Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

4D-STEM of Beam-Sensitive Materials

We report that a scanning electron nanobeam diffraction, or 4D-STEM (four-dimensional scanning transmission electron microscopy), is a flexible and powerful approach to elucidate structure from "soft" materials that are challenging to image in the transmission electron microscope because their structure is easily damaged by the electron beam. In a 4D-STEM experiment, a converged electron beam is scanned across the sample, and a pixelated camera records a diffraction pattern at each scan position. This four-dimensional data set can be mined for various analyses, producing maps of local crystal orientation, structural distortions, crystallinity, or different structural classes. Holding the sample at cryogenic temperatures minimizes diffusion of radicals and the resulting damage and disorder caused by the electron beam. The total fluence of incident electrons can easily be controlled during 4D-STEM experiments by careful use of the beam blanker, steering of the localized electron dose, and by minimizing the fluence in the convergent beam thus minimizing beam damage. This technique can be applied to both organic and inorganic materials that are known to be beam-sensitive; they can be highly crystalline, semicrystalline, mixed phase, or amorphous. One common example is the case for many organic materials that have a π-π stacking of polymer chains or rings on the order of 3.4-4.2 Å separation. If these chains or rings are aligned in some regions, they will produce distinct diffraction spots (as would other crystalline spacings in this range), though they may be weak or diffuse for disordered or weakly scattering materials. We can reconstruct the orientation of the π-π stacking, the degree of π-π stacking in the sample, and the domain size of the aligned regions. This Account summarizes illumination conditions and experimental parameters for 4D-STEM experiments with the goal of producing images of structural features for materials that are beam-sensitive. We will discuss experimental parameters including sample cooling, probe size and shape, fluence, and cameras. 4D-STEM has been applied to a variety of materials, not only as an advanced technique for model systems, but as a technique for the beginning microscopist to answer materials science questions. It is noteworthy that the experimental data acquisition does not require an aberration-corrected TEM but can be produced on a variety of instruments with the right attention to experimental parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved uranium isotopic ratio determinations for the liquid sampling-atmospheric pressure glow discharge orbitrap mass spectrometer by use of moving average processing

The liquid sampling-atmospheric pressure glow discharge (LS-APGD) is a versatile combined atomic and molecular (CAM) ionization source capable of ionizing elemental species, small polar compounds, low-polarity polycyclic aromatic hydrocarbons, and proteins. While the LS-APGD has been proven capable of determining the 235U/238U isotope ratio in enriched and natural uranium, recent efforts have strived to reduce the analysis time of individual measurements by employing higher-order data processing techniques, specifically, moving average methods. Additionally, the use of a moving average (of data windows of various widths) improves the precision of the ratio measurements and reduces the number of scans needed to be collected to generate high-precision results. Additionally, use of the moving average minimizes the quantity of sample that needs to be analyzed while reducing the measurement time. These reductions have allowed isotope ratio (IR) determinations to be made using injections instead of direct infusion of the analyte. For example, employing a 40-point window width in the moving average to direct infusion data reduced the percent relative standard deviation (% RSD) of the 235U/238U values from 3.4% to 0.5%. For the injection of a 100 μL aliquot, the % RSD was reduced from 5.3% to 0.7%.

74 ATOMIC AND MOLECULAR PHYSICS↗

The use of synchrotron X-ray fluorescent imaging to study distribution and content of elements in chemically fixed single cells: a case study using mouse pancreatic beta-cells

Synchrotron X-ray fluorescence microscopy (SXRF) presents a valuable opportunity to study the metallome of single cells because it simultaneously provides high-resolution subcellular distribution and quantitative cellular content of multiple elements. Different sample preparation techniques have been used to preserve cells for observations with SXRF, with a goal to maintain fidelity of the cellular metallome. In this case study, mouse pancreatic beta-cells have been preserved with optimized chemical fixation. We show that cell-to-cell variability is normal in the metallome of beta-cells due to heterogeneity and should be considered when interpreting SXRF data. Additionally, we determined the impact of several immunofluorescence (IF) protocols on metal distribution and quantification in chemically fixed beta-cells and found that the metallome of beta-cells was not well preserved for quantitative analysis. However, zinc and iron qualitative analysis could be performed after IF with certain limitations. To help minimize metal loss using samples that require IF, we describe a novel IF protocol that can be used with chemically fixed cells after the completion of SXRF.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization Techniques for TRU Waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory - 19610

Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical laboratory (AL) at the INL Materials and Fuels Complex (MFC) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste as Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RHTRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization of RHTRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all Acceptable Knowledge (AK) documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Flux Maximization from a DD Neutron Generator

The University of Sharjah recently acquired a model DD-109.4M neutron generator from Adelphi Technology. The generator is moderated and has three neutron ports which are capable of providing fast and thermal neutrons. The neutron ports are plugged with polyethylene layers of different thickness in order to control the neutron flux at different regions in the port. Neutron Activation Analysis (NAA) is an important analysis technique to determine the amounts of isotopes in a sample at different concentrations. For many isotopes the ability to precisely determine their concentrations is enhanced by utilizing thermal neutrons in the activation process; where the capture cross section is greatest. It is thus important to subject the sample to the maximum thermal flux in order to minimize the time required to activate the sample and consequently extend the lifetime of the neutron generator. A detailed MCNP model of the neutron generator has been developed for the purpose of determining the moderator thickness required to maximize the thermal neutron flux in the neutron port. The maximization of the neutron flux must therefore take into account both the forward and backscattered neutrons reaching the sample. Also provided in this work is a mapping of the thermal flux at different moderator thicknesses in order to study the variation of the flux over the area of the sample. The developed model will be used as the basis for optimizing experiments and predicting their results. A study was performed to determine the moderator thickness needed to maximize the thermal neutron flux that can be obtained from a DD neutron generator. This has a significant role in the efficient utilization of the neutron generator. The maximum thermal neutron flux was found at approximately a 3.2 cm moderator thickness. The thermal neutron flux is resulting from both the directly moderated neutrons and the backscattered neutrons from the surrounding polyethylene. The results obtained in this work will be verified experimentally by irradiating samples at different moderator thickness and performing a neutron activation analysis for these samples. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

A new technique for Auger analysis of surface species subject to electron-induced desorption.

A method is presented to observe surface species subject to electron-induced desorption by Auger electron spectroscopy. The surface to be examined is moved under the electron beam at constant velocity, establishing a time-independent condition and eliminating the time response of the electron spectrometer as a limiting factor. The dependence of the Auger signal on the sample velocity, incident electron current, beam diameter, and desorption cross section is analyzed. It is shown that it is advantageous to analyze the moving sample with a high beam current, in contrast to the usual practice of using a low beam current to minimize desorption from a stationary sample. The method is illustrated by the analysis of a friction transfer film of PTFE, in which the fluorine is removed by electron-induced desorption. The method is relevant to surface studies in the field of lubrication and catalysis.

Pepper, S. V.↗

Biological Sterilization of Returned Mars Samples

Martian rock and soil, collected by robotic spacecraft, will be returned to terrestrial laboratories early in the next century. Current plans call for the samples to be immediately placed into biological containment and tested for signs of present or past life and biological hazards. It is recommended that "Controlled distribution of unsterilized materials from Mars should occur only if rigorous analyses determine that the materials do not constitute a biological hazard. If any portion of the sample is removed from containment prior to completion of these analyses it should first be sterilized." While sterilization of Mars samples may not be required, an acceptable method must be available before the samples are returned to Earth. The sterilization method should be capable of destroying a wide range of organisms with minimal effects on the geologic samples. A variety of biological sterilization techniques and materials are currently in use, including dry heat, high pressure steam, gases, plasmas and ionizing radiation. Gamma radiation is routinely used to inactivate viruses and destroy bacteria in medical research. Many commercial sterilizers use Co-60 , which emits gamma photons of 1.17 and 1.33 MeV. Absorbed doses of approximately 1 Mrad (10(exp 8) ergs/g) destroy most bacteria. This study investigates the effects of lethal doses of Co-60 gamma radiation on materials similar to those anticipated to be returned from Mars. The goals are to determine the gamma dose required to kill microorganisms in rock and soil samples and to determine the effects of gamma sterilization on the samples' isotopic, chemical and physical properties. Additional information is contained in the original extended abstract.

