data from the experiment shots are transported around the facility using a series of disjointed, suboptimal transport and handling (T&H) subsystems that compromise user efficiency and ergonomics. Significant time savings and improvements to the diagnostic exchange process could be realized by designing a new transport and handling system that minimizes the hand-offs between T&H subsystems, reduces operator hassle and ergonomic strain, and improves the long-term maintainability of the system. In contrast to the current system – which employs several manually-operated carts and containers to transport the diagnostic, dock it to its destination, and install it – the new diagnostic transporter integrates the contamination container with the transport cart and provides a dynamic range of adjustability to interface with its destination. This single transporter has the requisite maneuverability, height adjustability, and fine adjustment capabilities without any rigging transactions to support contaminated diagnostic transport and handling at the alignment station and Equatorial and Polar DIMs. A remote-controlled user interface device allows operators a more hands-off experience that reduces ergonomic strain and improves safety. Assuming the cost is not prohibitive, diagnostic storage will be accomplished by simply stowing the transporter in its lowest position in the designated area of NIF. This concept for a new diagnostic transport and handling system would be better aligned with the core values of NIF: safety, quality, and reliability.

42 ENGINEERING↗