Allen, C. C.↗

Zero-valent iron nanoparticles preparation

Graphical abstract: Zero-valent iron nanoparticles were synthesized by hydrogenating [Fe[N(Si(CH{sub 3}){sub 3}){sub 2}]{sub 2}] at room temperature and a pressure of 3 atm. The synthesized nanoparticles were spherical and had diameters less than 5 nm. Highlights: ► Zero-valent iron nanoparticles were synthesized by hydrogenating [Fe[N(Si(CH{sub 3}){sub 3}){sub 2}]{sub 2}]. ► The conditions of reaction were at room temperature and a pressure of 3 atm. ► The synthesized nanoparticles were spherical and had diameters less than 5 nm. -- Abstract: Zero-valent iron nanoparticles were synthesized by hydrogenating [Fe[N(Si(CH{sub 3}){sub 3}){sub 2}]{sub 2}] at room temperature and a pressure of 3 atm. To monitor the reaction, a stainless steel pressure reactor lined with PTFE and mechanically stirred was designed. This design allowed the extraction of samples at different times, minimizing the perturbation in the system. In this way, the shape and the diameter of the nanoparticles produced during the reaction were also monitored. The results showed the production of zero-valent iron nanoparticles that were approximately 5 nm in diameter arranged in agglomerates. The agglomerates grew to 900 nm when the reaction time increased up to 12 h; however, the diameter of the individual nanoparticles remained almost the same. During the reaction, some byproducts constituted by amino species acted as surfactants; therefore, no other surfactants were necessary.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Arsenite activates NFκB through induction of C-reactive protein

C-reactive protein (CRP) is an acute phase protein in humans. Elevated levels of CRP are produced in response to inflammatory cytokines and are associated with atherosclerosis, hypertension, cardiovascular disease and insulin resistance. Exposure to inorganic arsenic, a common environmental toxicant, also produces cardiovascular disorders, namely atherosclerosis and is associated with insulin-resistance. Inorganic arsenic has been shown to contribute to cardiac toxicities through production of reactive oxygen species (ROS) that result in the activation of NFκB. In this study we show that exposure of the hepatic cell line, HepG2, to environmentally relevant levels of arsenite (0.13 to 2 μM) results in elevated CRP expression and secretion. ROS analysis of the samples showed that a minimal amount of ROS are produced by HepG2 cells in response to these concentrations of arsenic. In addition, treatment of FvB mice with 100 ppb sodium arsenite in the drinking water for 6 months starting at weaning age resulted in dramatically higher levels of CRP in both the liver and inner medullary region of the kidney. Further, mouse Inner Medullary Collecting Duct cells (mIMCD-4), a mouse kidney cell line, were stimulated with 10 ng/ml CRP which resulted in activation of NFκB. Pretreatment with 10 nM Y27632, a known Rho-kinase inhibitor, prior to CRP exposure attenuated NFκB activation. These data suggest that arsenic causes the expression and secretion of CRP and that CRP activates NFκB through activation of the Rho-kinase pathway, thereby providing a novel pathway by which arsenic can contribute to metabolic syndrome and cardiovascular disease. -- Highlights: ► Exposure to arsenic can induce the expression and secretion of CRP. ► Mice treated with NaAsO{sub 2} showed higher levels of CRP in both the liver and kidney. ► mIMCD-3 were stimulated with CRP which resulted in activation of NFκB. ► CRP activates NFκB through activation of the Rho-kinase pathway. ► Data provide novel pathway for arsenic role in metabolic and cardiovascular disease.

60 APPLIED LIFE SCIENCES↗

Focused Ion Beam Preparation of Low Melting Point Metals: Lessons Learned From Indium

Indium (In) and other low melting point metals are used as interconnects in a variety of hybridized circuits and a full understanding of the metallurgy of these interconnects is important to the reliability and performance of the devices. Here, this paper shows that room temperature focused ion beam (FIB) preparation of cross-sections, using Ga + or Xe + can result in artifacts that obscure the true In microbump structure. The use of modified milling strategies to minimize the increased local sample temperature are shown to produce cross-sections that are representative of the In bump microstructure in some sample configurations. Furthermore, cooling of the sample to cryogenic temperatures is shown to reliably eliminate artifacts in FIB prepared cross-sections of In bumps allowing the true bump microstructure to be observed.

36 MATERIALS SCIENCE↗

Unveiling the Finite Temperature Physics of Hydrogen Chains via Auxiliary Field Quantum Monte Carlo

The ability to accurately predict the finite temperature properties and phase diagrams of realistic quantum solids is central to uncovering new phases and engineering materials with novel properties ripe for device applications. Nonetheless, there remain comparatively few many-body techniques capable of elucidating the finite temperature physics of solids from first principles. Here, we take a significant step toward developing such a technique by generalizing our previous, exact fully ab initio finite temperature Auxiliary Field Quantum Monte Carlo (FT-AFQMC) method to model periodic solids and employing it to uncover the finite temperature physics of periodic hydrogen chains. Our chains’ unit cells consist of 10 hydrogen atoms modeled in a minimal basis, and we sample 5 k-points from the first Brillouin zone to arrive at a supercell consisting of 50 orbitals and 50 electrons. Based upon our calculations of these chains’ many-body energies, free energies, entropies, heat capacities, double and natural occupancies, and charge and spin correlation functions, we outline their metal–insulator and magnetic ordering as a function of both H–H bond distance and temperature. At low temperatures approaching the ground state, we observe both metal–insulator and ferromagnetic–antiferromagnetic crossovers at bond lengths between 0.5 and 0.75 Å. We then demonstrate how this low-temperature ordering evolves into a metallic phase with decreasing magnetic order at higher temperatures. In order to contextualize our results, we compare the features we observe to those previously seen in one-dimensional, half-filled Hubbard models at finite temperature and in ground state hydrogen chains. Interestingly, we identify signatures of the Pomeranchuk effect in hydrogen chains for the first time and show that spin and charge excitations that typically arise at distinct temperatures in the Hubbard model are indistinguishably coupled in these systems. Beyond qualitatively revealing the many-body phase behavior of hydrogen chains in a numerically exact manner without invoking the phaseless approximation, our efforts shed light on the further theoretical developments that will be required to construct the phase diagrams of the more complex transition metal, lanthanide, and actinide solids of longstanding interest to physicists.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AI-assisted rapid crystal structure generation towards a target local environment

In material design, traditional crystal structure prediction approaches are expensive as they require extensive structural sampling through expensive energy minimization methods. Emerging artificial intelligence (AI) generative models have shown great promise in rapidly generating realistic crystals, but they typically handle only a few tens of atoms per unit cell. To overcome this limitation, we introduce a symmetry-informed approach, the Local Environment Geometry-Oriented Crystal Generator (LEGO-xtal). Our method generates initial structures using AI models trained on an augmented dataset, and then optimizes them using structure descriptors rather than energy-based optimization. We demonstrate its effectiveness by expanding from 25 known low-energy sp2 carbon allotropes to over 1700, all within 0.5 eV/atom of the ground-state energy of graphite. This framework offers a generalizable strategy for the targeted design of materials with modular building blocks, such as metal-organic frameworks and battery materials.

Ridwan, Osman Goni [University of North Carolina a↗

Structural investigation of amorphous materials at high pressures

A modified diamond anvil cell (DAC) is used for structural studies of amorphous materials at high pressures using a monochromatic synchrotron x-ray beam. The DAC modification includes (1) the use of x-ray transparent seats for a large angular opening for x-ray scattering, and (2) the introduction of a boron gasket insert to increase the sample thickness and to minimize the gasket-hole deformation. A procedure for absorption correction and background subtraction in DAC experiments is described, together with an optimization process for obtaining accurate data of the structure factor and the corresponding pair distribution function. Data for amorphous iron at 67 GPa are presented for demonstration. It is shown that quantitative structural data can be determined for amorphous materials at very high pressures using the DAC. The apparatus should be also useful for structural studies of liquids at high pressures.

43 PARTICLE ACCELERATORS↗

Synchronous digitization for high dynamic range lock-in amplification in beam-scanning microscopy

Digital lock-in amplification (LIA) with synchronous digitization (SD) is shown to provide significant signal to noise (S/N) and linear dynamic range advantages in beam-scanning microscopy measurements using pulsed laser sources. Direct comparisons between SD-LIA and conventional LIA in homodyne second harmonic generation measurements resulted in S/N enhancements consistent with theoretical models. SD-LIA provided notably larger S/N enhancements in the limit of low light intensities, through the smooth transition between photon counting and signal averaging developed in previous work. Rapid beam scanning instrumentation with up to video rate acquisition speeds minimized photo-induced sample damage. The corresponding increased allowance for higher laser power without sample damage is advantageous for increasing the observed signal content.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a new airborne humidigraph system.

Modeling and measurements of aerosol properties is complicated by the hygroscopic behavior of the aerosols adding significant uncertainty to our best estimates of the direct effect aerosols exert on the radiative balance of the atmosphere. Airborne measurements of aerosol hygroscopicity are particularly challenging but critically needed. This motivated the development of a newly designed system which can measure the dependence of the aerosol light scattering coefficient (σsp) on relative humidity (RH), known as f(RH), in real-time at a rapid rate (<10 s) on an aerial platform. The new system has several advantages over existing systems. It consists of three integrating nephelometers and humidity conditioners for simultaneous measurement of the σsp at three different RHs. The humidity is directly controlled in exchanger cells without significant temperature disturbances and without particle dilution, heating or loss of volatile compounds. The single-wavelength nephelometers are illuminated by LED-based light sources thereby minimizing heating of the sample stream. The flexible design of the RH conditioners, consisting of a number of specially designed exchanger cells (driers or humidifiers), enables us to measure f(RH) under hydration or dehydration conditions (always starting with the aerosol in a known state) with a simple system re-configuration. These exchanger cells have been characterized for losses of particles using latex spheres and laboratory generated ammonium sulfate aerosols. Residence times of 6 - 9 s in the exchangers and subsequent lines is sufficient for most aerosols to attain equilibrium with the new water vapor content. The performance of this system has been assessed aboard DOE’s G-1 research aircraft during test flights over California, Oregon, and Washington.

Pekour, Mikhail S↗

Learning of networked spreading models from noisy and incomplete data

Recent years have seen a lot of progress in algorithms for learning parameters of spreading dynamics from both full and partial data. Some of the remaining challenges include model selection under the scenarios of unknown network structure, noisy data, missing observations in time, as well as an efficient incorporation of prior information to minimize the number of samples required for an accurate learning. Here, in this work, we introduce a universal learning method based on a scalable dynamic message-passing technique that addresses these challenges often encountered in real data. The algorithm leverages available prior knowledge on the model and on the data, and reconstructs both network structure and parameters of a spreading model. We show that a linear computational complexity of the method with the key model parameters makes the algorithm scalable to large network instances.

97 MATHEMATICS AND COMPUTING↗

Optimized replica gas estimation of absolute integrals and partition functions.

In contrast with most Monte Carlo integration algorithms, which are used to estimate ratios, the replica gas identities recently introduced by Adib enable the estimation of absolute integrals and partition functions using multiple copies of a system and normalized transition functions. Here, an optimized form is presented. After generalizing a replica gas identity with an arbitrary weighting function, we obtain a functional form that has the minimal asymptotic variance for samples from two replicas and is provably good for a larger number. This equation is demonstrated to improve the convergence of partition function estimates in a two-dimensional Ising model.

36 MATERIALS SCIENCE↗

Feature Analysis, Tracking, and Data Reduction: An Application to Multiphase Reactor Simulation MFiX-Exa for In-Situ Use Case

As we enter the exascale computing regime, powerful supercomputers continue to produce much higher amounts of data than what can be stored for offline data processing. To utilize such high compute capabilities on these machines, much of the data processing needs to happen in situ, when the full high-resolution data is available at the supercomputer memory. In this article, we discuss our MFiX-Exa simulation, which models multiphase flow by tracking a very large number of particles through the simulation domain. In one of the use cases, the carbon particles interact with air to produce carbon dioxide bubbles from the reactor. These bubbles are of primary interest to the domain experts for these simulations. For this particle-based simulation, we propose a streaming technique that can be deployed in situ to efficiently identify the bubbles, track them over time, and use them to down-sample the data with minimal loss in these features.

97 MATHEMATICS AND COMPUTING↗